P2000 Security Management System Express Edition Version 3.14 SP5

Similar documents
P2000 and Metasys System Integration

P2000 and Metasys System Integration

GMS GRAPHICAL MANAGEMENT SYSTEM

Access Professional Edition. The flexible access control system that grows with your business.

Avigilon Control Center System Integration Guide

Access CONTROL. MANAGEMENT Software

OnGuard 7.2 Resolved Issues

ARCHITECTURAL AND ENGINEERING SPECIFICATION

AC2000 Security Hub Security and Event Management System

Architectural and Engineering Specification for a Security Management System. StarNet 2

The system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.

Monitoring Operator Guide. Access Control Manager Software Version

Avigilon Control Center System Integration Guide

OnGuard 7.1 Resolved Issues

Ademco Vista Alarm Panel

Access Control for. Part 3 of 4. Brought to You by. Presented by Video Security Consultants

D-Link Central Management System

Facility Commander Complete, Integrated Command and Control

Building Integration System. Your platform for customized security and safety management.

System Galaxy Quick Guide

UD-VMS510i. Surveillance Management Center

HikCentral Web Client. User Manual

Tech Data Sheet D01662GB0_Esgraf 4.1 and Configuration Server 30/2011 2/(5)

Course Catalogue. An evolution of excellence. Welcome to the UTC Fire and Security EMEA Lenel OnGuard Training Catalogue for Value Added Resellers

Total Unified Solution for Building Integration: Communications, Access Control, Video Surveillance and Fire

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

HikCentral Web Client. User Manual

Cardax System Comparison

Complexity made simple

Gallagher System Integrations

Avigilon Control Center 5 System Integration Guide

Avigilon Control Center System Integration Guide

Facility Explorer Asset Protection by Yorkland Controls Ltd. Fr

Complete Security Solution

FALCO Access Control. Product Training

Patriot Systems Limited

ACCESS CONTROL SOLUTIONS ACTEC SERIES

i-vu CCN 4.0 Owner s Guide

Ion Gateway Cellular Gateway and Wireless Sensors

X.90 Access Control System

Chapter. Configuring Genetec Omnicast. Version 4.7 SR1. Configuring Third-Party Programs. SightLogix, Inc

AIRPORTS. CARECALLER PowerfulSecuritySolutionsForSeriousSecurityNeeds

Introduction. Introduction

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION

Integrated Security Solutions

Facility Commander Wnx

Millenium Electronic Access Control Systems Networked Real-Time Access Control

Avigilon Control Center 5 System Integration Guide

Patriot Systems Limited

USER S GUIDE. AXIS Cross Line Detection

Am I safe working in this building?

The IPPS was developed on IBM-PC platform under QNX real time operating system (RTOS) and uses QNX-Windows GUI.

Simplex Panel Interface Guide

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

DATA SHEET ESS-ACS WE INDENTIFY SECURE AND INTEGRATE. IRIZ ID TECHNOLOGIES

Surveillance Solution

Net2. Total Access Control.

Honeywell Total Connect Remote Services

Using ANM Mobile CHAPTER

ONYXWORKS AND FIRSTVISION. Version 4

Synergis Master Controller 2.2 Integration Guide for Assa Abloy Aperio- Enabled Locks

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

ThermoControl 0 C - 10 C - 20 C - 30 C

Chapter. Configuring Cisco VSMS. Versions 5.1, 6.0. Configuring Third-Party Programs. SightLogix, Inc

A Smart & Integrated Security solution

Getting Started with Live Exceptions

Mobile App & Customer Web Portal. Quick Start Guide

CompleteView Alarm Client User Manual. CompleteView Version 4.6.1

University. NewVoice. San Francisco Paris Geneva Zurich Linz Mainz Shanghai Brisbane Hong Kong São Paulo Dubai

Video Analytics for Perimeter Protection

BSD Technical Standard. Division 28: Electronic Safety & Security

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

PotterNet Fire & Facility Supervising Station

CITY OF DENTON RFP FOR SECURITY CARD ACCESS CONTROL SYSTEM EXHIBIT 2 SCOPE OF WORK AND TECHNICAL SPECIFICATIONS

Aviation Solutions. Why Tyco for airports? Our systems help protect over 110 airports. Secures over 80% of UK Airports and more than 60 US Airports

Avigilon Control Center 5 System Integration Guide. with STENTOFON AlphaCom. INT-STENTOFON-C-Rev1

GE Security. Wnx. Facility Commander. Integrated security management platform for Windows. Seamless. Effective. Efficient.

