Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Similar documents
Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100U4PSBA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080D3PSBA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 60,000 BTUH S9V2B060D3PSBA TAG:

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Downflow/Horizontal Right Induced Draft Gas Furnace

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Upflow/Horizontal Condensing, Gas-Fired Furnace

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XB 80 TDD-D-1 PUB. NO

Upflow/ Downflow Horizontal Right or Left Gas-Fired Furnace

Variable Speed Convertible Air Handler 5 Ton

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Variable Speed Convertible Air Handler 4 Ton

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Variable Speed Convertible Air Handler 2 1/2 Ton

Upflow/ Horizontal Left/Right, Downflow Single and 2 Stage Non-Condensing Gas Fired Furnace

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

80% and 95% furnace models feature aluminized steel heat exchangers to conduct heat quickly and increase durability.

X341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models:

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

FG7T (C and L Series)

MERIT SERIES Downflow

*DD2B060A9V3VA *DD2B080A9V3VA *DD2C100A9V5VA *DD2D120A9V5VA

TECHNICAL SPECIFICATIONS

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

PRODUCT SPECIFICATIONS 1 *UH2B080A942VA

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Submittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG:

ELITE SERIES Downflow - High Efficiency Blower Motor

Cooling Capacity CFM range

G6RC Series TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

TECHNICAL SPECIFICATIONS

RG7D 1-Stage Heat Series

Cooling Capacity CFM in. w.c. (125 Pa)

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

TECHNICAL SPECIFICATIONS

Cooling Capacity CFM in. w.c. (125 Pa)

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Wt. Lbs Model Number (BTUH) Hz

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

Comfort, Quality and Efficiency.

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

13 GEP A L P - 1 A

TECHNICAL SPECIFICATIONS

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

Cooling Capacity CFM in. w.c. (125 Pa)

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Product Data. Convertible Air Handlers 1 1/2 5Ton

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

36,000-62,000 BTUH Nominal Capacity

Submittal. Single Packaged Convertible Gas/Electric 14 SEER 4YCC4024A-SUB-1F-EN. August YCC4024A1060A TAG:

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

RGE 13 A T - 1 A

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

HIGH-EFFICIENCY FURNACES

Energy Saving. Space Saving.

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

HIGH EFFICIENCY FURNACES Built Exclusively for Manufactured Housing

TSTAT0201CW Recommended (sold separately)

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

8+* Bulletin No November 1997

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Transcription:

Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B080U3PSAA Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. February 2016 S9V2B080U3-SUB-1-EN

Outline Drawings Upfl ow Furnace B Size Cabinet 2 S9V2B080U3-SUB-1-EN

Product Specification MODEL S9V2B080U3PSAA MODEL S9V2B080U3PSAA TYPE Upflow / Horizontal Type Fired 409 Stainless Steel RATINGS (a) 1st Stage Input BTUH (ICS) 52,000 1st Stage Capacity BTUH 50,440 2nd Stage Input BTUH 80,000 2nd Stage Capacity BTUH (ICS) (b) (c) 77,600 Unfired 29 4C Stainless Steel Gauge (Fired) 20 ORIFICES Main Nat. Gas Qty. Drill Size 4-45 LP Gas Qty. Drill Size 4-56 1st Stage Temp. Rise (Min.-Max.) 30-60 GAS VALVE Redundant - Two Stage 2nd Stage Temp. Rise (Min.-Max.) 40-70 AFUE (%) 96.0 BLOWER DRIVE DIRECT Diameter Width (In.) 11 X 8 No. Used 1 Speeds (No.) Variable CFM vs. in. w.g. See Fan Performance Table Motor HP 1/2 RPM Variable Volts/Ph/Hz 120 / 1 / 60 FLA 5.7 COMBUSTION FAN Type Centrifugal Drive No. Speeds Direct - 2 Motor HP RPM 3300/2600 Volts/Ph/Hz 120 / 1 / 60 FLA 0.66 FILTER Furnished? Type recommended Hi Vel. (No.-Size-Thk.) VENT PIPE DIAMETER Min (in.) (d) (e) No High Velocity 1 16x25 1 in. 2 Round PILOT SAFETY DEVICE Type BURNERS Type 120 V SiNi Igniter Multiport Inshot Number 4 POWER CONN. V/Ph/Hz (f) 120 / 1 / 60 Ampacity (In Amps) 7.9 Max. Overcurrent Protection (Amps) 15 PIPE CONN. SIZE (in.) 1/2 DIMENSIONS H x W x D Uncrated (In.) 34 x 17-1/2 x 28 3/4 Crated (In.) 35-1/2 x 19-1/2 x 30-7/8 WEIGHT Shipping (Lbs.)/Net (Lbs.) 132/124 (a) For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. (b) Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 latest edition. (c) Based on U.S. government standard tests. (d) Refer to the Vent Length Table in the Installer's Guide. (e) All S9V2 furnace models have a vent outlet diameter that equals 2 in. (f) The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. HEAT EXCHANGER S9V2B080U3-SUB-1-EN 3

