SteriTite - The Container System of Choice SteriTite Instructions for Use

Similar documents
SteriTite - The Container System of Choice SteriTite

SteriTite - The Container System of Choice SteriTite

STERITITE INSTRUCTIONS FOR USE

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

FLASH PAK STERILIZATION CONTAINER SYSTEM

AMSCO STERILIZATION CONTAINER SYSTEM User s Guide

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

Cleaning & Sterilization

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

CLEANING INSTRUCTIONS

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET. Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

Operator s Manual. Video Laryngoscope. ( Instructions for use ) Doc no: Revision 1.1 8th January 2013

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

Operating / User Manual

Aesculap Implant Systems

Reusable Laryngoscope Blades and Handles

AMSCO V-PRO MAX LOW TEMPERATURE STERILIZATION SYSTEM (For Use Outside U.S.A. Only)

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

I.F.U Re/Processing Reusable Medical Devices

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

Instructions for Use Spinal Punches IFU

User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories

RECOMMENDATIONS FOR CLEANING DEVICES

Instructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

AS Medizintechnik GmbH Sattlerstraße Tuttlingen Germany

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Purpose. Team Roles and Responsibilities. System Requirements. Instrument Processing Training

Aesculap Implant Systems

Steam Sterilization and Sterility Assurance in Health Care Facilities ANSI/AAMI ST79. Suzanne Latta, CSPDT. Education Materials Coordinator

Recommendations for cleaning, decontamination and sterilisation. devices

SBS Design Considerations for Autoclave Sterilization

DIRECTIONS FOR USE. Keeping you insafehands to avoid needlestick injuries. see for demo video

idrive Ultra Powered Stapling System

SteelcoSure Independent performance verification of your equipment and processes

Cleaning and Sterilization for Instruments & Posts

Cleaning and Sterilisation for Burs, accessories and filling material

PERFORM Operating Document

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

PICNet CONFERENCE 2013

Operator s Manual. Model G14TC-3 Disinfection Soak Station for Transesophageal Ultrasound Probes

V. Mueller. V. Mueller Reusable Devices: Cleaning and Sterilization Guide USA. Rx Only

Instructions for Use: Fiberscope and LED Light Source

Processing (cleaning, disinfection and sterilization) of instruments from Smith & Nephew Orthopaedics AG

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Electron Microscopy Sciences

V-PRO LOW TEMPERATURE STERILIZATION SYSTEMS

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

2364 Leicester Road, P.O. Box 175, Leicester, NY Phone (585) Fax (585)

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING

PINNACLE MONITOR FOR AUTOMATED ENZYMATIC CLEANING (AEC) PROCESS

KEY OPERATOR STUDY GUIDE

Processing Instructions. Cleaning so easy.

Stainless Steel Pump to dispense portions up to 2oz MODELS INCLUDE:

WAILEA OWNER S MANUAL

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

THE BASICS OF DECONTAMINATION

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Central Sterile Services Department will receive, decontaminate, process, store and/or dispense sterile and non-sterile to departments requesting.

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

PL 70 - PL 130 low temperature H 2

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

AMSCO Washer/ Disinfectors. Central Sterile Services DISCOVER POWERFUL WASHING WITH INCREASED EFFICIENCIES. One Integrated Approach to Healthcare.

Current Sterilisation Process Content of the Presentation. Content of the Presentation. Prof (Col) Dr RN Basu. Content

Operator s Manual. Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Stainless Steel Pump for use with food containers

Operator s Guide. Autoclavable Internal Handles with Integrated Paddles Rev. M

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

01694-REVC_081315_ENGLISH

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

1501 Westpark Drive, Suite 5 Little Rock, Arkansas International

OWNER S MANUAL CAVS SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

Stainless Steel Pump. Thank You MODELS INCLUDE: CP-200 CP-F FP FP-V FP-200 FP-200V FP-1½ FP-DI FPV-DI TP-V TP-200V

CLS-1450 Series Spinner Flask Instruction Manual

IMPORTANT INFORMATION ON THE DEPUY SYNTHES

OWNER S MANUAL CAVN SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

Read All Instructions Thoroughly Before Installing or Using the Disposer.

IMPORTANT PLEASE RETAIN FOR YOUR RECORDS

All Truphatek's products:

INSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS

OWNER S MANUAL AVN SERIES RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

Syrup Server. Thank You MODEL: SY MODEL: SY for purchasing this Syrup Server to heat and neatly dispense sticky syrups and sauces.

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

X99 Series. Dental Handpiece. Instruction For Use

TRADITIONAL CONCEPT INSTRUCTION MANUAL WARRANTY CERTIFICATE

AZTECA A LITRE STERILISER

Visao HIGH-SPEED OTOLOGIC DRILL CATALOG

Ultra Lightweight Household & Commercial Vacuums

AGITATOR V DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

Eliza-H 56 CEILING FAN

SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY

Transcription:

SteriTite - The Container System of Choice SteriTite Instructions for Use Product Information Case Medical provides a full range of disposables for use with its SteriTite, universal container. SCS01:SteriTite Tamper-Evident Seals (1000 per case) Disposable plastic pad lock available in blue with chemical indicator dot for steam and EtO, and red for flash sterilization. White seals are recommended for hydrogen peroxide +STERRAD and V-Pro 1. SCF01:SteriTite Disposable Paper Filters (1000 per case) 100% Cellulose and water repellant. For steam sterilization. 7.5 round with positioning hole. SCFM01:SteriTite Disposable Paper Filters (1000 per case) 100% Cellulose and water repellant. 10 4 Rectangular. For steam sterilization SCF02:SteriTite Polypro Disposable Filters (1000 per case) Hydrophobic non-woven polypropylene, highly recomended for use for steam, gas, hydrogen peroxide and STERRAD sterilization.7.5 Round SCFM02:SteriTite Polypro Disposable Filter (1000 per case) Hydrophobic non-woven polypropylene, highly recomended for use for use for steam, gas, hydrogen peroxide and STERRAD sterilization. 10 4 Rectangular. SCL01:SteriTite Dual Process Indicator Cards (1000 per case) ID card with a dual classiv chemical indicator. Use for steam sterilizaton. SCL02:SteriTite Dual Indicator Cards, Small (1000 per case) ID card with a dual classiv chemical indicator. Use with SC03M(G), SC03Q(G) & to lock MediTray case trays. Use for steam sterilization. SCI001:SteriTite Dual Process Indicator (1000 per case) A dual purpose class IV indicator strip with room for process identification. Use for steam sterilization. 8 Long with perforation may be reconfigure to two 4 long indicator strips. Place in opposing corners of inner tray. SCLH2021:SteriTite Load Cards (1000 per case) ID card. Use for STERRAD and V-Pro Sterilization. SCLH2022:SteriTite Load Cards (1000 per case) ID card. Use for STERRAD and V-ProSterilization. If you have any questions regarding Case Medical products, please contact us at Phone: (201)-313-1999 Fax: (201) 373-9090 Info@casemed.com or www.casemed.com 19 Empire Blvd, South Hackensack, NJ. 07606 Authorized representative in Europe: Medical Products International Europe Schutweg 13a 5145 NP Waalwijk, The Netherlands The CE marking certifies that the product has met EU health, safety, and environmental. C Copyright 2010 Case Medical, Inc. IFU - Case Medical Rev.M

