With Magictrl, you can control MatiGard anytime & anywhere via your smartphone, even without data network.

Similar documents
D3D Wi-Fi GSM Smart Alarm System -User Manual

MOBILE CALL GSM Alarm System User s Manual

GSM RFID VOICE Alarm System

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

System. For a better understanding of this product, please read this user manual thoroughly before using it.

Intelligent Wireless GSM Alarm System

Security GSM Alarm System

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

GSM Smart Home Alarm Apparatus. [99+4 defense zones] Instruction for Use

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

It is necessary to match all peripherals with the EVOLVEO Alarmex main unit before the first use. For safety reasons, they are not factory paired.

Elderly Care Alarm System

SMART HOME SECURITY. Dual Network Communicating Alarm System with RFID INVINCIBLE. Instruction Manual. Customer Helpline

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

User Manual (LS-GSM-006)

GSM Emergency Alarm. User s Manual. For a better understanding of this porduct,please read this user manual thoroughly before using it.

WiFi GSM APP Smart Home Security System

AG HOME ALARM Quick Start Guide

1. Introduction. 2. Product overview

status AW1 Plus WiFi Alarm System User Manual

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

Contents. Contents

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

K1 SMARTHOME DIY KIT

S6 Titan Security System. Wi-Fi and 3G GSM

SA 2650 Kit User Manual

GSM LCD Touch Keypad Wireless Intelligent Alarm System. User s manual

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

Wireless Alarm system s manual

IQ PANEL USER GUIDE SMARTHOME.

PiSector GSM Cellular Wireless Alarm System

GSM PROTECT ANTI-THEFT ALARM WITH GPS TRACKING & MOBILE PHONE ALERTS

Content. Chapter 1 Knowing the alarm host 1.1 Features 1.2 Technical Parameters 1.3 Packing List 1.4 Knowing the alarm host

EM8710 GSM Alarm System Starter Kit

HomeSecure HS-BASIC-V2 Installation Manual: Table of Contents

WiFi + PSTN. Smart Home Alarm System

S3 Sim Secual Alarm system with GSM transmitter

2G & 3G GSM Portable PIR Alarm


DIY Home Security Support 30 numbers wireless sensors

GSM-SD WITH CALL,SMS,MMS MANUAL

2G & 3G GSM Door Contact Alarm

K1 SMARTHOME DIY KIT

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

Quick Installation Manual LED 99-Zone Autodial Wireless Alarm System

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

Touch Keypad GSM Smart Alarm System USER MANUAL

Ontech GSM 9040/50. Reference Manual English -1 -

Vcare. User Manual. Ver WiFi - GSM- App. Smart Home Security System

CONTENTS. (User s Manual)

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

GSM House Alarm System. User Manual. Ver 1.20 Date Issued:

abode Web app Functionality

GSM-SMS-APP Smart Touch Alarm System

Smart Security, Always Connected

GSM Alarm System. S120 User Manual. Ver 1.00 Date Issued:

Contents. Glossary

The complete wirefree security alarm solution

Q3200 Smart Home Alarm. Kit Content and Installation Guide


Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

WIFI/PSTN Alarm System Instruction ENKLOV-W1

CPVan Home Alarm Starter Kit

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

2G & 3G GSM Wireless Beam Alarm

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS

Auto Dialer. Manual E-921APQ E-921GPQ

NextGen Home Security. Quick Reference Guide

JA-63 Profi User manual

Cellular + Wi-Fi Smart Security System

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright

Alarm System SECURE AS 302

Wi-Fi/ GSM SmartCam Alarm System

BURGLAR ALARM PANEL BS-468

3 User s settings. 3.3 Internal clock setting

Q3000 Smart Home Alarm. Kit Content and Installation Guide

GSM Senior Guarder GSM SOS Call System GSM Elderly Guarder

S4 Combo Secual / S4 Combo Vid Secual GSM and Landline Alarm System

IP & SMS Alarm Communicator

EURO 46 V10 User Manual

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

RINS App User Guide. Connect to your home or business from anywhere in the world.

