Alarms for the Cisco ISA 3000

Similar documents
Configuring and Monitoring Alarm

Monitor Alarms and Events

SimpleComTools, LLC 1

Power Management and Environmental Monitoring

Monitor Alarms and Events

Setting up and Managing Alarms in McAfee ESM 10.x

Contact Product Manager, with details of the application.

Alarm module for leak detection with webserver

fmap Log / Troubleshooting Manual Release 8.0 Issue 1

Alarm Monitoring and Management

Manage Alarms. Before You Begin CHAPTER

IndigoVision. GAI-Tronics Integration Module. Administrator's Guide

Managing Network Alarms and Events

Alarm Monitoring and Management

Simplex Panel Interface Guide

FCD-wire Contents. List of Figures

RAy SNMP. Application notes.

Manage Alarms. Before You Begin CHAPTER

OpenDevice Events Guide

Alarm Monitoring and Management

Manage Alarms. Before You Begin CHAPTER

Making the Most of Alarms

Alarm Monitoring and Management

Alarm setup and definitions in Cisco Unified Serviceability

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

Manage Alarms. Before You Begin CHAPTER

Getting Started with Live Exceptions

QS941A Controller User Interface

Managing Network Alarms and Events

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

SMS GSM Alarm Messenger

Front page TBA from Marketing. Network and Device Monitoring. Starter Kit

FortiNAC. Lightspeed Single Sign-On Integration. Version: 8.x Date: 8/29/2018. Rev: B

CPS3200U Technical Support Guide

Innovative Circuit Technology Ltd.

Innovative Circuit Technology Ltd.

Configuring Thresholds

Instruction Manual Environmental Monitoring Unit with Output Relay

Batt-Safe Battery String Monitoring System

CBI-064. User Manual. Caddx to KNX-BUS Interface

RADview-EMS/TDM. Element Management System for TDM Applications Optimux RAD Data Communications Publication 07/04

Trident User s Manual

Integration Test Plan

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

Inactivity Alert Sensor

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel

EL-OEM-3 OEM Packaged Voltage Data Logger

FieldServer FS Secutron

CAN unit for Analog Sensors

UAS 7000 Local Management

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

DVTEL DVR Interface. DigiOp DVR Interface

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

Bosch TCU Integration Module Administrator's Guide

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

IndigoVision Alarm Panel. User Guide

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

MiNi Server environment MoNitoriNg SySteM

Using the Dome On/Off Plug-In Switch with SmartThings. Table of Contents

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

Manual# User s Manual. DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3

Typical applications include the vibration detector. Detection of vibrations and shocks

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

User Manual. Dryer Controller M720

[ [ ADMIN PANEL USER GUIDE

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

X64 Wireless Training

LineGuard 2300 Program User Manual (FloBoss 107)

Version 1.03 January-2002 USER S MANUAL

Installation Manual GalaXy G2 / G3 / GD. o Settings GalaXy o Linking with iprotect o Keymap

Synergis Master Controller 2.2 Integration Guide for Assa Abloy IP Locks

SENSAPHONE 901 Tryens Road Aston, PA PH:

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

Dryer Controller M720

ICT180S-12I INTELLIGENT MODEL (SERIES 2)

MultiSite Manager. Setup Guide

Manual GPRS Data Logger PCE-GPRS 2

Quick Reference Guide

I-HUB Chassis. Operation Manual

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

TELSEC MINI PRO User Guide

Ion Gateway Cellular Gateway and Wireless Sensors

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

Outdoor Temperature Sensor

FS Mircom FX2000 Fire Alarm Panel

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Lighting Xpert Insight User Manual

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

SensorHawk 4 PoE. For more information please visit us at or call us at 1 (800)

MODBUS MESSAGING to the S5 BATTERY VALIDATION SYSTEM

Monitoring Solutions

Moxa Proactive Monitoring User s Manual

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

P2000 and Metasys System Integration

Multistate Alarm. Introduction

Using the Dome Leak Sensor with SmartThings. Table of Contents

Recording Server PRELOADED

ELT-KLED EliteSuite LED Keypad Installation Manual

Transcription:

About s This chapter gives an overview of the alarm system in the ISA 3000, and also describes how to configure and monitor alarms. About s, on page 1 Defaults for s, on page 3 Configure s, on page 3 Monitoring s, on page 6 History for s, on page 8 You can configure the ISA 3000 to issue alarms for a variety of conditions. If any conditions do not match the configured settings, the system triggers an alarm, which is reported by way of LEDs, syslog messages, SNMP traps, and through external devices connected to the alarm output interface. By default, triggered alarms issue syslog messages only. You can configure the alarm system to monitor the following: Power supply. Primary and secondary temperature sensors. input interfaces. The ISA 3000 has internal sensors plus two alarm input interfaces and one alarm output interface. You can connect external sensors, such as door sensors, to the alarm inputs. You can connect external alarm devices, such as buzzers or lights, to the alarm output interface. The alarm output interface is a relay mechanism. Depending on the alarm conditions, the relay is either energized or de-energized. When it is energized, any device connected to the interface is activated. A de-energized relay results in the inactive state of any connected devices. The relay remains in an energized state as long as alarms are triggered. For information about connecting external sensors and the alarm relay, see Cisco ISA 3000 Industrial Security Appliance Hardware Installation Guide. 1