SteriTite - The Container System of Choice MediTray Labeling THE MediTray SYSTEM WARRANTY Case Medical, Inc. s MediTray product line is guaranteed to be free of functional defects in workmanship and materials when used as directed for its intended purpose. Case Medical, Inc. will repair or replace, at their discretion, any MediTray product found to have a manufacturing defect within three years from the date of delivery at no charge to the customer. THE SteriTite SYSTEM WARRANTY Product Warranty Case Medical, Inc. s SteriTite product line is guaranteed to be free of functional defects in workmanship and materials when used as directed for its intended purpose. All SteriTite products are warranted only to the original purchaser and only against defects in workmanship or materials which under the intended use render the product inoperable. Case Medical, Inc., at its sole option and without charge will either repair or replace any SteriTite product determined to be defective in material or workmanship when used for its intended purpose. Lid gasket and filter ring gaskets are under warranty for three full years from the date of purchase. The following exclusions apply to the MediTray and SteriTite product line replacement warranty: Damage due to the use of caustic or abrasive cleaning agents. (Refer to Instructions for Use as to the proper specifications for the washing detergent. Case Medical recommends use of Case Solutions and SuperNova instrument cleaners or other ph neutral detergents). Excessive handling abuse to the container bottom, container lid or filter cover ring and improper opening techniques. (Refer to Instructions for Use as to the proper latch opening techniques). Damage from fire or other unpredictable event not under the control of Case Medical, Inc. CASE MEDICAL, INC. RETURNED GOODS POLICY Case Medical, Inc. wants full customer satisfaction with its products, promptness, and customer service. Should you encounter a situation in which you wish to return a product, please contact our Customer Service Department at 1-888-227-CASE for proper authorization. All returns must be assigned an authorization number by Case Medical, Inc. A completed Returned Goods Authorization (RGA) form must be affixed to the outside of all returned packages, showing prior cleaning and decontamination of returned merchandise. Issue of an RGA number should not be interpreted as a final credit to the customer account. Case Medical, Inc. reserves the right to evaluate incoming returns prior to issuing any customer credit. The following items are not returnable, except in the case of a manufacturing defect or product complaint: 1. Products held longer than 60 days from the date of delivery. 2. Products that have been used. 3. Custom or modified products. 4. Discontinued products no longer carried in the current Case Medical Price List. 5. Products not properly packaged for returns. Non refundable products received by Case Medical will be returned directly to the customer with a letter of explanation. The MediTray System combines unbeatable protection of sensitive instrumentation with maximum convenience. Use the inserts for the MediTray system and the SteriTite sealed container system. MediTray cases and covers must be wrapped or stored in a sealed container. THE MediTray SYSTEM WARRANTY Case Medical s MediTray product line is guaranteed to be free of functional defects in workmanship andmaterials when used as directed for its intended purpose. Case Medical, Inc. will repair or replace, at their discretion, any MediTray product found to have a manufacturing defect within three years from the date of delivery at no charge to the customer. DEVICE DESCRIPTION: MediTray is a rigid, reusable, medical sterilization packaging system validated for steam and low temperature sterilization systems. INTENDED USE: MediTray is intended to be used for the sterilization of reusable surgical instruments and medical devices in health care facilities. MediTray product may be containerized or wrapped with a FDA cleared medical wrap. Recommended for prevacuum steam sterilization of medical devices, including blades, and metal lumens of 2mm minimum diameter up to 435mm in length, and porous lumens of 3mm minimum diameter up to 400mm in length. Recommended exposure time: 4 minutes at 270 F. Minimum recommended dry time is 20 minutes. Please refer to the recommendations of your sterilizer manufacturer for specific reprocessing instructions as well as recommendations from your medical device manufacturer for material compatibility and requirements for extended sterilization cycles. Note: MediTray products may be used in steam, ETO, ozone and gas plasma (STERRAD) Sterilization. Caution: Nylon coated parts and Radel plastic cases are not recommended for STERRAD Sterilization. REPROCESSING INSTRUCTIONS Thoroughly clean and decontaminate MediTray products prior to use. Use only ph neutral detergents. Abrasive cleaners, abrasive pads, or metal brushes cannot be used. MediTray baskets and trays are recommended for automatic cleaning cycles. Be sure to follow all cleaning steps with a thorough rinse. Case Medical recommends its ph neutral Case Solutions and SuperNova cleaners for decontamination of medical devices including MediTray and SteriTite products. Dry product thoroughly before sterilization or further processing. A lint free cloth may be used for the drying process. Warning: Use of a caustic cleaner will damage the anodized surface of aluminum devices and will cause corrosion. This can void the company s warranty. All MediTray baskets, trays, and case-trays are designed with a unique patented grid pattern allowing for easy interchange of all inserts. BackBone silicone brackets can be used to elevate and secure surgical instruments. For delicate instruments which require a firm yet cushioning grip, use BackBone silicone brackets with patented inner spine. BackBone brackets have snap-in feet which attach securely to the base of your MediTray basket, tray, or case-tray, without the need for tools. To remove a BackBone Bracket, push over with your fingers or palm to remove. If necessary, compress the snap-in feet on the underside with the MediTray post tool or needle-nose pliers. MediTray metal brackets, partitions, and posts are secured with threaded nuts. Merchandise must be returned within 60 days from date of delivery. Product, which is not within the criteria of non-returnable merchandise, will be issued credit as follows: Credit will be issued for products returned in original packaging and resalable condition according to Terms and Conditions. Products returned after 30 days will be issued partial credit only. 1 14