Synergis Master Controller 2.2 Integration Guide for Assa Abloy IP Locks

2017/11/16 P a g e 1

Section PERIMETER SECURITY SYSTEMS

DSS. Dahua VMS Platform

SECTION ACCESS CONTROL AND SECURITY MANAGEMENT SYSTEM

Integrated security management platform for Windows. Seamless. Effective. Efficient.

Oracle Communications Performance Intelligence Center

Pro-Watch Facility Manager

Redefining Security for the Modern Facility

DVTEL DVR Interface. DigiOp DVR Interface

Avigilon Control Center System Integration Guide

Session VI Smart safety systems

WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS

Fire Operator Workstation (Fire OWS) User s Guide

"VOICE OF SECURITY: Trends In Intercom, Public Address, and Mass Notification Emergency Communications

SALES SUPPORT DOCUMENT

ZIPAMINI. Smart Home Controller. make your home smart. Control your home from anywhere in the world. find out more at

Secure Your Way of Life. Now Compa ble With. Climax Home Portal Platform. Enable a Connected Future

Vykon. Security. Integrated Access Control. Web enabled security management built on the Niagara Framework

Paradox Integration Module Settings Guide

Datasheet. Version 3.8. License Plate Recognition + Red Light Violation Detection. Datasheet LPR + RLVD Version

Transcription:

Code No. LIT-1900971 Issued February 2, 2018 P2000 Security Management System Express Edition Version 3.14 SP5 Description The Johnson Controls P2000 Security Management System (SMS) represents the latest technology in integrated security solutions. Using Microsoft Windows operating systems, operators can easily configure and use the P2000 software. An underlying Microsoft SQL Server database engine offers high performance without high overhead. The Express Edition of the P2000 SMS is designed for small installations or large buildings that have lower numbers of readers, users, and cardholders, such as smaller office buildings, warehouses, and manufacturing plants. It includes all of the standard P2000 features in addition to the following items: Up to 32 readers A single client user connection Up to 10,000 cardholders Web-Based Alarm Management Standard Features and Benefits Area Control controls the number of cardholders allowed within a specific area. Operators can monitor the area at any time to determine the current number of cardholders in a particular area, and the entry and exit of personnel or vehicles into a controlled area (for example, a room or parking structure). The system can report and display in real time the number and names of cardholders within the area at any given time. Closed Circuit Television (CCTV) Integration interfaces with approved CCTV systems to provide visual security in areas that may require real-time surveillance monitoring. The P2000 software provides on-screen controls to operate the switches, cameras, and monitors that are part of the CCTV system. Other components that are part of the CCTV system include switch alarms, macros, auxiliaries, and tours; monitor sequences; and camera patterns, Web-Based Case Management presets, and auxiliaries. You can configure your CCTV system to operate continuously or run by event actions to monitor particular events. Custom Interface Options allow external applications to interface with P2000. - Application Programming Interface (API) allows applications to execute actions in the P2000 system to lock and unlock doors, set and reset output points, acknowledge alarms, trigger P2000 host events, and more. - Enhanced MIS Interface enables the P2000 system to receive cardholder information and data requests from an external database source such as a Human Resource database. Using the MIS Interface in conjunction with an external Open Database Connectivity (ODBC)-based program, the MIS Interface can add, modify, and delete cardholders and their badges in the P2000 system according to data input from an external system. Both the external system and the P2000 system can exchange a wide range of data between the Input and Output tables, including access groups, time zones, Web-Based Geo-Located Maps with P2000 VMS Video partition data, and even pictures. Operators can query cardholder information using wildcards. Encryption secures every message to and from the controller using Advanced Encryption Standard (AES) to protect the P2000 system from unauthorized sources. P2000 Version 3.14 Encryption is implemented using Federal Information Processing Standards (FIPS) 140-2, validated, (Certificate #1336), cryptographic module, from Microsoft http://www.microsoft.com Event Triggers and Actions automatically initiate a sequence of system commands (actions) based on system events and messages (triggers). Triggers determine which conditions must be met to initiate a specific action. Guard Tour provides real-time monitoring of guard activities to verify and record that a guard has physically visited a facility within a specified time reporting an early or late arrival to a designated guard tour station. The P2000 Mobile Applications system uses readers and input points to define each guard tour station. The system allows alarm configuration to report guard tour conditions and provides a control application to start and stop tours, and monitor their progress. Hours on Site Reporting records cardholders accumulated hours present at a site. This feature is used exclusively for tracking and reporting purposes, and works by recording the cardholder's time interval between an in badging and out badging at reader terminals defined to monitor Hours on Site. Low-Level Elevator Access and Cabinet Control communicates with a variety of elevator and cabinet equipment to provide basic cardholder access. 1 of 5

