NMSU Fire Department 2018 Annual Fire Safety Report Clery Act Requirement

Similar documents
NMSU Fire Department 2017 Annual Fire Safety Report Clery Act Requirement

NMSU Fire Department Annual Fire Safety Report Clery Act Requirement

Fires in On-Campus Housing Facilities 2009

2012 Vanderbilt University Fire Safety Report

Fire Safety HATE CRIMES STUDENT FIRE SAFETY REGULATIONS VANDERBILT PROGRAMS OUTSIDE NASHVILLE RESIDENCE BUILDING FIRE SAFETY SYSTEMS

Fire Safety. Residence Hall Fire Safety Systems. Student Fire Safety Regulations

Fire Safety Systems of On-Campus Student Housing Facilities Fire Detection

Arkansas State University Higher Education Opportunity Act (HEOA) 2013 Campus Fire Safety Annual Compliance Report

CAMPUS SECURITY AND FIRE SAFETY

FIRE INCIDENT REPORTING

OLD DOMINION UNIVERSITY

SAGU AMERICAN INDIAN COLLEGE 2018 ANNUAL FIRE SAFETY REPORT INCLUDING STATISTICS FOR THE 2017 CALENDAR YEAR PREPARED BY:

Annual Fire Safety Report

2011 Nature of the Fire (cause)

2012 Nature of the Fire (cause)

2018 Annual Fire Safety Report

Annual Fire Safety Report

Fire Safety Report Fire Protection Management Program and Annual Fire Safety Report on Student Housing

THE 2016 ANNUAL FIRE SAFETY REPORT. Including Statistics for the 2015 Calendar Year. Prepared by: Ron Crane Director of Safety & Security

2018 Annual Fire Safety Report

LIFE SAFETY CODE ESSENTIALS PRESENTED BY: LARRY VIGIL, RISK CONSULTANT

Arkansas State University Higher Education Opportunity Act (HEOA) 2014 Campus Fire Safety Annual Compliance Report

OVERVIEW OF THE HEOA FIRE SAFETY REQUIREMENTS NOTICE, AVAILABILITY, AND LOCATION OF THE ANNUAL FIRE SAFETY REPORT

Roger Williams University 2016 Fire Safety Report. 1 1 Unknown source of fire in dumpster

ANNUAL FIRE SAFETY REPORT October 1, 2018 ALBERT EINSTEIN COLLEGE OF MEDICINE JACK AND PEARL RESNICK CAMPUS BRONX, NY

Annual Fire Safety Report Icahn School of Medicine at Mount Sinai Aron Hall September, 2016

THE ANNUAL FIRE SAFETY REPORT

YESHIVA UNIVERSITY. Annual Fire Safety Report. October 1, Israel Henry Beren Campus. Murray Hill section of Manhattan.

Mount Mercy University. Department of Public Safety. Campus Fire Safety Annual Compliance Report. Overview:

Northwest Mississippi Community College

ANNUAL FIRE SAFETY REPORT October 1, 2014 ALBERT EINSTEIN COLLEGE OF MEDICINE JACK AND PEARL RESNICK CAMPUS BRONX, NY

Safety Manual Section 7 Fire/Life Safety

2017 Annual Fire Safety Report

Higher Education Opportunity Act 2015 Campus Fire Safety Annual Compliance Report

KSU s ANNUAL FIRE SAFETY REPORT FOR CAMPUS HOUSING Calendar Year 2013

2014 Annual Fire Safety Report

ANNUAL FIRE SAFETY REPORT

THE ANNUAL FIRE SAFETY REPORT

Fire Safety System Residential housing and all other buildings on campus are equipped with several fire detection and prevention systems.

Boston College Campus Safety and Security Policies Fire Safety Program

CAMPUS SAFETY DEPARTMENT ANNUAL FIRE SAFETY REPORT AND FIRE STATISTICS

Grossmont Cuyamaca Community College District Fire Report 2014

UNIVERSITY OF RICHMOND HOUSING FIRE SAFETY POLICY

2014 Fire Safety Report

Defiance College Annual Fire Safety Report for 2016

SALISBURY UNIVERSITY 2015 ANNUAL FIRE SAFETY REPORT

Fire Safety System Residential housing and all other buildings on campus are equipped with several fire detection and prevention systems.

Annual Fire Safety Report. CSU Bakersfield

2016 Fire Safety Report

Boston College Campus Safety and Security Policies Fire Safety Program

REED COLLEGE DEPARTMENT OF COMMUNITY SAFETY DEPARTMENTAL DIRECTIVE CSO FIRE & FIRE ALARM SYSTEM RESPONSE GUIDELINES

Purpose: To establish procedures for identifying fire hazards and preventing fires. Scope: All Central New Mexico Community College (CNM) Community.

