USER MANUAL OLM SERIES WARM AIR OIL FIRED FURNACE

Similar documents
OPERATING INSTRUCTIONS SMO112 WARM AIR OIL FIRED FURNACE

USER MANUAL SLO / SFLO115 SERIES OIL FIRED WARM AIR FURNACES

USER MANUAL SOM SERIES MUL-T-POISE WARM AIR OIL FIRED FURNACE

DOMESTIC WATER HEATER OIL FIRED

CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

OIL FIRED WARM AIR FURNACE. Homeowner Instructions

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

USER S INFORMATION MANUAL (2,4)SG13B

ML180UH SERIES GAS FURNACE WARNING WARNING

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

WARNING FIRE OR EXPLOSION HAZARD.

USER S INFORMATION MANUAL

LGA/LGC036, 042, 048, 060, 072 (3, 3-1/2, 4, 5, and 6 TONS) LGA/LGC090, 102, 120, 150, (7-1/2, 8-1/2, 10, and 12-1/2 TONS)

UNITARY PRODUCTS GROUP

EL195UHE SERIES GAS FURNACE WARNING WARNING

EL296UHV SERIES GAS FURNACE WARNING WARNING

WARNING FIRE OR EXPLOSION HAZARD.

AIR CONDITIONER ELECTRONIC CONTROL

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

USER S INFORMATION MANUAL

Installation Information

USER S INFORMATION MANUAL

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Quest Power Electric Heat EHS 31 Pro

User s Information Manual

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

G61MPV SERIES GAS FURNACE WARNING

GL-DEH Series Portable Dehumidifier Operating Instructions

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

EL195UH SERIES GAS FURNACE WARNING

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

ROTARY CONTROL AIR CONDITIONER

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

EL195DFE SERIES GAS FURNACE WARNING

USER S INFORMATION MANUAL

SLIDER CASEMENT AIR CONDITIONER

Owner s Manual Phoenix FireBird

Bosch 80% AFUE Gas Furnace BGS80 Model

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

user s information manual

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

Installation, Operation and Service Manual

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the


Installation Instructions

e Heater/Exhaust Fan/Light User s Guide

Corn Flame Energy Corn Stove Model 3000

OWNER S MANUAL. Important: Read carefully before assembly and use. PORTABLE CANISTER U #961A00007 ID111867

Canister Vacuum. OWNER S MANUAL Models CV520HB/HR/HY 120V., 60Hz., 10 Amps

USER S INFORMATION MANUAL

e Bath Fan with Light User s Guide

Installation instructions for Plenum-mounted add-on electric heaters

Stoneridge Fire Pit High Dining Table Assembly Instruction

HANDY/STICK 2-WAY VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H055

Fire-Water Bowls Model 100

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

Turbo Stick Vac. OWNER S MANUAL Model EP V., 60Hz., 7.5 Amps.

INFRARED RADIANT TUBE HEATER RSTP15C NATURAL GAS RSTP17C

For Models Superventor Series

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Installation Instructions

Installation & Maintenance Instructions

e Bath Fan with Light User s Guide

Wax Base Heater & Dispenser

Portable Dehumidifier with Internal Pump

Horizontal Bottle Cooler Installation and Operation Manual

USERS INFORMATION MANUAL

VSA/VSB & KSA/KSB Series Air Doors

TJERNLUND PRODUCTS, INC.

True Hepa Shark Plus Canister Vacuum Model EP238 Use and Care Instructions

USER S INFORMATION MANUAL SLP98UHV SERIES

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

e Bath Fan with Light User s Guide

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

Interrupted Ignition Series Oil Primary Control

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS

XE SERIES INDOOR INDIRECT GAS FIRED HEATING UNIT

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

OWN ER'SGUIDE READ AND SAVE THESE INSTRUCTIONS

OPERATING INSTRUCTIONS

Xaact Spot. Xaact Hot Spot

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

INFRARED RADIANT TUBE HEATER

Transcription:

USER MANUAL OLM SERIES WARM AIR OIL FIRED FURNACE Save These Instructions For Reference ALL OLM SERIES FURNACES ARE AIR CONDITIONING READY! NOTICE TO HOMEOWNER THIS FURNACE SHALL BE INSTALLED BY A CERTIFIED INSTALLER AND WHERE REQUIRED BY LAW, A LICENSED TECHNICIAN NOTICE TO HOMEOWNER IF YOUR SUMMERAIRE OLM SERIES OIL FURNACE HAS BEEN INSTALLED USING THE APPROVED SS2C TJERNLUND SIDEWALL POWER VENTOR; IT IS YOUR RESPONSIBILITY TO KEEP THE AREA AROUND THE VENT TERMINAL FREE OF ICE, SNOW, AND DEBRIS FOR SERVICE CALL: INSTALLATION INFORMATION Installing Contractor Unit Model Number Telephone Number Unit Serial Number Installation Date Summeraire Mfg. Peterborough, Ontario K9J 7B1 OCT., 2007R

