Installation Instructions

Similar documents
Installation Instructions

Installation Instruction

Fig. 1--Typical Coil Installation

Installation Instructions

Installation Instructions

Installation Instructions

_"RETURN. s ) EVAPORATOR COIL _ DOWNFLOW FURNACE UPFLOW I R I! / _[_SUPPLY

Installation Instructions

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Installation Instructions

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

INSTALLATION INSTRUCTIONS TXV Coils EBU, EBA

INSTALLATION INSTRUCTIONS TXV Coils EBD, EBA

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

Installation Instructions Part No , Part No Part No

INSTALLATION INSTRUCTIONS TXV Coils EDM, EDD, EDA

PL Series Premier Indoor Plenum Coils

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

C7 Series Split System Uncased Indoor Coils

Installation Instructions

Installation Instructions

Installation Instruction

INSTALLATION INSTRUCTIONS

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

Owner s Information Manual

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC LIST OF SECTIONS LIST OF FIGURES

Installation Instructions

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

UPFLOW/DOWNFLOW COILS

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

INSTALLATION INSTRUCTIONS

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

Installation Instructions

Fig. 1 - Unit PHD4 and WPH4

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Installation Instructions

Cased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Installation Instructions

EVAPORATOR COILS Installation Manual CCG, VCG, MCG M Series Coils

Installation Instructions

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP MODELS: TABLE OF CONTENTS LIST OF FIGURES

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Installation Instructions

Installation Instructions

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY UIM-C-0214

Installation Instructions

Installation Instructions

Installation Instructions

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTIONS FOR RCQD COILS

MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER

Installation Instructions

Owner s Information Manual

Evaporator Coil. Installation Instructions GENERAL

Installation Instructions Part No

Installation Instructions

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY

INSTALLATION MANUAL WARNING WARNING FULL-CASED UPFLOW/COUNTERFLOW FOR COOLING/HEAT PUMPS FULL-CASED MULTI-POSITION FOR COOLING/HEAT PUMPS MODELS: CF

Product Data. FH4A Fan Unit. Sizes 001 thru 004

INSTALLATION INSTRUCTIONS

Installation Instructions

Evaporator Coil. Installation Instructions GENERAL

Product Data. FH4A Fan Unit. Sizes 001 thru 004

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

AVS Air Handlers Installation Manual for Classic SC, SD, and SDH

Installation Instructions

Residential Piping and Long Line Guideline

Fig. 1 - Unit PGD4, PGS4, WPG4

FAN UNIT FH4A Sizes 001 thru 004

Installation Instructions

Upflow/Downflow A-Coil Specifications

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

Product Data MECH. Mechanical Filter Air Cleaner

INSTALLATION & OPERATING INSTRUCTIONS AAW SERIES VERTICAL WALL MOUNT AIR HANDLER (ELECTRIC HEAT)

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual

GAW SERIES INSTALLATION & OPERATING INSTRUCTIONS VERTICAL WALL MOUNT AIR HANDLER (ELECTRIC HEAT)

Transcription:

Installation Instructions For Cased and Uncased Coils Upflow-Downflow Heating-Cooling CK5A, CK5B Cased CJ5A Uncased SUPPLY RETURN EVAPORATOR COIL DOWNFLOW UPFLOW SUPPLY Fig. 1 Typical Coil Installation A96244 NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing. Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warning or cautions attached to the unit. Consult local building codes and National Electrical Code (NEC) for special requirements. It is important to recognize safety information. This is the safety-alert symbol. When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. WARNING: Before installing or servicing system, always turn off main power to system. There may be more than 1 disconnect switch. Turn off accessory heater power if applicable. Electrical shock can cause personal injury or death. INTRODUCTION Use this instruction manual to install indoor coils on upflow or downflow furnaces. (See Fig. 1.) Do not install coil in horizontal position. Model CJ5A is an uncased bare coil, requiring a field-fabricated or accessory enclosure. Model CK5A is enclosed in a painted casing while model CK5B is available in an embossed unpainted casing. Form: IM-CJ5A-06 Cancels: IM-CJ5A-05 Printed in U.S.A. 12-97 Catalog No. 63CJ-5A2

