TS700. Intruder Alarm Control Panel OPEN ENT 0 ESC

Similar documents
TS700. Intruder Alarm Control Panel ENT 0 ESC

TS2500. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT ESC. Setting the System. Unsetting the System RE SET

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

M800, M800iD Plus, M1000 and M3000. User's Guide

TS5160. Installation & User Guide. Compatible Equipment. CPA6 0M - Output Module Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only)

HARDWIRED CONTROL PANELS

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u

USER GUIDE HARDWIRED CONTROL PANELS

2200 and 2200L ALARM CONTROL SYSTEMS

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

TS700. Intruder Alarm Control Panel. Installation & Programming Instructions OPEN

HARDWIRED CONTROL PANELS

Master User Guide Premier Elite Series

USER GUIDE HARDWIRED CONTROL PANELS

USER GUIDE HARDWIRED CONTROL PANELS

Scantronic Leading the way in security

Manager Guide. Indications on the system. Using System. Indications

THANK YOU FOR VOTING TEXECOM THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels 1 INS167

Scantronic Leading the way in security

USER GUIDE. Security Control Panels INS046-7

Racal-Guardall. Countess. User Instructions. Countess

Summit 3208GLD USER MANUAL. Electronics Line

THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels

CPA6. Installation & User Guide. Intelligent Security & Fire Ltd. Compatible Equipment

SECURIT 700L USER MANUAL

16 and 16 plus User s Guide

Welcome to. Welcome to Security and Peace of Mind CASTLE CARE TECH CARE TECH CARE TECH CARE TECH

Intelligent Security & Fire Ltd. PX Control Panel. User Manual. Issue C

SECURIT 703 USER MANUAL

NX-148 LCD CODE PAD TABLE OF CONTENTS

SECURIT 700L PLUS ENGINEERING MANUAL

ALARM SYSTEM USER GUIDE

Intruder alarm system Operating Instructions

AP10LED 10 Zone onboard LED Alarm Panel. Engineering Manual

Version 1.03 January-2002 USER S MANUAL

AXI LED USER MANUAL (REV. 1.0)

Watchguard WGAP864 User Manual

Security System. User s Guide for the Text Command Center

Accenta/Optima. User Guide. UK Security Panels. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number:

Galaxy Flex V3. User Guide. Honeywell Security. This user manual is located at

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panel with Communicator Interface

Installation Manual Premier 412/816/832. Issue 10

5 Sounds and Indications

INSTALLATION MANUAL SECURIT 802 CONTROL PANEL

Security System. User Guide for the LED Command Center

Introduction. When using an LED keypad for Abacus 6P (or some older Abacus panels) refer to the LED Operator instructions guide (Part No. Y6055).

Contents. Glossary

PYRONIX LIMITED, Pyronix House, Braithwell Way, Hellaby Rotherham South Yorkshire S66 8QY England

Microprocessor Intruder Alarm System User Guide

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

HILLS Series LED Code Pad User Manual

USER MANUAL CEF AP28 CONTROL PANEL

D1265. User's Guide. Touchscreen Keypad

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

Solution 880 Operators Manual. Issue 1.00

QUICK CONSUMER REFERENCE GUIDE

2000 Series. Program Entry Guide. Control Panels

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

IDS816 User Manual H Issued January 2009

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

PARAGON PLUS USER INSTRUCTIONS USER INSTRUCTIONS J?>5 J?>5 J?>5 J?>5 J?>5 J?>5 B??=

U ser's Guide PC6010

Using Your. Security System With LED Keypad S5030, S5031, S5032

Summary of Keypad Main User Commands

WLS900 Wireless Security System. Table of Contents. Your installing company is, Name: Address: Phone: Your monitoring station is, Name: Phone:

GV2 Series Control Panels

SENTROL ZX400/ZX410. Security System Control. Programming

HILLS Series LCD Code Pad User Manual

Fire Command Center XR2500F. User s Guide

EURO 46 User Manual. For use with EURO 46 (version 9.1 or above) RINS1531-2

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

The Challenger Version 8 User Guide

How to Use Your Sentrol Security System

ADVISOR CD User Manual. Software from version: V

EURO User Manual. For use with EURO 76, MSX 162, MSX 280 software: Version 9.1 or above RINS1527-2

