Disabled Persons Toilet Alarm Kit

Similar documents
Disabled Persons Toilet Alarm Kit

Accessible Toilet Alarm

Installation Guide. Disabled Persons Emergency Alarm Kit. Single Zone Call Control/Call answered unit c/w Sounder LED indicators and Braille lettering

Disabled persons toilet alarm kit from Cameo Systems

conventional call system

Emergency Assist Alarm Kit Single Zone

800 SERIES. call system

Quantec NURSE CALL. Nurse call system & dementia care from Channel Safety Systems

Installation & Operating Instructions

Door Release Power Supply

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

NURSECALL 800E MK3 SYSTEM INSTRUCTIONS BASIC WIRING

EMERGENCY ASSISTANCE ALARMS

DISABLED TOILET / EMERGENCY ASSISTANCE ALARMS

800 SERIES. call system

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

ELECTRONIC SOUNDER STROBE Model : AVD-C407

installation & maintenance manual LPCB APPROVED CFP 2/4/8 ZONE FIRE ALARM CONTROL PANEL approved document no. DFU rev 5

LEAKSTOPPER RANGE Multizone water leak detection systems

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

New Silent Alert Fire Safe System

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

LEAKSTOPPER 1 Single zone water leak detection system

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

Fire detection and alarm

Installation, Operating and Maintenance Manual

SECURIT 700L PLUS ENGINEERING MANUAL

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

Control Panel User Guide

Intelligent Security & Fire Ltd

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

System 800 Addressable Fire Detection & Alarm System

USER MANUAL & MAINTENANCE GUIDE OG OO

USER MANUAL CEF AP28 CONTROL PANEL

WARNING FIRE DOOR CLOSING

Intercall 600 & Intercall 700 Installation & Operation Guide Documentation Issue 4.25

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Intercall 600 and Intercall 700 Installation & Operation Guide Documentation Issue 4.3

The EN54 Part 2 and 4 Fire System

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Excel-EN Conventional Fire Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

INSTALLATION MANUAL SECURIT 802 CONTROL PANEL

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Advantage 6 Alarm Panel

Emergency Voice Communication System (EVCS) Consu ltant s Specific atio n CONTENTS

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

FIRE ALARM CONTROL PANEL FVC01-08

SMARTWALK DEMENTIA WANDERING SYSTEM

User Guide. HTM Nurse Call. In the event of requiring assistance, please contact your Installer/Supplier.

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

Intruder - Fire - Water Combined Alarm

OPERATION AND INSTALLATION MANUAL

XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL. user manual and log book. approved document no. DFU Rev 1

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Strikemaster ES Engineering Manual

Unity DAU Voice Alarm System

ZFP Networkable Analogue Addressable Fire Alarm Control Panel

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

Deaf & Hearing Impaired RadioLINK Alarm System

Confidence. specify with. Applications Nursecall Dementia Care Staff Protection Emergency Assistance Cell Call Affray

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

Smoke Vent Control Panel PCB4 V4 Installation Manual

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Features, Operation & Devices

NURSE CALL SYSTEM SPECIFICATION

NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK.

Silent Alert Fire Safe System

user manual and log book XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

AP10LED 10 Zone onboard LED Alarm Panel. Engineering Manual

Conventional Fire Alarm System 2014 V1.2

EP203. Manual. Approved Document No. DFU Rev 2

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

DOMESTIC STEAM GENERATOR Installation Instructions

Flopurge TS. Operation Manual

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Application, Installation, Operation & Maintenance Manual

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

Intelligent Security & Fire Ltd

Installation and user manual for the BiWire / Conventional Repeater Panel

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Control Panel Engineering and Commissioning Instructions

CW9000 Wireless Fire System. Installation Manual

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

Transcription:

