Instruction Manual August sitrans CU 02

Similar documents
Instruction Manual December 2001 ENACOCU02

CU-02 with Senaco Plus

Instruction Manual July 2008 TS-2 TEMPERATURE SENSOR

Instruction Manual April sitrans AS 100

Quick Start Manual July pointek CLS100

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH

multiranger 100 / 200

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Analog Room Pressure Monitor RPC Series

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH. Instruction Manual August 2002

Process Alarm Module RTA 421

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Oxygen (O2) Single-Point Gas Detection System

Functional Safety Manual June pointek CLS500/LC500

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

LC2200 Level Controller Installation and Maintenance Instructions

Carbon Monoxide Transmitter

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Combustible Gas Detection and Control System

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Product Manual SZ1145

Duct and Rough Service Carbon Monoxide Sensor

Two-Channel Gas Controller

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Product Manual SZ1144

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

Operating Instructions. For. Alarm Control Module. Model SSR 500

INSTALLATION INSTRUCTIONS

POINTEK CLS 200 OINTEK CLS 200 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual December 2001

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

EXTINGUISHING AGENT RELEASE MODULE

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Ultrasonic switch. Pointek ULS200. Quick Start Manual 03/2013. Milltronics

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Acoustic Sensors. Title page without bleed in RGB SITRANS AS100. Operating Instructions

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

DIGITAL METERS Large Display Temperature Meters Instruction Manual

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

B-40/B-41 Modulating Temperature Controller

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

MO n : 12JMC rév A

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

MTRA-FSP Level Control Relay. Installation & Operation Manual

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

CTT8 TEMPERATURE MONITOR DEVICE

Beacon 110 Gas Monitor Operator s Manual

Process & TeMPerATUre UniversAl input DigiTAl MeTers

10yr O2NE & Safe-Ox. User Manual

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

C-Bus Four Channel General Input Unit Installation Instructions

Pioneer-R16 Gas Monitor Operator s Manual

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Ammonia Leak Detector Manual

Pump-Down Controller MODEL 4052

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Cable Actuated Sensor Industrial User Scalable 4 20mA

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

General Specifications

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

Greentrol Automation, Inc.

SAFETY INFORMATION AND WARNINGS

Reyrolle Protection Devices. 7PG26 DAD High Impedance Current Relay. Answers for energy

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

BC3250. Blowdown Controller

Multi-Gas-Controller MGC2

Tri-Stack Smart System

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

UDC100 Universal Digital Controller Specifications

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

UNC100 Integra Manual

Universal Gas Detector

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Pump-Up Controller MODEL 4062

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Beacon 200 Gas Monitor Operator s Manual

PRODUCT CONFORMITY CERTIFICATE

LC1350 Level Controller

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Transcription:

Instruction Manual August 2005 sitrans CU 02

Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel: This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards. Unit Repair and Excluded Liability: The user is responsible for all changes and repairs made to the device by the user or the user s agent. All new components are to be provided by Siemens Milltronics Process Instruments Inc. Restrict repair to faulty components only. Do not reuse faulty components. Warning: This product can only function properly and safely if it is correctly transported, stored, installed, set up, operated, and maintained. Note: Always use product in accordance with specifications. Copyright Siemens Milltronics Process Instruments Inc. 2005. All Rights Reserved This document is available in bound version and in electronic version. We encourage users to purchase authorized bound manuals, or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments Inc. Siemens Milltronics Process Instruments Inc. will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions. Disclaimer of Liability While we have verified the contents of this manual for agreement with the instrumentation described, variations remain possible. Thus we cannot guarantee full agreement. The contents of this manual are regularly reviewed and corrections are included in subsequent editions. We welcome all suggestions for improvement. Technical data subject to change. MILLTRONICS is a registered trademark of Siemens Milltronics Process Instruments Inc. Contact SMPI Technical Publications at the following address: Technical Publications Siemens Milltronics Process Instruments Inc. 1954 Technology Drive, P.O. Box 4225 Peterborough, Ontario, Canada, K9J 7B1 Email: techpubs.smpi@siemens.com For a selection of Siemens Milltronics level measurement manuals, go to: www. siemens.com/processautomation. Under Process Instrumentation, select Level Measurement and then go to the manual archive listed under the product family. For a selection of Siemens Milltronics weighing manuals, go to: www. siemens.com/processautomation. Under Weighing Technology, select Continuous Weighing Systems and then go to the manual archive listed under the product family. Siemens Milltronics Process Instruments Inc. 2005