Fire Command Center. XR2400F User s Guide

Solution Ultima Series Operators Manual ISSUE 1.00

How to Use Your Sentrol Security System

Euro ONE. RENDER ALARMS Your security, above all else. User Manual. t: f:

DS7446KP. User Guide. Keypad

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

Digiplex LED Keypads User s Manual

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

LS800S Intruder Alarm System. Engineering Manual

Master User Guide. Premier 412/816/832. Issue 8

SECURITY SYSTEM NOTES

Installation Instructions

Wireless Keypads LKP(E)S8M Series

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

Control/Communicator Installation Manual

636 and 646 Keypads. User s Manual

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Table of Contents. Page Code

User s Information Guide R2A

Transcription:

TS700 Intruder Alarm Control Panel OPEN _ ~ A 1 2 3 B 4 5 6 C 7 8 9 D ENT 0 ESC Setting the System Ent er your pa sscode XXXX then leave the protected area. Unsetting the System Go directly to the keypad and enter your passcode XXXX. Resetting Ent er your pa sscode XXXX f ollow ed by EN T then 3. Telephone your alarm com pan y and follow th eir instruct io ns.! See User Manual A Part Set B Part Set C Part Set D B ELL TES T WALK TEST RE SET NEW CODE CHIME 24 Hr OMIT ZONE OM IT SILENT FULL S ET 1 2 3 4 5 6 7 8 9 ENT 0 ESC Starburst User Operating Instructions

Glossary Of Terms Bell Test - A facility to test the operation of the external bells, strobes and the internal sounder. Chime - An optional facility which allows detectors or door contact devices to generate a two-tone chime if activated whilst the system is unset. Digicom - (Digital Communicator) A remote signalling device fitted to the system which will transmit alarm information via the telephone line to the alarm receiving centre. Duress - A means of entering a passcode (first two digits of a passcode reversed) which will generate a silent alarm via the remote signalling device (if fitted) to the alarm receiving centre. Exit/Entry Route - The route which must be used for entering or leaving the protected premises when the system is being set or unset. Entry Time - A preset time delay to allow the user to enter the protected premises and access the remote keypad without causing an alarm. Exit Time - A preset time delay to allow the user to leave the protected premises or area when the system is being set by the timed exit method. Exit Terminator - An external push button switch used to complete the setting of the alarm system. Full set - State of the system when it is protecting all of the premises. Final Exit - The door or detector that is used for leaving and entering the premises. Log - A record of system activity (200 events) which is stored in memory. Master User - The person in overall charge of the system i.e., the person who allocates the passcodes to all other users. Night Circuit - A circuit that armed when the system is full set or part set (if programmed). Omit - To intentionally exclude the monitoring of one or more detection circuits when setting the alarm system. Part Set - The state of the system when it is protecting part of the premises. Passcode - A unique four digit code number allocated to each user by the master user which must be entered before the system can be operated. P.A.(Panic Alarm) - An emergency push button switch used to trigger an alarm. The alarm signal will also be transmitted to the alarm receiving centre if a remote signalling device is fitted. Remote Keypad - A device located away from the main control panel that is used to operate the alarm system. Reset - Action required to return the system to its normal state after an alarm. Tamper Alarm - An alarm caused by the system being physically interfered with. unset - State of the system when it is not monitoring the activity of Night circuits. Users - Those people allocated a passcode which allows them to operate the alarm system. Walk Test - A facility for testing circuits without sounding the external sounder. 24hr Circuit - A circuit that is continuously monitored.

