Thermostat KPU. Data sheet

Similar documents
Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure switch KPU. Data sheet

y Small dimensions. Easy to install in refrigerated counters or cold rooms

TC-5231 Series, TC-5232, & TC-5241 Series

Thermostat RT. Data sheet

Thermostat, Differential thermostat RT

When ordering, please state type and code number. Max. Type - Capillary sensor of tube temp. charge length. C m

Powers Controls ET 134 Low Temperature Detection Thermostat

TEMPERATURE & PRESSURE CONTROLS

For Technical Service Telephone Facsimile

Commercial Refrigeration Catalog

Powers Controls Low Temperature Detection Thermostat

The T6140A,B Remote Bulb Temperature Controller

A11 Series Low Temperature Cutout Controls

Temperature, Mechanical

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

59T, 66T Series Electric Water Heater Controls

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

Technical Instructions Document No P25 ET September 28, ET 141 Electric Surface Mounted Thermostat.

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois

MR3CCUHV Temperature/Defrost Control

T7079A,B Solid State Remote Temperature Controllers

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

Tubular Industrial Process

Electromechanical cold controls for refrigerators and freezers MAKING MODERN LIVING POSSIBLE. Type description

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 14 Automatic Control Components and Applications

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

temperature Controllers

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Thermostat Catalog 2004

BULLETIN 600 SINGLE PHASE

Powers TM Controls ET 134 Line Voltage Room Thermostats

Thermostat Catalog 2004

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Tubular Industrial Process

PARAGON Commercial Refrigeration Controls

Schneider Electric Erie T155 Series

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

Centro-Matic Automated Lubrication Systems System Controls

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

Brasch Hazardous Location Unit Heaters

Easy. Products and technologies for all your application needs, today and tomorrow. Quick Select Guide 2017

Temperature & Humidity Controllers

CONDENSING UNITS. Equipped with the Award Winning Comfort Control System UARL- JEZ. Four Models

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

Ultra-Safe EXP Unit Heater

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Data sheet Thermostatic sensors type RA 2000

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6

Commercial High-Efficiency Condensing Units

Precise Temperature Control; Compact Footprint

59T, 66T Series Electric Water Heater Controls

AIR CONDITIONER ELECTRONIC CONTROL

AS570 Chill-Out Combination Sensor Installation and Operating Instructions

FX5 Series Explosion-Proof Electric Air Heaters

DOO IK ENG PRODUCT CATALOG DOO IK ENG TEMPERATURE SENSOR PRESSURE SWITCH NON FLOW SWITCH THERMOMETER

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

June 2001 / BULLETIN Way Valves. The right solenoid valve for any job.

Electromechanical cold controls for refrigerators and freezers

Thermostats and Accessories

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Check valve Types NRV and NRVH

12,000 BTU Evaporative Portable Air Conditioner

CHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX

! WARNING. Before using product, read and understand instructions.

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

1.7 CU.FT. REFRIGERATOR INSTRUCTION MANUAL MCBR170BMD

Description. Construction

HUMIDISTATS and Electronic humidity controls

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

INSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch

2.4 Cu. Ft. Compact Refrigerator

KUH. Horizontal Unit Heater. Applications. Description

Refrigeration Systems and Accessories

LIQUID REFRIGERANT CONTROL IN REFRIGERATION AND AIR CONDITIONING SYSTEMS

XT Series Thermostats

W43A Humidistat. Features and Benefits

INSTALLATION INSTRUCTIONS

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

Atlas Copco. Oil-sealed rotary screw vacuum pumps GVS , cfm

PAJ3. Product Specifications

Series A28 Two stage Thermostats. Feature and Benefits

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

! WARNING. Before using product, read and understand instructions.

Tubular Industrial Process

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Immersion Heaters. Screw Plug Immersion Heater

The Saturation process

Owners Manual Refrigerated Air Dryer MHT SERIES

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit

A19, A28 Series Thermostats for Agricultural Buildings

BASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

HLA Series Hazardous Location Fan Forced Unit Heater

Table of Contents. Protective Relays

User Manual. Commercial Chest Freezer User s Manual 360CF5, 360CF8, 360CF14, 360CF18

Transcription:

Data sheet Thermostat KPU The KPU Thermostats are temperature controlled electrical switches, which are applied for regulation and safety monitoring of refrigeration and air conditioning systems. KPU sensors are available with vapor charge or with adsorption charge. The Thermostats with adsorption charge are widely used to give frost protection, while vapor charged sensors are used where small differential is required. All KPU Thermostats have a single pole double throw (SPDT) contact system. The position of the switch depends on the thermostat setting and the bulb temperature. Features Wide temperature regulating range allows use in low, medium, and high temperature refrigeration application and air-conditioning systems Snap-action electrical contacts minimize chatter, bounce and wear, and ensure long-term electrical and mechanical reliability Fingertip manual trip feature allows contact function testing without tools Easily replaces other manufacturers thermostats Ultra-short bounce time Long operating lifetime Vibration and shock resistant SPDT switch allows NC or NO function option as well as alarm capability Automatic and manual reset versions available Approvals UL listed for USA and Canada, file E31024 Danfoss DCS (jmn) 2016.08 DKRCC.PD.CA0.F6.22 520H11320 1