S3b Sim Secual / S3b Sim Vid Secual GSM Alarm System

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

GSM 3G AUTO DIALLER PLUS


Wi-Fi/ GSM SmartCam Alarm System

X64 Wireless Training

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

U ser's Guide PC6010

SA 2700 Kit User Manual

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

1. User features of the GSM dialer

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Transcription:

MatiGard User Guide

02

Menu Feature-------------------------------------------------------------- 05 Overviews---------------------------------------------------------- 07 Read Before Using----------------------------------------------- 11 Using MatiGard ------------------------------------------------- 15 Using Magictrl -------------------------------------------------- 18 Installing & Using The Accessories--------------------------- 34 Appendix I: Technical Parameters --------------------------- 39 Appendix II: FAQ------------------------------------------------- 40 03

04

Features Professional & Safety With Magictrl, you can control MatiGard anytime & anywhere via your smartphone, even without data network. MatiGard is designed for safety from hardware. All commands are encrypted with private protocols which are protected by IPR laws All accesses to MatiGard needs to pass the identity authorization. Only the administrators can operate system setting. Customizable zones with anti-false algorithms, prevent the false alarm due to the pets or other animal, etc. With arming timer, 6 automatic arming can be operated everyday. With motoring, the authorized users can listen to the surrounding voices Easy & Nice Easy way to pair your sensors to MatiGard, up to 99 sensors; Identify your remote controllers, users can receive SMS to tell who is pressing down and what the button is. Customizable zone name and zone notifications SMS. Telling where it is when something happens in your zones; SimCard balance checking and SMS forwarding. Users can check the account of MatiGard anytime, and forward the SMS from particular number to your smartphone; 05

Features SMS notify when AC Power OFF.; SMS notify when arm/disarm successes; Wide LCD display for users to set and query easily; Inner speaker s volume can be adjusted from 1-4 Powerful With high performance chargeable battery & LPB technology, MatiGard can last more than 24 hours when AC Power OFF; Dual network for GSM & PSTN. (Only in GP model); Support more than 16 SMS programable wireless zone With electronic switch, users can using that to control light or TV, air conditioner remotely via Magictrl ; Save more than 70 logs & events.(dcc can query all, Magictrl can query the latest 12 of them); Customizable alarm voice. After recording, it will be played on the emergency call triggered by alarm; Inform any error in PSTN like disconnect or signal error. (Only in GP model) 06

Overviews Front View Power Light Inner Speaker Arming Light Arming Light Home Arming Light (Image-1) Away arm Home Arm Menu Disarm SOS # or CANCEL (in editing mode) * or DELETE (in editing mode) Microphone, monitor surrounding sounds USB outlet 07

Overviews Back View Power Switch Power Outlet Speaker Outlet PSTN IN Sim Card Slot PSTN OUT Anti-moving Switch Fixed Support Battery Pack Cable Slot (Image-2) 08

Overviews External Plug-in Board A1 A0 A2 Wired Sensor Wired Sensor (Image-3) 09

Overviews How to check system status? 1. By Icons On LCD Display Normal ON: Sim Card Detected Flash: Sim Card Error GSM Signal Strength Flashing when logs unread exists. Battery Life electric quantity for back up battery System Alarming 2. By TOP Lights Alarm Now Alarmed Home Arming Arming Delay Arming Disarmed 2-Alarm Light ON 2-Alarm Light Flash Per Second 4-Home Arm Light ON 3-Arm Light ON 3-Arm Light Flash Per Second Arm Light OFF 10

Read Before Using Normal Items Arming Status There are 4 arming status, which can be switched by Magictrl, remote controllers or panel. ARM HOME ARM DISARM SOS ARM ARM means all sensors are working on detecting anything unusual. System will alarm when any sensor get triggered. Turn to ARM by: 1. Press ARM button in Magictrl. 2. Press ARM button in remote controller. 3. Press ARM button in panel TIPS: Press and hold the ARM button in panel can use delay arm function temporary. *Delay Arm means the system will wait a few seconds before turn into arm status. Allows you to leave the house without trigger any alarm. Once it has been set, all arm button will work on delay arm mode 11

Read Before Using HOME ARM HOME ARM means MatiGard will ignore some zones trigger signals while keeping sensitive for some others'. It s especially useful when some users want not to be disturbed at home by shutdown the living areas sensors but leaving those sensors surrounding the house working. When using HOME ARM, those sensors wants to shutdown when at home need their zones to be set in SILENT(AT HOME) mode Turn to HOME ARM by: 1. Press HOME ARM button in Magictrl. 2. Press HOME ARM button in remote controller. 3. Press and hold the HOME ARM button in panel DISARM DISARM means cancel arm or home arm status. After that, MatiGard will not alarm, even the zones get triggered(expect those on URGENT mode). Pressing SOS will trigger alarm even in DISARM. 1. Press DISARM in Matictrl 2. Press DISARM in remote controller 3. Press administrator password + DISARM button on panel 12 SOS SOS means alarm immediately.