2017 Annual Fire Safety Report

Campus Fire Safety Right-to-Know

Academics Efficient use of space will be used to enhance investments in new pedagogies such as active learning classrooms.

Fire Prevention Plan. California State University, Chico

2015 Campus Fire Safety Annual Compliance Report

October 1, Full *2 Sprinkler System

Fire Safety Act Report (FSAR) Issued September 2017 California State University, Long Beach

Grossmont Cuyamaca Community College District Fire Report 2012

SALISBURY UNIVERSITY 2012 ANNUAL FIRE SAFETY REPORT

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Westminster College Fire Safety Report

Annual Fire Safety Report. CSU Bakersfield

University Housing Fires

Washburn University Topeka, Kansas Higher Education Act Annual Fire Report

2018 Concordia College Moorhead MN Campus Public Safety Fire Safety Report

2018 Annual Fire Safety Report for Student Housing California State University, Northridge (CSUN)

PROSPECT COLLEGE HEALTH AND SAFETY PLANS FIRE PREVENTION PLAN

YESHIVA UNIVERSITY. Annual Fire Safety Report. October 1, Wilf Campus. Washington Heights section of Manhattan. 1 P age

2017 Annual Clery Fire Safety Report for Student Housing California State University, Northridge

New DATE OF BLDG. PERMIT OR PLAN APPROVAL: SURVEYOR (SIGNATURE) TITLE OFFICE DATE REVIEW AUTHORITY OFFICIAL (SIGNATURE) TITLE OFFICE DATE

Susquehanna University Annual Fire Safety Report 2015

2010 Fire Log Fire Log. Annual Fire Safety Report

Housing and Residence Life Fire Reporting

Roger Williams University Fire Safety Report. 1 1 Unintentional/Stove Fire. 0 0 n/a n/a n/a n/a. 0 0 n/a n/a n/a n/a. 0 0 n/a n/a n/a n/a

Fire Safety Report Fire Protection Management Program and Annual Fire Safety Report on Student Housing

UNIVERSITY OF RICHMOND HOUSING FIRE SAFETY POLICY

School Fire Safety Checklist

2017 Concordia College Moorhead MN Campus Public Safety Fire Safety Report

As a service however, Physical Plant Fire Services conduct periodic scheduled inspections and training with Auxiliary and Greek organizations.

Agency for Health Care Administration

Department of Campus Safety & Security

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

2015 UC San Diego Annual Fire Safety Report Table of Contents

ANNUAL FIRE SAFETY REPORT OF 2017 SAINT JOSEPH SEMINARY COLLEGE

RESIDENCE HALL FIRE REPORT

Fire Safety, Risks, & Response at Jackson Health System JHS Annual Mandatory Education

Annual Fire Safety Report

ANNUAL FIRE SAFETY REPORT FOR RESIDENCE HALLS

Academic and Administrative Buildings

Health and Safety Plans Health and Safety Policy Statement Fire Prevention Plan Objective

HOBART AND WILLIAM SMITH COLLEGES

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

Fire/Life Safety Policy

Candles (including those used for religious purposes), incense, and other open flame devises are not allowed in residential buildings.

Fire Department Quarterly Report

2017 FIRE SAFETY REPORT

CAMPUS COMMUNITY FIRE AND LIFE SAFETY POLICY

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

Transcription:

New Mexico State University Fire Safety Reporting [18] HEOA Reporting Date: January 1, 2017 to December 31, 2017 NOTE: All fire drills reported below are supervised, meet International Fire Code Chapter 4 Emergency Planning and Preparedness, and have mandatory evacuation for all individuals. During the fire drills there is an inspection of: audio sound, synchronization of light strobes, exit doors, and other factors of the system in place. I. On-campus student housing facilities, description of the facilities and description of fire safety system. Garcia Hall (1715 International Mall) Residence Halls Garcia Hall is a three-story fire resistive building with four patios. Dorm rooms encircle the patios. Fire Protection: Dorm rooms contain individual smoke detectors. Pull stations and smoke alarms in the common areas are monitored by a fire alarm system. The fire alarm system is inspected/tested annually and maintained to NFPA 72 and it reports directly to NMSU PD dispatch center. Rooms and main areas are protected by an automatic wet pipe sprinkler system. The fire sprinkler system is inspected quarterly and maintained to NFPA 25. Fire Drill: 1 on 02/06/2017 Fire Drill: 1 on 09/12/2017 One fire reported. Information is in section II Fire Statistics. Piñon Hall (1780 East University Avenue) Piñon Hall is a three-story wood frame structure. The building is two separate sections connected by a common area. Fire Protection: Dorm rooms contain individual smoke detectors. Pull stations and smoke alarms in the common areas are monitored by a fire alarm system. The fire alarm system is inspected/tested annually and maintained to NFPA 72 and it reports directly to NMSU PD dispatch center. Rooms and main areas are protected by an automatic wet pipe sprinkler system. The fire sprinkler system is inspected quarterly and maintained to NFPA 25. Fire Drill: 1 on 02/06/2017 1

