LINEAR HEAT DETECTION SENSOR CABLE ACCESSORIES

Similar documents
Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

ThermoCable Linear Heat Detection System

IECEx Certificate of Conformity

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

AlarmLine Addressable Linear Heat Detector

Reference Guide 2.1. Certificate Number

ALARMLINE ANALOGUE Linear Heat Detection System

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65

CMA-440 Light Weight Suspended Ceiling Kit

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

UMA-1020 Light Weight Suspended Ceiling Kit

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

new new Industrial plugs and sockets

TENDER NO. PGVCL/PROC/SMC BOX FOR CT OPERATED METER & Junction Box/867


STANDARDS INSTALLATION. Certificate No 077m

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

INTRINSICALLY SAFE LIGHTING RANGE

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

AlarmLine Linear Heat Detector

TECHNICAL SPECIFICATION FOR SMC AMR METER BOXES MADE FROM THERMOSETTING PLASTIC

LINEAR HEAT SENSING DETECTION. System Sensor India 2014

Newson Gale. Cen-Stat Static Grounding clamps, cables and reels. Leading the way in hazardous area static control. IECEx

PASSION FOR POWER. COMPANY PROFILE. More information at made in GERMANY. since 1931

High Performance LSZH Fire Resistant Cable

PERFORMANCE SHOWER PRODUCTS

Controlling Static Electricity in Industry

Camera Housing Washer Units 5 and 25 Litre

HEAVY DUTY BRASS SHOWER PUMPS

HIBC/B INTERMEDIATE BULK CONTAINER HEATER

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

POWER SHOWERS Models 4500M 5002M 4500T 5002T

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

ILED Aquarius CIRCLE-H Mk 2 Helideck Lighting System

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Introduction.

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

Compact Module. Category 6A FTP Cabling System 1.1

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Z-DENS Z-FLEX. Polypropylene Vent Systems for High Efficiency Condensing Appliances. Single Wall Rigid Flexible Liner Concentric

TUNNELS BOXES AND CONNECTORS

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

LIGHTING TEF 9980 STATUS LIGHT, MAIN LIGHT & REPEATER LIGHT ZONE 1, ZONE 2 & SAFE AREA USER MANUAL

Brownell Transformer Breathers

INSTRUCTION MANUAL (ATEX / IECEx)

FIRE AND SAFETY. Manual Call Points p15-1 Magnetic Door Holders p15-3 Detection Cables p15-4 Portable Signals p15-7 Solar Powered Signals p

SURE HEAT MANUFACTURING

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

SCS311 / SCS317 Installation Instructions

DNVGL-CP-0401 Edition February 2016

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation

MICROpeL 75 Combustible Gas Sensor Part Number: PM

S1L Series: Metal Bottom

SERIES: A REVISION ECN# DESCRIPTION OF CHANGE MOD. BY DATE 3 N/A DRAIN HOSE UPDATED 31/08/2016. Drawing Ref. No. Kit No. Part Description Qty

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Riva Studio Dedicated Sealed External Air Kit

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

COMPONENT SOLUTIONS for the lighting industry

Orbis Battery Scrubber OBS38130

Electrical Installations Design, Selection, Erection and Inspection

Xgard. Fixed detectors For flammable, toxic or oxygen gases

fire resistant cables

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

Installation Instructions for Honeywell ALL-SPEC Air Sampling Smoke Detection System

Operating Instructions

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

Total Fire Solutions. Includes BS 8519 and the updated BS :

DNVGL-CP-0399 Edition March 2016

DF1151-Ex Infrared flame detector

Alarmline Linear Heat Detection

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Linear Heat Detection

Overmoulded Cable Assembly Selector Guide

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

10.A4 Modified atmosphere packaging machines

TUNNELS BOXES AND CONNECTORS

MACHINE SHOP ACCESSORIES CLEVER, TIME-SAVING PRODUCTS TO MAKE YOUR LIFE EASIER

ENERGY PRODUCTS DIVISION. Polymeric Surge Arresters Reliable protection for power equipment upto 800kV

- CONSTRUCTION FIRE SAFETY STANDARDS

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Type approval qualification of Photovoltaic Modules Procedures and test experiences

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

HART XL High Sensitivity Smoke Detection

flexible conduit solutions for rail THE POWER IN CABLE MANAGEMENT

Installation and Wiring Instructions

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance


SECTION AIR DUCT ACCESSORIES

Certificate of Compliance

14300 MAINS SEPARATOR ALARM MANUAL

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Sovereign Double CC/DD

Transcription:

