An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Similar documents
Low GWP Refrigerants for Air Conditioning Applications

CHAPTER 1 INTRODUCTION

Department of MCE, Islamic University of Technology 2. Abstract

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Study of R161 Refrigerant for Residential Airconditioning

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Performance of an Improved Household Refrigerator/Freezer

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Low Global Warming Refrigerants For Commercial Refrigeration Systems

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Transcritical CO2 Bottle Cooler Development

HFO-1234yf Performance in a Beverage Cooler

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Efficiency of Non-Azeotropic Refrigerant Cycle

PERFORMANCE OF A VERY LOW TEMPERATURE REFRIGERATION SYSTEM OPERATING WITH NATURAL FLUIDS

Assessment of LPG as a possible alternative to R-12 in domestic refrigerators

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Performance Measurement of R32 Vapor Injection Heat Pump System

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Heat Exchanger Shelves For Better Temperature Control Of Food In Open-Type Display Cases

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

DEEPAK PALIWAL, S.P.S.RAJPUT

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

JJMIE Jordan Journal of Mechanical and Industrial Engineering

Chapter 2. Alternatives to HCFCs and their Characteristics

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Purdue e-pubs. Purdue University

Sub-Critical Operation of the CO2 Expander/ Compressor

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Keywords: Climate change; ozone depletion; Montreal protocol; eco-friendly refrigerant; hydrocarbon refrigerant; performance analysis.

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

The Development of the Energy-Saving Technology by the Composition Control of R407C

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

CHAPTER 1 INTRODUCTION

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

Modelling of an Integrated Supermarket Refrigeration and Heating System Using Natural Refrigerants

Performance of CO2 Cycles with a Two-Stage Compressor

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Alternative Refrigerants For Household Refrigerators

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

Air-Cooled Heat Exchanger Performance for R410A

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Performance Evaluation of a Plug-In Refrigeration System Running Under the Simultaneous Control of Compressor Speed and Expansion Valve Opening

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

High Efficiency R-134a Compressor for Domestic Refrigerator

Higher Efficiency, Lower Sound, and Lower Cost Air Conditioning Compressors: Part 1 Efficiency

A Comparison Between Refrigerants Used In Air Conditioning

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

R32 Compressor for Air conditioning and Refrigeration applications in China

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

Enhancement of COP in Vapour Compression Refrigeration System

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Performance Comparison of R32, R410A and R290 Refrigerant in Inverter Heat Pumps Application

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Design and Research of the Commercial Digital VRV Multi-Connected Units With Sub-Cooled Ice Storage System

Effects of Oil on atranscritical Carbon Dioxide Air Conditioning Systems some experiences -

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2002 An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator R. S. Agarwal Indian Institute of Technology S. Roy Indian Institute of Technology T. Sharma Indian Institute of Technology Follow this and additional works at: http://docs.lib.purdue.edu/iracc Agarwal, R. S.; Roy, S.; and Sharma, T., "An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator" (2002). International Refrigeration and Air Conditioning Conference. Paper 622. http://docs.lib.purdue.edu/iracc/622 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

R19-2 AN INVESTIGATION INTO THE INFLUENCE OF IMPROVED REFRIGERATION CYCLE AND REFRIGERANTS ON AN ENERGY EFFICIENT DOMESTIC REFRIGERATOR ABSTRACT R.S. Agarwal*, S. Roy and T. Sharma Mechanical Engineering Department Indian Institute of Technology, Delhi New Delhi - 110016, INDIA Tel: 91-11-6591120, Fax: 91-11-6526645 Email: rsarwal@mech.iitd.ernet.in Domestic refrigerator-freezers are very widely used for food preservation. There is still growing demand especially in developing countries like India. The growth rate in India for domestic refrigerators is about 15 percent. A large inventory of such appliances exists in India. In recent years, an emphasis is paid to improve the energy efficiency of domestic refrigerator-freezers have to reduce Green House Emissions. This paper presents, results of a study undertaken to look into some of the aspects, such as alternative refrigerants, liquid suction heat exchanger cycles and optimized refrigerant charge to improve energy efficiency of domestic refrigerator-freezers. Keywords: Alternative Refrigerants, domestic refrigerator, Energy Efficiency, Montreal Protocol, Kyoto Protocol, Green House Gas Emissions. INTRODUCTION Green house gas emissions and their damaging effects on the atmosphere have received increased attention following the release of scientific data by the United Nation Environmental Program (UNEP) and World Metrological Organization (WMO) that shows carbon-dioxide (CO 2 ) to be the main contributor to increased global warming. In case of the refrigeration appliances, the indirect contribution to global warming potential (GWP) resulting from the amount of CO 2 produced by the power plant in generating electricity to operate a unit over its life time. Customer expectations and competitive pressures impose an unwritten set of constraint on refrigeration appliances produced. Studies have shown that domestic refrigerators give satisfactory performance for approximately 15 years on an average. This high degree of reliability has caused consumers to expect long life and trouble-free operation from these appliances. Therefore increased costs associated with efficiency improvements must be justified on the basis of an improved environment and lower operating cost to the consumer. Unless consumers are motivated to spend more on efficiency, further improvements will be hard for the manufacturers to justify based on existing market conditions. Moreover, the demand of