Fire Drill: 1 on 09/12/2017 NMSU Fire Department Rhodes-Garrett-Hamiel (RGH) (2715-2735 Jordan Road) RGH is a three-story fire resistive building with traditional dorm rooms off the main hallway. Fire Protection: Dorm rooms contain individual smoke detectors. Pull stations in the common areas are monitored by a fire alarm system. The fire alarm system is inspected/tested annually and maintained to NFPA 72 and it reports directly to NMSU PD dispatch center. Hallways and corridors are protected by with an automatic wet pipe sprinkler system. The fire sprinkler system is inspected quarterly and maintained to NFPA 25. Fire Drill: 1 on 02/06/2017 Fire Drill: 1 on 09/11/2017 One fire reported. Information is in section Arson Fires. Cervantes Village Campus Apartments Cervantes Village are multiple single story wood frame buildings, they contain one, two, and four bedroom apartments. Fire Protection: The rooms contain individual smoke detectors and CO alarm detectors. No fire reported. Information is in section II Fire Statistics. Chamisa Village I & II (1735 Stewart Street) Chamisa Village is a complex made-up of three-story wood frame buildings. Apartments come in two and four bedroom layouts. Fire Protection: Apartments contain individual smoke detectors. Pull stations and smoke alarms in the common areas are monitored by a fire alarm system. The fire alarm system is inspected/tested annually and maintained to NFPA 72 and it reports directly to NMSU PD dispatch center. Rooms and main areas are 2

protected by an automatic wet pipe sprinkler system. The fire sprinkler system is inspected quarterly and maintained to NFPA 25. Chamisa Village I Fire Drill: 1 on 02/07/2017 Fire Drill: 1 on 09/11/2017 Chamisa Village II Fire Drill: 1 on 02/07/2017 Fire Drill: 1 on 09/11/2017 No fire reported. Information is in section II Fire Statistics. Vista Del Monte Vista Del Monte is a complex made up of two story wood frame buildings. Apartments are in two-bedroom configuration. Fire Protection: Apartments contain individual smoke detectors and CO detectors. Family Housing Tom Fort and Sutherland Villages Tom Fort and Sutherland are single-family, single story fire resistive homes. Fire Protection: The homes contain individual smoke detectors and CO detectors. One fire reported. Information is in section II Fire Statistics. 3

Chi Omega (1700 East University Avenue) Greek Housing Chi Omega is a residential sorority, two story wood frame home. Fire Protection: Bedrooms contain individual smoke detectors. Smoke alarms in the common areas are monitored by a fire alarm system. The fire alarm system is inspected/tested annually and maintained to NFPA 72 and it reports directly to NMSU PD dispatch center. Rooms and common areas are covered by an automatic wet pipe sprinkler system. The fire sprinkler system is inspected quarterly and maintained to NFPA 25. Fire Drill: 1 on 02/06/2017 Fire Drill: 1 on 09/12/2017 Delta Zeta (1600 East University Avenue) Delta Zeta is a residential sorority, single story wood frame home. Dorm rooms contain individual smoke detectors. Smoke alarms in the common areas are monitored by a fire alarm system. The fire alarm system is inspected/tested annually and maintained to NFPA 72 and it reports directly to NMSU PD dispatch center. Rooms and common areas are covered by an automatic wet pipe sprinkler system. The fire sprinkler system is inspected quarterly and maintained to NFPA 25. Fire Drill: 1 on 02/07/2017 Fire Drill: 1 on 09/12/2017 Zeta Tau Alpha (1699 East University Avenue) Zeta Tau Alpha is a residential sorority, two story wood frame home. Fire Protection: Smoke detectors throughout the building and pull stations in the hallways are monitored by a fire alarm system. The fire alarm system is inspected/tested annually and maintained to NFPA 72 and it reports directly to NMSU PD dispatch center. Rooms and common areas are covered by an automatic wet pipe sprinkler system. The fire sprinkler system is inspected quarterly and maintained to NFPA 25. 4

