EN Operating manual. thermio TM eco QE1/QE2

Similar documents
INSTALLATION AND USER INSTRUCTIONS TOWERCHRON QE1/QE2. WA-EKF 4042/05.01/S:MMS/D:Bau/00/00344/

ES3247B. 3 Channel Programmer. User and Installation Instructions

TWIN CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

3 Channel Multi-Purpose Programmer User Instructions

102E7. Installation & User Instructions. 7-day electronic mini-programmer for controlling hot water and heating

103E5. Installation & User Instructions. Electronic timeswitch for controlling hot water and heating. including Factory Replacement Units (FRU)

EUROSTER 2510 USER MANUAL 1 EUROSTER 2510

Electronic timeswitch

CentaurPlus ZW and HRT4-ZW

Electronic Dual Cylinder Thermostat Installation Instructions

User Manual THR870CUK Programmable Thermostat

Installation, Start-Up, and Operating Instructions

Room Sensor [RBT-3C] Installation Instructions

Smartfit S Pack Installation Guide with 24Hr or 7 Day Room Unit

Electronic 7 Installation Instructions

103E7. User Guide. 7-Day Electronic Timeswitch for Controlling Hot Water and Heating (Including Factory Replacement Units FRU) Danfoss Heating

For the user / for the installer. Instructions for Use and Installation. time SWITCH hour time clock

Mynute. Standard efficiency system boiler 12e - 16e - 20e. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

For the owner and the heating engineer. Operating and Installation Manual. timeswitch 140. Two-channel 5/2 or 7-day full programmer

RT021 User and Installation Instructions

lightwaverf Boiler Switch Model No. JSJSLW920 Instruction Manual Professional Series

Heating Controls Technical

MAKING MODERN LIVING POSSIBLE. FP975 7-Day Electronic Programmer. User Guide. Danfoss Heating

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

User Manual THR872CUK Wireless Programmable Thermostat

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

turbomax plus and thermocompact

MAKING MODERN LIVING POSSIBLE. SET 1E Electronic Timeswitch for Heating and Hot Water. Installation Guide. Danfoss Heating

SINGLE CHANNEL DUAL CHANNEL

MAKING MODERN LIVING POSSIBLE. SET 3E Electronic 24 Hour Programmer for Heating and Hot Water. Installation Guide. Danfoss Heating

Vokèra OpenTherm 711 without external sensor connected

Vokèra OpenTherm 711 with external sensor connected

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

ROBERTS. FM / MW dual alarm clock radio with instant time set. Please read this manual before use

CentaurPlus C27 Series 2 User Operating Instructions

PRECISION CONTROL FROM MYSON PLUS

Owners Manual. HTC621W 7-Day Programmable Thermostat 3600W. HTC625W 7-Day Programmable Thermostat 4000W

CR9976 ROBERTS. Auto Set Dual Alarm CD Clock Radio. Sound for Generations. Please read this manual before use

Operating your heating system with the Prefect PRE5701 Programable Thermostat

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

Installation & User Instructions

Installation, Start-Up, and Operating Instructions

CentaurPlus C21 Series 2 User Operating Instructions

SC Installation, Operation & Application Guide

Wireless Solutions. Wireless Heating Control Products

Drayton Digistat +3RF

GeyserWise MAX. Thermostat instruction manual. SANS 181 compliant. All in one hot water management

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

425 series Electro-mechanical Programmers

Room thermostat with 24-hour time switch and large LCD

Owner s Manual. Part Number 33CS250-01

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Owner s Manual. Part Number 33CSSP2-FC BACK LIT LIQUID CRYSTAL DISPLAY MODE BUTTON

unistor Instructions for Installation and Use Unvented hot water storage cylinder

Installation and User Guide. Electro-mechanical 24 hour timeswitch for controlling hot water and heating (Including Factory Replacement Units FRU)

Owner s Manual. Part Number 33CS250-RC

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH)

G a

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

MagicStat CT3300 Programmable Thermostat

Room thermostat with Auto Timer, Option External Input

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

TB8220U Commercial Programmable Thermostat OWNER S GUIDE

Nu-Heat UNDERFLOOR & RENEWABLES

VIESMANN. Operating instructions DIGITAL TIME SWITCH. for the system user. Digital time switch for the Vitodens 100-W, type WB1B