Table of Contents About the SITRANS CU 02...1 Features...1 Specifications...2 Installation...3 Mounting...3 Rail Mounting...4 Interconnection...5 Connection Layout...5 SITRANS AS 100 Sensor Connection...5 Operation...7 Start Delay...7 Display...7 Relay...7 Analog Output...8 Setting Up... 10 Operating Values...11 Programming... 12 Calibration: 0-100% / 4-20 ma...12 Relays...12 Ancillary Functions...13 Parameter List...14 Security Alteration...15 Maintenance... 15 i

ii

About the SITRANS CU 02 Note: SITRANS CU 02 is to be used only in the manner outlined in this instruction manual. The SITRANS CU 02 is an alarm control unit for use with SITRANS AS 100 acoustic sensor. Features LCD display 2 SPDT (form C) relays 4-20 ma output, isolated programmable start up delay programmable alarm delay 7ML19985DN01 SITRANS CU 02 INSTRUCTION MANUAL Page 1

Specifications Power: see nameplate for voltage configuration (100/115/200/230 V ac ±15%, 50/60 Hz, 10 VA) Environmental: location: indoor altitude: 2000 m max ambient temperature: -20 to 50 C (-4 to 122 F) relative humidity: 80% for temperatures up to 50 C installation category: II pollution degree: 2 Sensor Excitation: 26 Vdc nominal, 70 ma max Input: SITRANS Sensor 0 10 Vdc Display: liquid crystal three 9 mm (0.35") digits multisegment graphic for operation status Relay: 2 alarm/control relays 1 form C SPDT contact per relay, rated 5 A at 250 V ac non inductive Analog Output: isolated 4-20 ma 750 Ω load max Cable: analog output: Belden 8760 18AWG shielded twisted pair or equivalent latch contact input: Belden 8760 18AWG shielded twisted pair or equivalent Accuracy: ±0.02V (display) or ±40µA (ma output) Enclosure: 55 mm W x 75 mm H x 110 mm D (2.2" W x 3" H x 4.4" D) polycarbonate mounting: DIN rail (DIN 46277 or DIN EN50022) wall / panel mount Ingress Protection: IP 20 Approval: CSA general purpose Weight: 550 g (18 oz) Page 2 SITRANS CU 02 INSTRUCTION MANUAL 7ML19985DN01

Installation Notes: Installation shall only be performed by qualified personnel and in accordance with local governing regulations. This product is susceptible to electrostatic shock. Follow proper grounding procedures. Mounting Dimensions 110mm (4.4") 75mm (3") 55mm (2.2") 38mm (1.5") 61mm (2.4") 4.5 x 5.75 mm (1.8" x 0.2") mounting slot (2 places) Wall / Panel Mounting 38mm (1.5") 61mm (2.4") drill and tap for 4mm (#8) screw, (2 places) 7ML19985DN01 SITRANS CU 02 INSTRUCTION MANUAL Page 3

Rail Mounting Mounting Removal Page 4 SITRANS CU 02 INSTRUCTION MANUAL 7ML19985DN01

Interconnection Connection Layout 1 2 3 4 5 6 7 8 + ma out 4-20 Vsup com Vsens latch RL1 RL2 L1 L2 N 9 10 11 12 13 14 15 16 WARNING: All field wiring must have insulation suitable for at least 250V. Relay contact terminals are for use with equipment having no accessible live parts and wiring having insulation suitable for a least 250 V. The maximum allowable working voltage between adjacent relay contacts shall be 250 V. SITRANS AS 100 Sensor Connection Standard Temperature Version or* red black green black black white shield 3 4 5 8 Vsup com Vsens Extended Temperature Version or* red black orange green brown yellow *sensor range selection high sensitivity range = red and green to Vsup low sensitivity range = red to Vsup and green to com 3 4 5 8 Vsup com Vsens *sensor range selection high sensitivity range = red and orange to Vsup low sensitivity range = red to Vsup and orange to com 7ML19985DN01 SITRANS CU 02 INSTRUCTION MANUAL Page 5

Relay Output Connection* Auto Reset (P14 / 24 = 0) Manual Reset (P14 / 24 = 1) reset button 1 2 3 4 5 6 7 8 + ma out 4-20 Vsup com Vsens latch RL1 RL2 L1 L2 N 9 10 11 12 13 14 15 16 N.O. COM N.C. N.O. COM N.C. All relays are certified for use in equipment where the short circuit capacity of the circuits in which they are connected is limited by fuses having ratings not exceeding the rating of the relays. *refer to Operation \ Alarm Analog Output Connection Power Connection to customer instrumentation 4-20 ma isolated output into 750 Ω max 1 2 3 4 5 6 7 8 + ma out 4-20 Vsup com Vsens latch The equipment must be protected by a 15 A fuse or circuit breaker in the building installation. A circuit breaker or switch in the building marked as the disconnect switch shall be in close proximity to the equipment and within easy reach of the operator. Refer to nameplate for voltage requirement Page 6 SITRANS CU 02 INSTRUCTION MANUAL 7ML19985DN01