Mercury Access Control Products and LifeSafety Power Panel Assemblies are now integrated with the P2000 SMS, providing added flexibility to help customers meet the needs of their site's security requirements and applications using a well known and time-tested security products manufacturer while making it easy to power, house, and store the Mercury components in a secure enclosure and in a variety of configurations. The EP Series controllers also allow customers to use the same hardware they use for access control for intrusion detection. Customers can migrate to P2000, leveraging their existing Authentic Mercury EP Series hardware from other manufacturers. A complementary license is required. For more information regarding the Mercury integration, refer to the Mercury Products Open Platform Solution Product Bulletin (LIT- 12011850). Message Filtering and Routing allows operators to transmit and receive specific messages to and from specific local or remote P2000 systems, thereby reducing network traffic by transmitting and receiving only messages that pass a filter criteria. The Remote Message Server (RMS) maintains central control over all message routing and transmits messages only to P2000 servers or workstations that the RMS assumes are able and willing to receive messages. Metasys System Integration provides complete support of the integration between the Metasys system and the P2000 system. The Metasys building management system uses webbased technology to monitor and supervise facility controls such as HVAC, lighting, and fire control system supplementary monitoring. This high-level integration enables Metasys operators to access certain key security management features of the P2000 system from the Metasys web-based user interface. This interface allows the P2000 Host and Panel objects to be visible to the Metasys user. The user can browse P2000 items, view alarms and messages, send access control commands, and create interlock events. P2000 operators can receive alarms from Metasys systems Release 6.5 and higher. Mustering allows operators to track personnel movement in the event of an emergency. When an emergency occurs, all personnel within a risk area are expected to evacuate and must present their badge at a reader away from the risk area. Real-time printed reports and online display information enable the operator to track movement of personnel out of the risk area. Operators can use the same information to direct search and rescue operations. Online Tutorial presents an overview of the P2000 system's major features and options, covering a number of system configuration, installation, and troubleshooting tips. The modular design enables navigation to tutorial topics and sub-topics through Adobe Flash presentations that provide audio narration (with matching text if desired) to guide users on how to make the most of P2000's most popular features. Security Threat Level provides a rapid method of restricting access in case of an emergency. In the event of a security breach, an authorized operator can quickly change access privileges for any or all cardholders at any or all terminal readers defined for security level control. Security threat level is not supported on all controllers. Computer-based Configuration and Monitoring Client provides a user-friendly interface for easy operation. Operators can accomplish critical system functions from the: - Alarm Monitor window to provide immediate access to the current alarm queue with maps of the alarm site. - Cardholder window to facilitate setup and maintenance of badge holders and related access parameters particular to the individual. - Real-Time List window provides a time-stamped display of local or remote transactions as they occur. 2 of 5 - Real-Time Map window to display the current status of local terminals, doors, intrusion components, intercom stations, inputs, outputs, and other defined elements on a map layout of the facility. - System Configuration window to enable operators to configure and manage controllers, readers, input points, and output points. - System Status Display window to graphically display status information of panels and associated devices configured in the system. This troubleshooting tool allows operators to quickly determine if panels and connected devices are communicating. If communications go down between the server and the devices, the system displays the known status of the devices. System Reports provide operators access to system data, such as the cardholder database, or specific system transactions or configurations. Operators can review the reports on-screen or print them. The P2000 system integrates with SAP Crystal Reports software to create custom reports. User Software Privileges enable administrators to use a combination of user accounts, menu permissions, and password controls to provide very tight restrictions on the viewing and editing of cardholder data and on the operational functions available to a particular user within the system. P2000 optionally integrates to a customer's Active Directory for user authentication. Web Access enables users to perform various P2000 tasks from any web-ready computer or tablet. Users can send requests to add, edit, or delete cardholder records; add a visitor to the P2000 system; track cardholder activity; immediately disable a cardholder record in case of an emergency; print and encode cardholder badges from a Web Access computer; and more. Web Access provides the flexibility and convenience of using a standard web browser to keep a facility s cardholder data current and perform other important security functions such as monitor, acknowledge, and remove alarms; activate or deactivate output points (for example, turn on/off lights); and lock or unlock doors. Web Access uses a single user client connection. Optional Features and Benefits Advanced Web User Interface Client (Web UI) The situational awareness features of the P2000 web-based user interface provide many of the features of a physical security information management (PSIM) solution. Web UI is divided into three main components available separately or together in the complete situational awareness suite: - Alarm Manager allows you to view and respond to all the alarms at your facility. - Case Manager lets you manage your security incident cases directly from the P2000 web user interface. P2000 alarms can be directly associated with a case and evidence, such as photos, video clips, and documents can be attached as well. And when necessary the entire case can be exported to a single PDF file. - Maps makes it easy to view and respond to alarms and events using real-world geo-located maps. A user can upload and place a site layout on a real-world map (requires an internet connection) including multi-floor buildings and multi-building campuses. A user can create interactive icons for doors, input/output points, cameras, and more. When an alarm is triggered, a user can be taken to its location with a single click, and by clicking on the alarm icon, respond. Digital Video Recorder (DVR)/Video Management System (VMS) Integration allows authorized operators to view, manage recording, and control Pan, Tilt, and Zoom (PTZ) functions of many cameras from a single P2000 workstation. Depending on the DVR/VMS system used, operators can search,