NC951 DESIGN & INSTALLATION GUIDE Disabled Persons Toilet Alarm Kit Quick start installation guide...............................2 About this document............................................3 Important notes................................................3 NC951 kit contents..............................................4 Designing a disabled persons toilet alarm system....................5 Installing the system (mains & extra low voltage wiring)...............6 Engineer selectable functions....................................7/8 Basic operation.................................................9 Expanding the system (including optional Strip-Switch connection).....10 Other 800 Series applications.....................................11 Technical specifications..........................................12 Single Zone Emergency Assistance Alarm Approved Document No: DNU0951001 Rev 2 Page 1 of 12

Approved Document No: DNU0951001 Rev 2 Page 2 of 12

ABOUT THIS DOCUMENT This document provides a brief overview of disabled persons toilet alarm system design and installation, based on the recommendations of BS8300 (the code of practice for the design of buildings and their approaches to meet the needs of disabled people). For further information, please refer to the full version of BS8300, copies of which are available at your local reference library or can be purchased from the BSI (British Standards Institute; Tel. +44 (0)20 8996 9000; Web: www.bsi-global.com). Other National standards of design and installation should be referenced and adhered to where applicable. This document must not be left accessible to the user. A separate user guide (document no. DNU9510000) is available for this purpose. No responsibility can be accepted by the manufacturer or distributors of this equipment for any misinterpretation of an instruction or guidance note or for the compliance of the system as a whole. IMPORTANT NOTES This equipment must be installed and maintained by a suitably skilled and technically competent person. The One Zone Call Controller included in this kit is a piece of Class 2! equipment. H o w e v e r, any metal parts used during installation (i.e. metal back box) M U S T be earthed. The earth termination point on the One Zone Call Controller is provided for installer convenience only and, as such, should only be used if an earth connection is not re q u i red elsewhere. This product has been manufactured in conformance with the requirements of all applicable EU Council Directives. Approved Document No: DNU0951001 Rev 2 Page 3 of 12

NC951 KIT CONTENTS This kit includes everything you need to create a high quality BS8300 clause compliant emergency assistance alarm, except cables and fixings. The following items are included in the kit box:- NC809DBB Remote Reset Point c/w Sounder Includes a Braille label, re s e t button, red reassurance LED and on-board sounder. NC807C Ceiling Pull Includes a red reassurance LED, three metres of red pull cord and two triangular pull bangles. A c c e s s o ry pack Containing six device mounting screws and two shorting links. NC949 Disabled WC Sticker A gloss finished, p e rmanent vinyl sticker featuring the universally re c o g n i s a b l e Disabled WC symbol. NC942B One Zone Call Contro l l e r Includes an on-board 12V 140mA PSU, a 500mA re c h a rgeable backup battery, Braille label, alarm LED, power on LED, volume adjustable sounder, volt-fre e relay output and a link selectable reset/mute button. NC806CS Overdoor Light c/w Sounder Now supplied as a single gang moulded unit (pictured right) o ffering improved visibility, reduced installation times and less likelihood of vandalism D o c u m e n t a t i o n Including a Design and Installation Guide (this document) and a User G u i d e. If installing our NC951STRIP kit, in addition to the above items, a 1.5m length of strip-switch and an NC889 call latch module are also included. Note that specific instructions on how to connect these two additional items to the system can be found on page 10 (Expanding the system). Approved Document No: DNU0951001 Rev 2 Page 4 of 12