Heating and Airflow Tables S9V2B080U3PSAA Table 1. S9V2B080U3PSAA Heating Airflow S9V2B080U3PSAA Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure with Filter 1st Stage Capacity = 50,440 2nd Stage Capacity = 77,600 Heating Airflow Setting Target Airflow External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 1070 1030 990 950 910 Low 948 Temp. Rise 45 45 46 46 46 Watts 120 162 203 245 286 CFM 1109 1061 1013 965 917 Medium Low 1051 Temp. Rise 42 44 46 47 49 Heating 1st Stage Watts 143 197 252 307 361 CFM 1188 1125 1062 998 935 Medium (a) 1090 Temp. Rise 40 42 43 45 47 Watts 154 215 276 336 397 CFM 1230 1212 1193 1174 1156 High 1168 Temp. Rise 38 39 39 40 41 Watts 194 246 297 349 401 CFM 1331 1293 1256 1218 1172 Low 1200 Temp. Rise 55 56 57 58 61 Watts 221 277 333 388 436 CFM 1436 1388 1340 1263 1172 Medium Low 1330 Temp. Rise 50 52 54 56 61 Heating 2nd Stage Watts 287 347 407 421 436 CFM 1380 1380 1338 1263 1172 Medium (a) 1380 Temp. Rise 52 52 53 56 61 Watts 283 351 396 421 436 CFM 1460 1400 1338 1263 1172 High 1480 Temp. Rise 49 51 53 56 61 Watts 329 363 396 421 436 (a) Factory Setting. 4 S9V2B080U3-SUB-1-EN

Heating and Airflow Tables S9V2B080U3PSAA / S9V2B080D3PSAA Table 2. S9V2B080U3PSAA / S9V2B080D3PSAA Airflow S9V2B080U3PSAA / 9V2B080D3PSAA Furnace Airflow (CFM) and Power (Watts) vs. External Static Pressure with Filter Unit Outdoor Airflow Setting (CFM/ ton) External Static Pressure 0.1 0.3 0.5 0.7 0.9 450 CFM 900 900 900 900 900 Watts 95 141 191 245 301 420 CFM 840 840 840 840 840 Watts 80 124 172 223 277 400 CFM 800 800 800 800 800 Watts 71 114 160 210 262 2.0 Ton 370 350 CFM 740 740 740 740 740 Watts 59 99 143 191 242 CFM 700 700 700 700 700 Watts 52 91 133 180 229 330 CFM 660 660 660 660 660 Watts 46 83 124 169 218 310 CFM 620 620 620 620 620 Watts 40 75 115 159 207 290 CFM 580 580 580 580 580 Watts 35 68 107 150 197 450 CFM 1125 1125 1125 1125 1125 Watts 166 222 282 345 410 420 CFM 1050 1050 1050 1050 1050 Watts 139 192 248 308 370 400 CFM 1000 1000 1000 1000 1000 Watts 123 173 228 286 346 2.5 Ton 370 350 CFM 925 925 925 925 925 Watts 101 149 200 255 312 CFM 875 875 875 875 875 Watts 88 134 183 236 291 330 CFM 825 825 825 825 825 Watts 77 120 167 218 272 310 CFM 775 775 775 775 775 Watts 66 107 153 202 254 290 CFM 725 725 725 725 725 Watts 57 96 139 187 237 S9V2B080U3-SUB-1-EN 5