for Amsco V-PRO1 Low Temperature Sterilization System SteriTite - The Container System of Choice DEVICE DESCRIPTION: The SteriTite container is a rigid, reusable, sealed medical sterilization packaging system. INTENDED USE: The SteriTite universal container system with MediTray products is a reusable sterilization container system used to enclose other medical devices, which are to be sterilized, transported and stored by a health care provider. The SteriTite container system is intended for use in Steris Amsco V-PRO 1 low temperature Sterilization System Lumen Cycle. SteriTite Sealed Container system is recommended for surface and stainless steel lumens (process up to 20 stainless steel lumened instruments of 3mm diameter or larger and a length up to 400 mm or shorter).please refer to the recommendations of the sterilizer manufacturer for specific processing instructions and to your medical device manufacturer for material compatibility. LOAD: The contents must be placed within an instrument basket or tray. Leave 1 of clearance in container. For example a 3 high basket may be placed within a 4 high container. SteriTite models and maximum load of contents please refer to the table below: V-PRO 1 w/ MODEL# DESCRIPTION polypropylene MA LOAD disposable filter SC05WG Wide Size 5 H - Perforated Bottom x 19.97 lbs SC08FG Full Size 8 H - Perforated Bottom x 19.97 lbs SC06FG Full Size 4 H - Perforated Bottom 19.97lbs SC04FG Full Size 4 H - Perforated Bottom 19.97lbs SC08QG 3/4 Size 8 H - Perforated Bottom x 19.97 lbs SC06QG 3/4 Size 6 H - Perforated Bottom x 19.97lbs SC04QG 3/4 Size 4 H - Perforated Bottom 15.7 lbs SC08HG 1/2 Size 8 H - Perforated Bottom x 15.92 lbs SC06HG 1/2 Size 6 H - Perforated Bottom x 13.16lbs SC04HG 1/2 Size 4 H - Perforated Bottom 9.97lbs SC03QG 3/4 Mini Size 3 H -Perforated Bottom 8.85lbs SC03MG Mini Size 3 H - Perforated Bottom 5.63 lbs DESCRIPTION PART NUMBER AMSCO V-PRO 1 BASKETS TRAYS ENDO TRAYS INSERT BOES METAL BRACKETS METAL PARTITIONS METAL POSTS SILICONE BRACKETS INSTRUMENT STRINGERS BSKH01, BSKH02, BSKH03, BSKH04, BSKQ01, BSKQ02, BSKQ03, BSKQ04, BSKF01, BSKF02, BSKF03, BSKF04 ST01, ST02, STQ1, STQ2, MT01, HT01, QT01 ENDOH1, ENDOQ1, ENDOF1, ENDOF1T456, ENDOQ2, ENDOF2 EC00, EC01, EC02, EC07, EC08, APC01, APC02, APC03, APC04 B01, B02, B03, B04, B05, B06, B07, B08, BM01, BM03, BM04 BM05, BM08, P01, P02, P03, P04, P05, P06, P07, P08 POST01, POST015, POST02, POST03 BMS01, BMS02, BMS03, BMS04, BMS05, BMS06, BMS07, BMS08, BMS10, BES170, BES171, BES001, BES002 INST06, INST09, INST012 Note: All containers for Steris Amsco V-PRO 1 low temperature Sterilization System are perforated bottom containers, which must be used with the single-use non-woven Polypro filter. The SteriTite sealed container and MediTray products are a universal reusable packaging system for medical devices to be used for all current sterilization systems, including prevacuum and gravity displacement steam, EtO, STERRAD 100, 100S, 200, N, STERIZONE 125L, AMSCO V-Pro 1, and sealed flash sterilization. The SteriTite rigid container system is available for both prevacuum and gravity displacement sterilizers. The perforated bottom containers can also be used with prevacuum sterilizers. Prevacuum containers with solid bottom cannot be used in gravity displacement sterilizers or STERRAD sterilization. The perforated bottom containers are ideal for standardization as they are validated for all current sterilization methods. Whenever a new packaging method is introduced into a health care facility, all procedures associated with its use should be carefully evaluated and adapted. For this reason, Case Medical Inc. recommends that each user of our products become familiar with the information contained in Comprehensive guide to steam sterilization and sterility assurance in Health Care Facilities and Containment devices for reusable medical device sterilization. 1 1 ANSI/AAMI ST79:2006/2008, ST77:2006 AAMI STANDARDS ORDER CODE: www.aami.org/publications/pubs.standards.html PARAMETERS FOR USE: Use nonwoven polypropylene disposable filters: Disposable nonwoven Filter # SCF02 (7.5 diameter) and SCFM02 (10 4 ) are a single use disposable medical device supplied nonsterile. In Steris Amsco V-PRO 1 low temperature Sterilization System, validation testing was performed with blades and lumens. Only stainless steel lumened instruments of 3mm diameter or larger and a length up to 400 mm should be processed. Adequate sterilant penetration and barrier properties were demonstrated using the SteriTite rigid reusable container system and MediTray products in the Steris Amsco V-PRO 1 low temperature Sterilization System under half cycle and fractional studies. Stackability of SteriTite Containers in Steris Amsco V-PRO 1: MediTray baskets and trays may be stacked within the SteriTite container system as follows: up to two (2) instrument baskets or four (4) trays may be stacked within the SteriTite container. Caution: External stacking was not tested. Please do not stack SteriTite containers on top of each other in Steris Amsco V-PRO1. Placement of SteriTite Containers in the Steris Amsco V-PRO 1 low temperature Sterilization System: Case Medical recommends that its containers be placed flat on the sterilizer shelf. All models of SteriTite containers can be placed on each of the two shelves within the Steris Amsco V-PRO 1 low temperature Sterilization System. However, only one shelf can be used to accommodate an 8" high perforated base SteriTite container, because of height restrictions within the sterilizer s chamber. MediTray Products including MediTray inserts, instrument baskets, stacking trays, BackBone silicone brackets, stainless and aluminum brackets, posts and partitions may be used in Steris Amsco V-PRO 1 low temperature Sterilization System. Caution: In Steris Amsco V-PRO 1 low temperature Sterilization System use only compatible materials and instruments as stated in the Steris Amsco V-PRO 1 low temperature Sterilization System Operating Manual. Consult with your instrument manufacturer for the compatibility of various materials in Steris Amsco V-PRO 1 low temperature Sterilization System. Refer to Steris Amsco V-PRO 1 low temperature Sterilization System Operating Manual, instructions for use and labeling. 13 2