electricity is much more than its availability and this energy deficit are increasing with time. So, it is a challenge for appliance manufacturers to make the appliance energy efficient. A comprehensive study is undertaken to look into the various aspects, such as increased insulation, liquid suction heat exchanger and optimized refrigerant charge, to improve energy efficiency of commercial refrigeration appliance. OPTIONS FOR REDUCING POWER CONSUMPTION Some of the options have been studied for reducing the energy consumption of the refrigeration appliances such as Insulation, modified cycles using Liquid-suction line heat exchanger and optimizing refrigerant charge, Insulation There is a heat gain from the ambient due to temperature difference between outside and inside of the cabinet. The heat leakage is reduced by providing Polyurethane foam in between. Polyurethane foam insulation minimizing the thermal losses from the cabinet. There are five low conductivity gas options viz., HCFC-141b HFC-134a HFC-245fa HFC- 365mfc cyclopentane, for closed cell foam blowing agents. Their comparative characteristics are given in Table 1. Out of these five, cyclopentane and HCFC-141b are the most commonly used foam blowing agents. HCFC-141b has little better characteristics than cyclopantane but HCFC-141b is controlled substance under Montreal Protocol. Of the remaining four gases HFC- 134a and cyclopentane are commercially available, but they have a relatively high Foam Thermal Conductivity Index. HFC-245fa and HFC-365mfc are considered as the possible alternatives because of their low thermal conductivity but they are not commercially available. Currently cyclopentane and HCFC-141b are the most commonly used foam blowing agents. Table 1: Blowing Agent Comparisons Characteristics HCFC- 141b HFC- 134a HFC- 245fa HFC- 365mfc Cyclopentane Ozone Depletion Potential 0.11 0 0 0 0 Global Warming Potential (100 years) 630 1300 820 840 11 Foam Thermal Conductivity Index 100 117 101 102 113 Refrigerator Energy Use Index 100 112 101 N.A. 110 Relative Foam Ageing Rate Base Worse Better - Worse Flammability Marginal No No Yes Yes Density Index 100 108 98-119 Compressive Strength Index 100 100 98-120 N.A.: Not Available

REFRIGERATIN CYCLES FOR DOMESTIC REFRIGERATION Various refrigeration cycles were analyzed, to achieve energy efficiency and feasible cycle. The refrigerant properties were selected in accordance with the specifications provided by the Bureau of Indian Standards (BIS) regarding a domestic refrigerator operating in Indian conditions. The following cycles were analyzed: - Liquid Suction Heat Exchanger (LSHE) Cycle The LSHE cycle is to be used with a single evaporator. This cycle employs a heat exchanger between the condenser and the evaporator outlet. Since condenser sub-cooling with evaporator superheating increases the COP of the cycle with R-134a or R-600a as the refrigerant, therefore a LSHE improves the energy efficiency of the refrigerator. Distributor Cycle It contains two evaporators and the distributor distributes the refrigerant among the freezer compartment and the fresh food freezer compartment. Alternating Evaporator Duty (AED) Cycle This cycle has two VCR loops that share a common compressor, condenser and suction line heat exchanger. Each of the refrigeration loops has a throttle valve and an evaporator. One evaporator is located in the fresh food compartment and the other is located in the freezer compartment. The solenoid valve directs the flow of the refrigerant through one loop at a time. Only one of the two compartments is cooled at a time. This cycle allows for independent temperature control of the freezer and fresh food compartments. Experiments done on this cycle have shown a COP improvement of about 8.5% over a conventional domestic refrigerator. The refrigerant used in the experiments was R-600a. Lorenz-Meutzner Cycle In this cycle, a zeotropic refrigerant mixture is used as the refrigerant. In general, domestic refrigerators are used to hold freezer temperatures near -15 C and fresh food cabinet temperatures near 3 C, which indicates that two evaporator temperature levels exist in refrigerators. By thermodynamic analysis, it is known that if the temperature difference between the evaporator and condenser is smaller, then the COP will be higher. The cooling load of the fresh food cabinet is about 60% of the total cooling load. Thus for this 60% of the total cooling load, the refrigeration cycle operates inefficiently without taking advantage of the smaller temperature lift in the fresh food cabinet. To take advantage of this temperature lift, zeotropic refrigerant mixtures can be utilized as working fluids in refrigerators. During evaporation of zeotropic refrigeration mixtures, the saturation temperature changes due to the volatility difference of pure components, which is called as temperature glide. When the air temperature in the two cabinets and the zeotropic refrigerant mixtures are well matched, the mixtures with larger temperature glide would yield a larger increase in COP, due to reduction in compressor work.