Contents System Overview................................................ 1 Operating the System 1 Introduction................................................ 2 2 Full Setting the System........................................ 2 3 Part Setting the System (Users 1-9).............................. 2 4 Part Setting the System using Part Set codes....................... 3 5 setting with Circuits Omitted................................... 3 6 Silent setting............................................... 3 7 Setting and unsetting with a Keyswitch........................... 3 8 Unsetting.................................................. 4 9 Unsetting after an Alarm...................................... 4 10 Resetting after an Alarm...................................... 4 User Menus Quick reference....................................... 5 User menus 11 Introduction............................................... 6 12 Bell Test................................................... 6 13 Walk Test.................................................. 6 14 Change Passcode.......................................... 7 15 Enable Chime.............................................. 7 16 Omit 24hr Group........................................... 7 17 User Menu 2............................................... 7 18 View Circuits............................................... 8 19 Change Time.............................................. 8 20 Change Date.............................................. 8 21 Setup New Users............................................ 8 22 Configure Chime Circuits.................................... 9 23 Configure 24hr Omit Group.................................... 9 24 Print System Log............................................ 10 25 Configure Part Set Groups.................................... 10 26 View System Log........................................... 10 Table 1. Log and Display Codes................................... 11 Service Record................................................ 12 User Record................................................... 13 System Configuration Record..................................... 13 Circuit Designation Record................................ Back Cover System Overview The TS700 intruder alarm control system uses state of the art electronics to provide a comprehensive but flexible protection for both domestic and commercial premises. The system comprises a number of components linked to a central control unit which is concealed from view but accessible for maintenance. All system operations are carried out from one of the remote keypads (up to four may be connected). Detection devices such as door contacts or movement sensors are allocated to detection circuits which are identified on the remote keypad displays. Each alarm installation is specific to the site and its occupier, and may differ from other TS700 installations. This manual describes in detail all the functions and procedures available to the user. To avoid unnecessary operating errors please discuss the details of the system with your installation company before attempting to use it. 1

Operating the System 1. Introduction System operation can only be carried out after entering your passcode. Up to twelve passcodes can be allocated and they can only be defined by the master user (user 1). Users A, B and C can only set and unset their respective areas. Entering a passcode with the first two digits reversed will cause a Duress Alarm. Each key press is acknowledged by the keypad sounder. Pressing the [ESC] key takes the user back to the previous step in the menu. When the system is not being used the keypad display shows the current time. The ENGINEER ON SITE message is displayed after an engineer has left his menu and is cleared the next time a user passcode is entered. 2. Full Setting the System Ensure that all monitored areas are secured. Enter your passcode (users 1 to 9 only) and the display will show "FUNCTION". After five seconds the display will show how much time is left before the system is set and the sounder makes a continuous tone. Leave via the normal exit route and close the final exit door (pressing the Exit Terminator button if fitted). The system is full set when the exit sounder stops, the display will show "SET" for five seconds then reverts to showing the current time. WARNING: If an attempt is made to set the system whilst any circuits are active (such as a door being open), the display will indicate the circuits that are in fault and the internal sounder generates an interrupted tone. The fault must be cleared before the setting procedure can be completed. If the system is set by Timed Exit and the fault is still present at the end of the exit time an internal alarm will be generated. If fitted, the external strobe light will flash indicating the system has failed to set. To prevent this alarm simply re-enter your passcode before the time expires. 3. Part Setting the System (users 1 To 9) Ensure that all monitored areas are secured. Enter your passcode (users 1 to 9 only) and within 5 seconds press [A] or [B] or [C] (depending upon the part set area required). If the five seconds is exceeded the system will full set. The display shows the selected group/area that will be omitted and the sounder makes a continuous tone. If required leave via the normal exit route and close the final exit door, (pressing the Exit Terminator button if fitted). The system is part set when the exit sounder stops, the display will alternate between the group/area that is omitted and the current time. 2 22.34 This is the normal display when the system is set or unset. The time is displayed and the "dot" segment flashes ENGINEER ON-SITE Enter user passcode to clear FUNCTION User passcode entered 9999 This figure indicates the time to set in secs. 9999 indicates the system is being set by Last Exit or Exit Terminator. Any other figure is timed exit. SET The display will show set for 5 seconds, then revert to only displaying the time. FUNCTION User passcode entered OMIT A Omit button [A] is pressed. BC SET The display shows the group that has been omitted (A).