Read Before Using Zone And Zone Mode Zone is the working area of 1 or more sensors. In MatiGard, one zone is represented by ZONE 01,02,etc. For your convenience, please assign zones by your room sections, like ZONE 01 is assigned to living room and ZONE 02 is assigned to bedroom. One MatiGard owned more than 30 programable wireless zones. Each zone can be paired to 1 or more sensors. Users can choose zone numbers freely during the pairing process. Each zone can be set to different zone modes. Which stands for different alarm strategies. By using zone modes, MatiGard can provide security services more user-friendly. IMMEDIATE: Alarm when in ARM or HOME ARM status, but not in DISARM status when sensors get triggered. URGENT: Alarm when in ARM, HOME ARM or DISARM once the sensors get triggered. Usually use when zone pairs to smoke detector, gas leaking detector, SOS button. SILENT(AT HOME): Alarm when in ARM status and be disable when in HOME ARM or DISARM status. DOOR BELL: Never alarm, be specific to pairing to wireless doorbell. (Zone must in one of those 4 modes above) 13

Read Before Using INFORMING: Sound DINGDONG when in DISARM status if sensors get triggered. Usually use to pair to door sensor. ANTI-FALSE: Alarm only when 2 or more sensors in the same zone get triggered when in ARM or HOME ARM status. Usually using it to pair to PIR sensor. By using ANTI-FALSE, we can reduce false alarm caused by temperature or environment. (Zone can be add in 2 more modes above) We ships MatiGard with preset zone modes. ZONE 01 with door detector is in IMMEDIATE mode. ZONE 02 and ZONE 03 pair to 2 PIR sensors are in SILENT(AT HOME) mode. You can change zone mode in Magictrl. 14

Using MatiGard For your convenient, please install MatiGard properly. Usually, setting in the center of the guarding place would be helpful to receive all the RF signals. Keep away from mega metal objects or those appliances with high frequency interference, also the reinforced concrete wall or the fire doors. 1. Sim Card Installation Turn to the back side and insert the sim card into the slot (-image1). *Your sim card should be available for MatiGard to send and receive messages via SMS. 2. Power ON Power outlet is next to the SIM slot, connect it to the power supply with the cable. Turn on MatiGard (-image1), after the beeping sound the LCD display will show characters like 500ms. Then the system will check sim card status. It will finish initialization when date and time are shown on the LCD display(-image2). Now you can move to the next. (Image-1) (Image-2) 15

Using MatiGard 3. Record Voice Message 4. Make a call via MatiGard On MatiGard panel, press for 2 sec, dial your cellphone No., press to make a call. Press again to finish the phone call. 5. When alarm goes off When alarm is triggered, MatiGard will run siren and SMS to the pointed contacts, after that, it will make the emergency call to all the contacts recurrently. When one contact is busy or unable to connected, MatiGard will keep calling the next until all contacts are called 3 times or some contacts answer the phone and stop this process. 16

Using MatiGard When the emergency call are answered, MatiGard will play the voice message. Users can press down the buttons below to operate the system. [4]: Siren ON [5]: Siren OFF [6]: Intercom ON/OFF [7]: Play voice message [*] Monitor(default time is 30 sec, press * again in 30 sec for continue monitoring) [#]: Exit and hangup, MatiGard will stop making emergency call. *Please remember to press # to stop emergency call when you trigger alarm when testing MatiGard. 6. Factory Reset Press 951753082# on panel to reset. All password or settings will be restored to factory default settings. During the process, all status lights will be flashing. 17

Using Magictrl Magictrl is a powerful and convenience smartphone app for using and managing MatiGard. Download it from http://bin.bz/m Now we have ios & Android versions. Initialization Initialize when first time using or adding new device. Tips: How to find my number? On MatiGard panel, press for 2 sec, dial your cellphone No., press, wait for calling in and check the No. 18 image1: Country Code & Sim Card Number

Using Magictrl image2: Password for MatiGard image3: Name & Validation Tips: Different password means different identities such as administrator or user. The user interfaces and functions are different from each other. Administrator s default password is 123456 and user s is 1234. Both can be modified by administrator. 19

Using Magictrl image4: Auth Code & Login 20

Using Magictrl Operations (as administrator) Arm Disarm Home Arm The definition of ARM/DISARM/HOME ARM is in Page11. Electronic Switch Manage devices connect to the A1-A3 slot in the external plugin board. Monitor Call MatiGard and monitor the surrounding sounds. * Please follow the voice message, some devices need password before monitoring. SOS In emergency case, all contacts will be called in order and some will receive SMS alarm. Device Setting Setting and managing the device Device Info Check device status 21

