TSR Electric Storage Heaters

Similar documents
Combined Storage and Fan Heater

TSR Electric Storage Heaters

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Contact Details. Please note that some of the contact details on this PDF document may not be current.

SP16. 08/50740/1 (UK) - Issue 1

CREDA STORAGE RADIATORS

Contact Details. Please note that some of the contact details on this PDF document may not be current.

SP420 & SP14 SP520 & SP15 SP920 & SP19. 08/19222/9 (UK) - Issue 9

FIGARO. 08/52543/0 (UK) Issue 1

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Contact Details. Please note that some of the contact details on this PDF document may not be current.

JUNEAU JUN. 08/51193/0 Issue 0

CORELLI Micro Fireplace Assembly Instructions Model: MCFP15CRO

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

Installation and technical manual

Contact Details. Please note that some of the contact details on this PDF document may not be current.

CSH COMBINED STORAGE HEATERS INSTALLATION INSTRUCTIONS AND USER GUIDE

Opti-V Fire. Model: PGF20 Instructions

Dimplex ebrochure PDF

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

OPTIMYST WALL ENGINE OMWFC20 RTOPW20 PEM20

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

INSTALLER AND OWNER GUIDE

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

Contact Details. Please note that some of the contact details on this PDF document may not be current.

SP1 Wallfire. SP2 Wallfire. SP3 Wallfire. SP8 Wallfire AUS/NZ. 08/19282/2 (AUS & NZ) Issue 2

(SP4) SP420 (SP5) SP520 (SP9) SP920 AUS/NZ. 08/50019/5 Issue 5

ADL DYNAMIC STORAGE HEATERS INSTALLATION INSTRUCTIONS AND USER GUIDE ADL 2012 ADL 3018 ADL 4024 ADL 5030

Installation Instructions & Operating Manual IMPORTANT

Charlotte CRT20AB, Charlotte CRT20BR & Brookline BKL20

DANVILLE DNV20AB, DNV20BR, DNV20BL & DNV20CH

Technical Specification IRX

Installation and Technical M anual

MOCCA CUBIC AUS/NZ. 08/53066/0 Issue 2

MICATHERMIC PANEL HEATER

Model 801 With Adorn, Icon, Visage, Elegant or Ultimate Fireslide fronts & Model 802 Ultimate, Cosyflame, Fyrside, Nebula & Pizzazz versions

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

INSTALLATION AND USER INSTRUCTION GUIDE. Model (s) Electric Heater Model No s FRER**ME2 / FSER**ME2 / FMER**ME2. ** Denotes case colour / finish

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

OPERATING INSTRUCTIONS

Wall Mount Electric Fire Place with Remote Control

ELECTRIC WALL HANGING FIREPLACE SUITE FUI0005_V2_ USE & CARE MANUAL

AQUA PREMIER ELECTRONIC ELECTRIC SHOWER. Installation and User Guide

INSTALLATION & USER INSTRUCTIONS

instructions OIL FILLED RADIATOR V V and V551225

FW422 Integrated In Column Larder Fridge Manual for Installation, Use and Maintenance

155mm. 820mm. 540mm E D. 940mm. 600mm

USE & CARE MANUAL WALL HANGING FIRE. CO9126 V2_110512

WALL MOUNTED ELECTRIC FIREPLACE (heat blowing from the front series)

USE & CARE MANUAL CONTEMPORARY ELECTRIC FIREPLACE SUITE. CO9144 V3_080714

INSTALLATION & USER INSTRUCTIONS

Sunbeam Remote Controlled Tower Fan

INSTALLATION INSTRUCTIONS

AP24MT, AP24ET, AP15ET, AP10ET. Convection Panel Heaters. Instruction Manual

OAKHURST, AUBERRY OKT20, AUB20

INSTRUCTION MANUAL. Dimplex XLE Series Heater. Installation and Operating. Models: XLE050 / XLE070 / XLE100 XLE125 / XLE150

OPERATING INSTRUCTIONS

Model 804. Chic, Envy, Mirage, Serenity or Twilight fascia.

