TA-Compact-P. Giving you MORE by giving you LESS

Similar documents
SAUTER Valveco compact. A pressure-independent multi-function valve

Automatic balancing valves ASV-PV (new generation) DN 32-50

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

HERZ Regulating valve 4002

HERZ Differential Pressure Control Valve 4002

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

INDUSTRIAL AIR CURTAIN. IndAC 2

Thermostatic valves with radiator connection systems

Pressure Independent Control Valves

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Acvatix PICV hydronics made easy. The simple and flexible way to energy-efficient HVAC plants with pressure-independent combi valves

INDUSTRIAL AIR CURTAIN. IndAC 2

HARDEST WORKING BRAND IN THE BUSINESS

1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems.

Thermostatic Radiator Valves (Caleffi)

manifold, for radiators

Pressure Independent Control Valves

Three-way reversing valve

3 years payback time. Millions of reasons to choose the best.

20% Drive energy efficiency and increase customer satisfaction. asv.danfoss.com. ASV automatic balancing valves

Zeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology

Multilux 4-Eclipse-Set

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Standard. thermostatic valve body without presetting

Balancing & Control. Frese OPTIMIZER 6-way. Pressure Independent Control Group

TA-SCOPE. Balancing instrument ENGINEERING ADVANTAGE

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

IMI Heimeier Kit Hydroca ble

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

Ingersoll Rand 5-15 hp. Rotary Screw Compressors

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Smart temperature control solutions

5 (34) 10 (69) 45 (170) 64 (242) 65 (246) 92 (348) 90 (341) 127 (481) 85 (322) (227) 80 (303) 113 (428) 148 (560) 105 (397) 141 (534) 100 (379)

UltraPleat Technology BURAN REFRIGERATION COMPRESSED AIR DRYER

Genesis Series 5,5 to 22 kw. Compressed air at your service

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.

TACOTHERM DUAL PIKO MODULAR AND HIGHLY FLEXIBLE HEAT INTERFACE UNITS

1year. The natural connection between energy savings and a balanced two-pipe system.

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

Refrigerant Dryers DS Series

F Series - Refrigeration dryers

Paddle Flow Switch. Pressure Control Flow Switch

Radiator Valve Program

Automatic Temperature Controller (ATC)

Say heating. Say Herz. HERZ-Supply Engineering

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

thermostatic valve body with stepless precision presetting

Balancing & Control. Frese SIGMA Compact. Dynamic Balancing Valve

Ingersoll Rand. Rotary Screw Air Compressors 5-15 hp (4-11 kw)

TS RD 7761 RD, 7761 RD

Balancing & Control. Frese OPTIMIZER. Pressure Independent 4-pipe Coil Control Unit

Distributed by: 2008 Ingersoll-Rand Company CCN IRITS

Simply safe. Transponder-coded safety switch CET with guard locking

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

Valves, controls + systems Flow, pressure and temperature balancing

BURAN REFRIGERATION COMPRESSED AIR DRYER. UltraPleat Technology

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Thermostatic valve bodies

Temperature controller for steam (PN 25) AVT / VGS - external thread

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

ingersoll rand refrigerated air dryers

Screw Compressors. S Series. Capacities from: 8.8 to 89 cfm Pressures from: 80 to 217 psig.

Hot Water Makers. Efficiency at its Best

TDS Conductivity Probe In-Line conductivity measurement

Frigoscandia Equipment GYRoCOMPACT

ProRadiant Manifolds, Stations and Fittings

OIL-INJECTED ROTARY SCREW COMPRESSORS GX 2-7 EP G 7-15 EL

refrigeration drying solutions

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

ROLLAIR AIR COMPRESSORS

Tankless On Demand Electric Water Heater

TA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water

Balancing & Control. Frese PV Compact. Differential Pressure Control Valve

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

F-H Refrigerated Dryers

Hydronic Mechanical Panels

Electrolux Professional Washer Extractors

Taco 00 Series Cartridge Circulators

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

Model SFMV Series. Lead-Free Supply Fixtures Based On The MV17 Master Mixing Valves

Who we are and what we do. The story of the world s leading manufacturer of axial impellers

VERSO Air Handling Units

Seasonal Efficiency Longevity Part-Load Efficiency Condensing Operation Fast ROI MODULEX BOILERS MLX-1060 MLX-909 MLX-757

The New Caroma TMV20

Indirect Fired Water Heater

3 years payback time. Millions of reasons to choose the best. Energy Demands? Comfort Problems? Maintenance Concerns?