OPERATING INSTRUCTIONS CAUTION: THIS FURNACEIS APPROVED FOR FUEL OIL NOT HEAVIER THAN NO. 2 DO NOT USE GASOLINE, CRANKCASE OIL, OR ANY OIL CONTAINING GASOLINE NEVER BURN GARBAGE, REFUSE OR PAPER IN THE HEATING UNIT. NEVER LEAVE COMBUSTIBLE OR OTHER MATERIALS AROUND OR NEAR THE FURNACE. IDENTIFY THE LOCATION OF YOUR BURNER / FURNACE POWER SWITCH OIL BURNER OPERATING INSTRUCTIONS Use No 2 furnace oil ONLY Do not use gasoline, crankcase oil, or any oil containing gasoline. Do not attempt to start the burner if excess oil has accumulated, when the furnace is full of vapor, or if the combustion chamber is hot. Press the burner relay reset button ONLY ONCE; if the burner fails to start, call an Oil Burner Technician. If the oil burner is to be shut off for any period of time, shut the oil valve OFF at the oil tank. Do not adjust or tamper with the furnace or any of the controls Do not burn garbage or paper in this unit. Never leave paper, rags, or other combustibles around the furnace. Only qualified, or where required by law, a licensed technician shall set up this unit and adjust controls. DO NOT START THE OIL BURNER UNLESS THE BLOWER DOOR IS SECURED IN PLACE. TO TURN THE BURNER OFF Turn the main oil burner switch to OFF Set the thermostat as far below room temperature as possible. IF BURNER IS TO BE SHUT OFF FOR AN EXTENDED PERIOD. Turn main oil burner switch to OFF. Close all oil supply valves. The heating system should be checked and cleaned if necessary. Note: Always keep oil supply valve shut off if burner is shut down for an extended period of time. BURNER FAILS TO OPERATE Always call a qualified technician. The trouble may be : Raise your thermostat to 5º C ( 10º F ) above present room temperature Make sure your Oil Burner power switch is in the ON position If you hear a hum from the oil burner, and the motor has not started, press the reset button on the burner motor once only. Blown fuse / tripped breaker in electrical panel Thermostat may be set below room temperature. Burner relay ( combustion control ) may have to be reset ( press reset once only ) Oil valve may be closed. Oil supply may be too low. Blocked flue sensor tripped If the oil burner fails to start or runs for only a few seconds, call a qualified service technician. 2

RESTARTING BURNER AFTER EXTENDED SHUT DOWN. The complete oil burner should be checked and serviced by a qualified technician. Check oil pump strainer Replace oil filter cartridge Check electrodes Oil burner motor ( see lubrication section ) Restart burner by following instructions in; STARTING THE OIL BURNER section. If your furnace has been shut off for an extended period contact your qualified service technician for start up SUMMER FAN OPERATION During summer, continuous air circulation can be obtained by pulling / sliding the manual fan switch from the Auto position to the On position DUAL AIR OPERATION This furnace is equipped with a dual ( two ) speed blower system which allows partial air distribution at all times. When the thermostat calls for Heat, the Oil Burner starts and the HIGH speed quickly distributes warm air throughout the home. When the HIGH SPEED stops, the LOW speed continues operating, circulating the air to even the temperature throughout the house. If the LOW speed feature is not required / desired, operate the small rocker switch located on the power junction box. MAINTENANCE OIL FURNACE ANNUAL SERVICE The oil burner and furnace should be thoroughly cleaned and serviced annually by a qualified service technician, and where required by law, a licensed technician. The nozzle should be changed annually - handle nozzle with care so that the inside surface tip is not scratched. The electrodes should be cleaned and adjusted (see oil burner manual with the oil burner). LUBRICATION Apply 2 3 drops of SAE 20 30 Non Detergent oil ONLY to the oil port(s) located at either end of the burner motor. Apply 2 3 drops of SAE 20 30 Non Detergent oil ONLY to the oil ports located at either end of the blower motor. DO NOT OIL THE FAN BEARINGS! CAUTION : Before cleaning, shut off electrical power supply to the furnace. 3