Owner s Manual. Part Number 33CS250-FS and 33CS220-FS

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

ET4 heat/cool day RF programmable room thermostat. ET4 Receiver

INSTRUCTIONS FOR INSTALLATION AND SERVICING ECOmax VUW 236 EH G.C. No

EUROSTER 1100E USER MANUAL 1 EUROSTER 1100E

ST9000 FAMILY OF TIMERS & PROGRAMMERS FEATURES APPLICATIONS PRODUCT SPECIFICATION SHEET

ESCTDEB. Electronic Dual Cylinder Thermostat* User and Installation Instructions. Patent pending

CT2800 Programmable Thermostat

COMF RT SYSTEM. T-32-TS Touchscreen Thermostat. User Manual

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology. with SFT (Smart Fan Technology )

SC Installation, Operation & Application Guide

Maincor Air Temperature Controls AIR TEMPERATURE CONTROL

SC Installation, Operation & Application Guide

ES-LCD User Control SD Card Location

Unvented Hot Water Storage Cylinders Installation and Maintenance Instruction Manual

ESi CONTROLS BROCHURE LANDSCAPE V5.indd 1 14/08/ :31

ST9400A User Guide. Features

IR PANEL HEATER MANUAL

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual

Quick start guide. Connected wireless room thermostat. Logic Combi C / Logic Max Combi C / Vogue Gen 2 Combi / Vogue Max Combi

Operating Instructions Model: PRT-TS WiFi RF. 01/13 Version 1 Ref: PRT-TSWIFI RF

Operating instructions

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Operating instructions

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

ecotec plus 937 Power store high efficiency combination boiler

Cat No. 099A. Digital Programmable Thermostat for Weekday/Weekend Setting. User Maunal

SAT-3 Room Temperature Controller

Smart Temp. Model

Operating instructions

: PRT / PRT PRT / PRT-N1

Transcription:

Operating manual thermio TM eco QE1/QE2

! This manual ensures safe and efficient use of the thermio TM eco QE1 / QE2 timeswitches. This manual is a component of the device and must remain accessible at all times for everyone who uses the device. Everyone who uses the device must have read and understood this manual before commencing any work. The basic prerequisite for working safely is compliance with all safety instructions and usage instructions specified in this manual. Furthermore, the local accident prevention regulations and the general safety regulations apply for the operating area of the device. Copyright This manual is copyright protected. Handover this manual to third parties, reproductions of any type and form including excerpts and use and/or disclosure of the content without the written permission of Grässlin GmbH (referred to as manufacturer in the following), except for internal purposes, is not permitted. Violations will result in liability for compensation. The manufacturer reserves the right to assert additional claims. The copyright is held by the manufacturer. 2

The copyright is held by the manufacturer. Grässlin GmbH Bundesstr. 36 78112 St. Georgen GERMANY Declaration of conformity and download instructions The declaration of conformity for the device described in this manual, a download of the manual, and the technical data can be found at www.graesslin.de. 3

Table of Contents Safety Information... 5 Technical Data... 6 Installation... 7 Application / Programming QE1... 9 Application / Programming QE2... 26 4

Safety Information WARNING Risk of death due to electrical shock! Incorrect assembly and installation of the device can result in life-threatening electrical voltages. ZZThis product should be installed by a qualified installer according to current installation standards. 5

Technical Data Dimensions 156x85x42 [mm] Power supply 240V/50Hz Rating 5A (2A)/240V, per channel Memory locations 28 per channel Battery permanently fixed re-chargeable (not replaceable) Battery reserve 500 hours plus (after 70 hours charge) Installation double insulated Fitting surface mounted or single gang plaster depth socket outlet Maximum ambient temperature 50 C Type 1 Action type 1B Micro disconnection type 1B Pollution protection normal pollution situation You can find the technical data for the devices that are described in this manual at: www.graesslin.de/technical-data 6

Installation Remove QE1/QE2 from packing and prepare it for use on fully pumped or for gravity hot water systems. For gravity hot water systems no action is required. For fully pumped systems the switch located at the rear of the QE2 must be moved to the rightinto the fully pumped position. 7

