Copper convection heaters:

Similar documents
Retrofit an evacuated tube collector to an existing cylinder Updated

Run On Sun Australia Pty Ltd. ABN No P.O Box 34 Deepwater, N.S.W Ph

Soak in the Sunshine. Solar Hot Water

economy environment engineering excellence Advanced Commercial Hot & Warm Water Solutions

Apricus Residential Solar Hot Water Systems CLICK TO START

Catalogue August Heat Exchanger & Solar Components

Go Solar. Go Green. About YogiSun

Panel Radiators. Installation and operating instructions. ThermaRad Classic.

INDIRECT SYSTEM FOR FROST LOCATIONS

Thermosiphon Passive Solar Water Heating

SOLAR WATER HEATING DIRECT SYSTEM FOR FROST-FREE LOCATIONS DOMESTIC SOLAR WATER HEATERS, SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES

SOLAR HOT WATER SOLUTIONS stainless steel roof systems

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

Operation / Installation Manual

Solar water heating system

Installation Instructions

maximise the sun s energy with warmflow solar Warmflow Solar

SOLAR HOT WATER SOLUTIONS stainless steel roof systems

Congratulations with your purchase of our high quality, corrosion-free hot water cylinder (HWC).

RAYPAK HOT WATER & HEATING

ALPHA HEATING & SOLAR NZ LTD (AHS)

Radiators, Towel Warmers and Trench Heating

Roof Mount Solar Hot Water System USER MANUAL

CodeNotes. Solar Water Heating Systems Based on the 2015 International Solar Energy Provisions. Introduction. Solar Water Heating System Designs

ESTEEM EVACUATED TUBE SOLAR HOT WATER

Electric AquaMAX Electric Water Heaters are 15% more efficient than the rest

UNVENTED WATER HEATERS. Water Heater Display Stand

Installation Manual. Conergy TS Open and Closed Systems.

Solar collectors. Speaker

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50-6/16LP50-6, 16NG60-6/16LP60-6, 20NG50-6/20LP50-6, 20NG60-6/20LP60-6, 26NG50-6/26LP50-6, 26NG60-6/26LP60-6

1.1 Controller General Information

Owners Guide and Installation Instructions Rheem HS Series

Apricus Solar Hot Water Systems

CENTRA-COIL QUALITY HOT WATER SERVICE

COMMERCIAL SOLAR SOLUTIONS

Description. Applications

Evacuated Tube Solar Hot Water System. Owners Manual. Version 5.4

Installation Instructions Solar Controller Kit (Part Number AQ )

EC Motor Fan Coil Units. IMD-Y Series l/s

Frequently Asked Questions Solar Collector G24

Whole of Home ADD ON. Add some cool comfort to your life. That s better. That s Actron.

Understanding Solar Types

CodeNotes. Solar Water Heating Systems Based on the 2018 International Solar Energy Provisions (ISEP ) Introduction OFFICIAL

Experienced. Flexible. Reliable. Approachable. Genuine

Owner s Guide and Installation Instructions

SBB 300, 400 S & Sbb 300, 400, 600 Plus

Exceeding the Standard

LOW PRESSURE SYSTEM INSTALLATION GUIDE

3000 Series Fan Forced Ceiling Heater Series Commercial Fan Forced Ceiling Heater

RAYPAK HOT WATER & HEATING

EVACUATED TUBE SOLAR HOT WATER SYSTEMS OWNERS MANUAL JULY 2013 BROCMISC100.1

Installation Instructions

OWNER S MANUAL SOLAR WATER HEATERS

Owner s Guide and Installation Instructions Commercial Storage Tank

comfort BY CONTROL POOL AND SPA HEATING SOLUTIONS

water to water heat pumps

Owners Guide and Installation Instructions

OPERATING INSTRUCTIONS WPSI12. Portable Soldering Station & TCP12. Soldering Tool. Weller Tech Sheet Product Code: Issue A 24/05/05

TERMO Combi Cylinder TECHNICAL INFORMATION

Connect - Contact - Control. Air and water heaters for rail vehicles Ø22. F 195.en