SteriTite Decontamination: for Ozone Sterilization with disosables filter Disassemble all components. Unlatch and remove the lid of the SteriTite rigid container. Inspect the gasket in the lid for accurate fit and undamaged surface. There is no reason to remove the gasket for the cleaning procedure. Remove the filter retention plate(s) by turning the handle of the locking mechanism clockwise. Inspect the gaskets in each filter plate. Place the filter retention plate in a basket for cleaning. Note: SteriTite solid bottom containers have filters in their lid. The SteriTite container with perforated base has filters in both the lid and base. Remove the tray of instruments and prepare the instruments for decontamination following the recommendations of the instrument manufacturer. Note: In order to properly decontaminate the container, be sure to remove the filter retention plate(s) from the container lid and base and place into a basket for cleaning. DEVICE DESCRIPTION: The SteriTite container is a rigid, reusable, sealed medical sterilization packaging system. INTENDED USE: The SteriTite container system is intended for use in 125L Ozone Sterilizer for sterilization of reusable surgical instruments and medical devices in health care facilities. MediTray product may be containerized or wrapped with a FDA cleared medical wrap. Please refer to the recommendations of your sterilizer manufacturer for specific processing instructions as well as recommendations from your medical device manufacturer for material compatibility. LOAD: The contents must be placed within an instrument basket or tray. Load may be distributed in layers using MediTray baskets and trays. Leave 1 of clearance in container. AAMI recommends a maximum of 25lbs total weight. However, Case Medical validated with maximum load. For SteriTite models and maximum load of contents please refer to the table below: MODEL# DESCRIPTION MA LOAD SC05W Wide Size 5 H - Solid Bottom 22 lbs SC08F Full Size 8 H - Solid Bottom 22 lbs SC06F SC04F SC08Q SC06Q Full Size 6 H - Solid Bottom Full Size 4 H - Solid Bottom 3/4Size 8 H - Solid Bottom 3/4 Size 6 H - Solid Bottom SC04Q SC08H SC06H SC04H SC03Q SC03M 3/4 Size 4 H - Solid Bottom 1/2 Size 8 H - Solid Bottom 1/2 Size 6 H - Solid Bottom 1/2 Size 4 H - Solid Bottom Mini Size 3 H - Solid Bottom 3/4 Mini Size 3 H -Solid Bottom 3. 2. PARAMETER FOR USE: MODEL# DESCRIPTION MA LOAD SC05WG Wide Size 5 H - Perforated Bottom 22 lbs SC08FG Full Size 8 H - Perforated Bottom 22 lbs SC06FG SC04FG SC08QG SC06QG SC04QG SC08HG SC06HG SC04HG Full Size 6 H - Perforated Bottom Full Size 4 H - Perforated Bottom 3/4Size 8 H - Perforated Bottom 3/4 Size 6 H - Perforated Bottom 3/4 Size 4 H - Perforated Bottom 1/2 Size 8 H - Perforated Bottom 1/2 Size 6 H - Perforated Bottom 1/2 Size 4 H - Perforated Bottom SC03QG Mini Size 3 H - Perforated Bottom SC03MG 3/4 Mini Size 3 H -Perforated Bottom 3. 2. 125L Ozone Sterilization: Use vented or solid base container for 125L Ozone sterilization. Use MediTray products in the container to secure instrumentation. Recommended for sterilization of medical devices, including blades, and stainless steel lumened instruments of 3mm diameter or larger and a length up to 470 mm. Do not use silicone mats as it was not designed for this purpose. Slight discoloration with our device may occur in 125L Ozone sterilization. Cycle time: The sterilizer manufacturer determines 125L Ozone Sterilization cycle time. For example, the recomended exposure time is 15 minutes. Cycle temperature: between 30.8 C and 36 C (87.4 F and 96.8 F). EVENT RELATED STERILITY MAINTENENCE DATA: SteriTite containers are event related and maintain sterility during transport and multiple handling events provided that the integrity of the seal is not broken. The associated sterility maintenance test consisted of challenging the perforated bottom SteriTite container with MediTray product for 30 days real time with multiple handling events. Note: The user should contact their device manufacturer for appropriate sterilization cycle conditions. (ANSI/AAMI ST 79:2006 Comprehensive guide to steam sterilization and sterility assurance in health care facilities). Use paper or nonwoven disposable filters: Disposable paper filter # SCF01, SCF02 (7.5 diameter) SCFM01 and SCFM02 (10 4 ) are disposable medical device supplied nonsterile. Stackability of SteriTite Containers in 125L Ozone Sterilization: External Stacking: Up to three (3) containers can be stacked and processed in the 125L Ozone Sterilizer. Internal Stacking: Testing was done with up to three (3) stacked trays or baskets inside the containers. Adequate sterilant penetration and barrier properties were demonstrated using the SteriTite rigid reusable container system and MediTray products in the 125L Ozone Sterilization System under half cycle and fractional studies. Caution: In 125L Ozone process only lumened instruments of 3mm or larger and a length up to 470 mm. Caution: In 125L Ozone Sterilization use only compatible materials and instruments as stated in the Ozone 125L Operating Manual. Specifically: Consult with your instrument manufacturer as to the compatibility of various materials in Ozone 125L Sterilization. Refer to TSO3 125L Ozone System Operating Manual instructions for use and labeling. MediTray Products including MediTray inserts, instrument baskets, stacking trays, BackBone silicone brackets, stainless and aluminum brackets, posts and partitions may be used in 125L Ozone Sterilization. Caution: Do not use nylon coated brackets or silicone mat in 125L. VALIDATION TESTING: Case Medical subscribes to the overkill principle. SteriTite and MediTray products are validated under fractional and half cycle conditions. 3 12