Lorenz Cycle This is a two-evaporator cycle having two heat exchangers for sub-cooling of the liquid at the condenser outlet. Ejector Cycle The ejector cycle has a second evaporator and expansion device, a separator and an ejector, apart from the simple VCR cycle components. After the first capillary, the refrigerant passes through the fresh food evaporator. At the outlet of the evaporator, the liquid refrigerant is separated from the vapor in the separator. This liquid then expands to the freezer pressure in the second capillary. The vapor at the end of the freezer evaporator enters the ejector as suction flow. The ejector combines the two flows to an intermediate pressure level. Then the refrigerant is sent to the compressor. Selection of Refrigeration Cycle The cycle selected for final analysis and design was the LSHE cycle. This was due to the following reasons: - Since the project objective was to develop a 210L domestic refrigerator, and 210L refrigerators work on a single evaporator design, the LSHE cycle was selected. The LSHE cycle required fewer changes to the existing refrigerator models. Due to ease in fabrication, industry preferred this cycle, taking into account mass production considerations. EXPERIMENTAL SET-UP In order to evaluate the performance of the prototype R-134a and R-600a refrigerators, detailed experimental studies were carried out. The tests were conducted in the test chamber at IIT Delhi. The test setup contained a constant temperature chamber, instrumentation and an automatic data acquisition system. The Baseline Refrigerator The tests were carried out on the fabricated prototype and the baseline to arrive at the comparative results. The baseline was a 210L refrigerator charged with R-12 having same specifications as the prototype viz. insulation thickness and cabinet dimensions. The baseline was charged with R-12 as the conventional refrigerator available in the Indian market in the 210L segment is charged with R-12.

Description of the Tests Different tests were carried out on the prototype and the baseline, as recommended by the Bureau of Indian Standards. The test specifications are as follows: - Rated Energy Consumption Test The purpose of this test was to lay down the maximum energy consumption for various refrigeration appliances under the standard conditions of operation. This test was conducted at an ambient temperature of 32 C. The refrigeration appliances were tested in the standard test chamber. Operating conditions were taken after the stabilized conditions were reached according to the BIS code. The mean temperature measured at the same portion of the control cycle did not vary by more than 0.5 C from the final regulated figure. The thermostat was set at the position such as to obtain the conditions as laid down in the test procedure. The refrigerator was run under no load conditions at the rated voltage of 220V± 2%. The power consumption as measured was extrapolated for 24 hours of operations. In this test, the temperatures of the freezer and cabinet were measured at different positions along with the energy consumption. Pull Down Test The purpose of this test was to check the no load pull down characteristics of the refrigeration appliances. The test was conducted at an ambient temperature of 43 C. The thermostat was set at the coldest position. The refrigerator appliances were placed in such a way that they were shielded from direct air currents of space heating/cooling system. The time required to cool down to the mean cabinet air temperature of 7 C from 43 C without the thermostat in the circuit was noted. In this test, the freezer and cabinet temperatures were measured. Ice Making Test The purpose of this test was to check the ice making capability of the refrigerator. The test was carried out at an ambient temperature of 43 C. The thermostat was set in the coldest position before starting the test. The ice trays were filled with water upto 5mm from the top and promptly placed in the evaporator after stable operating conditions were obtained. The water temperature at the moment of placing the ice tray into the freezer was 30±1 C. The contact surface of the ice trays was wetted with water to improve thermal contact. The recording of the test time was started as soon as the placement of ice tray in the freezer and continued till the formation of ice. Through out the freezing time, it was observed that the temperature in the fresh food compartment did not go below 0 C. The ice trays were examined at suitable intervals of time till the complete ice was formed and the freezing time was obtained. During this test, the temperatures of the freezer and different locations of the cabinet were measured along with the water temperature in the freezer.

