May, 2004 Commercial & Industrial Applied Product Line Heating Ventilating Cooling Make-Up Air

Similar documents
FEATURES AND BENEFITS

Gas-Fired Indoor and Outdoor Duct Furnaces

Gas-Fired Indoor and Outdoor Duct Furnaces

Gas-Fired Unit Heaters Commercial & Industrial

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS

Cabinet Unit Heaters Steam / Hot Water

Indirect Gas-Fired Make-Up Air

LARGE CAPACITY HEATERS

Modular Heating & Ventilating Unit Model IGX-HV

GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS

Modular Supply Make-Up Air Unit

Convectors Steam / Hot Water November, 2009

Direct Gas-Fired Make-Up Air Models DG and DGX

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

INDIRECT GAS-FIRED AIR HEATER

Direct Fired Heater Model AD Specification

SUBMITTAL SCHEDULE & DATA

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

Direct Gas-Fired Make-Up Air Models DGK, DG and DGX

Gas-Fired Unit Heaters Commercial & Industrial

Make-Up Air March 2012

Gas-Fired Indoor Duct Furnace Gravity and Power Vented

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

HVAC EQUIPMENT for Residential, Industrial & Commercial Applications GACP-22

MODEL ADF/ADFH 300 and 500 INDOOR/OUTDOOR DIRECT-FIRED GAS HEATING/MAKEUP AIR SYSTEM FOR INDUSTRIAL & COMMERCIAL APPLICATIONS

Direct Gas-Fired Make-Up Air

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

Make-Up Air Systems. Performance. Model DGK, DG, DGX

GLOBAL FINISHING SOLUTIONS

The ultimate fresh air solution.

COMMERCIAL & INDUSTRIAL UNITARY HEATING PRODUCTS GAS STEAM/HOT WATER OIL ELECTRIC

GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

SKYPAK II, 3 Ton Series, gives you a

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

SKYPAK II, 3 Ton Series, gives you a

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Submittal Data Performance Data Electrical Data

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

RG7D 1-Stage Heat Series

ADF/ADFH 300 and 500

AUGUST, High-Efficiency Condensing Gas-Fired Separated Combustion Unit Heaters

HVAC EQUIPMENT for Residential, Industrial & Commercial Applications GACP-20

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

48TF GAS HEATING/ ELECTRIC COOLING UNITS

INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

KIC Air Curtains. Technical Guide

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

RGE 13 A T - 1 A

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

INFRARED RADIANT HEATERS

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Energy Recovery with Cooling and Heating Model ERCH

SUH-8 UNIT HEATERS. High Efficiency Heating Equipment

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

GQVC-12 HVAC EQUIPMENT. GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces.

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

AHRI Certification Program Scopes - COOLING

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

Section (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating

48TM GAS HEATING/ELECTRIC COOLING UNITS

SKYPAK II Heating & Cooling Self Contained Packages

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

WARNING. APPLICATION DATA greenhouse blower unit heaters models BD, BDP and BSH Contents

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Advance Release September 2009

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

The H Series. Pure and Simple Solutions. HTLV Space Heating

Counterflo CF BASIC COUNTERFLO HEATER RCF CURB MOUNTED ROOFTOP HEATER CFDF COUNTERFLO DUCT FURNACE INDIRECT-FIRED INDUSTRIAL HEATERS

INSTALLATION, OPERATION & MAINTENANCE MANUAL INDIRECT GAS-FIRED DUCT FURNACE

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

Wall Mounted Air Conditioners with Gas Heat Models AVGA

STEP INSIDE FOR A BREATH OF FRESH AIR. Designed to provide significant outdoor ventilation air to any space.