DESIGNING A SYSTEM The diagram below shows a typical layout for a good practice disabled persons toilet alarm system based on the recommendations of BS8300. It should be noted that the exact position of the devices shown can be varied to suit a particular application provided that the recommendations described are met. Other/alternative standards of design and installation should be adhered to where pertinent. Figure 2 : A Typical BS8300 Clause Compliant Emergency Assistance Alarm Locate the Ceiling Pull so its pull cord can be operated from the WC and an adjacent floor area. If you are installing the system into an en-suite bathroom, site it so it can be operated from all thre e a reas - the bath, the WC and the floor. If this is not possible use an additional Ceiling Pull, see Expanding the System, page 10. Site the Overdoor Light c/w Sounder so it audibly and visually guides people to the a rea assistance is re q u i re d 4 core security cable Set the upper triangle between 800mm & 1000mm above the floor (knot c o rd at re q u i re d h e i g h t ) 1 m m 2 T & E 2 3 0 Vac fro m 3A switch fused spur Site the One Zone Call Contro l l e r at any convenient point on the installation (typically alongside a reception desk or other staff e d a rea) to provide additional alarm i n d i c a t i o n Set the lower triangle exactly 100mm above floor level (knot and trim off any excess cord ) Position the Remote Reset Point c/w Sounder so it is reachable fro m both the WC and a wheelchair. BS8300 says reset switches for a l a rm calls should be mounted between 750mm and 1200mnm f rom the floor and at least 350mm away from any corn e r s Up to three additional 800 Series devices (ceiling pulls, overdoor lights, reset points, etc., can be connected to the system if re q u i red - see pages 10 & 11 for details). Note that the call cont roller also features an onboard volt-free relay which can be optionally interfaced to extern a l l y p o w e red beacons, strobes or other ancillary devices (again, see page 10 for details). All system components should be sited internally in areas where they are readily accessible by the person(s) designated to use them. Areas should be clean and dry and the ambient light and sound levels should allow the status of all device indicators and sounders to be seen and heard. Any likelihood of tampering or vandalism should also be taken into account. Approved Document No: DNU0951001 Rev 2 Page 5 of 12

INSTALLING THE SYSTEM ALWAYS ENSURE THE MAINS SUPPLY IS ISOLATED BEFORE MAKING ANY CONNECTIONS. Figure 3 : Typical NC951 Disabled Persons Toilet Alarm Kit Wiring / 3A Switch fuse spur 1mm 2 T&E One Zone Call Contro l l e r (mounts on a 25mm UK double gang back box) O v e rdoor Light c/w Sounder (mounts on a 25mm UK single gang back box) Remote Reset Point c/w Sounder (mounts on a 25mm UK single gang back box) Ceiling pull ( S u rface mounting) Base fits 16mm conduit and BESA centre s Mains wiring The general requirement for the mains supply to the call controller is fixed wiring, using three core cable of not less than 1mm 2. This should be fed from an isolating switched fused spur, fused at 3A, which is marked appropriately a n d s e c u re from unauthorised operation. Live and neutral should be connected to the CONN2 controller s L and N L terminals respectively. If a plastic back box is N used, make the earth connection to the terminal marked at connector block CONN2. If a metal back box is used, the earth connection must be made to the earth bonding point on the back box. All external wiring brought into the unit must be adequately insulated with PVC or Neoprene. All mains wiring should be provided in accordance with the current edition of the IEE Wiring Regs (BS 7671) or in accordance with the relevant national wiring rules. Extra low voltage (ELV) wiring All low voltage wiring must be carefully planned before starting the job. Always segregate low voltage wiring from the mains wiring. Three cores of four core stranded burglar alarm cable is ideal for most installations with all components requiring a positive, negative and signal connection (except the ceiling pull which DOES NOT require a positive connection).! IMPORTANT: Connecting positive to the ceiling pull s signal (Sig) terminal WILL permanently damage the device. Note that the running order of the overdoor light, ceiling pull and reset point can be changed to suit a specific application and/or to reduce wiring runs. All wall-mounting devices should be mounted onto a back box of the re q u i red depth. Assess the condition and construction of all mounting surfaces prior to installation and use a suitable screw fixing arr a n g e m e n t. Note that the ceiling pull is surface mountable. I m p o rtant: In the event of a short circuit on the low voltage wiring, an internal self-resetting fuse will temporarily isolate the system until the fault is cleared. The Call Contro l l e r is also protected by a non-serviceable thermal fuse in its t r a n s f o rmer winding which will blow if there is a serious malfunction. If this happens, re t u rn the controller for re p a i r. Approved Document No: DNU0951001 Rev 2 Page 6 of 12