Fire Drill: 1 on 02/07/2017 Fire Drill: 1 on 09/12/2017 NMSU Fire Department Fires in Non-Academic Buildings Non-Academic Buildings Gardiner Hall (1255 North Horseshoe) Academic Buildings Gardiner Hall is a multi-story Fire Resistive Non-Combustible building that houses offices, lecture rooms, laboratories, and classroom areas. Fire Protection: Gardiner Hall is equipped with a full addressable fire alarm system and is covered by an automatic wet pipe sprinkler system. The fire alarm system is inspected/tested annually and maintained to NFPA 72 and it reports directly to NMSU PD dispatch center. The fire sprinkler system is inspected quarterly and maintained to NFPA 25. Fire Drill on 09/11/2017 Gerald Thomas Hall (940 E. College Avenue) Gerald Thomas Hall is a multi-story Fire Resistive Non-Combustible building that houses offices, lecture rooms, and classrooms. Fire Protection: Gerald Thomas Hall is equipped with a full addressable fire alarm system. The fire alarm system is inspected/tested annually and maintained to NFPA 72 and it reports directly to NMSU PD dispatch center. Fire Drill on 09/11/2017 5

Goddard Hall and Annex (1100 South Horseshoe) Goddard Hall and Annex is a multi-story Fire Resistive Non-Combustible building that houses offices, lecture rooms, laboratories, and classroom areas. Fire Protection: Goddard Hall and Annex is equipped with a full addressable fire alarm system and is covered by an automatic wet pipe sprinkler system. The fire alarm system is inspected/tested annually and maintained to NFPA 72 and it reports directly to NMSU PD dispatch center. The fire sprinkler system is inspected quarterly and maintained to NFPA 25. Fire Drill on 09/11/2017 Milton Hall (2915 McFie Circle) Milton Hall is a multi-story Fire Resistive Non-Combustible building that houses offices, conference rooms, classrooms, lecture rooms, laboratories, and work station areas. Fire Protection: Milton Hall is equipped with a full addressable fire alarm system and is covered by an automatic wet pipe sprinkler system. The fire alarm system is inspected/tested annually and maintained to NFPA 72 and it reports directly to NMSU PD dispatch center. The fire sprinkler system is inspected quarterly and maintained to NFPA 25. Fire Drill on 09/12/2017 Thomas and Brown Hall (1125 Frenger Mall) Thomas and Brown Hall is a multi-story Fire Resistive Non-Combustible building that houses offices, lecture rooms, laboratories and classroom areas. Fire Protection: Thomas and Brown Hall is equipped with a full addressable fire alarm system and is covered by an automatic wet pipe sprinkler system. The fire alarm system is inspected/tested annually and maintained to NFPA 72 and it reports directly to NMSU PD dispatch center. The fire sprinkler system is inspected quarterly and maintained to NFPA 25.Fire Drill on 09/12/2017 Fires in Academic Buildings One fire reported at Chemistry Hall, 1175 North Horseshoe. Information is in section II Fire Statistics. 6

Fatality or Casualty Fires None reported. Arson Fires None reported or identified. II. Fire Statistics 2017 Digital Fire Log FIRES INSIDE STRUCTURES DATE ADDRESS INCIDENT 09/25/2017 975 Gregg Street (Sutherland Village) 113 - Cooking fire, confined to container 10/20/2017 2725 Jordan Road (Rhodes-Garrett-Hamiel (RGH) 113 - Cooking fire, confined to container 11/07/2017 1175 North Horseshoe (Chemistry Building) 251 - Excessive heat, scorch burns with no ignition 11/08/2017 1715 International Mall (Garcia Hall) 113 - Cooking fire, confined to Container FIRES OUTSIDE STRUCTURES DATE ADDRESS INCIDENT 1/29/2017 4525 Observatory Road 150 - Outside rubbish fire, other 3/2/2017 1175 North Horseshoe 151 - Outside rubbish, trash or waste fire 4/25/2017 2902 McFie Circle 143 - Grass fire 5/6/2017 East Union Avenue 151 - Outside rubbish, trash or waste fire 5/15/2017 College Avenue 151 - Outside rubbish, trash or waste fire 5/22/2017 College Avenue 140 - Natural vegetation fire, other 12/2/2017 3005 Arrowhead Drive 154 - Dumpster or other outside trash receptacle fire 7

III. New Mexico State University Fire Prevention Guidelines and Practices Found online at: https://fire.nmsu.edu/fire-prevention-guidelines/ IV. 2017 Annual Security Report, New Mexico State University Police Department Found online at: https://www.nmsupolice.com/annual-reports/ V. 2017 Annual Reports, New Mexico State University Fire Department Found online at: https://fire.nmsu.edu/annual-reports/ New Mexico State University Fire Department offers free Portable Fire Extinguisher Training. To sign up for a class, go to Training Central: https://trainingcentral.nmsu.edu/. 8