Technical data Ambient temperature Cable entry Maximum wire dimension -40 122 F, 175 F up to 2 hours 7/8 in cable entry for 1/2 in male pipe thread connection (conduit boss) 10 AWG Enclosure ~NEMA 1 Switch SPDT single pole double throw NAM rating Alternating current FLA = 24 A at 120 V AC 24 A at 240 V AC LRA 1 ) = 144 A at 120 V AC 144 A at 240 V AC Contact load Direct current 12 W pilot duty at 240 V DC 1 ) LRA is rated for make only European rating (acc. to EN 60947) Alternating current Direct current AC1: 16 A, 400 VA AC3: 16 A, 400 VA DC13: 12 W, 220 V control current Regulating ranges in [ F] KPU 61 KPU 62 (room sensor) KPU 63 KPU 68 (room sensor) KPU 69 KPU 62 KPU 71 KPU 73 KPU 74 KPU 75 KPU 77-50 0 50 100 150 2 520H11320 DKRCC.PD.CA0.F6.22 Danfoss DCS (jmn) 2016.08

Ordering Type Bulb type Range at lowest temperature setting Differential at highest temperature setting Max. bulb temp. Reset function Capillary tube length Code no. [ F] [ F] [ F] [ F] [in] Vapour 1 ) KPU 61 A -20 60 10 40 2.5 13 250 auto. 80 060L5201 KPU 61 B -20 60 10 40 2.5 13 250 auto. 80 060L5203 KPU 61B B -20 60 fixed 11 fixed 3.5 250 man. 3 ) 80 060L5204 KPU 61B B -20 60 fixed 11 fixed 3.5 250 man. 3 ) 200 060L5205 KPU 62 C1-20 60 10 40 2.5 13 250 auto. room sensor 060L5206 KPU 61 B -20 60 10 40 2.5 13 250 auto. 4 ) 80 060L5210 KPU 63 A -60 15 18 125 5 15 250 auto. 80 060L5213 KPU 63 B -60 15 18 125 5 15 250 auto. 80 060L5214 KPU 68 C1 25 95 8 45 3 13 250 auto. room sensor 060L5215 KPU 69 B 25 95 8 45 3 13 250 auto. 80 060L5217 Adsorption 2 ) KPU 62 C2-20 60 9 36 3 14 175 auto. 4 ) room sensor 060L5207 KPU 73 E3-15 60 6.5 32 5 50 175 auto. 80 060L5208 KPU 73 E1-15 60 22 125 15 45 175 auto. 80 060L5209 KPU 73B E3-15 60 fixed 6 fixed 6 175 man. 3 ) 80 060L5211 KPU 73 D -15 60 6 35 5 32 175 auto. 80 060L5212 KPU 71 E2 25 70 5.5 18 4 16 175 auto. 80 060L5218 KPU 71B E2 25 70 fixed 5 fixed 5 175 man. 3 ) 80 060L5216 KPU 74 E1 0 80 9 35 9 35 175 auto. 80 060L5219 KPU 74B E1 0 80 fixed 10 fixed 10 175 man. 3 ) 80 060L5220 KPU 75 F 30 95 6 29 4.5 21.5 230 auto. 80 060L5221 KPU 77 E3 60 140 6 18 6.3 18 265 auto. 80 060L5223 1 ) Bulb must be installed in colder position than thermostat housing and capillary tube. 2 ) Bulb can be placed warmer or colder than thermostat housing and capillary tube, but variations from 70 F ambient temperature will influence the scale accuracy. 3 ) Manual minimum reset. Marked with letter B. Fixed differential. These controls have no hand knob. 4 ) With manual switch and top plate. Contact system Switch type single pole double throw Switch action Applicaton 1. Terminals 1 4 close high and open low Terminals 1 2 can be used as low temperature alarm 2. Terminals 1 2 open high and close low Terminals 1 4 can be used as high temperature alarm 1. Low temperature cut-out 2. High temperature cut-out Danfoss DCS (jmn) 2016.08 DKRCC.PD.CA0.F6.22 520H11320 3

Design / Function Key sketch of KPU Thermostat KPU Thermostat without front cover 1. Temperature setting spindle 2. Differential setting spindle 3. Main spring 4. Differential spring 5. Bellows 6. Capillary tube 7. Main arm 8. Switch 9. Cable entry 11. Temperature sensor 12. Setting knob 13. Differential setting screw 14. Control terminals 15. Ground terminal 16. Contact housing Switches in KPU Thermostats have a snap-action function, triggered when cut-in or cut-out temperature is reached. Snap-action creates a number of advantages: High contact load capability Ultra-short bounce time Long mechanical and electrical life High resistance to pulsation and vibration Vibration resistance up to 4 g in range 0 1000 Hz Long mechanical and electrical service life Danfoss DCS (jmn) 2016.08 DKRCC.PD.CA0.F6.22 520H11320 4