Tel: +44 (0) 8452 602 702 Fax: +44 (0) 8452 602 902 Email: proline@linedetect.com Web: www.lineardetection.com UK OFFICE: 1 Wheatsheaf Close, Ottershaw, Surrey. KT16 0JA. United Kingdom LINEAR HEAT DETECTION SENSOR CABLE ACCESSORIES 1. LINEAR HEAT SENSOR CABLE FIXING DEVICES Continuous Uninterrupted operation of a TH digital linear heat detection system, is reliant upon correct sensor cable positioning and regular fixing/support at 1metre intervals using manufacturer supplied or approved clips. This spacing will help prevent sensor cable sag and minimize the risk of mechanical damage. System Operating Sensitivity can be adversely affected where long lengths of an installed sensor cable are in contact with heat absorbent surfaces.the exception being where a surface temperatures is to be monitored by the sensor cable to protect against overheat conditions. Inadequate sensor cable support and/or incorrect installation positioning in relation to the identified risk can lead to a reduction in protection or even a total loss of detection capability. PROLINE PROTECTION SYSTEMS LTD have carefully designed or sourced a range of suitable installation fixings. Primary considerations are flexibility of application, quality and cost. For non metallic fixing devices Low smoke zero halogen materials have been used in manufacture where possible. The following fixings range provide firm support (without damage to the sensor cables), cover a broad range of applications, and consider the importance associated with correct sensor cable location. NOTES: 1.Unless otherwise specified, supply of fixing devices DO NOT include for any nylon bush or cable tie which may have been included in an illustration to indicate how the heat sensor cable should be used with that particular fixing device. 2.Care must be taken when specifying or using any clips which rely exclusively upon a self adhesive base for permanent fixing as they rely upon clean smooth surfaces in order to achieve good bonding. Ordering Information A minimum order quantity is applicable for the illustrated ranges of clips contact the office for details. Where a purchase order is for clips / fixings only, a minimum 100:00 pounds sterling invoice value applies. 1A: Thermal Spacer TS50 One of the most versatile and installation cost saving fixing devices available. It utilizes a unique labour saving twist lock installation principle. The multi application clip is suitable for use on cable trays, dexion racking, concrete walls or roofs. Utilising its 6mm (0.inch) diameter base located screw and washer fixing or 35x17x17mms (1.4x0.66x0.66inch) moulded standoff. An angled cut out on the side of the clip body allows for ease of sensor cable fixing whilst maintaining flexibility of lateral movement/ location adjustment of sensor between clips. Rapid removal of sensor cable during local risk maintenance/repair programmes (if necessary) is achieved without having to remove the fixing. Manufactured from LSF material, the fixing is available with a 50mm body length. Shipping weight: 2kgs/100qty

1B: T Clip PR002 The T clip design provides the required clear airflow around the sensor cable for maximum efficiency. The design also allows for rapid temporary removal of the TH sensor cable as may be called for by the end user for certain routine maintenance /repairs/replacement work within the area in which the sensor cable is installed. Without the necessity of having to also remove the clips. Materials used in the manufacture of the clip are low smoke zero halogen. Not to scale Specification Material: Black Nylon 6 Flammability: Conforms to UL94 Melt Temperature: 220C Specific Gravity: 1.18 Moisture Absorption: 1% Weight (per 1000units): 2.5kgs All dimensions in mms 1C: SPN-3 sensor clamp A versatile sensor fixing for use on multiple Industrial and commercial applications.a steel body ( zinc electroplated for corrosion resistance ) offers a firm mounting of sensor cables via screw fixing, with a santoprene cushion providing electrical insulation, vibration absorption and anti-chafing of the heat sensor cable.

1D: L Bracket Manufactured from stainless steel, the L bracket provides the perfect support for heat sensor cables above the top tier of cable trays or secondary seal on floating roof storage tanks. The multiple height adjustment facility provided by the drilled holes in the longest section of the bracket, assists in selection of the correct height and positioning of the sensor cable above the roof seal. 1E: V Clip Simple but effective design for rapid installation on site. Typical risk applications are cable trays, where the spring steel construction of the clip allows fixing within holes in the traywork. Sensor cable passes through the base of the V with cable tie fixing between the cable and clip providing any necessary tensioning. 1F: Beam Clamp: MCCT-5.5 This provides firm yet flexible support for heat sensor cables for a diverse range of applications and installations. The flexibility being achieved by selection of the most appropriate tie or sub clip assembly to meet the risk requirements.