Operation Start Delay On initial powering of the SITRANS CU 02, the start delay circuit prevents the relays from going into alarm for the period of time programmed (parameter P80). Display program alphanumeric relay 1 alarm flag % percent reading relay 2 alarm flag parameter value The SITRANS CU 02 normally displays the input signal level (Vsens) from the SITRANS sensor in volts, or in percentage of the programmed span (P3 P2). The selection is made while viewing Vsens. Press: for percent Press: for volts Damping is provided to slow the response of the display when rapid or minor fluctuations in the process or machinery operation are encountered. The greater the damping value (P86), the slower the response. Relay The SITRANS CU 02 has two onboard programmable relays (P10/20). Under normal operation, the relays are energized (normally open contact closed). Under alarm condition, the `alarm' flag starts flashing immediately, indicating that the relay delay (P13/ 23) has started counting. If the alarm condition ceases before the relay delay expires, the flashing `alarm' flag is aborted. If the relay delay expires, the relay de-energizes and the contacts change state. The `alarm' flag ceases flashing and remains on. Upon resumption of normal operating condition, the `alarm' flag disappears. The relay and relay delay reset manually or automatically depending on the mode selected (P14/24). If 7ML19985DN01 SITRANS CU 02 INSTRUCTION MANUAL Page 7

automatic, the reset is immediate. If manual, the reset occurs upon actuation of the reset button (latch). Each relay is programmable for either: high alarm: low alarm: out of bound: in bound: alarm condition occurs when the sensor signal level (%) is of a greater value than the high% setpoint alarm condition occurs when the sensor signal level (%) is of a lesser value than the low% setpoint alarm condition occurs when the sensor signal level (%) is of a greater value than the high % alarm setpoint or of a lesser value than the low% alarm setpoint alarm condition occurs when the sensor signal level (%) is of a value gbetween the low% and high% alarm setpoints on off on off on off on off 0 80 100 e.g. alarm above 80% 0 20 100 e.g. alarm below 20% 0 20 80 100 e.g. alarm beyond 20% and 80% 0 20 80 100 e.g. alarm between 20% and 80% The individual relay functions in combination provide: high% and high-high% alarm high% and low% alarm high% and bound alarm low% and low-low% alarm low% and bound alarm bound 1 and bound 2 alarm Note: if the SITRANS AS 100 sensor is located in areas with high RF noise, then the alarm setpoints should be set to 0.50 V above or below the fault/no fault conditions Analog Output The SITRANS CU 02 provides an isolated analog 4-20 ma output by calibration of the 4 and 20 ma levels to the operating span of the input signal (Vsens) from the SITRANS sensor. In the case where Vsens passes the lower and upper limits of the span, low and high ma limits are factory set to nominal values of 2 and 22 ma respectively, providing indication of overrange activity. Damping is provided to slow the response of the analog output when rapid or minor fluctuations in the process or machinery operation are encountered. The greater the damping value (P85), the slower the response. Page 8 SITRANS CU 02 INSTRUCTION MANUAL 7ML19985DN01

Security The SITRANS CU 02 is factory shipped with security (P 1) disabled, allowing program access. If it is desired to deny programming access (viewing access is not restricted), security can be enabled by entering the enable code. If it is desired to regain programming access, the disable code must be entered. Refer to Security Alteration. Parameter Reset A master reset (P99) is provided to automatically reset all programming parameters to their factory values. However, if it is desired to reset an individual parameter, this can be done by entering its factory value, as given in Parameter List. 7ML19985DN01 SITRANS CU 02 INSTRUCTION MANUAL Page 9

Setting Up To Access Program: Press Display run display program starts at parameter 1 To Select a Parameter: to scroll up or down to desired parameter To View a Parameter Value: select parameter, e.g. P3 display parameter value, e.g. 2.50 exit To Change a Parameter Value: To Return to Run Display Security must be disabled! Must be pressed to Save change! select parameter, e.g. P3 display parameter value, e.g. 2.50 increase or decrease to the desired value If no response, security not disabled! save and exit from the parameter display, e.g. P3 exit program and return to run display Page 10 SITRANS CU 02 INSTRUCTION MANUAL 7ML19985DN01