EVERLAST - SERIES 2000

Flamco. Water heaters, storage tanks and accessories DUO WATER HEATER SUPASTOR WATER HEATER LS STORAGE TANKS WATER HEATERS, STORAGE TANKS

Marine Catalog. Marine Catalog. Sure Marine Service, Inc th Ave. N.W. Seattle, WA (800) (206)

Owners Manual Conergy Pty Ltd Split System Open and Closed Systems

Version 1.0. Plumbers Handbook. Scan code for details & installation instructions

For latest prices and delivery to your door visit MyTub Ltd

Installation Instructions

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

VIII. Heaters Mobile Climate Control 121 MCC Reference Manual 2014

Exceeding the Standard

Jr. Tech (JT-1, 2, 3) Knowledge Areas

INSTALLATION MANUAL Roof Mount Solar Hot Water System

Flue Installation Manual

UPRIGHT REFRIGERATORS FOR RV AND MARINE APPLICATIONS INSPIRED BY COMFORT.

SOLAR WATER HEATING SYSTEM VERSOSUN THERMAL SOLUTIONS

INSTALLATION MANUAL Ground Mount Solar Hot Water System

CATALOGUE NUMBERS. Pressure Reducing Valve (PRV)** Mains Supply. Cold Water Outlets

w w a. m o c. x e r fi. w u

Owner s Guide and Installation Instructions

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions

Blow through unit coolers LEX. Standard coolers for cooling & freezing rooms

HOTCO BAND HEATERS FLEXIBLE BAND HEATERS - MICA INSULATED CONSTRUCTION AND LIMITATIONS ELECTRICAL TERMINATION WELDED BAND HEATERS - MICA INSULATED

REFRIGERATORS NEW! CONSISTENTLY COOL, CONSTANTLY THE BEST T1090. The first Thetford Compressor fridge for the Australian market.

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

D O M E S T I C Solar Thermal

P/N CC-100. Coolant Circulator. Operation manual

Owner s Manual Therma-Stor II Heat Recovery System

Innovative, Energy Efficient Water Heating Technology

Quadra. Filtered boiling and chilled drinking water system

HEAT TRANSFER STORAGE CALORIFIERS EC SERIES SC SERIES BT SERIES

SOLAR NOW INTERNATIONAL PTY LTD. Envirosun AS Owner & Installation Manual

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

LEVEL SENSED DRAINS KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP 50 KAPTIV-CS-HP 500 NUFORS-CR MAGY-UL

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Owner s Guide and Installation Instructions

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.

TECHNICAL MANUAL HYPERION. Solar water heaters. Installation, maintenance & use instructions

SOLARMATIC TM. Solar Pool Heating Controller OWNERS MANUAL. Manufactured in Australia By

USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER

Transcription:

Copper convection heaters: Dual pipeline models Dual pipeline QMG models since 2009: The Run On Sun Australia copper convection heaters are manufactured to our own strict quality specifications. A pure copper water tube is incased inside an aluminium heat exchanger, fixed inside a bone-white powder coated steel case. The water runs through high quality 18-mm diameter copper tube, this keeps the water clean without the use of additives. The convection heat output ranges between 1200 watts for the smallest model, through to 1900 watts for the largest model. This is achieved at a water temperature of 64-DegC. Our dual pipeline models have been working in many homes since 2009. Customers say they are pleasantly surprised by the heat output. Four pipeline models Four pipelines, PTD models new for 2014: The new four pipeline models have just arrived, adding double the heat output energy compared to the duel pipeline models. These models have an extra air intake grill on the front towards the bottom of the case, to allow for convection to the upper pipeline heat exchanger. Three models are available with a heat output range between 900-3500 Watts at a water temperature of 64-DegC. Model Size Heat output in Watts Water temp Price L W H 64-DegC QMG600*800*120-mm Dual 800 x 120 x 600mm 1200 $380 QMG600*1000*120-mm Dual 1000 x 120 x 600mm 1500 $465 QMG600*1200*120-mm Dual 1200 x 120 x 600mm 1900 $550 PTD600*420*120-mm Four 420 x 120 x 600mm 900 $295 PTD600*1020*120mm Four 1020 x 120 x 600mm 2400 $560 PTD600*1520*120mm Four 1520 x 120 x 600mm 3500 $650 Polished stainless steel towel heaters: Model-BLH12/360: $310 Height 910-mm. Width 360-mm. Depth 260-mm. Vertical tubes 32-mm diameter, 1.4-mm thick. Horizontal tubes 22-mm diameter, 1.2-mm thick. Model-BXCH-13/500: $330 Height 980-mm. Width 500-mm. Depth 77-mm. Vertical tubes 38-mm diameter, 1.4-mm thick. Horizontal tubes 22-mm diameter, 1.2-mm thick.