FIELD SUPPLIED PLENUM FIELD SUPPLIED PLENUM 19 3 16 FACTORY COIL SUPPORT 1 2 FACTORY COIL SUPPORT 1 1 16 FIELD SUPPLIED TRANSITION PLENUM 2 1 4 MIN A 1 3 16 6 2 1 4 "A" "B" SEE TABLE 2 A97222 A97666 Fig. 2 Transition Required for Overhang Fig. 3 Correct Orientation of Coil Support on Furnace INSTALLATION PROCEDURE 1 INSPECT EQUIPMENT File claim with shipper if equipment is damaged. PROCEDURE 2 SELECT INSTALLATION PROCEDURE For uncased coils (CJ5A) follow: A. Upflow CJ5A Uncased Coil Installation. See Table 1 for dimensions and accessory part numbers. For cased coils (CK5A,CK5B) in upflow application follow: B. Upflow CK5A,CK5B Cased Coil Installation. See Table 2 for dimensions and overhang options. Note instructions for placement of coil casing on furnace. For cased coils (CK5A,CK5B) in downflow application follow: C. Downflow CK5A,CK5B Cased Coil Installation. Table 1 CJ5A Dimensions MODEL NUMBER TONNAGE METERING DEVICE PISTON NO. FLUSH FIT TO WIDTH (IN.) CJ5AXA018000AAAA 1-1/2 52 14-3/16 CJ5AXA024000AAAA 2 59 14-3/16 CJ5AXA030000AAAA 2-1/2 67 14-3/16 CJ5AXN036000AAAA 3 70 14-3/16 CJ5AXW024000AAAA 2 59 17-1/2 CJ5AXW030000AAAA 2-1/2 67 17-1/2 CJ5AXA036000AAAA 3 70 17-1/2 CJ5AXN042000AAAA 3-1/2 78 17-1/2 CJ5AXN048000AAAA 4 84 17-1/2 CJ5AXW036000AAAA 3 70 21 CJ5AXA042000AAAA 3-1/2 78 21 CJ5AXA048000AAAA 4 84 21 CJ5AXN060000AAAA 5 90 21 CJ5AXW048000AAAA 4 84 24-1/2 CJ5AXA060000AAAA 5 90 24-1/2 CJ5AXX060000AAAA 5 90 24-1/2 ACCESSORY CASING KCAKC0612ECC 17-3/16H x 14 3/16W x 21D 12 Casings/Pallet KCAKC0712ECC 19-1/8H x 17 1/2W x 21D 12 Casings/Pallet KCAKC0804ECC 24-15/16H x 21W x 21D 4 Casings/Pallet KCAKC0904ECC 24-15/16H x 24 1/2W x 21D 4 Casings/Pallet PROCEDURE 3 INSTALLATION OF COILS A. Upflow CJ5A Uncased Coil Installation NOTE: Face plate and suction grommet are shipped taped to underside of condensate pan. 1. Mount factory coil support (shipped with coil) directly on furnace when coil width matches furnace width. (See Fig. 2A.) See Fig. 3 for exact orientation of support shelf on furnace. 2

