FDOOT241-A9-Ex Multisensor fire detector

Similar documents
OOH740-A9-Ex Multisensor fire detector

OOH740-A9-Ex Multi-sensor fire detector

FDOOT241-9, FDOOT241-A, FDO241, FDT241

FDOOT221, FDO221, FDT221

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

OH720, OP720, HI720, HI722

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

FDCL221-Ex Line adapter (Ex)

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Input module, input/output module

Interbases. Sinteso FDSB221, FDSB228, FDSB229

Input module, input/output modules

Multi line separator module

OOH740, OOHC740 Automatic fire detectors

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

ASA linear smoke detector

Output module (230 V)

Mimic display driver, LED ribbon cable

DT1101A / DT1102A / DO110xA Automatic fire detectors

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

OH110, OP110, HI110 Automatic fire detectors

FDCIO223 (ES 45) Transponder

DM1131 / DM1133 / DM1134 Manual call points

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

DF1101-Ex Infrared flame detector

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

Radio fire detection system

FDCL221-M Multi line separator module

FDBZ290 Air sampling smoke detection kit

FDBZ290 Air sampling smoke detection kit

SWING radio fire detection system

FC2040. Fire control panel. Sinteso. FS20 series, MP6

FDOOT241-A9-Ex Automatic fire detector Technical Manual

DF1151-Ex Infrared flame detector

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

Fire & Security Products. Siemens Building Technologies Group

Test units and accessories

DC1192 Input /Output module

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

Fire control panels FC360

FDCW241 Radio gateway Mounting

FD20 Sinteso Detector system

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

FC724 Fire control panel

FC2020 Fire control panel

FC724 Fire control panel

FC723 Fire control panel

FC722 Fire control panel

OH110, OP110, HI110. Automatic Fire Detectors. Automatic Fire Detector For collective and conventional detector lines

Fire control panel for modernization

Test units and accessories

Test units and accessories

Fire control panels FC726 FC726-XA

Installation and Operating Instruction

Inductive slot sensor

4) Intrinsic Safety Certification

Declaration of conformity

FDM273 Radio manual call point Mounting

Synova TM product catalog.

Desigo Fire Safety intelligent detectors for complete safety

FS720 Fire detection system (marine) Technical Manual

SET-2000 Oil/Sludge 12 VDC

FDOOT221, FDOOT241-A3, FDOOT241-A4, FDOOT241-8, FDOOT241-9, FDOOT241-A9, FDO241, FDO221, FDT241, FDT221 Automatic fire detectors Technical Manual

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

IECEx Certificate of Conformity

FDA241, FDA221 Siemens ASD

AND INSTALLATION MANUAL

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

FDBZ290 Air sampling smoke detection kit Technical Manual

Borupvang Ballerup

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

FDCI221, FDCIO221 Input module, input/output module Technical Manual

OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

Technical Data. Dimensions

Room thermostat with 24-hour time switch and large LCD

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

FT2080 Fire terminal (Touch) Mounting Installation

FDA241, FDA221 Siemens ASD

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

OPTIBAR P 1010/2010 C Supplementary instructions

Smoke Detector Testing

FT2080 Fire terminal (Touch) Mounting Installation

Call stations and extensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

EU DECLARATION OF CONFORMITY

Frost Protection Thermostat

Rosemount 3490 Series

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

FDL241-9 Linear smoke detector Mounting Commissioning

Technical Data. Dimensions

Transcription:

FDOOT241-A9-Ex Multisensor fire detector ASAtechnology TM For potentially explosive areas Sinteso Collective Signal processing with ASAtechnology Multiple protocol detector (collective/fdnet-ex) Event-controlled detection behavior Early and reliable detection when fires occur Highly developed immunity to deceptive phenomena Redundant sensor system Suitable for wind speeds of 1 to 20 m/s Prepared for future requirements thanks to its programmability Communication via FDnet-Ex (addressed individually) Address automatically issued during commissioning Control Products and Systems

Properties FDOOT241-A9-Ex neural fire detector, ASA Eco-friendly Environmentally friendly processing Reusable materials Electronic parts and synthetic materials can be easily separated Environmentally friendly detector-testing without test gas Features Resistant to environmental and interfering influences such as dust, fibers, insects, moisture, extreme temperatures, electromagnetic interference, corrosive vapors, vibration, artificial aerosols, and atypical fire phenomena Shock resistant, protection against sabotage Signal processing with ASAtechnology (Advanced Signal Analysis) Time and process-dependent detection behavior High degree of immunity to faults in power electronics Protected electronics, high-quality components Sophisticated sensors and electronic monitoring Redundant, high-quality sensor system Integrated alarm indicator (AI), 360 visibility Function Functions according to the scattered light principle with two sensors, optical forward and backward scattering Opto-electronic measuring chamber which obstructs disruptive extraneous light but provides excellent detection of both light and dark smoke particles Two additional heat sensors increase the fire detector's immunity to deceptive phenomena Can be set as a multisensor smoke detector, smoke detector, or heat detector by the software Selectable detection behavior thanks to application-specific ASA parameter sets Multi-protocol: Collective/GMT (Cerberus/Siemens), SynoLINE300, and FDnet-Ex Use For early detection of flaming fires of solid and liquid substances as well as of smoldering fires For early and reliable fire detection in an environment with deceptive phenomena Can be used either addressed or collectively Efficiency on-site Exchange the detector with detector exchanger FDUD291 without resetting the parameters Exchange the detector with detector exchanger FDUD291 without a ladder at heights up to 8 m 2