for EO Sterilization using disosables filter SteriTite Decontamination: DEVICE DESCRIPTION: The SteriTite container is a rigid, reusable, sealed medical sterilization packaging system. INTENDED USE: The SteriTite container system is intended to be used for the sterilization of reusable surgical instruments and medical devices in health care facilities. MediTray product may be containerized or wrapped with a FDA cleared medical wrap. Please refer to the recommendations of your sterilizer manufacturer for specific processing instructions as well as recommendations from your medical device manufacturer for material compatibility LOAD: The contents must be placed within an instrument basket or tray. Load may be distributed in layers using MediTray basic trays. Leave 1 of clearance in container. AAMI recommends a maximum of 25lbs total weight. However, Case Medical validated with maximum load. For SteriTite models and maximum load of contents please refer to the table below: MODEL# DESCRIPTION MA LOAD SC05W Wide Size 5 H - Solid Bottom 22 lbs SC08F Full Size 8 H - Solid Bottom 22 lbs SC06F SC04F SC08Q SC06Q Full Size 6 H - Solid Bottom Full Size 4 H - Solid Bottom 3/4Size 8 H - Solid Bottom 3/4 Size 6 H - Solid Bottom SC04Q SC08H SC06H SC04H SC03M SC03Q 3/4 Size 4 H - Solid Bottom 1/2 Size 8 H - Solid Bottom 1/2 Size 6 H - Solid Bottom 1/2 Size 4 H - Solid Bottom Mini Size 3 H - Solid Bottom 3/4 Mini Size 3 H - Solid Bottom 2. 3. MODEL# DESCRIPTION MA LOAD SC05WG Wide Size 5 H - Perforated Bottom 22 lbs SC08FG Full Size 8 H - Perforated Bottom 22 lbs SC06FG SC04FG SC08QG SC06QG SC04QG SC08HG SC06HG SC04HG Full Size 6 H - Perforated Bottom Full Size 4 H - Perforated Bottom 3/4Size 8 H - Perforated Bottom 3/4 Size 6 H - Perforated Bottom 3/4 Size 4 H - Perforated Bottom 1/2 Size 8 H - Perforated Bottom 1/2 Size 6 H - Perforated Bottom 1/2 Size 4 H - Perforated Bottom SC03MG Mini Size 3 H - Perforated Bottom SC03QG 3/4 Mini Size 3 H -Perforated Bottom 2. 3. PARAMETERS FOR USE: EO Sterilization: SteriTite containers may be used in EO sterilization for sterilization of blades and lumens. Solid bottom containers may be used in EO pre-vacuum sterilizers. Residual analysis shows that EO and EC limits were found to be well below maximum limits after 12 hours post aeration at room temperature. Recommended exposure time in: 600 mg/liter EO gas mixture (90% CO2 / 10% EO) - 2 hours. 230 mg/liter EO gas mixture (91.5% CO2 / 8.5% EO) - 3 hours. Polymeric and porous materials may require extended EO exposure time. Items with lumens should be throughly dried for EO sterilization. In EO sterilization, metal lumened devices of 2.2mm diameter or larger and length up to 457 mm and porous lumened devices of 3mm diameter or larger and length up to 400 mm may be processed. Contact your medical device manufacturer for specific processing information. Up to three (3) containers can be stacked and processed in the EO sterilizer at one time. Do not use MediView plastic and hybrid cases in EO sterilization. EVENT RELATED STERILITY MAINTENENCE DATA: SteriTite containers are event related. Maintains sterility during transport and multiple handling events provided that the integrity of the seal is not broken. The associated tests consisted of testing samples after 90 days (real time) handling events at a health care facility. The perforated SteriTite container with MediTray product was tested in an event related study with daily handling events over a 30 to 90 day period. WARNING: Prepare complex instruments according to the instrument maker s instructions. Use of nonabsorbent tray liners can cause condensate to pool. Do not use peel pouches within sealed containers, as they cannot be placed on their side for sterilization. Stackability of SteriTite Containers in EO sterilization: Up to three (3) SteriTite containers can be stacked and processed in the sterilizer. VALIDATION TESTING: Case Medical subscribes to the overkill principle. SteriTite and MediTray products are validated in independent laboratories under fractional and half cycle conditions. Remove filter(s) and discard. Remove all other disposables including indicators, load cards, and seals and discard. Caution: Filters installed on delivery are not meant for the sterilization process. Filters are disposable and limited to single use only. Recommendation: For automated cleaning, use SuperNova ph neutral, instrument chemistries. The SteriTite Container components should be cleaned in an automatic washer/decontaminator. Always use a ph-neutral detergent and follow the washer manufactuer s instructions concerningcorrect use and secure positioning of the items. If necessary, you may clean SteriTite Container components manually with a soft lint free cloth and a ph neutral detergent. Case Solutions multi-enzymatic cleaners are ideal for medical devices and sterilization containers. Make sure to remove all detergent agent with a thorough rinsing. Detergent residues can affect coloration and the appearance of the container s surface. Lubricate latching mechanism for smooth functioning. Try to avoid water collections by washing and drying the container upsidedown. Use a soft lint free cloth to dry all components of the container. CAUTION: Do not use alkaline detergents as they will oxidize the aluminum of the container. There will be no warranty for components damaged by non-neutral ph detergents or by the use of scratch pads NOTE: Use of any non-approved tamper evident seal could damage the locking clip. 11 4