Operating Values With the SITRANS Sensor and Control Unit properly mounted, connected and powered. Run the material or machinery through its range of operation. Note the following values where applicable: normal operating level V norm = - abnormal operating level V abn = - Where applicable values are unobtainable, they can be estimated and entered while programming. 7ML19985DN01 SITRANS CU 02 INSTRUCTION MANUAL Page 11

Programming Note: Security must be disabled to set programming functions. Calibration: 0-100% / 4-20 ma calibrate the 0% / 4 or 20 ma level by entering the value of V norm into P 2. calibrate the 100% / 20 or 4 ma level by entering the value of V abn into P 3. The difference between P 2 and P 3 must be at least 0.2 V for full 4-20 ma span. Relays For precise determination of alarm setpoints, view the run display in percent and run the material or machinery through its range of operation. Note the % values corresponding to the alarm points. Note: The setpoints should be 0.50 V above or below the fault/no fault condition if the sensor is installed in high RF noise locations. Relay 1 enable, P10 = 1 setpoint: for high% alarm, P11 = enter setpoint value in % P12 = 0 for low% alarm, P11 = 0 P12 = enter setpoint value in % for out of bound alarm, P11 = enter high% setpoint value in % P12 = enter low% setpoint value in % for in bound alarm, P11 = enter low% setpoint value in % P12 = enter high% setpoint value in % relay delay set (1-999 s), P13 reset select, P14 auto = 0 manual = 1 Page 12 SITRANS CU 02 INSTRUCTION MANUAL 7ML19985DN01

Relay 2 enable, P20 = 1 setpoint: for high% alarm, P21 = enter setpoint value in % P22 = 0 for low% alarm, P21 = 0 P22 = enter setpoint value in % for out of bound alarm, P21 = enter high% setpoint value in % P22 = enter low% setpoint value in % for in bound alarm, P21 = enter low% setpoint value in % P22 = enter high% setpoint value in % relay delay set (1-999 s), P23 reset select, P24 auto = 0 manual = 1 Ancillary Functions Damping ma output damping adjust (typical value, 1-50), P85 display damping adjust (typical value, 1-50), P86 7ML19985DN01 SITRANS CU 02 INSTRUCTION MANUAL Page 13

Parameter List P- 1 security, reference = 500 ƒ P- 2 0% calibration / 4 ma (V sens = 0-7.3 V) ƒ=0.50 P- 3 100% calibration / 20 ma (Vsens = 0.2-7.5 V) ƒ=2.50 P-10 relay 1, operation: 0 = disabled ƒ 1 = enabled P-11 relay 1, high alarm setpoint (0 = disabled,1 to 100%) ƒ = 80 P-12 ƒ= 20 relay 1, low alarm setpoint (0 = disabled,1 to 100%) P-13 relay 1, delay (1 ƒ to 999 s) P-14 relay 1, latch: 0 = auto reset ƒ 1 = manual reset P-20 relay 2, operation: 0 = disabled ƒ 1 = enabled P-21 ƒ= 70 relay 2, high alarm setpoint (0 = disabled, 1 to 100%) P-22 relay 2, low alarm setpoint (0 = disabled, 1 to 100%) ƒ = 30 P-23 relay 2, delay (1 ƒ to 999 s) P-24 relay 2, latch: 0 = auto reset ƒ 1 = manual reset P-80 start delay (1 to 999 s) ƒ=10 P-85 damping, ma out (1 ƒ to 999) P-86 damping, display (1 ƒ to 999) P-90 software revision number P-99 reset: 0 = normal ƒ 9 = reset ƒ factory setting accessible only if relay operation function is enabled Page 14 SITRANS CU 02 INSTRUCTION MANUAL 7ML19985DN01

Security Alteration To Enable Security: Press Display security disabled, programming access granted reference value enable code To Disable Security: security enabled, programming access denied security enabled, programming access denied reference value disable code security disabled, programming access granted Maintenance SITRANS CU 02 requires no maintenance, however a program of periodic checks is recommended. 7ML19985DN01 SITRANS CU 02 INSTRUCTION MANUAL Page 15

Notes

Notes

www.siemens.com/processautomation Siemens Milltronics Process Instruments Inc. 1954Technology Drive, P.O. Box 4225 Peterborough, ON, Canada K9J 7B1 Tel: (705) 745-2431 Fax: (705) 741-0466 Email: techpubs.smpi@siemens.com Siemens Milltronics Process Instruments Inc. 2005 Subject to change without prior notice *7ml19985DN01* Printed in Canada Rev. 1.3