ENGINEER SELECTABLE FUNCTIONS The NC942B One Zone Call Controller has a number of engineer selectable functions. This section of the manual explains how these functions work and how to implement them. Figure 4 : Rear view of the NC942B One Zone Call Controller Reset Mute Volume PLK1 L CONN2 RECHARGEABLE BATTERY BACKUP SUPPLY COVER V R1 N RLY1 NC942B MODEL ONLY Fit to Enable PLK 2 battery CONN3 Reset button operation (Link PLK1) Link PLK1 allows the call controller s on-board RESET button to be set up to:- (a) Reset the system In this position, pressing the contro l l e r s RESET button when an alarm signal is active will re t u rn the entire system to its normal state. (b) Mute the system In this position, pressing the contro l l e r s RESET button when an alarm signal is active will mute the contro l l e r s on-board sounder. All other sounders and reassurance LEDs will remain active until the Remote Reset Point s RESET button is pressed inside the WC. Res et Res et Mute Mute (c) Have no effect In this position (no link fitted), pressing the contro l l e r s RESET button when an a l a rm signal is active will have no eff e c t. WARNING: Many authorities insist that the reset function of a call system be carried out at point of source (i.e. in the room in which the call was made) to ensure that the! person who raised the alarm is visited. There f o re, unless there is a definite re q u i re m e n t to the contrary, we recommended you choose option (c) above. If in doubt, speak to the building manager for advice. Note that the default setting for Link PLK1 is link not fitted/no effect and that the shorting link is provided in the kit s accessory pack. Volume control (Potentiometer VR1) Potentiometer VR1 can be used to adjust the level of the call controller s on-board sounder. The default setting for the volume control is its mid-setting. Turning the control Volume clockwise with a terminal screwdriver will increase the volume, turning it anticlockwise will decrease it. The actual level required will normally depend upon the ambient noise levels within the building and personal preference. Reset (no link fit ted) Mut e Approved Document No: DNU0951001 Rev 2 Page 7 of 12

On-board volt-free relay operation (RLY1) The call controller includes an on-board volt-free relay with normally open (NO), normally closed (NC) and common (C) contacts. The relay contacts are rated at 30Vd.c. @ 1A and can be used to switch optional externally powere d devices such as sounders, strobes or the extra low voltage coils of mains cont rolling relays. When no calls are on the system, the normally closed contact is made. When an alarm signal is present, the relay switches and the normally open contact is made. Muting the system will have no effect on the relay s operation. See EXPANDING THE SYSTEM, page 9, for typical wiring schematics. Battery backup enable/disable (Link PLK2) Link PLK2 enables or disables the call controller s 500mAHr rechargeable battery backup facility. When enabled (link PLK2 fitted), the NC942B s onboard battery backup supply will continue to power the system for approximately 24 hours (standby) plus 15 minutes (alarm running time) in the event of a mains failure. This will be indicated by the controller s ON LED flashing green approximately once per second. Should the mains supply remain disconnected for a prolonged period of time, the battery backup facility will automatically shutdown to prevent the batteries from deep discharge. Note that the default setting for Link PLK2 is link not fitted/battery disabled. This is to conserve battery life and ensure the safety of the controller during storage/transit. Note that the shorting link re q u i red to enable the facility is provided in the kit s accessory pack. Optional emergency/distress call level (Extra equipment required) If required, the call controller can be used to generate an additional, more urgent level of call using separately available components from our 800 Series Call System range. Compatible devices include the NC804DE emergency call point and the NC802DEWM water resistant alert point (see pages 9 & 10 for details). These devices are typically used to allow the person attending to the call to request additional assistance should the person who raised the alarm be in distress. When an emergency/distress call is triggered, an active or muted standard alarm call will be overridden. The controller s CALLING LED will flash red and its on-board sounder (and relay) will pulse intermittently. The overdoor light c/w sounder outside the WC will also pulse to indicate that more urgent assistance is required. Up to three additional calling devices can be connected to an NC942B call controller. Should you wish to connect more, consider using an NC941 call controller which is specifically designed for powering larger single zone call systems. Information on how to connect additional devices to the system can be found on page 9. Sounder and LED test facility CONN3 P LK 2 Pressing the controller s RESET button when link PLK1 is fitted in the Reset (a) position will cause all of the system s sounders and LEDs (apart from the ceiling pull s LED) to activate. When the button is released, the LEDs and sounders will switch off. The same test can be carried out by pressing the Remote Reset Point s RESET button. Fit to E nable battery Approved Document No: DNU0951001 Rev 2 Page 8 of 12