1 Stainless steel and nickel coated brass manifold kits for floor heating and convection radiators: Stainless steel manifold kit for floor heating or convection radiators: Hot water inlet manifold. Includes 4 flow control valves, air vent, drain port, a 1 ball valve and 4 pipe joiners which can be removed to expose 1/2 threads. Cool water return manifold. Includes 4 manual check valves, air vent, drain port, a 1 ball valve and 4 pipe joiners which can be removed to expose 1/2 threads. Also includes stainless steel manifold joining brackets. Cost for 4-ports $275 Nickel coated brass Manifold kit for floor heating or convection heaters: Hot water inlet manifold. Includes 4 flow control valves, air vent, drain port, 1 ball valve, temperature gauge and 4 to 9 x circuit joiners. Cool water return manifold. Includes 4 manual check valves, air vent, drain port, a 1 ball valve, temperature gauge and 4 to 9 x 1/2 circuit joiners. Also includes stainless steel manifold joining brackets. Cost for 4-ports $285 Cost for 6-ports $358 Cost for 9-ports $465

Hydronic heating cylinders 14-mm coils are 30-meters long, 19-mm coils are 45-meters long on all cylinders. Squat white powder coated stainless steel cylinder: From $1650. Add $250 per 14-mm coil. Add $350 per 19-mm coil. 340-litre capacity. Low to high pressure bearing capability. 1200-mm high x 700-mm wide. 2-mm thick 316 marine grade stainless steel inner. 0.5-mm powder coated steel outer. 60-mm high-density polyurethane insulation. Choice of zero, one or two inner copper coils. Choice of 14-mm or 19-mm diameter copper coils with 1-mm wall thickness. Customised fittings for various heat sources. Tall white powder coated stainless steel cylinders: From $650. Add $250 per 14-mm coil. Add $350 per 19-mm coil. 100 to 500-litre capacity. Low to high pressure bearing capability. 2-mm thick 316 marine grade stainless steel inner. 0.5-mm powder coated steel outer. 60-mm high-density polyurethane insulation. Choice of zero, one or two inner copper coils. Choice of 14-mm or 19-mm diameter copper coils with 1-mm wall thickness. Customised fittings for various heat sources. 100-litres: 470-mm diameter x 1230-mm high. From $750 200-litres: 540-mm diameter x 1530-mm high. From $990 300-litres: 600-mm diameter x 1880-mm high. From $1350 400-litres: 700-mm diameter x 1540-mm high. From $1750 500-litres: 700-mm diameter x 1880-mm high. From $2050 Highest quality 850-litre capacity all stainless steel: From $2450. Add $250 per 14-mm coil. Add $350 per 19-mm coil. 850-litre capacity. Low to high pressure bearing capability. 2000-mm high x 850-mm diameter. 2.5-mm thick 316 marine grade stainless steel inner. 0.6-mm stainless steel outer. 60-mm high-density polyurethane insulation. Choice of 14-mm or 19-mm diameter copper coils with 1-mm wall thickness. Customised fittings for various heat sources. Big 1000-litre low-pressure stainless steel cylinder. From $1950. Add $250 per 14-mm coil. Add $350 per 19-mm coil. 1000-litre capacity. Low-pressure cylinder. 1700-mm high x 1000-mm diameter. From 0 to 100Kpa pressure bearing cylinder. (100Kpa = 10 meter head) 1.2-mm thick 316 marine grade stainless steel inner. 0.6-mm thick ribbed stainless steel outer. Zero, one or two copper coils available. Choice of 14-mm x 35-meter or 19-mm x 45-meter copper coils with 1-mm wall thickness. Customised fittings for various heat sources.