DES CHAMPS PRODUCTS 85% 4,400 CFM

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Technical Development Program

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Ruud Achiever Series Multi position Gas Furnaces

Transcription:

75-137.5 May, 2004 Commercial & Industrial Applied Product Line Heating Ventilating Cooling Make-Up Air

MODINE COMMERCIAL & INDUSTRIAL APPLIED PRODUCT LINE Modine has always been the industry standard in the commercial and industrial comfort-heating market. With the Modine product line, you can solve your application needs with duct furnaces and direct-fired or indirect-fired make-up air systems, with heating capacities up to 7,862,000 Btu/hr. Available in indoor and outdoor configurations, air-handling capacities are as high as 60,000 CFM. Modine sales representatives are experienced specialists in the engineering, selection and application of Modine commercial and industrial heating and ventilating equipment. Located near you, these representatives can help you satisfy your comfort needs and indoor air-quality requirements. Contact your Modine product source for assistance in providing top-quality, high-efficiency Indoor Air Solutions. 2

CONTENTS Indoor Gas-Fired Duct Furnaces Heating and/or Make-up Air Units 4 PAGE Indoor Gas-Fired System Units Heating, Cooling, Ventilating, and Make-Up Air Units 5 Indoor Gas-Fired Separated Combustion Duct Furnace Heating and/or Make-up Air Units 6 Indoor Gas-Fired Separated Combustion System Units Heating, Cooling, Ventilating, and Make-Up Air Units 7 WeatherHawk TM Weatherproof Gas-Fired Duct Furnace Heating and/or Make-Up Air Units 8 WeatherHawk TM Weatherproof Gas-Fired System Units Heating, Cooling, Ventilating, and Make-Up Air Units 9 Direct-Fired Make-Up Air Units 10 3

INDOOR GAS-FIRED GRAVITY VENTED DUCT FURNACE HEATING AND/OR MAKE-UP AIR UNITS Low Initial Cost Applications Cover Heating and/or Make-Up Air 75,000 to 400,000 Btu/Hr Input Capacity Low Maintenance Easy to Service The Modine indoor gravity vented duct furnace was designed for use with a building s heating, heating/cooling and make-up air systems. Modine gravity vented duct furnaces are specifically designed for lost cost installations. Available in 11 model sizes, the unit covers a wide variety of applications. They have input ranges from 75,000 to 400,000 Btu/Hr and can operate on either natural or propane gas. The airflow direction can be specified when ordering the unit. The duct furnace is certified for location either upstream or downstream from cooling coils and has a drain pan that allows connection to a condensate drain line. MODEL DFG C.S.A. certification bearing C.S.A. logos ETL certification All units a minimum of 80% thermally efficient 20 gauge aluminized steel cabinet Certified to 3.0" W.C. external static pressure 409 stainless steel heat exchanger and burner 409 stainless steel drip pan Two-stage, mechanical modulation, and electronic modulation controls for either natural or propane gas Building management compatible gas controls for modulation control using 0-10 Vdc or 4-20 ma input High and/or low gas pressure switches Performance Data ➀ ➁ Btu/Hr Low Temperature High Temperature Model Temperature Rise Temperature Rise No. Input Output Range ( F) Range ( F) DFG 75 75,000 60,000 20-60 926-2,778 20-100 556-2,778 DFG100 100,000 80,000 20-60 1,235-3,704 20-100 741-3,704 DFG125 125,000 100,000 20-60 1,543-4,630 20-100 926-4,630 DFG150 150,000 120,000 20-60 1,852-5,556 20-100 1,111-5,556 DFG175 175,000 140,000 20-60 2,160-6,481 20-100 1,296-6,481 DFG200 200,000 160,000 20-60 2,469-7,407 20-100 1,481-7,407 DFG225 225,000 180,000 20-60 2,778-8,333 20-100 1,667-8,333 DFG250 250,000 200,000 20-60 3,086-9,259 20-100 1,852-9,259 DFG300 300,000 240,000 20-60 3,704-11,111 20-100 2,222-11,111 DFG350 350,000 280,000 20-60 4,321-12,963 23-100 2,593-11,111 DFG400 400,000 320,000 20-60 4,938-14,815 27-100 2,963-11,111 ➀ Ratings are shown for elevations up to 2,000 feet. ➁ Units approved for use in California by CEC. DO NOT LOCATE ANY GAS-FIRED UNIT IN AREAS WITH CHLORINATED, HALOGENATED OR ACIDIC VAPORS IN ATMOSPHERE. Request Catalog 5-173 For Complete Technical Information and Specifications. 4