1G: Edge Clip: BCCT50-5.5R This offers firm support of heat sensor cables, and ensures a clear airflow is present between the sensor and the structure to which it is being fixed. Thereby ensuring any heat sink effect from the structure does not reduce the linear detection system sensitivity. A range of clips to accommodate structure thickness of between 3 mm and 20 mm is available. Please specify when ordering. 1H: Turnbuckle ( ref: STT) / Eyebolt ( ref: STE) + Tensioning Wire ( ref MW ) There are certain applications typically bulk warehouse protection where regular fixing points for the linear heat sensor cable is not practical or possible. In such cases, the use of the Proline TH sensor cable with support wire (supplied on separate reel for on site installation around the sensor cable at a recommended 3 turns per metre) is recommended. The support wire is a flexible nylon covered stainless steel construction 1.05mm diameter with strength 90kgs. The Turnbuckle/eyebolt fixings (supplied complete with nut and washer) will provide the required degree of tension on the sensor cable via the support wire. The maximum length between turnbuckles/ eyebolts without intermediate support/s should not exceed 75metres. It is also recommended that intermediate supports be provided at maximum 15m intervals to eliminate excessive sag in the sensor cable when turnbuckles and eyebolts are used at the 75m maximum spacing. STE- Eyebolt STT-Eyebolt &Tensioner MW- Tensioning Wire 2. JUNCTION/TERMINATION BOXES On site installation of PROLINE digital linear heat sensor cables will involve at least one of the following wiring connections: A) Sensor cable to Sensor cable: For i) Existing installation length extensions, ii) Sectional replacements/repairs iii) To achieve multiple alarm temperatures on a single zone by jointing cables with different alarm temperature ratings. B) Sensor cable to short term fire-proof interconnecting cabling - Where interface units are installed remote from the risk area C) Remote end termination of sensor cable - Unit supplied complete with end of line resistor for open circuit fault condition monitoring. The most reliable and most commonly end user specified method for sensor cable jointing remains Junction/Termination boxes.proline has researched a number of manufacturers of such boxes, and offers the following range of units based upon quality and price. Full Descriptions and photographs - next page.

2A: Heavy Duty Industrial Units Photographs below are not to scale; gland image enlarged for increased detail The unique design of the type COM308 junction / termination box provides for maximum internal working space. Approximately 10% more than more conventional shaped devices. The unit is manufactured from polypropylene, reinforced glass fibre:sealing thermoplastic elastomere. The COM308 is flame retardant, halogen free and is highly resistant to animal and vegetable fats, mineral oil, deisel, weak acids, strong and weak alkaline solutions and alcohol. Dimensions: 85 x 85 x 51 mms Temperature range: -30C to +100C continuous Voltage:400 v rating Rating: IP66 classification to EN 60 529. Flame Protection: glow wire test 750C to EN 60695-2-11 Cable entry: Compression glands or use of 8 elastic self sealing membranes Fixing: Mounting clip for snap on fixing or 4 internal openings outside of sealing area. Cover: 4 captive quick release screws. Terminal/poles: 4mm2. Colour; RAL 7035 light Grey (also available in black, white and grey box/red cover) COM 308 Glands Reducers (TH sensor cable entries only) 2B: EExe Hazardous Area Unit The type COM Eexe100301 In line jointing and end of line termination boxes are manufactured from impact corrosion and UV resistant glass re-inforced polyester compound. High temperature resistant and anti-static properties Screw on lid allows ease of installation locked with specialkey to prevent unauthorised tampering. No exposed metal parts. No drilling or tapping of entries required. Supplied c/w M20 glands Dimensions: 90x 89 x 58 mms (3.6 x 3.6 x 2.3 inches Internal Mounting: Approved EExe Terminals IP rating: IP68 Combustion Behaviour: VO-self-extinguishing UL94 Cable Glands: Approved EExe glands Colour: Black Hazardous Area Classification: CENELEC/ATEX Category 2, Category3, EexeII 2GD Compliance Code EN50014:1997, EN50019:2000 EN50281-1-1 1999 Impact Protection Ingress protection Operating Temperature Fire Rating (red boxes) Certification No. DEMKO 01 ATEX 130324 (Apparatus), 130515U ( Unfinished) DEMKO 01 ATEX 130324 (Apparatus), 130515U (Unfinished) 14 joules IP66/67/68-30C to + 130C 750C for 30 minutes The information provided on this data sheet is accurate at time of going to print. In the interests of improving quality and design, PROLINE PROTECTION SYSTEMS LIMITED reserve the right to amend specifications without prior notice. Edited version.07.06 Registered Office KingsWorthy House, Court Road, KingsWorthy, Winchester, Hampshire. SO 23 7QA U. K. Registered in England Number 4421495 V.A.T. Registration Number GB 799 9244 45