SteriTite Assembly for Use: for Flash Sterilization using FlashTite valve plate(s) Thread the guide on the SteriTite tamper evident seal through the lock holder andsecure. Repeat on both latches. An external indicator should be attached to the container at this time. Place the SteriTite Container flat on the shelf of the sterilizer cart. DEVICE DESCRIPTION: The FlashTite valve plate(s) are attachments to the SteriTite rigid reusable sealed container for pre-vacuum flash and gravity displacement flash steam sterilization cycles. INTENDED USE: The SteriTite sealed container with FlashTite valve plate(s) is intended to be used for sterilization of one instrument or instrument set in flash sterilization. NOTE: Flashed items are for immediate use only, per AAMI guidance. Product was tested for sterility maintenance for 24 hours. The FlashTite valve is recommended for one (1) year of use. Refer to expiration date on the plate for reference date to replace. Use MediTray basic trays for flash sterilization cycles. LOAD: The contents must be placed within an instrument basket or tray. FlashTite systems for gravity displacement steam flash sterilization require a load restricting basket designed to clear the FlashTite valves placed on the lid and on the base. For FlashTite models and basket insert. Please refer to the table below: Consult the recommendations of your sterilizer manufacturer s Instructions For Use for information on determining cycles. 1. Before opening the SteriTite Container always verify that: -The tamper-evident seals are intact. -The acceptability of the end point response of the external chemical indicator. -The correct set has been selected. FlashTite models for gravity displacement steam MODEL# DESCRIPTION BASKET SC08FGV Full Size 8 H - Perforated Bottom BSKF35LH SC06FGV Full Size 6 H - Perforated Bottom SC08QGV 3/4Size 8 H - Perforated Bottom SC06QGV 3/4 Size 6 H - Perforated Bottom BSKF15LH BSKQ35LH BSKQ15LH SC08HGV 1/2 Size 8 H - Perforated Bottom SC06HGV 1/2 Size 6 H - Perforated Bottom BSKH35LH BSKH15LH FlashTite models for pre-vacuum steam Either perforated bottom or solid bottom SteriTite containers may be used with FlashTite valve plate in pre-vacuum steam flash sterilization. Use MediTray basic trays for flash sterilization cycles. The SteriTite solid bottom containers including 4 high models may be used for flash sterilization with FlashTite valve plate(s) in lid. 2. Break open the seals, remove and discard. 3. Unlatch the container. Following the sterilization process, remove the container from the STERRAD and place in the storage area. If using steam sterilization, the container should be removed from the sterilizer and placed in cool down. Note: Components of the filter retention plate are spot welded together. An orange discoloration mark at the site of the weld is a normal reaction to spot welded stainless steel. Recommended inspection criteria: Verify that gaskets in the lid and in the filter retention plate(s) are pliable, without cracks or tears, and that they are all properly and firmly affixed. If the retention plate is loose, adjust the tension by pressing downward along the perimeter of the round plate, and upward or downward at the tabs located at the ends of the rectangular plate. The recommended inspection criteria should be performed after each use, because of the variables associated with cleaning agents and equipment. PARAMETERS FOR USE: Pre-vacuum Flash Sterilization: Use either vented or solid base container with the same number of FlashTite valve plate(s) as the number of vents. Recommended parameters are 3 minutes exposure for non-porous items at 270 F (132 C) and 4 minutes exposure for porous items, lumens and mixed loads at 270 F (132 C). Recommended dry time for SteriTite container with FlashTite valve plate(s): 0-3 minutes dry time in the autoclave for items processed in flash sterilization depending on the degree of dryness require. Gravity Displacement Flash Sterilization: Use only perforated bottom container. Attach FlashTite valve plate(s) over all vents. Recommended parameters are a minimum of 5 minutes exposure for non-porous items at 270 F (132 C) and minimum of 10 minutes exposure for porous items, lumens and mixed loads at 270 F (132 C). Recommended dry time: 0-3 minutes dry time in the autoclave for items processed in flash sterilization depending on the degree of dryness required. Note: Do not use the FlashTite valve with SteriTite perforated bottom models SC04HG, SC04QG and SC04FG, because of height restrictions within these containers. Do not use solid bottom SteriTite container with FlashTite valve in gravity displacement flash sterilization. Note: The evaluation of the container/sterilizer combination is especially important in gravity displacement steam sterilization because of the relative inefficiency of air removal in this sterilization process The user must review the data upon which the container manufacturer bases the recommended cycle time and must verify those results in the hospital s sterilizer. ANSI/AAMI ST79: 2006/A1:2008. Caution: When abbreviated dry time is implemented, moisture is present. Use a glove or towel when transporting hot items from the autoclave. Do not mix the FlashTite valve plate(s) with the filter retention plate(s) and disposable filter(s). Do not use the FlashTite valve plate(s) for EO or gas plasma (STERRAD) sterilization. Reprocessing Instructions: After use, disassemble and decontaminate the FlashTite valve plate with a multi-enzymatic and ph neutral detergent as you would any SteriTite component part. Thoroughly rinse and dry. Case Medical recommends that: A chemical indicator or integrator should be placed in every container for processing. Within the sealed container, place indicator in opposing corners. Case Medical recommends use of the 3M rapid read out biological indicator for verification. Note: The copper module within the FlashTite valve mechanism will darken over time. This color change will not effect the safety and effectiveness of the device. Refer to the sterilizer manufacturer s Instructions for Use for specific information as to the limitations of instrumentation, specifications and material compatibility. Complex instruments should be prepared and sterilized according to the instrument manufacturer s instructions. Contact the manufacturer of your endoscope or lumened devices when flashing. VALIDATION TESTING: Case Medical subscribes to the overkill principle. SteriTite and MediTray products are validated in independent laboratories under fractional and half cycle conditions. Verify that the filter retention post(s) in the lid and label holders on the front of the SteriTite Container are secure. Note: Testing has been completed by Case Medical, Inc that verified correct gasket operation after 100 cycles in STERRAD Sterilization. 5 10