INDOOR GAS-FIRED GRAVITY VENTED SYSTEM UNITS HEATING, COOLING, VENTILATING, AND MAKE-UP AIR UNITS Applications Cover Heating-Only, Heating/Ventilating, Cooling, and/or Make-Up Air 75,000 to 1,200,000 Btu/Hr Input Capacity Large Selection of Blower Fan/Drive and Motor Combination Available Easy to Service The Modine indoor gravity vented duct furnace with blower and/or cooling sections was designed for use with a building s heating, heating/ventilating/cooling and make-up air systems. Modine gravity vented duct furnaces are specifically designed for low cost installations. Available in 17 model sizes, the unit covers a wide variety of applications. They have input ranges from 75,000 to 1,200,000 Btu/Hr and can operate on either natural or propane gas. The airflow ranges from 556 to 14,500 CFM and the airflow direction can be specified when ordering the unit. The unit can be provided with a cooling coil section with either a factory installed DX or chilled water cooling coil or the coil can be provided by others. MODEL DBG ETL certification of the entire system unit 18 gauge insulated aluminized steel blower cabinet with a baked-on polyester powder paint finish on exterior casing parts Blower performance up to 3.0" W.C. external static pressure DX or chilled water section with factory installed cooling coil Double wall construction for blower and/or cooling cabinet Dead-front disconnect switches Two position, modulating, building pressure sensing, three position, building management (0-10 Vdc or 4-20 ma input) damper actuators Blower and motor vibration isolation Performance Data Total Static Model Btu/Hr Btu/Hr Temperature CFM Pressure Range No. Input ➀ Output ➀ Rise Range ( F) Range (Inches w.c.) DBG/DCG75 75,000 60,000 20-100 556-2,778 0-3.0 DBG/DCG100 100,000 80,000 20-100 741-3,704 0-3.0 DBG/DCG125 125,000 100,000 20-100 926-4,630 0-3.0 DBG/DCG150 150,000 120,000 20-100 1,111-5,556 0-3.0 DBG/DCG175 175,000 140,000 23-100 1,296-5,556 0-3.0 DBG/DCG200 200,000 160,000 23-100 1,481-6,500 0-3.0 DBG/DCG225 225,000 180,000 26-100 1,667-6,500 0-3.0 DBG/DCG250 250,000 200,000 20-100 1,852-9,259 0-3.0 DBG/DCG300 300,000 240,000 20-100 2,222-11,111 0-3.0 DBG/DCG350 350,000 280,000 22-100 2,593-12,000 0-3.0 DBG/DCG400 400,000 320,000 25-100 2,963-12,000 0-3.0 DBG/DCG500 500,000 400,000 40-120 3,086-9,259 0-3.0 DBG/DCG600 600,000 480,000 40-120 3,704-11,111 0-3.0 DBG/DCG700 700,000 560,000 40-120 4,321-12,963 0-3.0 DBG/DCG800 800,000 640,000 41-120 4,938-14,500 0-3.0 DBG/DCG840 1,050,000 840,000 60-120 6,481-12,963 0-3.0 DBG/DCG900 1,200,000 960,000 63-120 7,407-14,500 0-3.0 ➀ Ratings are shown for elevations up to 2000 feet. Cooling Coil Performance Data Model No. Maximum CFM Cooling Coil Max. Cooling Tons ➁ DX Coil➂ Chilled Water Coil➂ 75 1,891 9.38 10.56 100/125 2,206 11.43 12.62 150/175 2,521 13.42 14.77 200/225 3,352 18.12 19.28 250/300 3,724 20.24 21.33 350/400 5,214 27.26 29.25 ➁ ➂ 1 Ton = 12,000 Btu/Hr Based on 95 F entering dry bulb, 75 F entering wet bulb Request Catalog 5-173 For Complete Technical Information and Specifications. 5