B A S I C O P E R AT I O N Once the system has been installed, check that it works correctly with re f e rence to the diagrams below. Raising an alarm The distressed person raises an alarm by pulling the cord of the ceiling pull unit The ceiling pull s red reassurance LED illuminates to reassure the user that an alarm has been made Additional feedback that an alarm has been raised is provided inside the WC via the Remote Reset Point s sounder and reassurance LED Outside the WC, the overdoor light c/w sounder activates to visually and audibly guide peopl e to the area where assistance is required The one zone call controller s CALLING LED illuminates and its sounder activates to let staff know that someone is in need of assistanc e Note that the call contro l l e r s onboard relay will also activate when an alarm call is made and any external equipment connected to the contro l l e r s relay contacts will operate as configure d. Resetting the system Alarm calls can be cancelled from inside the WC at any time by pressing the Remote Reset Point s RESET button Depending on how the Call Controller is configured (see page 6), pressing its RESET button will :- (a) cancel the alarm and reset the system ; (b)mute the call controller s sounder; or (c) have no effect. Please read the warning notice on page 6 for important advice on how this function should be set-up. Approved Document No: DNU0951001 Rev 2 Page 9 of 12

EXPANDING THE SYSTEM The diagrams below show how the system can be optionally expanded to suit a particular application. Connecting additional 800 Series devices to the system Up to three additional 800 Series devices (any mix) can be connected to the system as shown below. Should you wish to connect more than three devices, consider using an NC941 call c o n t roller which is specifically designed for use on more heavily populated single zone systems. Devices can be wired to the call controller in any order to suit the application. / 1mm 2 T&E NC942B NC806CS NC809DBB NC807C NC807C NC804DE NC806CS Connecting a non-800 Series device to the system via the contro l l e r s relay output The call controller s volt-free relay contacts are rated at 30Vd.c. @ 1A and can be used to switch optional e x t e rnally powered devices such as sounders, stro b e s or the extra low voltage coils of mains contro l l i n g relays. A typical wiring schematic appears right. When an alarm signal is present, the relay switches from normally closed to normally open. / 1mm 2 T&E NC942B Connecting a length of BF358 strip-switch to the system The diagram below shows how to interface a length of strip-switch to the system using an NC889 call latch module. (Our new NC951STRIP kit includes a 1.5m length of strip-switch and a call latch module - note that longer lengths of strip-switch and corner pieces can be purchased from your distributor). / 1mm 2 T&E NC942B Strip-Switch NC806CS NC889 Call Latch Module NC809DBB Wi re link must be cut for n o rmally open trigger NC807C Refer to the i n s t ru c t i o n s supplied with the strip-switch for mounting details. Approved Document No: DNU0951001 Rev 2 Page 10 of 12