4. Part Setting using Part Set Codes Ensure that all monitored areas are secured. Enter your passcode, the exit sounder will make a continuous tone. If required leave via the normal exit route and close the final exit door, (pressing the Exit Terminator button if fitted). The system is part set when the exit sounder stops, the display will alternate between the group/area which has been armed and the current time. 5. Setting with Circuits Omitted It may sometimes be desirable to omit a circuit when full or part setting the system. 1. Enter your passcode (users 1-9) and press [ within 5 seconds. 2. Press 7 and the display will show the circuit number followed by its omit status. N = not omitted and Y = omitted. 3. Press 0 to change the status of the circuit and [ to confirm the change. A low tone will indicate that the circuit cannot be omitted or a high pitch multi-tone indicates that the change has been accepted. Continue with the next circuit if required. 4. Press ] to quit to user menu 1" and continue with setting by pressing 0 for full-set or A or B or C for part-set (see 2 and 3). 0015 User passcode B entered. Group/area B will set in 15 seconds. B SET Group/area B is now armed. USER 1- User menu 1" selected. CCT 01 - N Circuit 01 will not be omitted. CCT 01 - Y Press [0] to change the status. Circuit 01 will now be omitted. 6. Silent Setting The system can be full set or part set silently except for the final system set sound. Enter your passcode (users 1-9) and for full set press 8 within 5 seconds. For part set press A or B or C then press 8. Alternatively Enter your passcode (users 1-9) and press [ within 5 seconds. Press 8 and the display will show "SILENT -". Enter 0 for silent full set or A or B or C for silent part set. 7. Setting and Unsetting With a Keyswitch Operate the keyswitch (or door lock) and leave via the exit route. The system will be full set or part set when the exit sounder stops. To unset the system, operate the keyswitch (or lock) again. USER 1 - User menu 1" selected. SILENT - Press [0] for silent full set or [A] or [B] or [C] for silent part set. 3

8. Unsetting Enter the premises via the normal entry route and go directly to the keypad. Enter your passcode. The display will show OPEN and then revert to displaying the current time. The sounder will sound at entry and will stop when the system is unset. If the entry time is exceeded an internal alarm is generated and the entry timer is restarted. If at the end of the second entry timer the system has not been unset a full alarm will occur. 0023 Enter passcode before entry timer expires. OPEN System is now unset (OPEN). 9. Unsetting after an Alarm Enter the premises via the normal entry route and go directly to the keypad. Enter your passcode. The sounder will sound at entry and will stop when the passcode is entered. The display will show the circuit that caused the alarm and the system must be reset. ALARM 03 Circuit Alarm 03. 10. Resetting after an Alarm Your system is programmed as EITHER User Reset or Engineer reset, consult your installation company if you are not sure. User Reset 1. Enter your passcode. 2. Press ] within 5 seconds. 3. The display will show OPEN and then revert to the current time. Engineer Reset 1. Enter your passcode. 2. Press ] within 5 seconds. 3. The CALL ENGINEER message is displayed and the engineer must now be called to reset the system. Remote Reset 1. Enter your passcode followed by [ within 5 seconds. 2. The display will show USER 1-. 3. Press 3, the display will show a four digit "seed" code. 4. Telephone your central station or installation company and quote the seed code. They will quote you a four digit Reset code in return. 5. Enter the Reset code and press [. A low tone indicates the Reset code was either incorrect or incorrectly entered. A high tone indicates the code was accepted. 6. Press ] to return to the OPEN condition. OPEN System is now reset. CALL ENGINEER System requires an engineer to reset or Remote Reset. USER 1- User Menu 1" selected. 8302 The four digit seed code. Note: This code is only an example. 2843 The four digit Reset code entered. 4