Input Interfaces Input Interfaces You can connect the alarm input interfaces (or contacts) to external sensors, such as one that detects if a door is open. Each alarm input interface has a corresponding LED. These LEDs convey the alarm status of each alarm input. You can configure the trigger and severity for each alarm input. In addition to the LED, you can configure the contact to trigger the output relay (to activate an external alarm), to send syslog messages, and to send SNMP traps. The following table explains the statuses of the LEDs in response to alarm conditions for the alarm inputs. It also explains the behavior for the output relay, syslog messages, and SNMP traps, if you enable these responses to the alarm input. Status LED Output SNMP Trap not configured Off No alarms triggered Solid green activated Minor alarmsolid red energized generated SNMP trap sent Major alarmflashing red end Solid green de-energized generated Output Interface You can connect an external alarm, such as a buzzer or light, to the alarm output interface. The alarm output interface functions as a relay and also has a corresponding LED, which conveys the alarm status of an external sensor connected to the input interface, and internal sensors such as the dual power supply and temperature sensors. You configure which alarms should activate the output relay, if any. The following table explains the statuses of the LEDs and output relay in response to alarm conditions. It also explains the behavior for syslog messages, and SNMP traps, if you enable these responses to the alarm. Status LED Output SNMP Trap not configured Off No alarms triggered Solid green activated Solid red energized generated SNMP trap sent end Solid green de-energized generated 2

Defaults for s Defaults for s The following table specifies the defaults for alarm input interfaces (contacts), redundant power supply, and temperature. Trigger Severity SNMP Trap Output Message Contact 1 Closed State Minor Contact 2 Closed State Minor Redundant Power Supply (when enabled) Temperature for the primary temperature alarm (default values of 92 C and -40 C for the high and low thresholds respectively) for primary temperature alarm for primary temperature alarm for primary temperature alarm for the secondary alarm. Configure s To configure alarms for the ISA 3000, perform the following steps. Procedure Step 1 Step 2 Configure severity for one or all alarm contacts. alarm contact {contact_number all} severity {major minor none} ciscoasa(config)# alarm contact 1 severity major Enter a contact number (1 or 2) or enter all to configure all alarms. Enter major, minor or none as the severity. The default is minor. Configure triggers for one or all alarm contacts. alarm contact {contact_number all} trigger {closed open} 3

Configure s Specifying open will trigger an alarm when a contact which is normally closed (normal electrical connectivity), is open, or when current stops flowing. Specifying closed will trigger an alarm when the contact which is normally open (no electrical connectivity), is closed, or when current starts flowing. For example, if a door sensor is connected to an alarm input, its normally open state has no electrical current flowing through the contacts. If the door is opened, electrical current flows through the contacts, activating the alarm. ciscoasa(config)# alarm contact 1 trigger open Enter a contact number (1 or 2) or enter all to configure all alarms. Enter open or closed to specify the trigger. The default is closed. Step 3 Enable relay, system logger and SNMP traps for alarm contacts. When the relay is enabled, and an alarm condition arises, the relay is energized and the device attached to the relay is activated. When the relay is energized, the alarm out LED glows solid red. Enable relay for the input alarm. alarm facility input-alarm contact_number relay ciscoasa(config)# alarm facility input-alarm 1 relay Enter a contact number (1 or 2). By default, relay for alarm inputs is disabled. Enable system logger. alarm facility input-alarm contact_number syslog ciscoasa(config)# alarm facility input-alarm 1 syslog Enter a contact number (1 or 2). Enable SNMP traps. alarm facility input-alarm contact_number notifies ciscoasa(config)# alarm facility input-alarm 1 notifies Enter a contact number (1 or 2). Step 4 (Optional) Specify a description for input alarm contacts. alarm contact contact_number description string ciscoasa(config)# alarm contact 1 description Door_Open The contact_number specifies the alarm contact for which the description is configured. The description may be up to 80 alphanumeric characters long and will be included in syslog messages. To set the default description to the corresponding contact number use the no alarm contact contact_number description command. 4