OTHER 800 SERIES APPLICATIONS 800 Series Call Systems can be used for literally hundreds of applications ranging from simple one zone installations in disabled persons toilets to multi-zone systems in nursing homes, hotels, shops, council offices and GP surgeries. In addition to the items included in this kit, a wide range of additional components are available including multi-zone indicator panels, wall-mounting call points (in plastic and stainless steel), water resistant alert points, infrared ceiling receivers, monitoring points and remote sounders. The diagram below shows a small selection of the devices available - please contact your distributor for further details. LEISURE CENTRES & POOLS MEETING & CONFERENCE ROOMS NC802DEWS SLAVE WATER RESISTANT ALERT POINT NC803M MAGNETIC NC802DEWM RESET KEY MASTER WATER RESISTANT ALERT POINT CHANGING ROOMS NC806C OVERDOOR LIGHT NC802DB BUTTON RESET CALL POINT INFRARED PANIC ATTACK SYSTEMS NC806CS/SS STAINLESS STEEL OVERDOOR LIGHT C/WSOUNDER NC802DEM/SS STAINLESS STEEL CALLPOINT SWITCH FUSE SPUR NC803M MAGNETIC RESET KEY NC930 12V250mA PSU NURSING HOMES & HOSPITALS NC807C CEILING PULL 1mm 2 T&E NC802DEB-1/2 BUTTON RESET EMERGENCY CALLPOINT NC899IRR KEYSWITCH RESET POINT NC944 FOUR ZONE CALLCONTROLLER NC944 FOUR ZONE CALLCONTROLLER NC302RXC MASTER INFRARED CEILING RECEIVER QT412RXA INFRARED TRANSMITTER (PUSH/PULLFOR EMERGENCY) For 12 zone systems, use three four zone call controllers connected to one NC925B1 1 2V 1A white boxed PSU. For larger system s (up to 90 zones in size ), use our K or KE ra nge of indicator pa nels. DOOR MONITORING SYSTEMS NC302RXCS SLAVE INFRARED CEILING RECEIVER NC894DKM ISOLATABLE MAGNETIC RESET MONITORING POINT NC806CS OVERDOOR LIGHT C/WSOUNDER NC805C/6 6FT(1.8M) TAILCALL LEAD TO OTHER ZONES NC806CS OVERDOOR LIGHT C/WSOUNDER DOOR CONTACTS NC803M MAGNETIC RESET KEY = Four core security cable Approved Document No: DNU0951001 Rev 2 Page 11 of 12

TECHNICAL SPECIFICATIONS NC942B One Zone Call Controller with battery backup facility Mains supply: Voltage: 230V a.c.; Max current: 23mA; Frequency: 50Hz. Output: Voltage: 12V d.c.; Current: 140mA; Volt-free relay contacts (NO/C/NC). Indicators: Red alarm present LED; Green supply present LED (flashes green when battery back up is active in the event of mains failure). Controls: RESET Button (link selectable for reset, mute or no function). IP Rating: IP41 when correctly installed. Dimensions: 147 x 87 x 39mm (WxHxD). Mounts on 25mm UK double gang back box. NC807C Ceiling Pull Input: Voltage: 12V d.c.; Connections: Signal and -Ve. Pull cord: Generates an alarm call when activated. Indicators: Red reassurance LED active in alarm. IP Rating: IP41 when correctly installed. Dimensions: 93mm diameter x 27mm deep. Surface mountable. NC806CS Overdoor light c/w sounder Input: Voltage: 12V d.c.; Connections: Signal, -Ve and +Ve. Indicators: Dual ultra-bright red LEDs active in alarm. Sounder: Active in alarm. IP Rating: IP41 when correctly installed. Dimensions: 87 x 87 x 68mm (WxHxD). Mounts on 25mm UK single gang back box. NC809DBB Reset point c/w sounder Input: Voltage: 12V d.c.; Connections: Signal, -Ve and +Ve. Indicators: Red reassurance LED active in alarm. Sounder: Active in alarm. IP Rating: IP41 when correctly installed. Dimensions: 87 x 87 x 24mm (WxHxD). Mounts on 25mm UK single gang back box. Approved Document No: DNU0951001 Rev 2. We re s e rve the right to alter product specifications at our discretion and without prior notice. Errors and omissions excepted. This manual has been carefully checked prior to publication. However, no responsibility can be accepted by the manufacturer or distributors of this equipment for any misinterpretation of an instruction or guidance note or for the compliance of the system as a whole. Approved Document No: DNU0951001 Rev 2 Page 12 of 12