INDOOR GAS-FIRED SEPARATED COMBUSTION DUCT FURNACE HEATING AND/OR MAKE-UP AIR UNITS Low Initial Cost Applications Cover Heating and/or Make-Up Air 75,000 to 400,000 Btu/Hr Input Capacity Low Maintenance Easy to Service The Modine indoor separated combustion duct furnace was designed for use with a building s heating, heating/cooling and make-up air systems. Modine separated combustion duct furnaces are specifically designed for buildings with hostile atmospheric conditions, such as high humidity or negative pressures. Available in 11 power exhausted model sizes, the unit covers a wide variety of applications. They have input ranges from 75,000 to 400,000 Btu/Hr and can operate on either natural or propane gas. The airflow direction can be specified when ordering the unit. The duct furnace is certified for location either upstream or downstream from cooling coils and has a drain pan that allows connection to a condensate drain line. MODEL DFS C.S.A. certification bearing C.S.A. logos ETL certification All units a minimum of 80% thermally efficient 20 gauge aluminized steel cabinet Certified to 3.0" W.C. external static pressure Separate electrical, venting, and gas control access with fully gasketed doors 409 stainless steel heat exchanger and burner 409 stainless steel drip pan Two-stage, mechanical modulation, and electronic modulation controls for either natural or propane gas Building management compatible gas controls for modulation control using 0-10 Vdc or 4-20 ma input High and/or low gas pressure switches Performance Data ➀ ➁ Btu/Hr Low Temperature High Temperature Model Temperature Rise Temperature Rise No. Input Output Range ( F) Range ( F) DFS 75 75,000 60,000 20-60 926-2,778 20-100 556-2,778 DFS100 100,000 80,000 20-60 1,235-3,704 20-100 741-3,704 DFS125 125,000 100,000 20-60 1,543-4,630 20-100 926-4,630 DFS150 150,000 120,000 20-60 1,852-5,556 20-100 1,111-5,556 DFS175 175,000 140,000 20-60 2,160-6,481 20-100 1,296-6,481 DFS200 200,000 160,000 20-60 2,469-7,407 20-100 1,481-7,407 DFS225 225,000 180,000 20-60 2,778-8,333 20-100 1,667-8,333 DFS250 250,000 200,000 20-60 3,086-9,259 20-100 1,852-9,259 DFS300 300,000 240,000 20-60 3,704-11,111 20-100 2,222-11,111 DFS350 350,000 280,000 20-60 4,321-12,963 23-100 2,593-11,111 DFS400 400,000 320,000 20-60 4,938-14,815 27-100 2,963-11,111 ➀ Ratings are shown for elevations up to 2,000 feet. ➁ Units approved for use in California by CEC. DO NOT LOCATE ANY GAS-FIRED UNIT IN AREAS WITH CHLORINATED, HALOGENATED OR ACIDIC VAPORS IN ATMOSPHERE. Request Catalog 5-173 For Complete Technical Information and Specifications. 6