User Menus Quick Reference 11.58 FUNCTION USER 1- The system is unset, the display shows the current time. Enter user passcode. The display shows Function. Press [ within 5 seconds to select User Menu 1". User Menu 1" selected. ] Return To Open - Abandons User Menu 1" and returns the system to the unset (OPEN) condition. 1 Bell Test - Allows the internal sounders, external sounder and strobe to be tested 2 Walk Test - Allows all detection circuits to be tested without generating an alarm. 3 Remote Reset - Reset the system by exchange of 4 digit codes. 4 Change Passcode - Change your passcode. 5 Enable Chime - Enable or disable the chime option. 6 Omit 24 Hour Group - Omit a pre-defined group of 24 Hour circuits. 7 Omit Circuits - Select circuits to be omitted before setting the system. 8 Silent set - Select silent full set or part set. 0 Full Set - Full set the system. A Part Set Group A - Part set the system with group A omitted. B Part Set Group B - Part set the system with group B omitted. C Part Set Group C - Part set the system with group C omitted. [ User Menu 2 - Select User Menu 2" (master user only). USER 2- User Menu 2" selected. 1 View Circuits - View the status of all detection circuits. 2 Change Time - Set the system clock. 3 Change Date - Set the system date. 4 Setup New Users - Setup and delete user passcodes. 5 Change Chime Circuits - Select circuits that will chime. 6 Change 24hr Group - Setup a group of 24hr circuits so that can be omitted. 7 Print System Log - Print the contents of the system log (200 events). 8 Configure Part Set Groups - Configure part set groups A, B & C. 9 View System Log - View the contents of the system log. ] User Menu 1 - Return to User Menu 1". Options 4, 5, 6, 7, 8 & 9 in "User Menu 2" are only available if programmed by the installation company. 5

User Menus 11. Introduction In addition to setting and unsetting the system, users 1-9 may carry out other operations. These are selected via two user menus, User Menu 1" is available to users 1-9 and User Menu 2" which is only available to the master user. To access User Menu 1" enter your passcode and then press [ within 5 seconds. Pressing ] returns the user to the previous position in the menu. 12. Bell test This test allows the user to test the bells, sounders and strobes. 1. Ensure that User Menu 1" is selected. 2. Press 1 to select the Bell Test option. 3. The sounders, bells and strobes will operate sequentially for 9 seconds each. 4. Testing may be stopped by pressing ] or advanced to next test by pressing [. 5. Press ] to return to the OPEN condition. 13. Walk Test This test allows the user to test the function of individual circuits without creating an alarm. As each circuit is activated its number and status are displayed and the internal sounder generates a two-tone sound. As more circuits are tested they are added in turn to a scrolling display showing the status of each tested circuit. 1. Ensure that User Menu 1" is selected. 2. Press 2 to select the Walk Test option. 3. Activate circuits in turn by opening doors with contacts and walking in front of detectors. 4. Check the display to verify which circuits have been tested. 5. On completion press ] to quit the Walk Test option. 6. Press ] to return to the OPEN condition. ON-9 Count down display for Bell Test. USER 1- Test completed. User Menu 1" selected. x NONE x Walk Test selected, but no circuits have been tested. CCT 05-A Circuit 05 is now active CCT 05-H Circuit 05 is now healthy 6

14. Change Passcode All users can change their own passcode. 1. Ensure that User Menu 1" is selected. 2. Press 4 to select the Change Passcode option. 3. Enter your new passcode and press [. 4. A high pitched multi-tone indicates that the new passcode has been accepted. A low tone indicates that the passcode is already in use and has not been accepted. Try again with a different number. 5. Press ] to return to the OPEN condition. 15. Enable Chime The enable chime option allows a user to switch the chime facility on or off. This will only affect circuits that have been programmed as chime in User Menu 2" option 5. 1. Ensure that User Menu 1" is selected. 2. Press 5 to select the Chime option. 3. Press 0 to toggle the Chime ON or OFF. 4. Press [ to accept. 16. Omit 24hr Group This option allows 24 Hour, circuits to be omitted when the system is unset so that they will not alarm if activated but will alarm if tampered with. Only the circuits programmed by the engineer or master user ( User Menu 2" option 6) will be omitted. 1. Ensure that User Menu 1" is selected. 2. Press 6 to select the 24hr Omit option. 3. The display will show CIRCUITS OMITTED. 4. Enter your passcode to reinstate the omitted circuits. ---- Waiting for new passcode. 2305 New passcode 2305 entered. Press [ENT] to accept. OFF The Chime option is off. Press [0] to change. ON The Chime option is on. CIRCUITS OMITTED 24hr circuit isolated. Enter passcode to cancel. 17. User Menu 2 (master user only) The master user may access this menu by pressing [ when User Menu 1" is selected. Options 4 to 9 are only available to the master user if programmed by the installation company. USER 2- User Menu 2 selected. 7