UPDATE TO BS8300 ADDENDUM TO NC951 INSTRUCTIONS BS8300 (the code of practice for the design of buildings and their approaches to meet the needs of disabled people) has recently been updated and includes some new information regarding the design of emergency assistance alarms and the location of devices used in them. Although the system design information included in our existing instructions is still fundamentally correct and applicable to many accessible toilet / emergency assistance alarm systems, your attention is drawn to the following with regard to the 2009 edition of BS8300:- 1. The recommended mounting height for reset buttons has changed. The standard now states they should be located with their bottom edge between 800mm and 1000mm above floor level. 2. The new 2009 standard includes a number of example accessible WC, changing place and accessible bedroom layouts that show ceiling pulls and reset points located in a variety of positions dependent on the application and other sanitary items used (wash basins, baths, etc). We therefore recommend you refer to the text and diagrams in BS8300 (2009) before designing and/or installing the system. Other/alternative standards of design and installation should always be adhered to where pertinent. NEW-IMPROVED CEILING PULL UNIT This kit now includes a new-improved ceiling pull unit with the following features:- Smaller, less obtrusive design Wider openings in the base for incoming cables Quicker installation - lid simply clicks into base and is secured in one twisting motion - no lid fixing screws required! Improved confidence light - central diffuser emits bright glow over a wider area, providing better contrast for the visually impaired Spare terminal (labelled +Ve but not electrically connected) for use as a wiring junction point if required Separate easy-to-fix pull cord - see cord installation hints and tips (right). Information on how to set the triangular bangles can be found inside the accessory pack. Wire the ceilng pull as detailed in the main instructions. Our main instructions will be updated to include the information on this addendum in due course. Approved document no. DNU8070022 Rev 2 Keep the cord and bangles clean and tidy by cutting the right hand corner of the bag they are supplied in, threading through 30cm of cord and following steps 1 to 3 below. The cord and bangles can now be left dangling from the ceiling pull until the bangles are ready to be fitted and the system commissioned 1 2 Thread the cord through the ceiling pull s centre eye Tie a secure stop knot and trim off any excess cord 3 Pull the cord tight to secure the knot inside the centre eye UPDATE TO BS8300 ADDENDUM TO NC951 INSTRUCTIONS BS8300 (the code of practice for the design of buildings and their approaches to meet the needs of disabled people) has recently been updated and includes some new information regarding the design of emergency assistance alarms and the location of devices used in them. Although the system design information included in our existing instructions is still fundamentally correct and applicable to many accessible toilet / emergency assistance alarm systems, your attention is drawn to the following with regard to the 2009 edition of BS8300:- 1. The recommended mounting height for reset buttons has changed. The standard now states they should be located with their bottom edge between 800mm and 1000mm above floor level. 2. The new 2009 standard includes a number of example accessible WC, changing place and accessible bedroom layouts that show ceiling pulls and reset points located in a variety of positions dependent on the application and other sanitary items used (wash basins, baths, etc). We therefore recommend you refer to the text and diagrams in BS8300 (2009) before designing and/or installing the system. Other/alternative standards of design and installation should always be adhered to where pertinent. NEW-IMPROVED CEILING PULL UNIT This kit now includes a new-improved ceiling pull unit with the following features:- Smaller, less obtrusive design Wider openings in the base for incoming cables Quicker installation - lid simply clicks into base and is secured in one twisting motion - no lid fixing screws required! Improved confidence light - central diffuser emits bright glow over a wider area, providing better contrast for the visually impaired Spare terminal (labelled +Ve but not electrically connected) for use as a wiring junction point if required Separate easy-to-fix pull cord - see cord installation hints and tips (right). Information on how to set the triangular bangles can be found inside the accessory pack. Wire the ceilng pull as detailed in the main instructions. Our main instructions will be updated to include the information on this addendum in due course. Approved document no. DNU8070022 Rev 2 Keep the cord and bangles clean and tidy by cutting the right hand corner of the bag they are supplied in, threading through 30cm of cord and following steps 1 to 3 below. The cord and bangles can now be left dangling from the ceiling pull until the bangles are ready to be fitted and the system commissioned 1 2 Thread the cord through the ceiling pull s centre eye Tie a secure stop knot and trim off any excess cord 3 Pull the cord tight to secure the knot inside the centre eye