TEST RESULTS This section discusses the results of experimental performance evaluation of the prototype refrigerator (charged with R-134a) and the baseline (charged with R-12). The comparative results are discussed below: - Rated Energy Consumption Test Table II gives the results of the Rated Energy Consumption Test for R-134a. Table II: Rated Energy Consumption Test Results for R-134a and R-600a Refrigerant Charge (grams) Average power consumed (Watts) Power consumed in 24 hours (kwh/day) R-12(baseline) 105 37.111 0.891 R-134a 75 29.756 0.714 R-134a 80 29.407 0.706 R-134a 85 28.448 0.683 R-134a 90 29.236 0.702 R-134a 95 29.347 0.704 Figure 1 shows the charge optimization curve for R-134a. It can be inferred from Figure 1 that the optimum charge of the refrigerant is 85 grams, having a rated energy consumption of 0.683 kwh/day, as compared to the baseline refrigerator which has an energy consumption of 0.891 kwh/day. Thus, the R-134a prototype shows an energy improvement of 23.3% over the baseline. Power consumed in 24 hours (kwhr/day) 30 29.8 29.6 29.4 29.2 29 28.8 28.6 28.4 28.2 70 75 80 85 90 95 100 Charge (gram s) Fig. 1. Charge Optimization for R-134a

Pull Down Test The pull down test was done on the prototype, having the optimum charge, for R-134a to estimate the pull down time. The pull down test was also done on the baseline and the results for both the baseline and the prototype were compared and analyzed. Table III shows the pull down test results. Time taken for bringing down the temperature of the cabinet from 43 C to 7 C is presented. Table III: Pull Down Test Results Refrigerant Optimized mass Mean ambient Time taken for pull (grams) temperature ( C) down (minutes) R-134a 85 43.9 112 R-12 105 43.9 142 It is evident from Table III that the prototype developed has performed better than the baseline in the pull down time for both R-134a. For R-134a, the time required to bring down the temperature of the cabinet from 43 C to 7 C has been reduced by 21.1% as compared to the baseline. Ice Making Test The ice-making test was conducted at an ambient temperature of 43 C on the prototype as well as the baseline. The results of the ice making tests are presented in Table IV. Table IV: Ice - Making Test Results Refrigerant Ice formation starting time Ice formation ending time R-134a 51 min 3 hrs 20 min R-12 1 hr 2min 3 hrs 40 min It can be inferred from Table IV that the prototype refrigerator having R-134a as the refrigerant takes 9.1% less time for ice formation compared to the baseline. Therefore the performance of the prototype is comparatively better than the performance of the baseline with respect to its ice formation time. CONCLUSION The demand of domestic refrigerator-freezers is increasing especially in developing countries. The energy efficiency is the key to reduce the Green House Gas emissions. The results of this study indicate that by incorporating a liquid suction heat exchanger can result in a

substantial improvement in energy efficiency of domestic refrigerator-freezer especially units operating in high ambient temperatures. REFERENCES 1. Agarwal, R.S., 2002, A Study for Improving Energy Efficiency of Commercial Refrigeration Appliances- A step towards Reducing GHG Emissions, Proc. Earth Technology Forum, Washington D.C. 2. Fujii, T., Honda, H. and Nozu, S., 1986, A method for estimating Tube Length and Pressure Drop of Air-Cooled condensers, ASHRAE Transactions, 2934, pp 3-21. 3. Lavanis, M., Haider, I. and Radermacher, R., 1998, Experimental investigation of an Alternating Evaporator Duty refrigerator/freezer, ASHRAE Transactions, vol 18, no.1, pp.1103 1111. 4. Rose, R.J., Jung, D. and Radermacher, R., 1995, Testing of domestic two evaporator refrigerators with zeotropic refrigerant mixtures, ASHRAE Transactions, vol 5, no.1, pp. 210-216. 5. The Sino-US CFC-Free Super-Efficient Refrigerator Project Progress Report: Prototype Design and Testing, 1997. 6. Thorsell, H and Peterson, B., Comparison of the refrigerants HFC-134a and CFC-12, Int. J. of Refrigeration, Vol 7, Jan 1984, pp.46-48. 7. Tomasek, M.L. and Radermacher, R., 1995, Analysis of a domestic refrigerator cycle with an ejector, ASHRAE Transactions, vol 24, no3, pp.1431 1438. 8. Tong, L.S. and Tang, Y.S., 1997, Boiling Heat Transfer and Two Phase flow, Taylor and Francis, Bristol. 9. Vineyard, E.A., Sand, J.R. and Bohman, R.H., 1995, Evaluation of design options for improving the energy efficiency of an environmentally safe domestic refrigerator freezer, ASHRAE Transactions, vol.24, no.2, pp 1422 1430..