for STERRAD Sterilization using dispoable PolyPro filter SteriTite Assembly for Use: DEVICE DESCRIPTION: The SteriTite container is a rigid, reusable, sealed medical sterilization packaging system. INTENDED USE: The SteriTite container system is intended for use in STERRAD 100, 100S, 200 and STERRAD N sterilizers for the sterilization of reusable surgical instruments (blades and lumens) and for medical devices in health care facilities. MediTray products may be containerized or wrapped with a FDA cleared medical wrap. Please refer to the recommendations of your sterilizer manufacturer for specific processing instructions and to your medical device manufacturer for material compatibility. LOAD: The contents must be placed within an instrument basket or tray. Leave 1 of clearance in container. For STERRAD 100,100S, 200, N and 100N use only perforated base SteriTite containers with polypropylene filter. Validation testing was performed with maximum STU load of 22lbs (10kg) for blades and lumens For SteriTite models and maximum load. Please refer to the table below: STERRAD 100, 100S, & 100N STERRAD N: MODEL# DESCRIPTION MA LOAD MODEL# DESCRIPTION MA LOAD SC08FG Full Size 8 H - Perforated Bottom 30.07 lbs SC04FG Full Size 4 H - Perforated Bottom 20.13 lbs SC06FG SC04FG Full Size 6 H - Perforated Bottom Full Size 4 H - Perforated Bottom 24.27 lbs 20.13 lbs SC04QG 3/4 Size 4 H - Perforated Bottom SC04HG 1/2 Size 4 H - Perforated Bottom 15.70 lbs 9.90 lbs SC08QG 3/4Size 8 H - Perforated Bottom 23.70 lbs SC03QG Mini Size 3 H - Perforated Bottom 8.8 SC06QG 3/4 Size 6 H - Perforated Bottom 22.40 lbs SC03MG 3/4 Mini Size 3 H - Perforated Bottom 5.63 lbs SC04QG SC08HG SC06HG SC04HG 3/4 Size 4 H - Perforated Bottom 1/2 Size 8 H - Perforated Bottom 1/2 Size 6 H - Perforated Bottom 1/2 Size 4 H - Perforated Bottom 15.70 lbs 15.92 lbs 13. 9.9 lbs Note: For STERRAD 100, 100S, 200, 100N all models of SteriTite perforated bottom sealed containers may be used except for the SC05WG, which does not fit the STERRAD chamber. SC03QG Mini Size 3 H - Perforated Bottom SC03MG 3/4 Mini Size 3 H - Perforated Bottom 8.8 5.63 lbs For STERRAD N Sterilization only the 2, 3 high and 4 high containers can be used due to STERRAD N size. Part number with suffix G signifies perforated bottom container. Use with non-woven Polypro filter for STERRAD Sterilization. Use nonwoven polypropylene disposable filters: PolyPro filter # SCF02 (7.5 diameter) and SCFM02 (10 4 ) a medical device supplied nonsterile. In STERRAD 100, 100S & 200 process only stainless steel lumened instruments of 3mm diameter or larger and a length up to 400 mm. In STERRAD N standard cycle, process stainless steel lumened instruments of 2mm diameter or larger and up to 400 mm in length. In STERRAD N advanced cycle, process stainless steel lumened instruments of 1mm diameter or larger and up to 500 mm in length and porous lumens (flexible endoscope) of 1mm diameter or larger and up to 850 mm in length. In the STERRAD 100N Standard cycle, process stainless steel lumened instruments of 0.7mm diameter or larger and up to 500mm in length. I n STERRAD 100N Flexible cycle, process flexible endoscopes, PE/PTFE lumened instruments of > 1.2mm x < 835 mm.sterrad Systems have pre programmed cycles for each unit. Cycle time: The sterilizer manufacturer determines STERRAD Sterilization cycle time. Caution: In STERRAD Sterilization do not use materials made of cellulose (paper filters and cotton) with SteriTite containers. Caution: In STERRAD Sterilization use only compatible materials and instruments as stated in the STERRAD Operating Manual. Consult with your instrument manufacturer as to the compatibility of various materials in STER- RAD Sterilization. Refer to ASP s STERRAD System Operating Manual, instructions for use and labeling. Internal Stacking: MediTray baskets and trays may be stacked within the SteriTite container system as follows: In STERRAD N up to two (2) instrument baskets or trays may be stacked within the SteriTite container. In the STER- RAD 200 up to four (4) instrument baskets or trays may be stacked. In STERRAD 200 & N, the following MediTray baskets are not intended to be stacked : BSKF04, BSKF06, BSKH04, BSKQ04, and BSKQ06. In addition, MediTray insert boxes are not intended to be stacked. Case Medical recommends that its containers be placed on the sterilizer shelf. External stacking was not tested. For STERRAD 100, 100S, 200 & 100N : All models of SteriTite containers, can be placed on each of the two shelves within the STERRAD 200. However, only one shelf can be used to accommodate an 8" high perforated base SteriTitecontainer, because of height restrictions within the sterilizer s chamber. For STERRAD N only 2",3 and 4" high containers will fit in the sterilizer chamber. MediTray Products including MediTray inserts, instrument baskets, stacking trays, BackBone silicone brackets, stainless and aluminum brackets, posts and partitions may be used in STERRAD Sterilization. Caution: Do not use nylon coated brackets or silicone mat.validation TESTING: Case Medical subscribes to the overkill principle. SteriTite and MediTray products are validated under fractional and half cycle conditions. 9 For SteriTite Perforated Bottom Container: Place the appropriate filter over the perforations in the base of the SteriTite Container and place the filter retention plate over the filter. Secure the filter retention plate by pushing downwards at center point (where indicated) and rotate the handle counter- clockwise to close. Use PolyPro filters SCF02, SCFM02 for STERRAD, steam, and EtO. STERRAD is a registered trademark of ASP, a division of Ethicon Arrange the clean instruments in the basket(s) according to hospital procedures.follow the recommendations provided by the instrument manufactuer. MediTray partitions, brackets and posts are recommended for easy loading and unloading as well as protection of your delicate instruments.place the prepared baskets into the base of the SteriTite Container. Place a chemical indicator in the corner of the instrument basket. An internal chemical indicator should be used within each container. It should be placed in the area of the container considered to be least accessible to sterilant penetration. The corners of the container and the underside of the lid, away from the filters, are the likeliest locations for air pockets. Place the appropriate filter over the perforations in the lid of the SteriTite Container and place the filter retention plate over the filter. Secure the filter retention plate by pushing downwards at center point (where indicated) and rotate the handle counter-clockwise to close. Note the clicking sound. Note: Rectangular filters should be used for the rectangular filter retention plates. The round filters should be used for the round filter retention plates. Place the lid on top of the base. The edge of the base will fit in the lid channel. Secure the closure by latching the lid to the base. The top of the latch fits over theridge in the lid. Push the bottom section of the latch over the lock holder. You will feel a solid click. Place the appropriate metal ID tags in the label holders located to either side of the container latches. The label holder on the right can accomodate a load card available from Case Medical, Inc. Note: The SteriTite container system with disposable filter is compatible with the STERRAD sterilization method, steam and EtO.. 6