2. Uncased coils that overhang furnace must have field-supplied transition plenum. (See Fig. 2B.) 3. Slide coil into plenum opening. 4. Remove styrofoam shipping block and wire tie from refrigerant connections. 5. Insert refrigerant connections and drain stub through openings in face plate prior to brazing refrigerant lines to coil. Attach face plate to liquid line bracket using field supplied screws. 6. Cover plenum opening with field-supplied front panel. 7. When installing uncased coil into pre-installed accessory coil casing, use Table 1 to verify correct match. 8. Discard factory-supplied coil support when installing coil into accessory casing. NOTE: The factory recommends that the supplied coil support be used in all uncased installations. The side flange dimensions have been specifically designed to provide support and proper airflow. IMPORTANT: Locate caution label stapled to instruction sheet. Attach to right side of plenum or accessory casing. (See Fig. 4.) CAUTION AIR CONDITIONING COIL BEHIND THIS PANEL. DO NOT DRILL OR CUT PANEL UNTIL COIL LOCATION HAS BEEN VERIFIED BY REMOVING ACCESS COVER. Fig. 4 Plenum Caution Label A96359 NOTE: The uncased N-coil features an enclosure to direct airflow through the third coil slab. The cased version does not require an internal enclosure to direct airflow through the coil slabs because the casing serves this function. Use of a cased N-coil in an uncased application is not advised without making provision for airflow to be directed through all slabs. MODEL NUMBER TONNAGE Table 2 CK5A/CK5B Dimensions METERING DEVICE PISTON NO. FLUSH FIT TO WIDTH (IN.) SHELF WIDTH (SEE FIG. 3) DIM A) FITS NEXT SMALLER Equal Overhang Overhang with Transition *CK5(A,B)XA018000AAAA 1-1/2 52 14 3/16 *CK5(A,B)XA024000AAAA 2 59 14-3/16 12-7/8 *CK5(A,B)XA030000AAAA 2-1/2 67 14-3/16 CK5(A,B)XN036000ABAA 3 70 14-3/16 *CK5(A,B)XT036000AAAA 3 70 17-1/2 X CK5(A,B)XW024000AAAA 2 59 17-1/2 X X CK5(A,B)XW030000AAAA 2-1/2 67 17-1/2 X X 16-3/16 *CK5(A,B)XA036000ABAA 3 70 17-1/2 X X CK5(A,B)XN042000ABAA 3-1/2 78 17-1/2 X X CK5(A,B)XN048000ABAA 4 84 17-1/2 X X *CK5(A,B)XT042000AAAA 3-1/2 78 21 X *CK5(A,B)XT048000AAAA 4 84 21 X CK5(A,B)XW036000ABAA 3 70 21 X X 19-5/8 *CK5(A,B)XA042000ABAA 3-1/2 78 21 X X *CK5(A,B)XA048000ABAA 4 84 21 X X CK5(A,B)XN060000AAAA 5 90 21 X X *CK5(A,B)XT060000AAAA 5 90 24-1/2 X CK5(A,B)XW048000ABAA 4 84 24-1/2 X X 23-1/8 *CK5(A,B)XA060000AAAA 5 90 24-1/2 X X CK5(A,B)XX060000AAAA 5 90 24-1/2 X X *In these models the coil can be removed from the casing and installed as an uncased coil without need to field fabricate a coil enclosure to prevent air bypass. Use dimensions given on Fig. 3 to construct coil support shelf required to complete the uncased installation. Offset Left 3