NB Installation must be carried out by a qualified electrician and conform to current IEE Regulations. NB Mains supply must be suitably fused (usually 3 amps) and provision made for Class A circuit disconnection. NB Control is suitable for fixed wiring only. NB If the unit is to be surface wired: - Remove backplate by slackening fixing screw and separate the plate from the timeswitch - Remove the knock-out from the backplate and the timeswitch - Screw backplate to wall with counter sunk No. 8. Wood screws, using fixing holes provided. NB For socket box mounting: - Use the centre two holes and fit backplate to box using machine screws - To ensure clearance for the down flap, ensure that there is a minimum of 4 cm clearance under the unit when mounted 8

Application / Programming QE1 Application QE1... 10 Programming QE1... 11 Setting current time and day... 11 Start the inbuilt standard program... 12 View the inbuilt standard program... 13 Setting your own time program... 14 View/modify/delete your entered program selections... 16 Manual override functions (boost, advance, constant, OFF)... 17 Internal wiring diagram... 19 General installation instructions... 20 Wiring installation instructions... 21 9

Application QE1 Any simple time switching application up to the stated rating Domestic heating systems where both heating and hot water services are required to switch ON and OFF at the same time Controlling a combi or combination boiler 10

Programming QE1 Setting current time and day Open the keypad cover Make sure that the slide switch is on position SET TIME AND DAY to left. If the battery is in a fully discharged condition at the moment of installation then the screen will be blank. The screen will start to display approximately 2 minutes after plugging into mains supply. Now operate the RESET button. Press the RESET button with a dull pointed instrument once Press the DAY button until the actual day is marked Repeatedly press HOUR +/-, then MINUTES +/- buttons until current time is displayed. If you are setting the clock in wintertime (GMT): The clock is now correctly correctly set. If you are setting the clock in summertime (BST): Press the SUMMER/WINTER button once. The arrowhead at the bottom of the display moves to indicate Summertime, and the clock is correctly set.. 11

Start the inbuilt standard programm Move the slide switch to position RUN PRESET PROGRAM. The inbuilt standard program is now active. 12

View the inbuilt standard programm Make sure that the slide switch is on position RUN PRESET PROGRAM. Repeatedly press the VIEW PRESET button Each press displays, one step at a time, the ON and OFF times for heating and hot water. Standard program is shown in the table. ON OFF ON OFF Monday to Friday 6.30 a.m. 8.30 a.m. 4.30 p.m. 10.30 p.m. Saturday to Sunday 8.00 a.m. 11.00 a.m. 4.00 p.m. 11.00 p.m. To return to time of day Press the CLEAR button The preset programm is activated 13

Setting your own time programm It is recommended that you write down the switching times. The following day groups are selectable: Mon...Fri, Sat + Sun, Mon...Sat, Mon...Sun or any individual day. Move the slide switch to position SET OWN PROGRAM 1. To set ON time and day combination: Press HOUR +/- then MINUTES +/- buttons Press DAY button to select day/day groups 2. To store ON time and view the next program space Press the SELECT button 3. To set the first OFF time and day combination Press HOUR +/- then MINUTES +/- buttons (the day/day groups that were selected during ON time programming are still in memory for this OFF time) 14

4. To store OFF time and view the next program space Press SELECT button Repeat steps 1 to 4 to enter further ON and OFF times. 28 program spaces are available. After completing your own program: Move the slide switch to position RUN OWN PROGRAM The current time is displayed and your own program is now active. 15

View / modify / delete your entered program selections Move the slide switch to position SET OWN PROGRAM ONS To view/modify your entered ON/OFF times: Press the SELECT button repeatedly While you are viewing any program selection, you can modify the contents with the DAY, HOUR and MINUTES button. To delete your entered ON/OFF times: Press the SELECT button repeatedly until the desired ON or OFF time to be deleted appears. Press the CLEAR button. The selection displayed will be deleted. To return time of day: Move the slide switch to RUN OWN PROGRAM 16

Manual Override Functions While the timeswitch is in the RUN PRESET PROGRAM or RUN OWN PROGRAM mode, and without having to open the keypad cover, you can manually override the program without disrupting the original settings by pressing the SELECT button. TMD (Timed) When the RUN PRESET PROGRAM or RUN YOUR OWN PROGRAM mode is active, the arrow points to TMD 17