retrieve, and stream real-time or archived Audio/Video (AV) recordings from any transaction or surveillance camera and monitor alarm and events. Additionally, operators can tie P2000 event triggers and actions to live AV recordings. Leveraging the deep integration with P2000 VMS, video systems can also interface with P2000 using industry standard ONVIF profile interfaces. This type of integration allows operators to use many of the integrated features of P2000 VMS including the ability to launch live video from the advanced Web UI Alarm Manager and Maps. Refer to the P2000 Security Management System DVR/VMS Integration Catalog Page (LIT-1900974) for a list of supported video platforms. Fire Alarm Integration allows a P2000 user to monitor alarms from a Johnson Controls IFC or EU OPC Integrated fire alarm system. High Availability allows P2000 to run on multiple computers without having to re-register. This option enables high-availability and fault tolerant solutions such as Stratus everrun software to provide a fail-over installation of the P2000 system in case of system failure. It is also useful for installations in a virtual environment. Intercom Integration interfaces with Zenitel and Commend intercom systems to establish audio communication links between any two or more defined intercom stations. This interface provides P2000 applications to control and display all intercom call requests coming from defined intercom stations. The operator can select a call request from the list and connect to any single intercom station, or to a group of stations. The P2000 server retrieves messages coming from the intercom equipment and uses them for event activation and distribution to P2000 workstations for the processing of intercom history messages and alarms. Note: Intercom integrations are not currently supported by the Web UI. Intrusion Detection Integration enables operators to sense intrusion in a protected building and report it to responsible parties. This feature is accomplished with a combination of detection, control, and reporting devices such as a control panel, input devices (sensors), and output devices (bells, sirens). P2000 operators can send intrusion commands to the intrusion panel (Bosch and EU OPC Integrations) to arm and disarm areas, test inputs in a selected area, start or stop bypass on selected zones, and silence an annunciator from P2000 servers or workstations. Mobile Applications Each of the mobile applications, Alarms, Door Control, and ID Viewer, allow mobile users to perform specific functions based on their permissions from an Apple ios or Google Android mobile device on a Wi-Fi connection. - Alarms lets users on the go view and respond to alarms. Users can show all alarms or filter the list of alarms by pending or critical alarms. - Door Control lets users lock, unlock, and lock or unlock doors for a duration of time while they are away from their desks. To make the process of controlling doors even easier, Door Control lets users give doors a custom name and save frequently used doors to a favorites list. - ID Viewer lets users view the cardholder activity of a door to see who has been granted or denied access. Users can view a single door, groups of doors, or all doors. Users can also filter activity by access grants and denies. Note: Mobile applications require the P2K-SW-AEM314 option. SIA Interface to Bosch (formerly Radionics) D6600 Communications Receiver/Gateway allows receiving alarm and supervisory messages from digital dialers over analog telephone lines and communicates them to the P2000 server through an RS-232 connection. Third-Party Readers/Controllers from several manufacturers are supported through P2000 expansion options allowing additional customization, such as combination reader/controller or wireless devices to the P2000. Video Badging provides visual identification of cardholders using custom badge layouts, which operators can create quickly and easily through the graphical user interface. An operator can add multiple elements to a badge, including company logos, cardholders portraits, custom text, bar codes, and signatures. Software Support Agreements Johnson Controls also offers a Software Support Agreement (SSA) for the P2000 Security Management System. As part of the agreement, customers receive all available updates of our P2000 Security Management Software and access to factory technical support. For more information, refer to the P2000 Software Support Agreement (SSA) Catalog Page (LIT-1900819). Ordering Information (Part 1 of 2) Product Code Description Number P2K-SW-EXP314 P2K-SW-314SP P2K-SW-AEM314 P2K-SW-CMGR314 P2K-SW-EMAP314 P2K-SW-SA314 P2K-SW-HA314 P2K-SW-VI314 P2K-SW-VID314 P2K-DV-PVMS314 P2K-DV-AMTS314 P2K-DV-AVGN314 P2K-DV-GNTEC314 P2K-DV-GSC314 P2K-DV-MILE314 P2K-P-ASSA314 P2K-P-EDGE314 P2K-P-MERC314 P2K-P-STN314 P2K-IA-BOSCH314 Base P2000 system that supports a single concurrent user connection using a thin or thick client. Includes all of the standard P2000 features. In addition, provides support for the following: Metasys Integration, Elevator Control, Cabinet Control, Guard Tour, High Availability, Message Filtering, Intercom, and P2000 Workstations. Also supports 10,000 cardholders. P2000 Service Pack Upgrade Web UI and mobile alarm and event management Web UI case management Web UI enhanced geo-location mapping application Enables all three browser based and mobile P2000 applications P2000 High Availability option Allows P2000 to run on multiple computers without having to re-register. P2000 Video Badging license. Package includes license certificate. No additional hardware or software is supplied with this option (the P2000 Installation DVD contains the video badging workstation software). One license required per P2000 video imaging station. P2000 Video Viewer third party integration P2000 VMS integration Aimetis Symphony integration Avigilon Control Center integration Genetec Ominicast integration option Genetec Security Center integration option Milestone XProtect integration option Assa Abloy IP controller interface (8 readers) HID Edge and Edge EVO reader/controller interface (8 readers) P2000 Mercury panel interface option Stanley OSI OMNILOCK and Wi-Q wireless reader interface (8 readers) Bosch Intrusion interface (1 panel) 3 of 5