Heating and Airflow Tables Table 2. S9V2B080U3PSAA / S9V2B080D3PSAA Airflow (continued) S9V2B080U3PSAA / 9V2B080D3PSAA Furnace Airflow (CFM) and Power (Watts) vs. External Static Pressure with Filter Unit Outdoor Airflow Setting (CFM/ ton) External Static Pressure 0.1 0.3 0.5 0.7 0.9 450 CFM 1350 1350 1338 1263 1172 Watts 267 333 396 421 436 420 CFM 1260 1260 1260 1260 1172 Watts 223 285 350 419 436 400 CFM 1200 1200 1200 1200 1172 Watts 196 255 318 385 436 3.0 Ton (a) 370 CFM 1110 1110 1110 1110 1110 Watts 160 216 275 337 402 350 CFM 1050 1050 1050 1050 1050 (a) Watts 139 192 248 308 370 330 CFM 990 990 990 990 990 Watts 120 170 224 281 341 310 CFM 930 930 930 930 930 Watts 103 150 202 257 314 290 CFM 870 870 870 870 870 Watts 87 132 181 234 289 450 CFM 1460 1400 1338 1263 1172 Watts 329 363 396 421 436 420 CFM 1460 1400 1338 1263 1172 Watts 329 363 396 421 436 400 CFM 1400 1400 1338 1263 1172 Watts 294 363 396 421 436 3.5 Ton 370 350 CFM 1295 1295 1295 1263 1172 Watts 239 303 370 421 436 CFM 1225 1225 1225 1225 1172 Watts 207 267 332 399 436 330 CFM 1155 1155 1155 1155 1155 Watts 177 235 296 360 427 310 CFM 1085 1085 1085 1085 1085 Watts 151 205 264 325 388 290 CFM 1015 1015 1015 1015 1015 Watts 128 179 234 292 353 (a) Factory Setting 6 S9V2B080U3-SUB-1-EN

General Features NATURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control is a solid state device which continuously monitors for presence of flame when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide additional safety. QUICK HEATING Durable, cycle tested, heavy gauge tubular stainless steel primary heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside. BURNERS Multiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas with LP conversion kit. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains dry contacts for EAC and HUM. ENERGY EFFICIENT OPERATION Furnace is certified by the manufacturer to leak 1% or less of nominal air conditioning CFM delivered when pressurized to.5" water column with all inlets, outlets, and drains sealed. AIR DELIVERY The variable speed blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from room thermostat. SECONDARY HEAT EXCHANGER The S-Series furnace has a special type 29-4C stainless steel secondary heat exchanger to reclaim heat from flue gases which would normally be lost. STYLING Heavy gauge steel and "wrap-around" cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. Every orientation has at least two venting options. There are no knockouts on cabinet. FEATURES AND GENERAL OPERATION The S-Series furnace utilizes a Silicon Nitride Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switches. S9V2B080U3-SUB-1-EN 7

Features and Benefits 96.0% AFUE ACROSS ALL MODELS Meets utility rebates Lowers utility bills ELECTRICALLY EFFICIENT Efficient airflow design reduces electrical energy use 34 INCH TALL Lighter, easier to move and fit into tight spaces like short basements or tight closets Works great with larger, high-efficiency coils No knockouts 3 WAY MULTI-POISE / DEDICATED DOWNFLOW 9 SKU s Upflow / Horizontal Left / Horizontal Right 7 SKU s Downflow Added application flexibility and reduction in specification errors AIRFLOW At least 400 CFM/ton at 0.5 in. H 2 0 external static pressure; setup airflow options down to 290 CFM/ton REGULATORY All models are air tight; 1% or less air leakage as per ASHRAE 193 Open vestibule design provides a full 34 high open vestibule DIMENSIONS Widths are industry standard: 17.5, 21, and 24.5 Depth remains approximately 28 Cabinet will be compatible with industry standard coils, as well as, other accessories INTEGRATED FURNACE CONTROL Setup / Status / Diagnostics / Digital Display No dip switches Last six errors stored Dry contact EAC and HUM connections All Molex connections; no spade terminals Low voltage labeled above and below Rain shield over IFC keeps condensate off the control TUBULAR STAINLESS STEEL PRIMARY HEAT EXCHANGER 29 4C STAINLESS STEEL SECONDARY HEAT EXCHANGER Stainless steel is a more durable, corrosive-resistant material than aluminumized steel Integrated rail system for easy access if required Reduces or eliminates need for baffles VORTICA II BLOWER, DESIGNED EXCLUSIVELY FOR THE S-SERIES FURNACE Improved airflow efficiency Durable, easy to clean, two piece housing Single piece belly band/ motor arm assembly Blower deck has full-length rails for easy removal and replacement, regardless of poise THREE WAY MULTI-POISE (UPFLOW, HORIZONTAL LEFT AND RIGHT) PLUS DEDICATED DOWNFLOW Easier to specify Shipped ready to install (no kits required) Every model has at least two venting options When in horizontal, trap extends only about 2 Barbed fitting on trap at hose connection and on cabinet transition for hose has barbed fitting and clamps at both ends for leak resistance. Vent table improvements including longer vent lengths; 2 pipe can be used up to 100K 8 S9V2B080U3-SUB-1-EN

Notes The manufacturer optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, the manufacturer offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.irco.com. The manufacturer has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. 2016 Trane S9V2B080U3-SUB-1-EN 24 Feb 2016 Supersedes (New)