RC350. Glaston Flat Tempering

Refrigerated Dryers. Cycling; Non-Cycling; High Pressure; High Temperature ,000 scfm

Transcription:

TA-Compact-P Giving you MORE by giving you LESS

control valve balancing valve 5 in 1

full measurement TA-Compact-P The new two-way pressure independent balancing and control valve for terminal units in both cooling and heating systems. Guaranteed to deliver precise hydronic balancing and high controlability to meet the desired room temperature for maximum comfort. shut-off differential pressure controller

MORE compact TA-Compact-P with fan-coil It requires minimal space around the valve. Access to measuring points, settings, shut-off and the connection to the actuator can all be found on one side of the valve. Even if two valves are close to each other, you still have easy access to everything you need. LESS space required

MORE diagnostics Despite the valve being very compact, it offers a wide range of diagnostic capabilities. Your benefits: > trouble-free commissioning > pump head optimisation > simple detection of possible system failures With TA-Compact-P, it s easy to understand system behaviour and performance. Accurate measuring allows you to maximize energy efficiency of the system while minimizing energy consumption. Through direct measuring, you can find possible system failures in the installation, such as clogged pipes and filters, opposite flow direction, undersized pumps, air pockets in pipes etc. You can measure: > flow > temperature > pressure drop > power > available differential presure LESS guesswork

MORE flexibility TA-Compact-P offers freedom to be mounted in any position even if coupled with TA actuator thanks to high IP protection class. For standard couplings Other connection possibilities: > female thread (ISO 228) > female thread Rc (ISO 7-1) > female thread NPT (ANSI/ASME B1.20.1-1983) > welding connection > soldering connection > smooth ends > compression connection LESS limitation

MORE longevity More than 50 years experience with our own brass material Ametal, which was patented in 1963, guarantees full functionality, longevity and zero maintenance costs. Ametal is highly resistant to different types of corrosion, for example, dezincification and stress corrosion cracking. made in Sweden You can trust it. Ametal full functionality high resistance to corrosion longevity maintenance-free LESS worry

MORE balance TA-Compact-P has the ability to limit the flow according to its setting. When TA-Compact-P is fully open, it maintains constant flow through the terminal unit and ensures right flow in the entire system. TA-Compact-P simplifies comissioning and hydronic balancing. Total flow throughout the system from 2-way control valves with on-off actuators: Heat output 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 0% 20% 40% 60% 80% 100% Total flow Total flow with standard 2-way valves Total flow with TA-Compact-P For more information please refer to the Energy fact book LESS energy usage

MORE flow TA-Compact-P DN 10 DN 15 DN 20 DN 25 DN 32 qnom [l/h] pv [kpa] min max min* max 21,5 120 15 400 88 470 15 400 210 1150 15 400 410 2210 23 400 800 3700 23 400 TA-Compact-P was designed to achieve high flow with minimal demands on pumps to ensure high energy efficiency and minimal energy usage. Due to its diagnostic features, it is very easy to check flow and properly adjust the working point of the pump. *Valid for position 10, fully open. Other positions will require lower differential pressure. LESS pump consumption

MORE user friendly easy access to all essential information > Clearly visible valve setting, just one turn > Fast identification of insulated valve > The setting can be easily changed by hand, a setting key is not needed > Position X to shut-off valve without protection cap > Factory setting: fully open, position 10 LESS hassle

MORE choice Control & balancing valves for terminal units COMBINED BALANCING & CONTROL VALVES LINEAR EQM TBV-C DN 15-25 TBV-CM DN 15-25 TA-FUSION-C DN 32-150 COMBINED PRESSURE INDEPENDENT BALANCING & CONTROL VALVES TA-Compact-P DN 10-32 TBV-CMP DN 15-25 TA-FUSION-P DN 32-150 With the most complete range of control & balancing valves on the market, we offer you the best solution for optimal functioning of your system at a lower investment cost. LESS investment

Find out more www.ta-compact-p.com