Examples of two 850-litre tank configurations: Tank Specifications: TYPE-A 850-mm diameter x 2000-mm high. Pressure tank inner, made from 2.5-mm thick 316L stainless steel. Outer made from 0.6-mm stainless steel. Top copper coil to be 40-meters long, 3/4. Bottom copper coil to be 30-meters long 3/4. Coil outlet P/T valve Water to the radiators Coil inlet " BSP thread sensor " Sensor Extra large magnesium anode. Extra large magnesium anode T3 Sensor 1/2 T4 Sensor 1/2 Coil outlet Solar return 2000-mm 3/4 P/T Valve. 1 BSP thread. Return water from radiators T2 Sensor 1/2 Coil inlet Cold inlet Solar flow 3/4 BSP thread for copper coil. BSP thread BSP thread 850-mm Tank Specifications: TYPE-B 850-mm diameter x 2000-mm high. Pressure tank inner, made from 2.5-mm thick 316L stainless steel. Outer made from 0.6-mm stainless steel. Top copper coil to be 30-meters long, 14-mm OD and 12-mm ID. Coil outlet P/T valve Water to the radiators " Sensor " BSP thread sensor Coil inlet Extra large magnesium anode T3 Sensor 2000-mm Extra large magnesium anode. BSP thread for P/T Valve. 1 BSP thread for hot water outlets. " BSP thread for copper coil. Solar return Return water from radiators T2 Sensor Drain Cold inlet Solar flow BSP thread. 850-mm

Run On Sun heat pipe collectors: Includes a choice of: Flat to roof frame. 15-degree pitched frame. 30-degree pitched frame. Six Run On Sun Australia 30-tube collectors in series, total of 180 tubes. All evacuated tube collectors come with a heavy-duty 2-mm thick stainless steel frame and a stainless steel manifold housing. (No dissimilar metals) 58-mm x 1800-mm Tri-tubes with a 15-degree frames for various roof pitches and latitudes. heavy-duty 2-mm thick glass sidewall. (32-mm hail rating) 12-tube collector $820 18-tube collector $1100 24-tube collector $1380 30-tube collector $1620 Special prices for 3 or more collectors. 30-degree frames for various roof pitches and latitudes. We stock 12, 18, 24 and 30 tube heat pipe collectors, the 30-tube collectors are the standard for hydronic heating and are normally connected in series. The quantity needed will depend on your application, generally speaking, allow one tube per 10-litres of water storage. More can be used when a summer heat dump application is used such has thermal mass ground storage, this can dissipate and store the extra heat that is generated in summer for later use in winter. Tubes can also be covered with shade cloth during summer to back them off.

Run On Sun Australia P/L Heat pipe collectors Quality-Certification So many non-certified low cost Chinese brands are showing up in the Australian market with no certification. The copper content and lead content are unknown, these may cost less, but low purity copper is associated with pin-hole corrosion making them false economy. The Run On Sun heat pipe collectors are high quality and are not limited to the Australian standards. The same collectors are rebadged under different brands that have full European, Canadian, US and UK certification. EN-12975-2: 2006 European solar keymark, mandatory for all solar collectors sold throughout Europe. Tested by TUV Rhineland and Certified by DIN CERTICO. SRCC performance testing for the United States. Certified by SRCC. AS/NZS-2712-2007 Design and construction. Certified by Global Mark. AS/NZS-2535-2007 Solar collector performance testing Certified by Global Mark. AS/NZS-4234-1994 Energy savings for Victoria prior to April 2013. Certified by Sustainability Victoria. AS/NZS 4234-2008 Energy savings for Victoria. Mandatory for all solar water heaters and solar collectors sold in Victoria from April 2013. Certified by Sustainability Victoria. AS/NZS-4020 Products in contact with potable water. Certified by Global Mark. AS/NZS 2712-2007 ID No: 100864