Reprocessing Instructions and Inspecton Criteria for Steam Sterilization using disposable filter DEVICE DESCRIPTION: The SteriTite universal container is a rigid, reusable, sealed medical sterilization packaging system validated for steam and low temperature sterilization systems. INTENDED USE: The SteriTite container system is intended to be used for the sterilization of reusable surgical instruments and medical devices in health care facilities. MediTray product may be containerized or wrapped with a FDA cleared medical wrap. Please refer to the recommendations of your sterilizer manufacturer for specific reprocessing instructions as well as recommendations from your medical device manufacturer for material compatibility and requirements for extended sterilization cycles. Refer to the SteriTite Instructions for Use and the ANSI/AAMI ST79: 2006/A1:2008* Comprehensive Guide to Steam Sterilization and Sterility Assurance in Health Care Facilities for sterilization guidelines. Review the sterilizer manufacturer s operator s manual for additional detail for specific sterilizaton systems. REPROCESSING INSTRUCTIONS AND INSPECTION CRITERIA: 1. Clean after each use. Disassemble all container components. Clean manually using a soft, lint free cloth or process in an automated washer. If an automated washer is used, secure parts to avoid excess movement during processing. Make sure container latches are folded inward and handles are tucked within the racks and not protruding. The filter retention plate should be removed and placed in a basket for the cleaning process. 2. Always use a ph neutral detergent, recommended for use on aluminum. Multi-enzymatic cleaners may be used if they are ph neutral. Caution! Do not use abrasive cleaners, alkaline or acidic detergents, metal brushes or abrasive pads. 3. Rinse all components to prevent detergent residue. Dry thoroughly. 4. Do a visual inspection of all parts. Check that gaskets are properly secured and free of wear or damage. Latches should function properly. Case and lid should be free of dents, which may interfere with the seal. Be sure filter retention plate or valve plate fits securely. 5. Verify the integrity of gaskets and other component parts. 6. Remove the filter retention plate(s) by turning the handle of the locking mechanism clockwise. Adjust filter retention plate by bending down along the edge to modify the tension. 7. Replace the disposable filter after each use. 8. Secure the filter by turning handle counter clockwise. 9. Load the container with DRY surgical instruments. 10. Place chemical indicators or integrators on each level of surgical instrument tray. For SteriTite sealed containers place chemical indicators, integrators or biological indicators in corners of the basket or tray within the sealed container. 11. Secure the container by latching the lid to the base. The top of the latch fits over the ridge in the lid of the container. Push bottom section of the latch over the lock hold (clip). Thread a disposable tamper evident seal through the latching mechanism. 12. Place the proper load cards with complete information in the label holder on the right side of container latches. 13. If the containers are sterilized in an outside contract facility, they should be doubled wrapped in double plastic bags during transport. 14. Check with your sterilizer manufacturer for additional information on reprocessing sterilization containers in their sterilizer. Recommendations: Always use a ph neutral detergent for cleaning anodized aluminum sterilization containers and trays. Case Medical highly recommends its validated ph neutral Case Solutions and SuperNova instrument cleaners for decontamination of the SteriTite container system and other sealed container systems. Warning: Use of a caustic cleaner will damage the anodized surface of aluminum devices and will cause corrosion. This can void the company s warranty on its container system. Any questions about preparation and assembly should be directed to: Case Medical, Inc at 19 Empire blvd, South Hackensack NJ 07606 Phone: 1-(888)-227-CASE or (201)-313-1999. Fax: 201-313-9090 To access our website, visit www.casemed.com DEVICE DESCRIPTION: The SteriTite container is a rigid, reusable, sealed medical sterilization packaging system. INTENDED USE: The SteriTite container system is intended to be used for the sterilization of reusable surgical instruments and medical devices in health care facilities. MediTray product may be containerized or wrapped with a FDA cleared medical wrap. Please refer to the recommendations of your sterilizer manufacturer for specific processing instructions as well as recommendations from your medical device manufacturer for material compatibility. LOAD: The contents must be placed within an instrument basket or tray. The load may be distributed in layers using MediTray baskets or trays. When stacking trays, leave 1 of clearance in container. Case Medical validated maximum load of 35lbs including container and contents. AAMI recommends a maximum of 25lbs total weight based on ergonomics. For SteriTite models and maximum load of contents please refer to the table below: MODEL# DESCRIPTION MA LOAD SC05W Wide Size 5 H - Solid Bottom 22 lbs SC08F Full Size 8 H - Solid Bottom 22 lbs SC06F SC04F SC08Q SC06Q Full Size 6 H - Solid Bottom Full Size 4 H - Solid Bottom 3/4Size 8 H - Solid Bottom 3/4 Size 6 H - Solid Bottom SC04Q SC08H SC06H SC04H SC03M SC03Q 3/4 Size 4 H - Solid Bottom 1/2 Size 8 H - Solid Bottom 1/2 Size 6 H - Solid Bottom 1/2 Size 4 H - Solid Bottom Mini Size 3 H - Solid Bottom 3/4 Mini Size 3 H - Solid Bottom 2. 3. MODEL# DESCRIPTION MA LOAD SC05WG Wide Size 5 H - Perforated Bottom 22 lbs SC08FG Full Size 8 H - Perforated Bottom 22 lbs SC06FG SC04FG SC08QG SC06QG SC04QG SC08HG SC06HG SC04HG Full Size 6 H - Perforated Bottom Full Size 4 H - Perforated Bottom 3/4Size 8 H - Perforated Bottom 3/4 Size 6 H - Perforated Bottom 3/4 Size 4 H - Perforated Bottom 1/2 Size 8 H - Perforated Bottom 1/2 Size 6 H - Perforated Bottom 1/2 Size 4 H - Perforated Bottom SC03MG Mini Size 3 H - Perforated Bottom SC03QG 3/4 Mini Size 3 H -Perforated Bottom 2. 3. PARAMETERS FOR USE: Prevacuum steam sterilization: Use vented or solid base container for pre-vacuum steam. Apply paper or polypropylene disposable filter after each use. Use MediTray inserts in the container to secure instrumentation. Recommended for sterilization of medical devices, including blades, and metal lumens of 2mm minimum diameter up to 435mm in length and porous lumens 3mm minimum diameter up to 400mm in length Recommended exposure time: 4 minutes at 270 F. Minimum recommended dry time is 20 minutes. Pre-vacuum steam flash Sterilization: Use vented or solid base container for pre-vacuum steam flash sterilization. Flash sterilization is for immediate use only. Moisture may occur in flash cycles. Caution: Use a glove or towel when transporting hot items from the autoclave. Recommended exposure time: 4 minutes at 270 F (132 C) with 0-3 min dry time. User may add additional dry time for a drier outcome. Use paper disposable filters: Disposable paper filter # SCF01 (7.5 diameter) and SCFM01 (10 4 ) are disposable medical device supplied nonsterile. Note: The user should contact their device manufacturer for appropriate (extended) sterilization cycle conditions. (ANSI/AAMI ST 79:2006 Comprehensive guide to steam sterilization and sterility assurance in health care facilities. Gravity displacement steam: Use only perforated base containers for gravity displacement steam. Use MediTray basic trays in container. Select the appropriate exposure time based on load and size of container. Validation testing demonstrated kill in 15 to 25 minutes. Recommended minimum exposure time: 30 minutes at 250 F. Minimum recommended dry time 30 minutes.use of sealed containers may require additional exposure time in gravity displacement steam.stackability of SteriTite Containers in steam sterilization: Up to three (3) containers can be stacked and processed in the autoclave.warning: Prepare complex instruments according to the instrument maker s instructions. Use of nonabsorbent tray liners can cause condensate to pool. Do not use peel pouches within sealed containers, as they cannot be placed on their side for sterilization. Note: To reduce condensate formation, crack the autoclave door for 10 to 15 minutes. EVENT RELATED STERILITY MAINTENENCE DATA: SteriTite containers are event related. Maintains sterility during transport and multiple handling events provided that the integrity of the seal is not broken. The associated tests consisted of testing samples after 30 to 90 days (real time) with handling events at a health care facility. SteriTite container for pre-vacuum flash was tested after a 24 hr period. VALIDATION TESTING: Case Medical subscribes to the overkill principle. SteriTite and MediTray products are validated in independent laboratories under fractional and half cycle conditions. 7 8