Ordering Information (Part 2 of 2) Description Product Code Number (Continued) P2K-IA-GE314 P2K-FA-IFC314 P2K-FA-NOTE314 P2K-CS-SIA314 P2K-INT-CMD314 P2K-INT-ZEN314 Aritech intrusion interface (Europe only) IFC fire alarm interface Notifier interface (1 connection - Europe only) SIA interface to Bosch D6600 Commend Intercom interface Zenitel intercom interface P2000 Edition Feature Comparison Feature Corporate Edition Professional Edition Express Edition Workstations 5 (40 maximum) 5 1 Readers 2048 128 32 Cardholders 25,000 (10,000,000 maximum) 25,000 10,000 Real-Time Monitoring Hours on Site Reporting Enhanced MIS Interface Security Threat Level Area Control Mustering Guard Tour Cabinet Control High Availability Video Badging 5 1 Web UI and Mobile Applications Third-Party Controllers CCTV Integration DVR/VMS Integration 1 Type 1 Type Metasys Integration 1 1 IFC Fire Integration Notifier EU Fire Integration Alphacom Zenitel Intercom Integration Commend Intercom Integration 1 1 Aritech EU Intrusion Integration Bosch Intrusion Integration 10 5 Bosch D6600 Alarm Panel Integration Elevator Low-Level Interfaces Elevator High-Level Interfaces Database Partitioning Separate Database Server Archive Report Server Remote Server Connections Enterprise Configuration Option (Regional site) FDA Record Change Tracking 4 of 5