18. View Circuits This option allows the user to view the status of each detection circuit. The circuit status conditions are H=Healthy, A=Active, S=Shorted or T=Tamper. 2. Press 1 to select the View Circuits option. 3. Circuit status will be displayed. 4. Select circuits either by entering the number or by pressing [ to scroll through the circuits. 5. Press ] to leave this option and return to User Menu 2. 6. Press ] twice to return to the OPEN condition. 19. Change Time The system clock may be changed using 24 hour clock format. 2. Press 2 to select the Change Time option. 3. Enter the time in 24 hour notation (e.g., 1805). 4. Press [ to accept. 5. Press ] twice to return to the OPEN condition. 20. Change Date The system calendar may be changed by entering the date as four digits representing the day and month e.g., 0207 is the 2nd July. 2. Press 3 to select the Change Date option. 3. Enter the date as four digits. 4. Press [ to accept. 5. Press ] twice to return to the OPEN condition. CCT 03-H Circuit 03 is Healthy CCT 03-A Circuit 03 is Active. ---- Waiting for time entry. 1805 Time entered 1805 (6:05 pm) ---- Waiting for date entry. 0207 Date entered (02 July) 21. Setup New Users Up to 12 users can be allocated to operate the alarm system. The master user (user 1) can change all user passcodes. If a passcode is entered with the first two digits reversed, a Duress Alarm is generated. If this facility is not required ensure that the 1st and 2nd digits are the same, (e.g., 1123). If a passcode is entered with the last two digits reversed, the Access Control output is operated. If this facility is not required ensure that the 3rd and 4th digits are the same, (e.g., 1233). 8

2. Press 4 to select the Setup New Users option. 3. Enter the user number (1 to 9 or A,B,C). 4. Enter the new passcode then press [ to accept. 5. A high tone will indicate acceptance. A low tone sound will indicate that the passcode is already in use. 6. Press ] twice to return to the OPEN condition. To delete a user passcode from the system, select the user number you wish to delete at step 3, then enter your own passcode (master user) at step 4. USER - Waiting for passcode type [1] - [9] or [A] or [B] or [C]. ---- Waiting for new passcode to be entered. 5750 New passcode 5750 entered. Press [ENT] to accept. Passcode Types Master User Code (1) - This passcode allows setting and unsetting of the system and allows entry to both user menus. Standard User Codes (2-7)- These passcodes allow setting and unsetting of the system and entry to User Menu 1". Cleaner Code (8) - This passcode allows only setting of the system and entry to User Menu 1". Holiday Code (9) - This passcode allows setting and unsetting of the system and allows entry to User Menu 1". The code is erased from the system when the master user code is next used to unset the system. Part Set Code A (A) - This passcode allows the setting and unsetting of group A. Part Set Code B (B) - This passcode allows the setting and unsetting of group B. Part Set Code C (C) - This passcode allows the setting and unsetting of group C. 22. Configure Chime Circuits This option is used to select the circuits that will chime. 2. Press 5 to select the Chime Circuits option. 3. Circuits will be displayed as Y to chime or N not to chime. Change status by pressing 0 ( toggle action). 4. Press [ to accept (high tone) and go to next circuit. Circuits may be selected by number. Press ] to quit. 5. Press ] twice to return to the OPEN condition. CCT 01-N Circuit 01 will not chime. Press [0] to change. CCT 01-Y Circuit 01 will chime. Press [ENT] to accept. 23. Configure 24hr Omit Group This option allows the master user to select the 24 hour circuits that will be omitted when the 24 hour omit option is selected in User Menu 1" option 6. 2. Press 6 to select the 24Hour Omit Group option. 9