BOOST To switch ON for 1 hour ADV To switch ON (or OFF) early Press the SELECT button until the arrow in the display points to BOOST Press the SELECT button until the arrow in the display points to ADV (Advance) The timeswitch will automatically return to the timed function after 1 hour. The timeswitch will automatically go back to the timed function according to the next programmed entry The timeswitch stays ON permanently until you move the arrow by using the SELECT button again. The timeswitch stays OFF permanently until you move the arrow by using the SELECT button again. CONST To switch ON permanently OFF To switch OFF permanently Press the SELECT button until the arrow in the display points to CONST (Constant) Press the SELECT button until the arrow in the display points to OFF 18

Internal Wiring Diagram OFF Carry out wiring installation using appropriate diagram as shown. When the QE1 timeswitch is to be used with a combination boiler, always refer to the boiler manufacturer instructions concerning wiring before using the information contained in this manual. In some cases, the boiler manufacturers instructions will contain information regarding removal of certain link wires and will always indicate the fuse rating for the mains electrical supply. Plug in unit and secure to the base by tightening fixing screw. ON 19

General installation Instructions The QE1 is double insulated, so earth protection is not required. However, in the backplate a terminal for earth continuity is provided which should be used if earth conductors are present in your cable. Make sure that the earth conductors are sleeved to prevent accidental contact with live parts. Fixing Holes Backplate Terminal Block Earth Terminal Cable Knockout Fixing Screw 20

Wiring installation instructions Simple circuit for domestic central heating boiler with gravity hot water supply Room Stat Conversion Chart E N COM DEM SAT ACL TS 142 E 4 1 2 Drayton RTE E 4 1 2 3 Honeywell T6160B 2 1 3 4 Landis & Gyr RAD5 4 6 2 Switchmaster SRT2 5 1 3 2 Sunvic TLX2259 E 4 3 1 This diagram is correct for mains operated systems. The link wire L-3 must be fitted by the installer. QE1 is ideally suited for controlling combination boilers. The following basic circuit diagrams apply for range indicated. 21

Important Note: It is important that you always refer to the Boiler Manufacturers Instructions concerning electrical wiring before using the information contained in this manual. In some cases the Boiler Manufacturers Instructions will contain information regarding removal of certain link wires and will always indicate rtain the link fuse wires for the and main will always electrical indicate supply. the fuse for the main elec QE1 Terminals N Supply L Combination boiler model E Chaffoteaux Celtic 2.20 OFF N PH 7 del 6 ELM Leblanc GVM 420 See special circuit 0 OFF N PH 7 6 Glowworm Fuelsaver N L 8 7 Ravenheat N L C D Drayton RTE E 4 1 2 Saunier Duval SD 620F N L 2 3 Saunier Duval SD 123C N L 2 1 Saunier Duval SD 235C N L 2 1 Saunier Duval SD 135V N L 2 1 Saunier Duval SD 625M See special circuit Roomstat 22

Vaillant VCW 20/1 T3W 1MP 2R 3 4 Vaillant VCW 25/1 T3W 1MP 2R 3 4 Vaillant VCW SINE 18 T3W 1MP / N 2R / L 3 4 Vaillant VCW GB 182 EH 1 2 3 4 Vaillant VCW GB 242 EH 1 2 3 4 Vokera 18/72 MCF N L 4 5 Vokera 21/84 MCF N L 4 5 Vokera 21/84 Turbo N L 4 5 Vokera 18/72 DMCF N L 3 4 Vokera 21/84 DMCF N L 3 4 Vokera 21/84 DC Turbo N L 3 4 Vokera 20/80 RS Turbo N L 3 4 Worcester Heatslave Senior 12 N L 2 4 Worcester Heatslave Senior 20430 N L 2 4 Worcester Heatslave Senior 6 N L 2 6 Worcester Heatslave 9-24 RSF N L 1 2 Worcester Heatslave 9-24 BF N L 1 2 Worcester Heatslave 9-24 N L 1 2 Worcester Heatslave High Flow BF N L 2 2 Worcester Heatslave High Flow OF N L 2 3 23

SAUNIER DUVAL SD625M Always use the special 24V thermostat supplied with this boiler, and wire as indicated in boiler instructions, substituting time switch terminals A and B for terminals 3 and 4 respectively on QE1. Boiler with Timeswitch and Room Thermostat 24