Using Magictrl Device Setting (as adminstrator) Alarm Contacts Up to 6 contacts. Get called and SMS(optional) in emergency. Zone Setting Up to 15 zones with customized name, SMS and zone mode. Remote Controller Setting Up to 10 controllers with customized name and ARM/DISARM SMS. General Setting With Arming Timer, Delay Arming, Delay Alarm, SMS Forward and Account Management, etc. 22 In this section, most of the operations need to be save and send SMS commands after setting. You will receive a SMS reply from MatiGard like Success! Commands are accepted when the setting is in effect. image1 Device Setting

Using Magictrl Alarm Contacts Reject SMS by switch OFF the Receive SMS Note: SMS notifications are divided into alarm SMS and System Notification. Only the first contact in the list will receive the system notifications, which include events like AC Power OFF, SMS Forward, MatiGard ARM/DISARM and Remote Controller ARM/DISARM. The latest two can be chosen not to be received. image1 Alarm Contact Setting 23

Using Magictrl Zone Setting Customized name for the zone, like bedroom, living room, etc.. image1 Zone Setting 24

Using Magictrl Zone modes are the alarm strategies for one zone, check the definition in Page 13 Optional: Informing Trigger BEEP/DingDong when disarmed Anti-false Alarm by 2 or more sensors Choose one of below: Immediate Active when arming Urgent Active even when disarmed Silent Silent when home arming Doorbell Sound DingDong, not alarm image2 Zone Mode 25

Using Magictrl Remote Controller Setting 26 image1-1 Custom Name Name the controller, like Papa, Mama, Kids, Nanny, etc

Using Magictrl Set ARM/DISARM messages for controllers, like ( Out for work ), ( Back from school ), etc. image1-2 Arm SMS image1-3 Disarm SMS image1-4 SMS Demo 27

Using Magictrl General Setting - Arming Timer image1 Setting Timer With 6 timers for automatic arming by time. image2 Justify arming time here. 28

Using Magictrl Delay Arming Delay Alarm image1 Setting Delay Arming image1 Setting Delay Alarm Default time is 0 sec, means immediately active when receive arming command. Delay time is max to 90 sec. Usually used in preventing alarm before people can walk off the zone after arming. Default time is 0, means alarm immediately when sensor get triggered. Delay time is max to 90 sec. Usually used for those who lost their remote controller or phone to walk in home and disarm MatiGard in panel before the alarm goes off. 29

Using Magictrl Siren Time Speaker Volume image1 Setting Siren Time image1 Setting Volume 30 Default time is 1 min, means siren sounds for 1min when emergency. Max time is 30 mins. Minimum volume is 1, up to 4.

Using Magictrl Change Administrator Password Change User Password image1 Setting Password image1 Setting User Passwors Change the password for administrator and save it in MatiGard. Keep it to your own and use it in initialization. Change the password for user and save it in MatiGard. Please distribute it to other members in family. 31

Using Magictrl SMS Forward Re-Initialization 32 image1 Forward Setting MatiGard will forward all the SMS from this number to the first one in the Alarm Contacts. Do initialization again, click back when misoperated.

Using Magictrl Device Info Brief introducing only. System Status: Query about time, arming state, speaker volume, siren time, etc. Arming Time: Query about the gap between setting and working of arming and alarming. Informing Strategies: Query about the default contact of MatiGard and the types of SMS it ll receive. Arming Timer: Query about the schedule of automatic arming. Zone Modes: Query about the zone mode of the pointed zone. Zone Notifications: Query about the notification SMS of the pointed zone. Remote Controller s Message: Query about the ARM/DISARM SMS of the pointed controller. Contacts: List all alarm contacts, those with * means allowing to receive alarm SMS. Logs & Events: List the latest 12 logs of MatiGard, contains all the system logs (power status, etc) and ARM/DISARM events. Sim Card Balance: Fill in the carrier s service number and checking code, MatiGard will summit them to the carrier via SMS and forward the reply SMS to you. 33

Installing & Using The Accessories MatiGard is shipping with 2 remote controllers, 2 PIR sensors and 1 door/window gap sensor. We ve already pair them to different zones for the most common apartment which contains 2 bedroom and 1 door. You can easily add more sensors or remote controllers following the intro in this chapter. We recommend you to setup sensors as the picture shown below. 34

Installing & Using The Accessories Door/Window Gap Sensor Installation[demo by door] A B This sensor consists of 2 parts, the transmitter A and the magnet B. Battery is in transmitter. Process: 1. Clean the installation part of the door and frame. Stick double sided tape on the back of A & B 2. Align A & B, make sure the indicator lights of A are next to B. Put A to the door frame and B to the door. The distance between them should be less than 10mm. 3. After installation, the indicator light 1 should be flashing for 1 sec when you push the door. 4. Reinforce the sensor by using screws (for wooden doors only, A should be opened for tightening screw Pairing is required after installation, please check Page XX for more details Replace Battery: When the indicator light 2 of A is continue shining, means the battery needs replacement. 1. Open the transmitter A and replace the new 23A 12V battery. 2. Push the door to see if the indicator light 1 is on. If the sensor doesn t work, check if the battery is putting reversely or contact your reseller. 35