CERAMIC FAN HEATER URBAN

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

Multipoint. Installation and User Instructions Instantaneous Hand Wash Models: EV 2008

OFC1000, OFC1500, OFC2000, OFC2500 OFC1000TI, OFC1500TI, OFC2000TI & OFC2500TI

INSTALLER AND OWNER GUIDE. Model 807. Electric Heater. Fitted with one of the following fascia

Imperial Electric Fires

ELECTRIC HEATER WITH CARBON FIBER HEATING ELEMENTS

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

INSTRUCTIONS MANUAL INDUSTRIAL WALL FAN (20, 26, 30 ) WITH REMOTE CONTROL

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

USE & CARE MANUAL INSET ELECTRIC FIRE WITH DOWNLIGHTS. CO9145 V1_140812

INSTALLATION & USER INSTRUCTIONS

INSTALLER AND OWNER GUIDE

READ AND SAVE THESE INSTRUCTIONS

BFH range. Features. Base Unit Heater - BFH range

Oil filled Radiators - Models : OFX750/1000/1500 & OFX750TI/1000TI/1500TI

METIS. Installation instructions. Riser rail kit INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER.

Manual and Thermostatic Power Shower Units

The CENTURY. High Performance Oscillating Fan OWNER S GUIDE FOR MODELS 9002X & 9702X

INSTRUCTION MANUAL. Designa DESE Storage Heater. Installation and Operating. Models: DESE050 / DESE070 / DESE100 / DESE125 / DESE150

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

IMPORTANT INSTRUCTIONS READ & SAVE

Sunbeam Remote Controlled Tower Fan

KIT Glamm 3D Plus 500 / 1000

READ AND SAVE THESE INSTRUCTIONS

OPERATING INSTRUCTIONS

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

Lo-Carbon T-series Window & Roof Models

Sunbeam Tower Fan with Night Mode

OPERATING INSTRUCTION MANUAL

MILLI PURE VERTICAL TRIPLE HEATED TOWEL RAIL 900X38 - CHROME

INSTRUCTIONS FOR CARBON INFRARED HEATER

METAL CERAMIC FAN HEATER

INSTANTANEOUS ELECTRIC SHOWER

Dimplex ebrochure PDF

USE & CARE MANUAL COMPACT ELECTRIC FIREPLACE SUITE. CO9158 V1_301012

OPERATING INSTRUCTIONS

Installation Instructions for SHD Series Drawers

MULTIPOINT FF Room Sealed Fan-Assisted Water Heater

Transcription:

TSR Electric Storage Heaters Assembly Instruction Automatic Manual Model Nos: 79341S 79351S 79361S 79344/6S 79354/6S 79364/6S Cat. Nos: TSR12AW TSR18AW TSR24AW TSR12MW TSR18MW TSR24MW This product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014, EN60555-2 and EN60555-3. These cover the essential requirements of EEC Directives 2006/95/EC and 2004/108/EC GDC Group Ltd. All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing. A division of the GDC Group Ltd, Millbrook House, Grange Drive, Hedge End, Southampton SO30 2DF

IMPORTANT PLEASE READ THIS LEAFLET CAREFULLY AND RETAIN FOR FURTHER USE NOTE ALSO THE INFORMATION GIVEN ON THE HEATER The Installation must be carried out by trained personnel. A means for disconnection must be incorporated in the fixed wiring by a double pole switch with a contact separation of a minimum of 3mm and in accordance with the current IEE Wiring Regulations. The heater must not be installed immediately below a fixed socket outlet. The heater is not suitable for connection to a 30A ring circuit. Do not position the heater under windows where curtains can contact the heater casing. To maintain stability, it is essential that the heater is placed on a level surface and care should be taken to avoid irregular surfaces, such as may result from carpets or tiled surrounds partially protruding under the heater. Only heat resisting cable (minimum rating T85) should be used. If used in a bathroom the heater must be installed such that switches and other controls cannot be touched by a person in the bath or shower. During any reassembly of the heater if a part of the thermal insulation shows damage or deterioration which may impair safety, it should be replaced with an identical part. WARNING - In order to avoid overheating, do not cover the surfaces of the heater. Do not put clothes, fabrics or any other materials on the heaters. Do not place objects in contact with the heater. Do not position the heater where objects can come within 250mm (10 ) of the top and 75mm (3 ) of the sides of the heater. CAUTION Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present. This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Children less than 8 years of age should be kept away unless continuously supervised. IMPORTANT - Due to the newness of materials the heater will produce a smell for the first few days of operation. Rooms must be well ventilated and young children, caged birds or people with respiratory complaints must not remain in proximity to the heater for the first 48 hours of the commissioning period.