CLEANING OLM SERIES This furnace shall be cleaned annually. This annual service will identify if damaged or replacement parts are necessary. If cleaning is required. The following steps should be taken. Disconnect ( remove ) flue pipe. Remove flue collar panel located at the rear of the furnace. Disconnect the oil line and remove the oil burner from the furnace. Remove baffle from secondary heat exchanger Clean the secondary heat exchanger with a stiff brush and vacuum cleaner suitable for this purpose. Inspect heat exchanger prior to reassembly After cleaning is complete, replace the flue baffle, collar plate and gaskets with NEW! Replace the oil burner At the beginning of the heating season, have the complete heating system checked by a qualified mechanic, and where required by law, a licensed mechanic. NOTE: WE RECOMMEND THAT A QUALIFIED MECHANIC OR WHERE REQUIRED BY LAW, A LICENCED MECHANIC ONLY SHOULD PERFORM ALL SERVICE AND CLEANING OF YOUR SUMMERAIRE FURNACE! AIR FILTER This furnace should never be operated without filters. A DIRTY AIR FILTER CAUSES INEFFICIENCY AND HIGHER OPERATING COSTS Clean or replace filters each heating season, or as required. Filter specifications for the air filter installed in your Summeraire oil fired warm air furnace, are listed below. DO NOT SUBSTITUTE! Note: Changing the type or size of filter used in your Summeraire furnace can seriously affect the operation of the furnace! AIR FILTER SPECIFICATIONS Filter size: 20 X 20 X 1 CSA or ULC Certified/Approved Type: Throw-away/disposable USE OF FILTERS OTHER THAN THOSE SPECIFIED ABOVE, CAN CAUSE DANGEROUS ELEVATION OF FURNACE TEMPERATURES THIS IS AN UNSAFE CONDITION! DO NOT USE / INSTALL PLEATED TYPE AIR FILTERS IN THIS FURNACE! WARNING: Your furnace requires Combustion Air DO NOT close off furnace room or enclose furnace - this will starve to furnace oil burner for air necessary for combustion and could result in a dangerous situation. NOTE: IF YOUR SUMMERAIRE FURNACE IS INSTALLED WITH A SS2-C TJERNLUND SIDEWALL POWER VENTOR. IT IS THE USERS / HOMEOWNERS RESPONSIBILITY TO KEEP THE AREA AROUND THE VENT TERMINAL FREE OF ICE, SNOW AND DEBRIS! 4

WARRANTY: Summeraire Mfg. warrants that it will supply to the owner of a Summeraire Oil furnace that has been installed in Canada, a replacement Heat Exchanger (Heat Element) free of charge F.O.B. Factory, Peterborough, Ontario, Canada. If the said Heat Exchanger wears out or fails under normal use and service due to a defect in material or workmanship during the first Twenty (20) years after the date of installation and only if the following conditions have been met. 1. The furnace has been installed and maintained in accordance with accepted practices as recommended from time to time by the Heating Refrigeration and Air Conditioning Institute of Canada; The National Building Code, or CSA standard B139 by a qualified installer. 2. The furnace has been operated with an input rate not in excess of the rating and fuel as specified on the rating plate attached to the furnace. 3. The furnace has not been operated with out the use of the proper automatic limit control on the maximum warm air temperature. 4. That the furnace has not been operated without adequate air circulation over it. 5. Proof satisfactory to Summeraire Mfg., that the defect claimed has not been caused by damage to, or destruction of the furnace. 6. The furnace has remained at all times in the place of initial installation. 7. Written notification of the failure under terms and conditions of this warranty are provided no later than thirty (30) days after the expiration of this warranty whichever shall first occur. 8. No mechanically cooled air. Originating in the return air duct shall be circulated over the heat exchanger of the furnace. 9. The owner must provide proof that the appliance has been serviced annually, including annual cleaning of the complete furnace and, inspection of the heat exchanger. 10. The unit must not be installed in any structure where a corrosive atmosphere exists as may be found in dry cleaning establishments, Laundromats, Beauty Salons, etc. 11. Summeraire Mfg. shall not be responsible for any failure due to water damage and/ or Acts of God. 12. No Air Conditioning or Heat pump coil may be installed on the return air side of this furnace. This warranty expressly supersedes all other warranties and obligations of Summeraire Mfg. No person has authority to alter or modify the terms of this warranty in any manner. Summeraire Mfg. assumes no liability for consequential damages of any kind, and the purchaser, by acceptance of this Equipment assumes all liability for the consequence of its use or misuse, by the purchaser, his employee or others. This Warranty is for the benefit of the owner of the furnace and terminates in the event of any alterations not specified by Summeraire Mfg. and other than herein provided. No further or other warranty, express or implied, is granted by this warranty and no liability shall accrue for any consequential damage resulting from alleged defects in the Heat Exchanger or its component parts. Mechanical components for this furnace are covered under a five (5) year warranty. If these components fail under normal use and service within five (5) years from date of installation, the defective part will be replaced free of charge, F.O.B. our factory in Peterborough, Ontario. The Model Number and Serial Number of your Summeraire Furnace must accompany all claims for warranty. 5 F-OLM-USMAN-EN-REV4