COIL CASING WIDTH B REAR BRACKET 3 4 FLANGES (WHERE SHOWN) SIDE BRACKET SIDE BRACKET 19 1 2 (OUTSIDE) 2 1 4 FRONT BRACKET NOTE: WELD (3) PLACES IN (4) CORNERS A (INSIDE OPENING) OUTLET Dimension (In.) A B 12-3/4 17-1/2 16-1/16 21 19-9/16 24-1/2 Fig. 5 Recommended Transition B. Upflow CK5A/CK5B Cased Coil Installation 1. Set coil in place on upflow furnace discharge air opening. (See Fig. 1.) 2. When coil front width matches furnace front width, the coil can be placed directly on furnace. NOTE: When model T036, T042, T048, or T060, is applied to same width furnace, remove block-off plates at casing base by removing 2 screws per plate from side of casing. (See Fig. 7.) 3. Ensure coil is level for proper condensate drainage. Do not tip coil toward condensate drain. Coil enclosure need not be fastened or screwed to furnace. 4. Following are 3 instructions for alternative ways of overhanging coil on furnace: (See Fig. 6A,B,C.) T MODEL COILS APPLIED CENTERED OVER NARROW 1. There is no transition required for this application. 2. Remove coil from packaging and place on top of furnace with 1-5/8 in. overhang on both sides. (See Fig. 6A.) 3. Continue with normal installation practices. (See Procedure 4.) A, W, OR X MODEL COIL APPLIED CENTERED OVER NARROW WITH 2-1/4-IN. MINIMUM TRANSITION 1. Prepare transition, following recommended transition drawing. (See Fig. 5.) Fabricate a 2-1/4-in. tall (minimum) transition. 2. Place transition on top of gas furnace. (See Fig. 6B.) Secure with sheet metal screws. Place coil on top of transition. Make sure coil rests evenly on top of transition and gas furnace. 3. Secure coil to transition using sheet metal screws. 4. Continue with normal installation practices. (See Procedure 4.) NOTE: If coil (cased or uncased) is not being installed in the standard orientation (front of coil matching front of furnace) then coil must be raised 2-1/4 in. above furnace. A, W, OR X MODEL COIL APPLIED DIRECTLY ON TOP AND OFFSET TO THE LEFT ON NARROW 1. Notch support rail on underside of coil cabinet to provide clearance for gas furnace flange. This rail is not visible from front of coil. To locate position of notch, place coil directly on top of gas furnace with overhanging portion entirely on left side as in Fig. 6C. Mark location of gas furnace flange on coil casing. Remove coil from top of furnace. Using tin snips, make a notch in rail large enough to allow clearance for gas furnace flange. 2. Place coil on top of gas furnace. Make sure coil is shifted completely to left side, and notch is sufficient so coil rests on top of furnace cabinet. 3. Prepare and install block-off plate. (See Fig. 6C.) Using field-supplied sheet metal, cut a block-off plate to be attached to bottom left side of coil casing. This plate prevents air leakage from overhanging portion of coil. Attach plate using sheet metal screws. 4 A97232

2 1 4 MIN FIELD FABRICATED BLOCK OFF PLATE ALTERNATIVE A ALTERNATIVE B ALTERNATIVE C WRONG MODELS: T036, T042, T048, AND T060 ONLY Fig. 6 Alternative Coil Mounting Positions 4. Continue with normal installation practices. (See Procedure 4.) C. Downflow CK5A/CK5B Cased Coil Installation 1. Place N-coil on supply duct opening. 2. When coil width matches furnace width, furnace can be placed directly on CK5A/CK5B Cased Coil. NOTE: In downflow installation with a 4-way multipoise furnace, break off perforated duct flanges on furnace. (See Furnace Installation Instructions.) 3. Coils that underhang (narrower than furnace) must have a 2-1/4-in. long (minimum) field-fabricated transition between furnace and N-coil casing. 4. Coils that overhang (wider than furnace) do not require a transition in downflow application. However, a field-supplied furnace shelf should be constructed to fit furnace to coil opening. 5. Place furnace on top of N-coil casing, or field-supplied furnace shelf. PROCEDURE 4 CONNECT REFRIGERANT PIPING Use accessory tubing package or field-supplied tubing of refrigerant grade. Suction tube must be insulated. Do not use damaged, dirty, or contaminated tubing because it may plug refrigerant flow-control device. ALWAYS evacuate the coil and field-supplied tubing before opening outdoor unit service valves. PROCEDURE 5 CONNECT REFRIGERANT LIQUID AND SUCTION LINES For matched and mix-matched systems, use line sizes recommended in outdoor unit Installation Instruction. The coil can be connected to outdoor units using accessory tubing packages or field-supplied tubing of refrigerant grade. Always evacuate tubing and reclaim refrigerant when making connections or flaring tubing. Leak check connections before insulating entire suction line. A97607 CAUTION: required. If unit is to be installed on system with a thermostatic expansionvalve, removal of indoor coil piston is A. Suction Line Suction line is designed for field sweat connection. Line is plugged to keep out moisture and dirt. Remove these plugs only when ready to make connection. CAUTION: cloth. To avoid valve damage while brazing, wrap tubing or fittings with a heat-sinking material such as a wet B. System Refrigerant Control A refrigerant control device (bypass type piston) is factory supplied with coil. (See Tables 1 and 2.) The piston has a refrigerant metering hole through it, and is field replaceable. The piston shipped with the indoor coil may be different from the piston shipped with the outdoor condensing unit. If this is the case, you must replace the indoor piston. Always use the piston shipped with the outdoor condensing unit. 5