WALL FIXING: The heater must ALWAYS be mounted against, and fixed to a wall as it will not stand up by itself. A detachable bracket is provided for screwing to the wall, the heater is then placed in position and fixed to the bracket by a screw at each end. The heater must never be unscrewed or moved from the wall bracket whilst it is loaded with bricks. THE HEATER IS VERY HEAVY AND WILL BE DANGEROUS IF ITS WALL FIXING BECOMES INSECURE. Solid Brick and Concrete Walls No. 10 Rawlplug plastic inserts. Drill hole of 8mm dia to a depth of 15mm greater than depth of the insert. Timber Frame Seek specialist advice, some authorities suggest RAWLNUT Panelled Wall, Paramount Board, Chipboard, Plasterboard, etc. Check that the panel itself is adequately fixed to battens etc. Use Rawlplug M5 intersets; drill accurate 10mm dia holes in single skin plasterboard. One fixing should be in studwork. Hollow concrete, Breeze Block and Thermolite Block Walls RAWLPLUG RAWLOK R6054R. Some authorities suggest UNIFIX LB 70/10mm. PLEASE DON T TAKE CHANCES Site conditions may vary considerably and Creda cannot recommend the correct wall fixings to be used. It is the responsibility of the installer to ensure that adequate permanent fixing has been achieved. Purely for guidance the suggested fixings are made for certain wall materials but this list is not comprehensive or authoritative. Different wall constructions will need different inserts. Note that inserts incorporating plastic may be subject to shrinkage behind a warm storage heater and are therefore not recommended. Wall fixings can be obtained from local stockists CARPETS: For safety, the heater must be positioned in the room so that there at least 75mm (3 ) free air space all around it; under windows, ensure that curtains, when drawn, cannot touch or cover the heater casing. In order to maintain stability, it is essential that the heater be placed on a level surface and care should be taken to avoid irregular surfaces, such as may result from carpets or tiled surrounds partially protruding under the heater. The heater feet are designed to go underneath a carpet rather than standing on it; this permits the weight to be taken on a firm base and makes for neatness and ease of cleaning with vacuum cleaners, etc. underneath the heater. Carpet gripper should be removed from behind the heater feet. BRICKS: The heater casing and the heater storage bricks with which it must be fitted, are delivered in separate packages. The brick is common to all heaters, packed in pairs. The brick catalogue number is 791402015. 7934 models have 8 bricks. 7935 models have 12 bricks. 7936 have 16 bricks.

First, turn carton upside down 1 Open bottom flaps on carton Packing corner fitments contain heater feet It is preferable to fit the heater feet whilst the heater is still in its carton. Turn the carton upside down and open the bottom flaps. The corner fitments contain both feet and the fixing kit. The open ends of the feet are to face forward towards the grilles in the panel. After fitting, use the feet to lift the heater from the carton. Cut underlay and remove carpet gripper to clear foot, allowing heater weight to be taken on floor proper; lay carpet over foot, slitting it as shown, it is unnecessary to cut carpet away. 2 Stand the heater against the wall in its intended position. Mark the position of the two outside corners of the wall bracket. Carefully place the heater aside, and remove the wall bracket from the heater by removing the screw at each end. Reposition the bracket against the wall using the corner marks for alignment. Mark through two slots in the bracket, one at each end. Allow mortar courses between bricks to be avoided, or battens, etc. to be found for the fixing holes. If mains connection is to be made from the left hand side, at this point the mains lead must be secured to the back of the heater using ties provided in the fixing kit.

3 When bracket is securely fixed, replace the heater under the bracket angle You and align screw holes on heaters ends. There are two fixing slots at each end of heater, allowing different stand-offs for different thicknesses of skirting board. Do not fully tighten these screws until the bricks are loaded into the heater as some settling of the heater may occur. WALL FIXINGS - VERY IMPORTANT must fit a retaining screw at each end of the heater. NOTE: NEVER REMOVE THESE SCREWS WITHOUT FIRST UNLOADING THE HEATER. See also figure 1 regarding carpets where appropriate. Note: Max. skirting size is 15 x 120mm. Note that the smallest wall spacing should be used only when the skirting board is of the modern slim type, or there is no skirting board at all. THE HEATER MUST STAND VERTICAL 4 A clear space of at least 3 (75mm) must be left at either side of the heater, and any projections or shelves must be at least 10 (250mm) above the heater casing. Curtains must not be draped around or in contact with the casing. A shelf unit is separately available for fitting above heaters. The top panel and front panel are joined and should be removed as one assembly. To do this, remove the screws fixing the rear flange of the top panel, and remove the two screws along the bottom edge of the front panel. Carefully swing out bottom of front panel and lift assembly clear of casing, this operation also removes the control knobs under the flap. Put assembly in a safe place to avoid damage to paint etc. 5