Terminology Set point A predetermined value to which a thermostat is adjusted and at which it performs its intended function. Differential The differential is the difference between the cutin and cut-out temperatures. The differential is necessary for satisfactory automatic operation of the controlled system. Mechanical differential (intrinsic differential) The mechanical differential is the differential set by the differential spindle. Snap function A specific contact force is maintained until snap is initiated. The time over which contact force reaches zero is a few milliseconds; therefore, contact bounce due to vibration, for example, cannot occur at cut-out. The snap-action contact system will continue to function even when micro-welds are created between the contacts during cut-in. The force created to separate the contacts is strong enough to instantly shear off all contact surface welds that may have been created by cut-in action. These design features ensure that the cut-out setting of the KPU thermostat remains highly accurate and completely independent of the magnitude of the current load. Reset 1. Manual reset: A unit with manual reset can only be restored to operational mode by activating the external reset button. On min. reset units the set value is equal to the cut-out value for falling temperature. On max. reset units the set value is equal to cut-out value for rising temperature. 2. Automatic reset: A unit with automatic reset is restored to operational mode automatically. FLA Motor Full Load Amperes FLA is the largest current that a motor or other device is designed to carry at rated voltage and other specific conditions. Also often called current at rated conditions. LRA Locked Rotor Amperes LRA is the largest current that the motor is designed to carry with shaft or rotor immobilized. Setting and resets Thermostats with automatic reset Set the cut-in temperature on the RANGE scale. Set the differential on the DIFF scale. The controlled system will start at the temperature set on the RANGE scale and will be stopped when the temperature falls the number of degrees set on the DIFF scale. Please note that the differential scale is only a reference. The exact value of distances on the scale depends on where in its range the control cut-in is set. Use the differential scale as a guide, and if precise function is required, establish the differential setting by comparing function with an accurate thermometer in the controlled zone. If the compressor does not stop at the desired low temperature, check the differential to ensure that it is not set at too high a value. The thermostat automatically resets and the compressor starts once the temperature rises above the range scale setting. Thermostats with manual minimum reset Set the cut-out temperature on the range scale. The differential is fixed. Restart the compressor by pressing the reset button after the temperature of the sensor rises to a value equal to the range scale setting plus the fixed differential. Thermostats with manual maximum reset Set the cut-out temperature on the range scale. The differential is fixed. Restart the compressor by pressing the reset button after the temperature of the sensor falls to a value equal to the range scale setting minus the fixed differential. Danfoss DCS (jmn) 2016.08 DKRCC.PD.CA0.F6.22 520H11320 5

Charges 1. 2. Bellows Bellows Capillary tube Capillary tube Sensor Sensor The sensor contains saturated vapor with a small quantity of liquid. When temperature rises, liquid evaporates, and pressure inside the sensor increases. After all of the liquid has evaporated, additional heat results in only a small pressure rise inside the element. s are appropriate for low temperature applications and others where the bellows must be protected from deformation by ambient temperature. The sensing element must be colder than the bellows at all times so that condensation of evaporated fluid occurs in the element only, and not in the bellows. As long as the sensor is the coldest part of the thermostat, ambient temperature has no effect on regulating accuracy. Sensors with adsorption charges contain a superheated gas together with a solid having a large adsorption surface. The sensor can be placed in zones that are warmer or colder than the control housing and capillary tube, but variations of more than 70 F may influence scale accuracy. Dimensions of KPU without capillary tube All thermostats are supplied with universal mounting bracket and mounting screws as standard accessory. Approximate weight of the bracket and mounting screws: 0.615 lb Net weight of KPU without capillary tube: Net weight of 80 in capillary tube: Net weight of 200 in capillary tube: ~ 0.77 lb ~ 0.17 lb ~ 0.43 lb Danfoss DCS (jmn) 2016.08 DKRCC.PD.CA0.F6.22 520H11320 6

Charges KPU 61 KPU 63 A Straight capillary tube Sensing length: 15 in a = 3 1 /8 in KPU 61 KPU 69 B Remote air coil b = 2 3/4 in KPU 62 KPU 68 KPU 62 C Room sensor C1 a = 1 1/2 in b = 1 1/4 in Room sensor C2 a = 1 in b = 3 in KPU 73 D Double contact remote bulb b = 3 3/8 in NOTE! Can not be used in sensor pocket! KPU 73, KPU 74 KPU 71, KPU 75 KPU 73, KPU 77 E Remote bulb E1 a = 1/4 in b = 3 3/4 in E2 b = 4 1/2 in E3 b = 3 3/8 in KPU 75 F Remote duct coil a = 1 in b = 3 5/8 in Danfoss DCS (jmn) 2016.08 DKRCC.PD.CA0.F6.22 520H11320 7