ELM Leblanc GVM 420 25

Application / Programming QE2 Application QE2... 27 Programming QE2... 28 Setting current time and day... 28 Start the inbuilt standard program... 29 View the inbuilt standard program... 30 Setting your own heating/hot water program... 32 View/modify/delete your entered program selections... 38 Manual override functions (boost, advance, constant, OFF)... 40 General installation instructions... 42 Internal wiring diagram... 43 Wiring installation instructions... 44 26

Application QE2 Fully pumped central heating systems using mid position valves, spring return valves or power open, power closed valves. Gravity hot water, pumped heating systems with or without motorised valves fi tted into the domestic hot water primary circuit. Important note: For fully pumped systems the switch located at the rear of the QE2 must be moved to the right - into the fully pumped position. 27

Programming QE2 Setting current time and day Open the keypad cover Make sure that the slide switch is on position SET TIME AND DAY to left. If the battery is in a fully discharged condition at the moment of installation then the screen will be blank. The screen will start to display approximately 2 minutes after plugging into mains supply. Now operate the RESET button. Press the RESET button with a dull pointed instrument once Press the DAY button until the actual day is marked Repeatedly press HOUR +/-, then MINUTES +/- buttons until current time is displayed. If you are setting the clock in wintertime (GMT): The clock is now correctly correctly set. If you are setting the clock in summertime (BST): Press the SUMMER/WINTER button once. The arrowhead at the bottom of the display moves to indicate Summertime, and the clock is correctly set. 28

Start the inbuilt standard programm Move the slide switch to position RUN PRESET PROGRAM. The inbuilt standard program is now active. 29

View the inbuilt standard programm Make sure that the slide switch is on position RUN PRESET PROGRAM. Repeatedly press the COPY button Each press displays, one step at a time, the ON and OFF times for heating and hot water. Standard program is shown in the table. HEATING SIDE HOT WATER SIDE 22 30

ON and OFF times for HEATING and HOT WATER ON OFF ON OFF Monday to Friday 6.30 a.m. 8.30 a.m. 4.30 p.m. 10.30 p.m. Saturday to Sunday 8.00 a.m. 11.00 a.m. 4.00 p.m. 11.00 p.m. To return to time of day Press the CLEAR button The preset programm is activated 31

Setting your own heating / hot water program Both Heating and Hot Water will be turned ON and OFF at the same time. It is recommended that you write down the switching times (sheet attached). The following day groups are selectable: Mon...Fri, Sat + Sun, Mon...Sat, Mon...Sun or any individual day. Move the slide switch to position SET OWN PROGRAM The first program is displayed. 1. To set ON time and day combination: Press HOUR +/- then MINUTES +/- buttons Press DAY button to select day/day groups 32

2. To copy the first ON time for Hot Water: Press COPY button The arrows on the Hot Water side of the display will flash to confirm the copy instruction has been carried out. The display now jumps to the next free program space so that the OFF time can be input. Repeat steps 1 to 2 to enter further ON and OFF times. 28 program places are available. After completing your own program: Move the slide switch to position RUN OWN PROGRAM The current time is displayed and your own program is now active. 33

Setting your own heating / hot water program (Heating and hot water will be turned ON and OFF at different times). 1. Setting your own heating times: Move the slide switch to position SET OWN PROGRAM The first program is displayed. 1. To set Heating ON time and day combination: Press HOUR +/- then MINUTES +/- buttons Press DAY button to select day/day groups 2. To store Heating ON time and view the next program space Press HEATING button 34

3. To set the first Heating OFF time and day combination Press the HOUR +/- then MINUTES +/- buttons (the day/day groups that were selected during ON time programming are still in memory for this OFF time) 4. To store Heating OFF time and day combination Press HEATING button The next free program place is displayed. Repeat steps 1 to 4 to enter further ON and OFF times. After completing your own program: Move the slide switch to position RUN OWN PROGRAM The current time is displayed and your own programis now active. 35

2. Setting your own hot water times: Move the slide switch to position SET OWN PROGRAM Press the HOT WATER button. The first program place is displayed. 1. To store Hot Water ON time and day combination: Press HOUR +/- then MINUTES +/- buttons Press DAY button to select day/day groups 2. To store Hot Water ON time and view the next program space Press HOT WATER button 3. To set the first Hot Water OFF time and day combination Press HOUR +/- then MINUTES +/- buttons (the day/day groups that were selected during ON time programming are still in memory for this OFF time) 36