Configure s Step 5 Configure power supply alarms. Note Redundant power supply has to be enabled for the power supply alarms to work. See the following commands for configuring power supply alarms: power-supply dual This command enables dual power supply. alarm facility power-supply rps disable This command disables the power supply alarm. In its default state, this alarm is disabled. If the alarm is enabled, use this command to disable it. alarm facility power-supply rps notifies This command sends power supply alarm traps to an SNMP server. alarm facility power-supply rps relay This command associates the power supply alarm to the relay. alarm facility power-supply rps syslog This command sends power supply alarm traps to a syslog server. Step 6 Configure temperature thresholds. alarm facility temperature {primary secondary}{high low} threshold ciscoasa(config)# alarm facility temperature primary high 90 ciscoasa(config)# alarm facility temperature primary low 40 ciscoasa(config)# alarm facility temperature secondary high 85 ciscoasa(config)# alarm facility temperature primary low 35 For the primary temperature alarm, valid threshold values range from 40 C to 92 C. For the secondary temperature alarm, valid threshold values range from 35 C to 85 C. If a temperature threshold is configured for the secondary alarm, only the secondary alarm will be enabled. Use the no form of each command to disable or revert to default values. Using the no form of the commands for the primary alarm will not disable the alarm and will revert to the default values of 92 C for the high threshold, and 40 C for the low threshold. Using the no form of the command for the secondary alarm will disable it. Step 7 Enable SNMP traps, relay and system logger for temperature alarms. See the following commands for enabling relay, SNMP traps, and syslogs for temperature alarms: alarm facility temperature {primary secondary} notifies This command sends primary or secondary temperature alarm traps to an SNMP server. alarm facility temperature {primary secondary} relay This command associates the primary or secondary temperature alarm to the relay. alarm facility temperature {primary secondary} syslog This command sends primary or secondary temperature alarm traps to a syslog server. 5

Monitoring s Use the no form of each command to disable relay, SNMP traps and syslogs. Monitoring s See the following commands to monitor alarms: Procedure show alarm settings This command displays all global alarm settings. ciscoasa> show alarm settings Power Supply Temperature-Primary Thresholds MAX: 92C MIN: -40C Temperature-Secondary Threshold Input- 1 Input- 2 show environment alarm-contact This command displays all external alarm settings. ciscoasa> show environment alarm-contact ALARM CONTACT 1 Status: not asserted Description: external alarm contact 1 Severity: minor Trigger: closed ALARM CONTACT 2 Status: not asserted Description: external alarm contact 2 Severity: minor Trigger: closed show facility-alarm status [info major minor] 6

Monitoring s This command displays all alarms based on severity specified. The output displays the following information: Column Source Severity Description Description Device from which the alarm was triggered. This is usually the hostname configured on the device. Major or minor Type of alarm triggered. For example, temperature, external contact, redundant power supply etc. Energized or de-energized stamp of the triggered alarm ciscoasa> show facility-alarm status info Source Severity Description ciscoasa minor external alarm contact 1 triggered Energized 06:56:50 ciscoasa minor Temp below Secondary Threshold De-energized 06:56:49 ciscoasa major Redundant pwr missing or failed De-energized 07:00:19 ciscoasa major Redundant pwr missing or failed De-energized 07:00:19 ciscoasa> show facility-alarm status major Source Severity Description ciscoasa major Redundant pwr missing or failed De-energized 07:00:19 ciscoasa major Redundant pwr missing or failed De-energized 07:00:19 ciscoasa> show facility-alarm status minor Source Severity Description ciscoasa minor external alarm contact 1 triggered Energized 06:56:50 ciscoasa minor Temp below Secondary Threshold De-energized 06:56:49 UTC Mon Sep 22 2014 show facility-alarm relay This command displays all relays in energized state. ciscoasa> show facility-alarm relay Source Severity Description ciscoasa minor external alarm contact 1 triggered Energized 06:56:50 7

History for s History for s Feature Name ports support for the ISA 3000 Platform Releases 9.7(1) Description The ISA 3000 now supports two alarm input pins and one alarm out pin, with LEDs to convey alarms statuses. External sensors can be connected to the alarm inputs. An external hardware relay can be connected to the alarm out pin. You can configure descriptions of external alarms. You can also specify the severity and trigger, for external and internal alarms. All alarms can be configured for relay, monitoring and logging. We introduced the following commands: alarm contact description, alarm contact severity, alarm contact trigger, alarm facility input-alarm, alarm facility power-supply rps, alarm facility temperature, alarm facility temperature high, alarm facility temperature low, clear configure alarm, clear facility-alarm output, show alarm settings, show environment alarm-contact. We introduced the following screens: Configuration > Device Management > Port > Contact Configuration > Device Management > Port > Redundant Power Supply Configuration > Device Management > Port > Temperature Monitoring > Properties > > Settings Monitoring > Properties > > Contact Monitoring > Properties > > Facility Status 8