VIESMANN VITOLADENS 300-C Oil condensing boiler 12.9 to 28.9 kw

Similar documents
VIESMANN VITOLADENS 300-C Oil condensing boilers 12.9 to 28.9 kw

VIESMANN VITOLADENS 300-T Oil Unit condensing boiler 35.4 to 53.7 kw

VIESMANN VITOCROSSAL 300 Gas condensing boiler 787 to 1400 kw

VIESMANN VITOROND 100. Datasheet Part numbers and prices: see pricelist VITOROND 100. Cast iron low temperature oil and gas fired boiler.

VIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw

VIESMANN. Datasheet VITOMAX 200-WS. Hot water boiler for permissible flow temperatures up to 110 C 1.75 to MW

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

VIESMANN. VITOMAX 200-WS Rated heating output 1.75 to MW. Datasheet. VITOMAX 200-WS Type M250

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Installation instructions VITOCROSSAL 200. for contractors. Vitocrossal 200 Type CM2 Gas fired condensing boiler with MatriX radiant burner

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

VIESMANN. VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW.

Floorstanding Gas Condensing Boilers VITOCROSSAL 100

VIESMANN. Installation instructions VITOCROSSAL 300. for contractors. Vitocrossal 300 Type CM3 Gas condensing boiler with MatriX radiant burner

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Installation instructions VITOMAX 200-HW. for contractors

The oil condensing heating system efficient, futureproof technology with 98 percent efficiency

VIESMANN. Installation instructions VITODENS 200-W. for contractors

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

VIESMANN VITOVENT 300-F Mechanical ventilation system with heat recovery

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

The oil condensing heating system efficient, futureproof technology with 98 percent efficiency

VIESMANN. Installation and service instructions VITOTROL 300A. for contractors. Vitotrol 300A. Remote control, part no

VIESMANN. Installation instructions. Extension AM1. Safety instructions. for contractors. Part no

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Installation and service instructions VITOTROL 200 RF. for contractors. Vitotrol 200 RF. Wireless remote control for one heating circuit

VIESMANN. Operating instructions VITODENS 100-W. for the system user

VIESMANN. Installation and service instructions. Solar-Divicon SR. Safety instructions. Application. for contractors. Part no and

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

VIESMANN. Operating instructions DIGITAL TIME SWITCH. for the system user. Digital time switch for the Vitodens 100-W, type WB1B

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA

VIESMANN. Operating instructions VITODENS 111-W. for the system user

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

VIESMANN. Datasheet For part no. and prices: see pricelist VITOLIGNO 300-P. Pellet boiler 4to48kW. Vitotec folder, register 12. File in: Type VL3B

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

VIESMANN. Installation instructions. Extension EA1. Safety instructions. for contractors. Part no

VIESMANN. Service instructions VITOCROSSAL 300. for contractors. Vitocrossal 300 Type CR3 and CR37, 787 and 978 kw Gas condensing boiler

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

Pellet Boiler VITOLIGNO 300-P. Test winner Good (2.1) Pellet boiler VITOLIGNO 300-P. In the test: 10 systems 1 winner

VITOPLEX. Low temperature oil and gas fired boilers Rated output Vitoplex 100: 575 to 1750 kw Vitoplex 200: 90 to 560 kw Vitoplex 300: 80 to 1750 kw

for contractors Vitoplex 200 Type SX2A For applicability, see the last page Please keep safe.

VIESMANN. Installation instructions. Mixer extension kit. for contractors. Mixer extension kit. For one heating circuit with mixer

Vitodens 100-W. 10 Year Warranty on all stainless steel heat exchangers for gas condensing boilers up to 150 kw

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

Domestic Gas Boiler Guide

Domestic Gas Boiler Guide

VIESMANN. Service instructions. MatriX radiant burner. for contractors

Installation and maintenance instructions

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

Technical Data Manual Model Nos. and pricing: see Price List

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

VIESMANN. Service instructions VITODENS 200-W. for contractors

Oil/gas boilers and low pressure hot water boilers up to 22 MW

VIESMANN. Operating and service instructions VITOMAX 200-HW. for contractors

WOLF GAS CONDENSING BOILERS COMFORTLINE

Max-3 plus. Output range 420 to 2700 kw TopTronic E control. Steel Shell Boiler. Responsibility for energy and environment

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

VIESMANN. Operating instructions VITODENS VITOLADENS VITOPEND. for the system user

Domestic Product Guide

1 VICTRIX ZEUS Superior kw I features

and Installation Instructions The installation instructions for the Unit pressure jet oil burner is included in the pressure jet oil burner pack.