BLOCK-OFF PLATES Fig. 7-Block Off Plate Removal A97629 C. Liquid Line 1. Replace piston if required. Check the piston size stamped into side of brass hex nut. (See Fig. 8.) If this piston number does not match required piston shown on outdoor unit rating plate, replace indoor piston with piston shipped with outdoor unit. 2. When the piston is replaced, hand tighten the brass hex nut, then tighten with wrench 1/2 turn. 3. Remove rubber plug. 4. Liquid line is designed for sweat connection. CAUTION: Remove Teflon seal during brazing. Replace when fitting has cooled. PLUG 13 16 IN. BRASS HEX NUT PISTON RETAINER STRAINER PISTON DISTRIBUTOR 5 9 PISTON NUMBER STAMPED INTO SIDE OF NUT TEFLON SEAL 3 4 IN. BRASS HEX BODY Fig. 8 Refrigerant Control Device Components COPPER TUBE A96248 6

PROCEDURE 6 CONDENSATE DRAIN LINE CONNECTION The coil is designed to dispose of accumulated water through built-in condensate drain fittings. Two 3/4-in. female threaded pipe connections are provided in each coil condensate pan. Install a trap in condensate line for CJ5A, CK5A, or CK5B coil as close to coil as possible. Make trap at least 2-1/4 in. deep and no higher than the bottom of unit condensate drain opening. (See Fig. 9.) Pitch condensate line 1 in. for every 10 ft of length to an open drain or sump. UNIT 2 1 4 2 1 4 Fig. 9 Condensate Trap A95321 NOTE: If unit is located in or above a living space where damage may result from condensate overflow, a field-supplied, external condensate pan should be installed underneath entire unit, and a secondary condensate line (with appropriate trap) should be run from the unit into the pan. Any condensate in this external condensate pan should be drained to a noticeable place. As an alternative to using an external condensate pan, some localities may allow the running of a separate 3/4-in. condensate line (with appropriate trap) per local code to a place where the condensate will be noticeable. The owner of the structure must be informed that when condensate flows from secondary drain or external condensate pan, the unit requires servicing or water damage will occur. PROCEDURE 7 HUMIDIFIER APPLICATION When installing a humidifier in a system which contains an N-coil, consideration must be given to location of coil slabs. (See Fig. 10.) 1. Care must be taken to prevent damage of N-coil when attaching humidifier to coil casing or plenum. 2. Uncased N-coil is shipped with a label to be applied to plenum to indicate slab location. This is needed only in cases where humidifier is not installed with original equipment. Label will alert future service and installation technicians about coil slab location. 3. Ensure that humidifier has adequate airflow. SUPPLY EVAPORATOR N-COIL UPFLOW Fig. 10 Installation of Humidifier in System with N-Coil A96401 7

SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product, theory, and skills programs is available, using popular video-based formats and materials. All include video and/or slides, plus companion book. Classroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog. CALL FOR FREE CATALOG 1-800-962-9212 [ ] Packaged Service Training [ ] Classroom Service Training 1997 CAC/BDP P.O. Box 70, Indianapolis, IN 46206 imcj5a06 8 Book/Tab: 1/3d, 4/2d Catalog No. 63CJ-5A2