INDOOR GAS-FIRED SEPARATED COMBUSTION SYSTEM UNITS HEATING, COOLING, VENTILATING, AND MAKE-UP AIR UNITS Applications Cover Heating-Only, Heating/Ventilating, Cooling, and/or Make-Up Air 75,000 to 1,200,000 Btu/Hr Input Capacity Large Selection of Blower Fan/Drive and Motor Combination Available Easy to Service The Modine indoor separated combustion duct furnace with blower and/or cooling sections was designed for use with a building s heating, heating/ventilating/cooling and make-up air systems. Modine separated combustion duct furnaces are specifically designed for buildings with hostile atmospheric conditions, such as high humidity or negative pressures. Available in 17 power exhausted model sizes, the unit covers a wide variety of applications. They have input ranges from 75,000 to 1,200,000 Btu/Hr and can operate on either natural or propane gas. The airflow ranges from 556 to 14,500 CFM and the airflow direction can be specified when ordering the unit. The unit can be provided with a cooling coil section with either a factory installed DX or chilled water cooling coil or the coil can be provided by others. MODEL DBS MODEL DCS ETL certification of the entire system unit 18 gauge insulated aluminized steel blower cabinet with a baked-on polyester powder paint finish on exterior casing parts Blower performance up to 3.0" W.C. external static pressure Separate electrical, venting, and gas control access with fully gasketed doors DX or chilled water section with factory installed cooling coil Double wall construction for blower and/or cooling cabinet Dead-front disconnect switches Two position, modulating, building pressure sensing, three position, building management (0-10 Vdc or 4-20 ma input) damper actuators Blower and motor vibration isolation Performance Data Total Static Model Btu/Hr Btu/Hr Temperature CFM Pressure Range No. Input ➀ Output ➀ Rise Range ( F) Range (Inches w.c.) DBS/DCS75 75,000 60,000 20-100 556-2,778 0-3.0 DBS/DCS100 100,000 80,000 20-100 741-3,704 0-3.0 DBS/DCS125 125,000 100,000 20-100 926-4,630 0-3.0 DBS/DCS150 150,000 120,000 20-100 1,111-5,556 0-3.0 DBS/DCS175 175,000 140,000 23-100 1,296-5,556 0-3.0 DBS/DCS200 200,000 160,000 23-100 1,481-6,500 0-3.0 DBS/DCS225 225,000 180,000 26-100 1,667-6,500 0-3.0 DBS/DCS250 250,000 200,000 20-100 1,852-9,259 0-3.0 DBS/DCS300 300,000 240,000 20-100 2,222-11,111 0-3.0 DBS/DCS350 350,000 280,000 22-100 2,593-12,000 0-3.0 DBS/DCS400 400,000 320,000 25-100 2,963-12,000 0-3.0 DBS/DCS500 500,000 400,000 40-120 3,086-9,259 0-3.0 DBS/DCS600 600,000 480,000 40-120 3,704-11,111 0-3.0 DBS/DCS700 700,000 560,000 40-120 4,321-12,963 0-3.0 DBS/DCS800 800,000 640,000 41-120 4,938-14,500 0-3.0 DBS/DCS840 1,050,000 840,000 60-120 6,481-12,963 0-3.0 DBS/DCS900 1,200,000 960,000 63-120 7,407-14,500 0-3.0 ➀ Ratings are shown for elevations up to 2000 feet. Cooling Coil Performance Data Cooling Coil Model No. Maximum CFM Max. Cooling Tons ➁ DX Coil➂ Chilled Water Coil➂ 75 1,891 9.38 10.56 100/125 2,206 11.43 12.62 150/175 2,521 13.42 14.77 200/225 3,352 18.12 19.28 250/300 3,724 20.24 21.33 350/400 5,214 27.26 29.25 ➁ ➂ 1 Ton = 12,000 Btu/Hr Based on 95 F entering dry bulb, 75 F entering wet bulb Request Catalog 5-173 For Complete Technical Information and Specifications. 7

WEATHERHAWK TM WEATHERPROOF GAS-FIRED DUCT-FURNACE HEATING AND/OR MAKE-UP AIR UNITS Low Initial Cost Applications Cover Heating and/or Make-Up Air 75,000 to 400,000 Btu/Hr Input Capacity Low Maintenance Easy to Service The Modine WeatherHawk weatherproof duct furnace was designed for use with a building s heating, heating/cooling and make-up air systems. Available in 11 gravity or power vented model sizes, the unit covers a wide variety of applications. They have input ranges from 75,000 to 400,000 Btu/Hr and can operate on either natural or propane gas. The airflow direction can be specified when ordering the unit. The duct furnace is certified for location either upstream or downstream from cooling coils and has holes to drain any condensate that may form onto the roof. MODEL HFG C.S.A. certification bearing C.S.A. logos ETL certification All units a minimum of 80% thermal efficient 18 gauge aluminized steel cabinet with a baked-on polyester powder paint finish on exterior casing parts Certified to 3.0 W.C. external static pressure 409 stainless steel heat exchanger and burner 409 stainless steel drip pan Two-stage, mechanical modulation, and electronic modulation controls for either natural or propane gas. Building management compatible gas controls for modulation control using 0-10 Vdc or 4-20 ma input High and/or low gas pressure switches MODEL HFP Performance Data ➀ ➁ Btu/Hr Low Temperature High Temperature Model Temperature Rise Temperature Rise No. Input Output Range ( F) Range ( F) HFG/HFP75 75,000 60,000 20-60 926-2,778 20-100 556-2,778 HFG/HFP100 100,000 80,000 20-60 1,235-3,704 20-100 741-3,704 HFG/HFP125 125,000 100,000 20-60 1,543-4,630 20-100 926-4,630 HFG/HFP150 150,000 120,000 20-60 1,852-5,556 20-100 1,111-5,556 HFG/HFP175 175,000 140,000 20-60 2,160-6,481 20-100 1,296-6,481 HFG/HFP200 200,000 160,000 20-60 2,469-7,407 20-100 1,481-7,407 HFG/HFP225 225,000 180,000 20-60 2,778-8,333 20-100 1,667-8,333 HFG/HFP250 250,000 200,000 20-60 3,086-9,259 20-100 1,852-9,259 HFG/HFP300 300,000 240,000 20-60 3,704-11,111 20-100 2,222-11,111 HFG/HFP350 350,000 280,000 20-60 4,321-12,963 23-100 2,593-11,111 HFG/HFP400 400,000 320,000 20-60 4,938-14,815 27-100 2,963-11,111 ➀ Ratings are shown for elevations up to 2,000 feet. ➁ Units approved for use in California by CEC. Request Catalog 5-173 For Complete Technical Information and Specifications. 8