Domestic Product Guide

VIESMANN. Gas condensing boilers 87 to 1400 kw. Technical guide. VITOCROSSAL 200 Type CM2. VITOCROSSAL 300 Type CM3. VITOCROSSAL 300 Type CT3U

4FLOOR-STANDING GAS CONDENSING BOILERS

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

The iqe Boiler Range. Combination and System T Boilers.

Gas condensing technology

INSTALLATION AND OPERATION MANUAL

Natural Heat VITOCAL 300-A VITOCAL 350-A. Air source heat pumps

VIESMANN. Installation and service instructions. EHE immersion heater. for contractors. EHE immersion heater

Domestic Gas Boiler Guide

Eco Angus Wood Pellet Boilers

Vitocrossal 300, CU3A - Introduction

Condensing technology

Logamax plus GB172/GB172T. Heat is our element. Technical Guide Issue 2011/06. Fügen Sie auf der Vorgabeseite das zur Produktgruppe passende Bild ein.

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

Condensing, pre-mixed, wall-hung gas boilers with water tank

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

Hybrid solutions. Heating systems Industrial systems Refrigeration systems

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

Solar technology VITOSOL 100-F VITOSOL 200-F VITOSOL 200-T

TopGas Wall Hung Condensing Gas Boiler

High Performance Electronic Modulation Automatic Cleaning Easy Installation 4 Power Levels: 9,15,25,42kW. Pellet Boilers. Future of Ecological Heating

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

VIESMANN. Installation and service instructions VITODENS 100. for heating engineers

PRODUCT CATALOGUE

Technical guide VITOMAX 200 HS. Notes on design and operation. Vitotec technical guide folder, register 1. File in:

VIESMANN. Installation and service instructions VITODENS 111-W. for contractors

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 MODELS SEASONAL EFFICIENCY A A A A A A A

Operating instructions

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

Technical Data Manual Model Nos. and pricing : See Price List

* Automatic boiler for burning pellets with power 8kW r. The smallest, certified boiler * in Poland 8kW

VICTRIX Superior kw Export VICTRIX Superior kw X Export

Transcription:

VIESMANN VITOLADENS 300-C Oil condensing boiler 12.9 to 28.9 kw Datasheet Part no. and prices: see pricelist VITOLADENS 300-C Type BC3 Oil condensing boiler, with two- Compact blue flame burner (12.9 to 28.9 kw), for open and balanced flue operation For operation with fuel oil DIN 51603-1 EL standard, fuel oil DIN 51603-1 EL low sulphur and fuel oil DIN 51603-6 EL A Bio 10: low sulphur fuel oil EL with up to 10 % bio-components (FAME) added 9/2010

Vitoladens 300-C, type BC3 The Vitoladens 300-C is a highly efficient oil condensing boiler with flexible options for its application. Particularly compact, it is suitable both for use in new build and as a replacement for old boilers. The corrosion-resistant stainless steel Inox-Radial heat exchanger is the core of the condensing boiler. In direct connection with the biferral composite heating surface, the energy used is converted to heat efficiently and with practically no loss. The extremely economical usage of valuable fuel oil also causes fewer CO 2 emissions. This means that by operating the Vitoladens 300-C, you make your personal contribution towards actively protecting the climate. The design and characteristics of the stainless steel heat exchanger encourage the condensation of hot gases. The created condensate flushes the heating surface and produces a self-cleaning effect, which ensures a permanently high efficiency of 98 %. Longer maintenance intervals and therefore lower service costs protect your wallet. The two- Compact blue flame burner in the Vitoladens 300-C matches its output to the current heat demand, and is economical and efficient. The burner operates in balanced or open flue mode, thus allowing flexible installation for the oil condensing boiler. The Vitoladens 300-C has already won the red dot design award. All connections of the Vitoladens 300-C are at the top. It is prefitted at the factory, and takes little time to install on site. A combination with the Vitocell 300-H DHW cylinder is ideal, as it forms a single unit with the Vitoladens 300-C. If there is a legal requirement to install a neutralising system at the boiler site, there is plenty of space to do so in the boiler subframe. A Safety assembly included in standard delivery B Flue outlet and ventilation air inlet at the top C Vitotronic control unit D Integral silencer E Integral stainless steel Inox-Radial heat exchanger F Biferral composite heating surface G Two- Compact blue flame burner Highly efficient and compact floorstanding oil Unit condensing boiler Standard efficiency up to 98 % (H s )/104 % (H i ) Maximum energy utilisation with minimum dimensions Biferral composite heating surface with directly connected stainless steel Inox-Radial heat exchanger Two- Compact blue flame burner for open and balanced flue operation Quiet operation through integral silencer New Vitotronic 200 control unit that is easy to operate with plain text and graphic display All commercially available EL-type fuel oils can be used, including fuel oil DIN 51603-6-EL A Bio 10: low sulphur fuel oil EL with mixtures of up to 10 % bio-components (FAME) Easier transportation and extended handling accessories Optional space saving installation of neutralising system into boiler subframe Safety assembly part of standard delivery Test winner with the "Stiftung Warentest" [German Consumer Association] 05/2008 2 VIESMANN VITOLADENS 300-C