4. To store Hot Water OFF time and day combination: Press HOT WATER button The next free program place is displayed. Repeat steps 1 to 4 to enter further ON and OFF times. After completing your own program: Move the slide switch to position RUN OWN PROGRAM The current time is displayed and your own programis now active. 37

View / modify / delete your entered program selections Move the slide switch to position SET OWN PROGRAM To view/modify your entered ON/OFF times: To view Heating times: Press the HEATING button repeatedly To view Hot Water times: Press the HOT WATER button repeatedly While you are viewing any program selection, you can modify the contents with the DAY, HOUR and MINUTES button. 38

To delete your entered ON/OFF times: To delete Heating times: Press the HEATING button repeatedly until the desired ON or OFF time to be deleted appears. Press the CLEAR button. The selection displayed will be deleted. To delete Heating times: Press the HOT WATER button repeatedly until the desired ON or OFF time to be deleted appears. Press the CLEAR button. The selection displayed will be deleted. To return time of day: Press the RUN OWN PROGRAM button 39

Manual Override Functions While the timeswitch is in the RUN PRESET PROGRAM or RUN OWN PROGRAM mode, and without having to open the keypad cover, you can manually override the program without disrupting the original settings by pressing the SELECT button. TMD (Timed) When the RUN PRESET PROGRAM or RUN YOUR OWN PROGRAM mode is active, the arrow points to TMD 40

BOOST To switch ON for 1 hour ADV To switch ON (or OFF) early CONST To switch ON permanently OFF To switch OFF permanently Press the HEATING or HOT WATER button until the arrow in the display points to BOOST Press the HEATING or HOT WATER button until the arrow in the display points to ADV (Advance) Press the HEATING or HOT WATER button until the arrow in the display points to CONST (Constant) Press the HEATING or HOT WATER button until the arrow in the display points to OFF The programmer will automatically return to the timed function after 1 hour. The programmer will automatically go back to the timed function according to the next programmed entry The timeswitch stays ON permanently until you move the arrow by using the HEATING or HOT WATER button again. The timeswitch stays OFF permanently until you move the arrow by using the HEATING or HOT WATER button again. 41

General installation Instructions The QE2 is double insulated, so earth protection is not required. However, in the backplate a terminal for earth continuity is provided which should be used if earth conductors are present in your cable. Make sure that the earth conductors are sleeved to prevent accidental contact with live parts. Fixing Holes Backplate Terminal Block Earth Terminal Cable Knockout Fixing Screw is double insulated, so earth protection is not requ 42

Internal Wiring Diagram Carry out wiring installation using appropriate diagram as shown. Plug in unit and secure to the base by tightening fixing screw. Important note: For fully pumped systems the switch located at the rear of the QE2 must be moved to the right - into the fully pumped position 43

Wiring installation Instructions Gravity Hot Water/Pumped Heating - System with roomstat controlled pump 44

The following wiring diagrams are schematic only (for clarity the earth and neutral connections are omitted). We suggest when wiring systems, a suitable wiring centre is used. Gravity Hot Water/Pumped Heating System Two Port Valve in D.H.W. with Room and Cylinder Stats Note: Only valves with change over switches are suitable 45

Fully Pumped System using 2 Port Spring Return Fully Pumped System using 3 Port Mid-Position Valve 46

Conversion Chart for Room / Cylinder Thermostats Room Stat Conversion Chart E COM DEM SAT ACL HTS 2 RED BLK YEL Drayton CS1 E 1 2 3 Honeywell L641 A C 1 2 Landis & Gyr RAM21 1 2 3 Switchmaster SCT1 1 2 3 Sunvic SA 2451 E 3 1 2 Room Stat Conversion Chart E N COM DEM SAT ACL TS 142 E 4 1 2 Drayton RTE E 4 1 2 3 Honeywell T6160B 2 1 3 4 Landis & Gyr RAD5 4 6 2 2 Switchmaster SRT2 5 1 3 Sunvic TLX2259 E 4 3 1 47

Grässlin GmbH Bundesstraße 36 78112 St. Georgen Germany +49 (0) 7724 / 933-0 +49 (0) 7724 / 933-240 www.graesslin.de info@graesslin.de 80.10.0662.7/0317/V03