WEATHERHAWK TM WEATHERPROOF GAS-FIRED SYSTEM UNITS HEATING, COOLING, VENTILATING, AND MAKE-UP AIR UNITS Applications Cover Heating-Only, Heating/Ventilating, Cooling, and/or Make-Up Air 75,000 to 1,200,000 Btu/Hr Input Capacity Large Selection of Blower Fan/Drive and Motor Combination Available Easy to Service The Modine weatherproof duct furnace with blower, cooling, and/or downturn plenum sections was designed for use with a building s heating, heating/ventilating/cooling and make-up air systems. Available in 17 gravity or power vented model sizes, the unit covers a wide variety of applications. They have input ranges from 75,000 to 1,200,000 Btu/Hr and can operate on either natural or propane gas.the airflow ranges from 556 to 14,500 CFM and the airflow direction can be specified when ordering the unit. The unit can be provided with a cooling coil section with either a factory installed DX or chilled water cooling coil or the coil can be provided by others. MODEL HBG MODEL HDG MODEL HPG ETL certification of the entire system unit 18 gauge insulated aluminized steel cabinet with a baked-on polyester powder paint finish on exterior casing parts Blower performance up to 3.0 W.C. external static pressure Side or bottom (through a roof curb) gas and electrical connection access DX or chilled water section with factory installed cooling coil. Double wall construction for blower, cooling cabinet, and/or downturn plenum sections Dead-front disconnect switches Two position, modulating, building pressure sensing, three position, building management (0-10 Vdc or 4-20 ma input) damper actuators Blower and motor vibration isolation Performance Data Total Static Model Btu/Hr Btu/Hr Temperature CFM Pressure Range No. ➀ Input ➁ Output ➁ Rise Range ( F) Range (Inches w.c.) HBG/HCG/HDG/HPG75 75,000 60,000 20-100 556-2,778 0-3.0 HBG/HCG/HDG/HPG100 100,000 80,000 20-100 741-3,704 0-3.0 HBG/HCG/HDG/HPG125 125,000 100,000 20-100 926-4,630 0-3.0 HBG/HCG/HDG/HPG150 150,000 120,000 20-100 1,111-4,630 0-3.0 HBG/HCG/HDG/HPG175 175,000 140,000 23-100 1,296-5,556 0-3.0 HBG/HCG/HDG/HPG200 200,000 160,000 23-100 1,481-6,500 0-3.0 HBG/HCG/HDG/HPG225 225,000 180,000 26-100 1,667-6,500 0-3.0 HBG/HCG/HDG/HPG250 250,000 200,000 20-100 1,852-9,259 0-3.0 HBG/HCG/HDG/HPG300 300,000 240,000 20-100 2,222-11,111 0-3.0 HBG/HCG/HDG/HPG350 350,000 280,000 22-100 2,593-12,000 0-3.0 HBG/HCG/HDG/HPG400 400,000 320,000 25-100 2,963-12,000 0-3.0 HBG/HCG/HDG/HPG500 500,000 400,000 40-120 3,086-9,259 0-3.0 HBG/HCG/HDG/HPG600 600,000 480,000 40-120 3,704-11,111 0-3.0 HBG/HCG/HDG/HPG700 700,000 560,000 40-120 4,321-12,963 0-3.0 HBG/HCG/HDG/HPG800 800,000 640,000 41-120 4,938-14,500 0-3.0 HBG/HCG/HDG/HPG840 1,050,000 840,000 60-120 6,481-12,963 0-3.0 HBG/HCG/HDG/HPG960 1,200,000 960,000 63-120 7,401-14,500 0-3.0 ➀ For power exhausted units, the "G in the model number is replaced with a "P" ➁ Ratings are shown for elevations up to 2,000 feet. Cooling Coil and Evaporative Cooling Performance Data Cooling Coil Evaporative Cooling Model No. Maximum CFM Max. Cooling Tons ➂ Btu/Hr Chilled Water Maximum CFM DX Coil➃ Coil➃ Min. Max. 75 1,891 9.38 10.56 2,750 9,968 52,272 100/125 2,206 11.43 12.62 4,000 13,125 54,432 150/175 2,521 13.42 14.77 5,200 19,198 70,762 200/225 3,352 18.12 19.28 6,000 24,952 81,648 250/300 3,724 20.24 21.33 10,400 37,916 141,523 350/400 5,214 27.26 29.25 11,050 44,247 150,368 ➂ 1 Ton = 12,000 Btu/Hr ➃ Based on 95 F entering dry bulb, 75 F entering wet bulb Request Catalog 5-173 For Complete Technical Information and Specifications. 9