3. Circuits will be displayed as O=Omitted or A=Armed. Press 0 to change ( toggle action). 4. Press [ to accept (high note) and go to next circuit. A low tone indicates that the circuit cannot be omitted. 5. Circuits may be selected by number. Press ] to quit. 6. Press ] twice to return to the OPEN condition. CCT 02-A Circuit 02 will remain Armed. Press [0] to change. CCT 02-O Circuit 02 will be omitted. Press [ENT] to accept. 24. Print System Log A printer may be connected to produce a print-out of the last 200 system events. 2. Press 7 to select the Print Log option. 3. Enter the number of events to be printed. 4. Press [ to start printing. To stop printing select the menu again and enter 000 as the number of events to be printed. 5. Press ] twice to return to the OPEN condition. --- Enter the number of events to be printed. Press [ENT] to start. 25. Configure Part Set Groups When the system is part set certain circuits are omitted. This option allows the master user to select those circuits to be omitted when part-set A or B or C is selected. 2. Press 8 to select the Part Set Groups option. 3. Select the part-set group A or B or C. 4. Circuits will be displayed as O=Omitted or A=Armed. Press 0 to change ( toggle action). 5. Press [ to accept displayed status (high tone) and go to next circuit. Circuits may be selected by number. 6. Press ] to go to step 2 and ] again to go back to User Menu 2". 7. Press ] twice to return to the OPEN condition. 26. View System Log The time, date and nature of the last 200 events on the system may be viewed starting with the most recent event. 2. Press 9 to select the View Log option. 3. The most recent event will be displayed (see Table 1) 4. Press A to scroll backwards and C to scroll forward. P. SET - Enter part set group A, B or C. CCT 01-A Circuit 01 will remain Armed for the selected part set group. Press [0] to change. CCT 01-O Circuit 01 will be omitted for the selected part set group. Press [ENT] to accept. ALARM 01 Log event showing Circuit Alarm 01. Press [A] to scroll back or [C] to scroll forward. Press [B] to view time and date. 10

5. Press B to show the time of the event (first press), the date (second press) the time in minutes and seconds (third press) the event again (fourth press). 6. Press ] to quit. 7. Press ] twice to return to the OPEN condition. ALM SENT Action alarm (Alarm output activated) LID TAMP Lid tamper, Aux tamper or SAB tamper ACC'SS xx Access passcode (user code **entered with the last two digits reversed) DELAY xx Alarm delayed (the system is part set and circuit ** was activated) SYS OPEN OMIT REM System open (unset) Omitted circuits reinstated AUX xx Auxiliary alarm from circuit ** PA.ALM xx PA alarm from circuit ** BATT FLT Battery Fault A.C. OFF Power failure (remote power LED flashes) BELL TST Bell test operated A.C. ON Power restored ALARM xx Circuit alarm from circuit ** P.SET x Part set (area *) COMS OKcc Comms successful C.TMP xx Code tamper (from remote keypad **) COMS FLT Comms failed RE-ARME D System re-armed 24HR OM'T Circuits isolated (24 hour circuits) REM RST System reset by REMOTE CODE RESET OMIT'D xx Circuit ** omitted R.REM xx Remote Keypad ** removed or lost DATE CHG Date changed R.TMP xx Remote Keypad ** case tamper DEFLT 01 Default user code 1 to 5678 SET FAIL System failed to set DUR'SS xx Duress alarm from user code ** SITE. RST System on-site reset (LK1 open on power up) EN.ALM xx Entry alarm from circuit ** W.SET x Area * set using part set codes ENTRY xx Entry from circuit ** KEY.SW xx Part set keyswitch ** operated FIRE xx Fire alarm from circuit ** TAMP'R xx Tamper alarm from circuit ** FUSE 01 Auxiliary fuse blown TIME CHG Time changed FIRST xx First knock from circuit ** T.FAIL xx Circuit ** failed test FACT.RST Factory reset (LK1 closed on power up) TEST OFF All circuits on test removed from test FULL SET Full set UNSET x Area * unset using part set codes LINE FLT Telephone line fault USER xx User code ** entered LINE OK Telephone line restored NO EVENT No event Table 1. Event Log Codes 11

Service Record Date Engineer Action Installation Company: Address: For Service Telephone: For Remote Reset Telephone: 12

User Record User No. User Type User Name 01 Master 02 Standard 03 Standard 04 Standard 05 Standard 06 Standard 07 Standard 08 Cleaner Code 09 Holiday 10 (A) Part-set A 11 (B) Part-set B 12 (C) Part-set C System Configuration Record Entry Time: Exit Time: Bell Delay: Bell Duration: System Reset By: Engineer User Remote Reset 13

Circuit Designation Record No. Location Omit Chime A B C 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 18833 Drg No. 33:2159:00 Issue 01. Doc 04. August 98