Specification Rated output 12.9/19.3 16.1/23.5 19.3/28.9 Rated output/burner 1st Burner 2nd Burner 1st Burner 2nd Burner 1st Burner 2nd Burner T V /T R = 50/30 C kw 12.9 19.3 16.1 23.5 19.3 28.9 T V /T R = 80/60 C kw 12 18 15 22 18 27 Product ID CE-0035 BS 104 Dimensions Total length (dimension c) mm 958 958 1076 Total width mm 638 638 638 Total height (in operation) mm 841 841 841 Height (control unit in operating position) mm 946 946 946 Plinth height mm 250 250 250 Height of the DHW cylinder, below 130 to 200 l capacity mm 655 655 350 l capacity mm 786 Total weight kg 148 148 168 Boiler with thermal insulation, burner and boiler control unit Power consumption *1-100 % of rated output W 215 234 270-30 % of rated output W 58 62 71 Appliance in standby mode W 6 6 6 Content boiler water l 42.5 42.5 55 (boiler and heat exchanger) Permiss. operating pressure bar 3 3 3 Boiler connections Boiler flow and return flat gasket G 1½ 1½ 1½ with inserts supplied Rp 1 1 1 Safety connection (safety valve) G ¾ ¾ ¾ Drain R ½ ½ ½ Condensate drain/connection Ø mm 21 21 21 Flue gas parameters *2 Temperature at 30 C return temperature C 35 40 35 at 60 C return temperature C 70 70 65 Mass flow rate for fuel oil EL kg/h 19.3 28.8 24.5 35.9 28.8 43.1 Standard seasonal efficiency [to DIN] % up to 98 (H s )/104 (H i ) at heating system temp. 50/30 C Flue outlet Ø mm 80 80 80 Ventilation air connection Ø mm 80 80 80 Available draught *3 Pa 100 100 100 mbar 1.0 1.0 1.0 *1 Standard parameter. *2 Values for calculating the size of the flue system to EN 13384 relative to 13 % CO 2 for fuel oil EL. Flue gas temperatures as an average gross value to EN 304 at 20 C combustion air temperature. *3 Observe when sizing the chimney. VITOLADENS 300-C VIESMANN 3

Specification (cont.) 80 A B D 232 C E 120 F 144 100 946 841 811 772 G 872 969 1062 E L KOA1 K 250 529 638 b c a KOA2 165-200 KOA1 H 215-250 A B C D E F G H Air vent valve Safety valve (3 bar) Connection for diaphragm expansion vessel Fill valve Ventilation air connection Flue gas connection Fixing holes for securing the transport aid (accessory) Condensate supply (subject to the neutralising system being positioned inside the plinth) K Plinth L Siphon E Drain valve KOA1 Condensate drain KOA2 Condensate drain (subject to the neutralising system being positioned inside the plinth) Boiler return Boiler flow 4 VIESMANN VITOLADENS 300-C

e f g h d Specification (cont.) M Vitocell 100-H or Vitocell 300-H Boiler return Boiler flow Dimensions Rated output (T V /T R =50/30 C) kw 12.9/19.3 16.1/23.5 19.3/28.9 a mm 582 582 700 b mm 841 841 959 c mm 958 958 1076 With DHW cylinder below litres 130 to 200 130 to 200 130 to 200 d mm 1496 1496 1496 e mm 1470 1470 1470 f mm 1427 1427 1427 g mm 1527 1527 1527 h mm 1616 1616 1616 VITOLADENS 300-C VIESMANN 5

Specification (cont.) Pressure drop on the heating water side 300 The Vitoladens 300-C is only suitable for fully pumped hot water heating systems. 200 100 80 Pressure drop in mbar 50 40 30 20 10 0.5 1 2 3 Flow rate in m³/h Minimum clearances Vitoladens 300-C 250 300 Printed on environmentally friendly, chlorine-free bleached paper 300 450 50 A Combustion chamber (required space for removal during service) B Boiler C DHW cylinder (if installed) Subject to technical modifications. Viessmann Werke GmbH&Co KG D-35107 Allendorf Telephone: +49 6452 70-0 Fax: +49 6452 70-2780 www.viessmann.com Viessmann Limited Hortonwood 30, Telford Shropshire, TF1 7YP, GB Telephone: +44 1952 675000 Fax: +44 1952 675040 E-mail: info-uk@viessmann.com 6 VIESMANN VITOLADENS 300-C