DIRECT-FIRED MAKE-UP AIR UNITS ETL Certified Btu/Hr Outputs from 42,000 to 7,862,000 s from 1,600 to 60,000 100% Make-Up Air and Recirculating Configurations 100% Thermal Efficiency Designed for Indoor or Outdoor Mounting Factory-Assembled Natural or Propane Gas Manifolds Modine has developed the best in direct-fired, make-up-air units - the MDB (Single and Two Speed 100% Make-Up Air) and MRB (Fresh and Return Air). These units are designed to provide an economical and efficient means of supplying tempered make-up air to a space or building. Available in eight airflow configurations, the units cover a wide variety of applications. MODEL MDB/MRB 100% thermal efficiency (92% sensible) results in lower fuel bills. Units are designed for indoor or outdoor mounting, providing flexibility in applications or design, as well as simplifying installation. Natural or propane gas manifolds are factory-assembled to provide flexible fuel options and to reduce field-installation, start-up costs and problems. Factory-wired electrical panel with numbered terminals significantly reduces start-up delays. 100% factory flame-testing eliminates the majority of field start-up problems caused by defective controls. Weatherproof roof with drip ledge provides protection from water being drawn into the unit from the roof. 18-gauge galvanized steel casing provides high corrosion protection for long life. Adjustable drives through 10 HP simplify air balancing and eliminates the need to change drives. Four access doors provide maximum access for easy adjustments and service. 22:1 firing rate turndown for optimum temperature control. V-bank filter section Inlet hood Inlet damper Discharge damper Evaporative cooling IRI and FM manifold arrangements Discharge air temperature control, space temperature control, or building management (0-10 Vdc or 4-20 ma input) control High and low gas pressure switches Internal blower and motor vibration isolation Acrylic paint finish on exterior casing parts Request Catalog 5-160 For Complete Technical Information and Specifications. 10