ENSURE THAT CABLE CLAMP IS SECURELY ATTACHED TO THE CHASSIS OF THE HEATER. 6 MAINS TERMINALS IMPORTANT: for earthing, loosen the earth screw sufficiently to wrap the mains earth wire around it between flat washer and cup washer, and retighten the earthing screw. Feed the mains cable through the cable clamp and make connections as marked on the heater. Pull back any slack through the clamp and tighten clamping screw. Make sure clamp is tightening on outer sheath of cable and not on individual conductors. CONNECTING THE MAIN S SUPPLY CABLE Charge Rated Period Charge 79341/4/6S 7 hours 12 kwh 79361/4/6S 79351/4/6S 79341/4/6S 79351/4/6S 7 hours 18 kwh 79361/4/6S 7 hours 24 kwh Some heater variants may have other charge periods or acceptances. See heater rating plate. 7 WARNING Remove the inner front panel; this carries on it s inner face the front insulation slab. Handle this with care, the insulation must not de damaged. REMOVE ALL THE PACKING CARDBOARD FROM INSIDE THE STORAGE BRICK COMPARTMENT, IF LEFT INSIDE IT WILL BE SET ON FIRE WHEN THE HEATER IS SWITCHED ON. ENSURE THAT ALL PACKAGING MATERIAL IS REMOVED FROM THE BRICKS BEFORE FITTING THEM.

8 Temporarily remove one central element to provide access for the rear rank of bricks. Loosen terminals on one of the elements and remove this to allow installation of rear rank of storage bricks. On heaters with 3 or 4 elements remove one of the central ones. 9 Note the way the bricks are positioned in the heater. Otherwise they will not fit. 10 Put in place the rear rank of bricks, pushing them well back against the rear insulation. Replace the element, making sure that the connection is tight. Now, place in position the front rank of bricks, again pushing them back to make room for the front insulation slab which is attached to the front panel. 11

12 Check that the front insulation slab is properly attached to the inner front panel and refit panel (insulation innermost) to the heater by locating its bottom edge behind the front lip of the chassis, and inserting retaining screws along the top and both sides. With the bricks pushed well back, as mentioned earlier, and the insulation properly aligned, there should be no bulging of this panel and no undue force necessary to fix it. Refit the front / top assembly by hooking the rear edge of the top panel over the rear edge of the casing, then swing the front panel carefully down against the casing. Replace the screws along the rear of the top and the base of the front panel which had been removed in Step 5. ENSURE WALL BRACKET SCREWS ARE TIGHTENED FULLY. WARNING. When a new heater is run up to temperature, the materials will produce a smell for the first few days, these are normally harmless in a well ventilated room. It is best to make these first overnight charges with the Charge Controller/Auto-Set knob at Maximum. Caged birds, young children and people with chest ailments are best kept out of the room for this first period. WET BRICKS: If accidentally, the bricks have become wet due to their having been left out-of-doors, some moisture may be driven off during the first overnight charging and this may drip on to the floor. If there is any doubt on this score, advise the customer to lay newspaper beneath the heater to protect carpets etc. REFIT THE CONTROL KNOBS: PLEASE OBSERVE THE FLAT ON THE D SHAPED SPINDLE ALIGNS WITH THE FLAT ON THE KNOB BOSS. SETTING THE CONTROLS 13 The controls are located under the lockable flap at the right hand corner of the top panel. To adjust the controls on the heater use a coin and engage it in the slot provided on the top surface of the knob. AUTOMATIC CHARGING DEVICE (AUTO-SET Fitted only on Sensor Plus) The Auto-Set Control rations the overnight charge each night by sensing the room temperature. The knob is marked with the numbers 1 to 6, turning the knob to a lower number will reduce the charge consequently, the level of room warmth the next day. Once set, the knob should need no further adjustment and the Auto-Set will maintain automatically the room warmth each day by varying the charge according to the weather. 1. Set the room temperature (output) control knob to setting 4. 2. Turn the Auto-Set Knob clockwise as far as it will go. 3. Leave the heater to run in this condition for two nights in order to quickly disperse the new smell which is better removed once and for all. 4. Instruct the user to set the Auto-Set down to his chosen setting on the third day. Instructions on this are given in the Users Guide which we ask you to ensure is left with the user. MANUALLY ADJUSTED HEATER (without Auto-Set Control) On this the user sets the overnight charge on the numbered knob marked Input. Setting up procedure; 1. Turn the lnput knob to maximum setting (6) 2. Set the Output knob to setting No. 4. 3. Leave the heater to run in this condition for two nights in order to quickly disperse the new smell. 4. Instruct the user to set the Input to his chosen setting on the third day. Instructions on this are given in the Users Guide which we ask you to ensure is left with the user. Part No. 84299 Iss. No. 12