P2000 Express Edition Technical Specifications Related Documentation Document Title P2000 Requirements Server Operating Systems 1 Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2, Windows Server 2016, Windows 10 Pro and Enterprise (64-bit) Workstation Operating Systems 64-bit only: Windows 7 (Professional, Ultimate, and Enterprise), Windows 8.1 (Pro and Enterprise), Windows 10 Pro Database Engine 1 64-bit only: SQL Server 2008 R2 and SQL Server 2012 Express or SQL Server 2008 R2 SP1, SQL Server 2012, SQL Server 2012 R2, and SQL Server 2014 Standard or greater Number of Seats Supported 1 Number of Readers Supported 32 Number of Badging Stations Supported 1 Number of Cardholders Supported 10,000 Panel Types Supported CK721-A Version 3.0 or greater RDR2S-A/I8O4 Version PS-217F or greater RDR8S/I32O16 Version PS-218B CKM-EPXXXX and Authentic Mercury EPXXXX Versions 1.18.7, 1.19, and 1.22 Schlage PIM400-1501 Versions 1.18.7, 1.19, and 1.22 S321-IP Versions 2.5 to 2.10.3 or greater Stanley OSI & Wi-Q (Version 3.00.38, Portal Firmware Version 3.0.17.155, and Reader Version 3.00.039) 2 HID Edge Version 2.2.7.568 2 HID Edge EVO Version 3.5.2 2 Assa Abloy DSR Version 7.0.5 with First Generation Lock Firmware Version N14 and Second Generation Lock Firmware Version P04 V2447 1. For supported operating system and database engine combinations, refer to the P2000 Software Installation Manual (24-10832-151). 2. Not currently supported by the advanced Web UI. Document Number P2000 Database Table Definitions Part No. 24-10832-54 P2000 DVR/VMS Integration Option Manual Part No. 24-10832-62 P2000 Integrated Video Imaging with EPI Builder Manual Part No. 24-10832-97 P2000 Integrated Video Imaging with ID Server Manual Part No. 24-10832-100 P2000 Metasys System Integration Manual Part No. 24-10832-119 P2000 MIS Interface Configuration Manual Part No. 24-10832-127 P2000 Quick Reference Guide Part No. 24-10832-135 P2000 Software Installation Manual Part No. 24-10832-151 P2000 Software User Manual Part No. 24-10832-194 P2000 Web Access Manual Part No. 24-10832-208 P2000 Web UI Installation Guide Part No. 24-10832-216 P2000 Web UI User Guide Part No. 24-10832-224 P2000 XML-RPC Application Programming Interface Manual Part No. 24-10832-143 P2000 DVR/VMS Integration Catalog Page LIT-1900974 P2000 Third-Party IP Reader/Controller Integration Catalog Page LIT-1900975 P2000 Intercom Interface Option Catalog Page LIT-1900976 P2000 Bosch Intrusion and D6600 Receiver/Controller Interfaces Catalog Page LIT-1900979 P2000 Video Badging Option Catalog Page LIT-1900984 P2000 High Availability Option Catalog Page LIT-1900985 P2000 Advanced Web User Interface and Mobile Applications Catalog Page LIT-1900986 P2000 Integrations for Europe Catalog Page LIT-1900987 P2000 Intelligent Fire Control (IFC) Fire Alarm Panel Interface LIT-1900988 What's New (At a Glance) for P2000 Version 3.14 with SP3 LIT-12012139 P2000 Bosch Intrusion Interface Product Bulletin LIT-12012140 P2000 and Metasys System Integration Product Bulletin LIT-12012141 P2000 Commend Intercom Interface Option Product Bulletin LIT-12012142 P2000 Third-Party Reader/Controller Integration Product Bulletin LIT-12012143 P2000 Software Release Notes LIT-12012375 5 of 5