Installing & Using The Accessories PIR Sensor Installation 10-30 o 110 o 8-12m 2.2m 36

Installing & Using The Accessories Remote Controller Overview Press button to change the system arming status. Replace Battery: If no indicate light on when pressing button, you should change the battery. Please loose 3 screws in the back to remove the cover, then change the battery. 37

Installing & Using The Accessories The Pairing, Deleting And Checking For Sensors & Remote Controllers Pairing means to make connection between accessories and MatiGard. One sensor can only pair to one zone, while one zone can pair with amount of sensors. One MatiGard can pair with amount of remote controllers, and vice versa. Turn on and trigger the sensor, the LCD display should show zone number and serial number of the sensor. If there s no zone number on the display, you need to re-pair the sensor. Tips: If the pairing fails or the sensor pairs to a wrong zone, you can re-pair it again. MatiGard only keep the latest pairing state. Door gap sensor is in zone 01. 2 PIR sensors are in zone 02 & 03. 2 remote controllers are paired with name RC01 & 02. New sensor or remote controller needs pairing before working. Sensor Pairing Press 1# on the panel, wait for the BEEP sound, press zone number to pair to, press # again Turn on and trigger the sensor, wait for the voice prompts. Sensor Deleting Press 1* on the panel, wait for the BEEP sound to delete all sensors. Sensor Checking Press 3# on the panel, wait for the BEEP sound Controller Pairing Press 2# on the panel, wait for the BEEP sound Press any button on the remote controller, wait for the voice prompts. Controller Deleting Press 2* on the panel, wait for the BEEP sound to delete all controllers. Controller Checking Press 3# on the panel, wait for the BEEP sound Press any button on the remote controller, the LCD display should show like RC XX and serial number of the sensor. If there s no RC XX on the display, you need to re-pair the controller. 38

Appendix I: Technical Parameters Control Panel Standby current: 20mA Alarm current: 500mA Power supply: 12V DC Working temperature: -10 C ~ +85 C GSM frequency : 850/900/1800/1900MHz quad band Receiving code: ASK Transmission Frequency ( RF): 315/433MHZ±0.5MHZ Transmission distance: 100 M wireless detectors: 99 wire detectors: 7 PIR Detector Power Supply: DC9V (inner 9V battery) Standby Current: 100 ua Transmission Current: 20mA Transmission Frequency: 315/433MHZ±0.5MHZ Transmission Distance: No obstacle 80m Detective Speed: 0.3-3m/s Detective Distance: 5-12m Detective Range: Horizontal 110 Vertical 60 Working Condition: Temperature 10 C ~+ 40 C Humidity: 90 rh Door Contact Power Supply: DC12V (inner 12V battery) Standby Current: 20 ua Transmission Current: 15mA Transmission Frequency: 315/433MHZ±0.5MHZ Transmission Distance: No obstacle 80m Internal Distance: 15 mm Working Condition: Temperature 10 C ~+ 40 C Humidity: 90% rh Remote Controls Power Supply: DC=12V~8.4(Inside A23 DC=12V dry battery) Standby Current: 0 Transmission Current: 15 ma Transmission Frequency: f=433.92±0.2 MHz Transmission Speed: T 1 second Transmission Distance: Without obstacle 80m Working Condition: Temperature -10 C~ +40 C Humidity: 90 rh 39

Appendix II: FAQ Symptoms Causes Remedies Cannot receive alarm call 1.Didn t arm the system; 2.Less than 30 seconds after arming. 3.Setup wrong phone number; 4.The two parts of door contact is installed too far from each other. 5.Didn't activate PIR or other ac- cessories; 6.Didn t pair correctly 1.Make arming; 2.Operate after 30 seconds; 3.Setup the number again according to the manual; 4.Adjust the installation place of door contact; 5.Activate PIR detector; 6. Pair again The distance of remotely control is too short and the indicator light is not strong enough 1.The battery of remote controls got rusted; 2. Lowbattery 1.Clean the rust; 2. Replace the battery with a new one Indicator light of door contact or PIR detector is always on. Low battery Replace the battery with a new one Make alarm call very slowly Too many alarm contacts Set it again according to the operation manual The control panel cannot receive RF signals Didn t pair them correctly Please pair control panel with other accessories again 40

MatiGard TM User Guide Design by Dinsafe, 2013