DIRECT-FIRED MAKE-UP AIR UNITS Performance Data Model No. MDB/MRB110 SCFM ➀ 1,600-3,300 Maximum Output (Btu/Hr) ➀ 432,400 Natural Gas Maximum Temperature Rise ( F) ➀ Total Static Pressure Range (" W.C.) 0-2.8 Horsepower Range 3/4-3 MDB/MRB112 2,000-4,700 615,800 3/4-5 MDB/MRB 3,000-6,500 851,700 0-2.6 1-5 MDB/MRB118 3,500-10,000 1,310,300 1 1/2-10 MDB/MRB120 6,000-13,500 1,769,000 2-15 MDB/MRB122 8,000-16,500 2,162,100 3-20 MDB/MRB125 10,000-21,500 2,817,300 3-20 MDB/MRB127 12,000-26,000 3,406,900 0-2.5 3-20 MDB/MRB130 14,000-30,000 3,931,100 0-2.7 5-25 MDB/MRB215 9,000-13,000 1,703,400 0-2.3 5-10 MDB/MRB218 12,500-18,500 2,424,200 5-20 MDB/MRB220 18,000-27,000 3,538,000 7 1/2-25 MDB/MRB222 25,000-33,000 4,324,200 15-30 MDB/MRB225 30,000-46,000 6,027,700 15-40 MDB/MRB230 44,000-60,000 7,862,200 0-2.7 20-50 ➀ CFM, Btu/Hr capacities & Temperature Rise vary depending on unit configuration and certification. The Maximum Temperature Rise for propane gas is 85 F. Evaporative Cooling Option Apparent Cooling Capacities - based on EAT of 85 F dry bulb and 65 F wet bulb ➁ Model No MDB/MRB110 MDB/MRB112 MDB/MRB MDB/MRB118 MDB/MRB120 MDB/MRB122 MDB/MRB125 MDB/MRB127 MDB/MRB130 MDB/MRB215 MDB/MRB218 MDB/MRB220 MDB/MRB222 MDB/MRB225 MDB/MRB230 12" Media Cooling ➂ Capacity Range (Btu/Hr) Min. Max. Min. Max. 1,600 3,300 33,178 65,578 2,000 4,700 40,608 91,876 3,000 6,500 61,560 127,764 3,500 10,000 71,064 193,320 6,000 13,500 121,824 263,898 8,000 16,500 158,976 318,978 10,000 21,500 199,800 417,960 12,000 26,000 239,760 505,440 14,000 30,000 276,696 576,720 9,000 13,000 176,904 254,124 12,500 18,500 243,000 355,644 18,000 27,000 353,808 524,880 25,000 33,000 486,000 634,392 30,000 46,000 589,680 894,240 44,000 60,000 855,360 1,153,440 ➁ The term apparent cooling is used because the cooling capacity will vary based on the entering air dry-bulb and wet-bulb temperatures, as well as the CFM through the unit. ➂ Available with CelDek or GlasDek media Request Catalog 5-160 For Complete Technical Information and Specifications. 11

The Modine brand has been the industry standard since Arthur B. Modine invented and patented the first lightweight, suspended hydronic unit heater in 1923. No other manufacturer can provide the combined application flexibility, technical expertise and fast delivery found at Modine. Consult your local Modine distributor for help in solving your indoor air problems. Products from Modine are designed to provide indoor air-comfort solutions for commercial, institutional and industrial applications. Whatever your heating, ventilating and cooling requirements, Modine has the product to satisfy your needs, including: Gas-fired unit heaters Gas-fired duct furnaces Gas-fired high-intensity infrared heaters Gas-fired low-intensity infrared heaters Steam/hot water unit heaters Steam/hot water cabinet unit heaters Steam/hot water commercial fin tube radiation Oil-fired unit heaters Electric unit heaters Indoor gravity vented single and multiple duct furnace make-up air units Indoor separated combustion single and multiple duct furnace make-up air units Outdoor single and multiple duct furnace make-up air units Direct-fired make-up air units With burner capacities up to 7,862,000 Btu/hr and air-handling capacities as high as 60,000 CFM, Modine products are compatible with every fuel type, including: Natural or Propane Gas Steam/Hot Water Oil Electric Specific catalogs and computer-generated heat-loss calculations are available for each product. Catalogs 75-136 and 75-137 provide details on all Modine HVAC equipment. Distributed By: Commercial HVAC&R Division Modine Manufacturing Company 1500 DeKoven Avenue Racine, Wisconsin 53403-2552 Phone: 1.800.828.4328 (HEAT) Fax: 262.636.1665 www.modine.com Modine Manufacturing Company 2004 C5/04-20M Litho in USA