Run On Sun Australia Pumps for solar circuits or hydronic heating Grundfos solar-20 low energy hot water circulation pump used for circulating water through a maximum of three 30-tube collectors, or up to 4 convection heaters. Speed 1 = 20 Watts, speed 2 = 25 watts, speed 3 = 30 watts. 2-years warranty $180 2-years warranty $245 12-volt DC hot water pumps for a single heat pipe collector can be used for hydronic heating circuits. TS5 5-watt pump with a 12-month warranty $120. TS5 15-watt pump with a 12-month warranty $140. These pumps can work from a solar panel, regulator and a battery. Pump controllers are available. Large power 3-speed pump. 2 bore with 1.75 unions, used for multiple floor heating circuits. Stainless steel body. Big flow capabilities. Speed-1 = 135 Watts, speed-2 = 190 Watts, speed-3 = 245 Watts. 5-years 5-years warranty warranty $295 $265 Low energy 3-speed hot water circulation pump used to circulate the hot water from the evacuated tube collectors to the cylinder. Can be used on smaller floor heating circuits and convection heater circulation. Tested by Run On Sun to Australian standard AS/NZS4020 Speed-1 = 40 Watts, speed-2 = 60 Watts, Speed-3 = 85 Watts. 5-years warranty. $150 5-years warranty $170 Extra power 3-speed hot water circulation pump used to circulate the hot water through medium sized floor-heating circuits. Tested by Run On Sun to Australian standard AS/NZS4020 Speed-1 = 46 Watts, speed 2 = 80 Watts, speed 3 = 100 Watts. 5-years warranty $165 5-years warranty $180 Pump selection for hydronic heating.

Run On Sun Australia Pty Ltd Web: www.runonsun.com.au E-mail: andrew@runonsun.com.au Phone: (02) 6734 6322 Pump controllers Premium Aestiva: Pre-wired controller for solar circuit pump. Ready to plug in and work. Designed in Australia. Outdoor waterproof rating. $220 SR208C Controller: Controller for solar circuit pump. Not pre-wired. Comes with all sensors. $150 SR868C Controller: Two part controller for solar circuit pump, with one extra sensor that can turn a second pump on at a preset temperature and off at a preset temperature. Not pre-wired. Comes with all sensors. Plug and cord included. $195 SR988C1 Controller: Multi function controller with many features. Ideal for complex hydronic heating circuits. 2 x Pt1000 sensors. 10 x NTC10K sensors. 9 relays for circulation pumps or 3-way magnetic valves. 1 relay for auxiliary heating. $450 ROSA-100 and ROSA-200 PV pump controllers. ROSA-100 Connects to a solar panel for the power source. ROSA-200 Connects to a solar panel and a battery. This controller incorporates freeze protection for the solar collector outside the hours of operation for a solar panel. ROSA-100: 5-watt pump controller with a 5-Watt solar panel $160 ROSA-100: 15-watt pump controller with a 15-Watt solar panel $175 ROSA-200: 5-watt pump controller, 7Ah battery, 10-Watt solar panel $195 ROSA-200: 15-watt pump controller. 7 Ah battery, 20-Watt solar panel $210

Run On Sun Australia supplied the tank, pumps and evacuated tube collectors. A 10-circuit manifold distributor becomes part of the unfinished plant room and connects all of the floor heating circuits for individual control. The pipes leading to the summer heat dump, before the manifold distributors are set up inside the plant room. The fully insulated summer heat dump managed to raise the ground temperature to 70-DegC. The role is reversed in winter, bringing the heat stored in this thermal mass back to the 500-litre cylinder when needed. The plant room showing a Run On Sun 500-litre duel coil tank with pumps, gas booster, house heating circuits and heat dump circuit.

Inside the plant room showing the Run On Sun solar collector pump. Cistern to keep the 500-litre cylinder topped up. Run On Sun large bore pump driving the floor circuits. Run On Sun large bore pump driving the ground thermal mass circuits. Run On sun evacuated tube collectors, the main heat source for the whole project. Finished project.