Installation Installation in potentially explosive areas Easy, time-saving, and completely reliable mounting Base with stilts for surface-mounted and recess-mounted supply lines Flat base for flush mounting, only for recess-mounted supply lines Extra-long mounting slits allow existing drill holes from other systems to be reused A large opening in the detector base makes it easy to feed the cables through The detector can be screwed into the base easily either manually or using a detector exchanger The FDOOT241-A9-Ex fire detector is designed in ignition protection category 'intrinsic safety' Ex i Standards IEC 60079-0 and IEC 60079-11 provide a basis Specific national requirements always apply when creating installations in areas at risk of explosion. Addressed operation (FDnet/FDnet-Ex) The line adapter (Ex) FDCL221-Ex ensures electrical isolation of the potentially explosive areas and the areas not at risk. Area not at risk of explosion Area at risk of explosion FDnet FDnet-Ex FDnet 1 FDCL221-Ex line adapter (Ex) 2 Manual call point FDM223-Ex 3 Multisensor fire detector FDOOT241-A9-Ex Alarm 4 indicator FDAI92-Ex 5 Alarm indicator FDAI93-Ex 3

Collective Ex installation The input/output module DC1192/FDCIO223 with downstream safety barrier SB3 ensures electrical isolation of the potentially explosive areas and areas not at risk. Area not at risk of explosion Area at risk of explosion 1 2 3 4 5 6 7 8 9 10 Input/output module DC1192 Transponder FDCIO223 Zone module FDCI223 Equipotential bonding ground Alarm indicator FDAI92-Ex / FDAI93-Ex End-of-line EOL22(Ex) in the last detector Heat detector DT1101A/02A-Ex Multisensor fire detector FDOOT241-A9-Ex Smoke detector DO1101A-Ex Safety barrier SB3 Dimensions of the FDOOT241-A9-Ex up to Ø6 mm possible for surface-mounted cable entry with base FDB221, FDB201, or FDB202 with base FDB222 for flush mounting, only for recess-mounted cable entry 4

Technical data Dimensions (Ø x H) 100 x 45.7 mm Operating temperature -25 +70 C Storage temperature -30 +75 C Air humidity Communication protocol 95 % rel. (short-term moisture condensation permitted) FDnet-Ex or collective Ex Color ~RAL 9010, pure white Protection category according to EN 60529 Collective system compatibility FDnet system compatibility IP43 IP44 with sealing kit FDBZ295 CS11, FC10, XC10, and SIGMASYS FS20, AlgoRex, SIGMASYS Characteristics Ui 28 V Ii 100 ma Pi 700 mw Li negligible Ci < 0.2 nf Operating current (quiescent) 200 280 µa Ext. Alarm indicator (AI) Uo 14.2 V Io 480 ma Po 195 mw Lo < 100 µh Co < 38 nf Only for connecting passive, external alarm indicators to negligibly small inductivities and capacities Ex classification IECEx scheme Ex ia IIC T4 Ga, Ta = -35 C +70 C 94/9/EC (ATEX Directive) II 1 G Ex ia IIC T4 Ga, Ta = -35 C +70 C Ex approvals - EC-type examination certificate BVS 12 ATEX E 087 X - IECEx BVS 12.0076 X EN 54 approvals - VdS G213106 DNV GL (Marine) MEDB00003UK 14 0786 0102 FDOOT241-A9-Ex FDOOT241-A9-Ex - Smoke/heat detector for use in fire detection and fire alarm systems installed in buildings. Siemens Schweiz AG; Theilerstrasse 1a CH-6300 Zug Technical data: see doc. A6V10346580 305/2011/EU (CPR): EN 54-5 / EN54-7 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 ; 2014/34/EU (ATEX): EN 60079-0 / EN 60079-11 / EN 60079-26 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0786-CPR-21321; DoC No.: CED-FDOOT241-A9-Ex 5

Details for ordering Type Art. no. Designation Weight FDOOT241-A9-Ex S54329-F7-A1 Multisensor fire detector 0.106 kg Accessories FDBZ295 S54319-F10-A1 Sealing kit 0.062 kg You will find additional information in the following documents: - Equipment overview, doc no. 008164 - For system compatibility, see list of compatibility, doc no. 008331 - Fire alarm signal in areas at risk of explosion, doc no. 001204 - Planning, mounting/installation, commissioning, maintenance/servicing of fire detection installations FS20 and FS720 in potentially explosive areas, doc no. A6V10324618 - Safety barrier SB3 mounting instructions; doc no. 1227 - Line adapter (Ex) FDCL221-Ex, doc no. A6V10349349 - FDOOT241-A9-Ex technical manual, doc no. A6V10346580 Disposal The device is considered an electronics device for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Issued by Siemens Switzerland Ltd Division International Headquarters Theilerstrasse 1a CH-6300 Zug, Switzerland Tel. +41 58 724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2015 Technical specifications and availability subject to change without notice. Document no. Manual FD20 Edition Register 8