Submittal. Downflow Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080D3PSBA TAG:

Similar documents
Submittal. Downflow Two Stage Condensing Gas Fired Furnace 60,000 BTUH S9V2B060D3PSBA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100U4PSBA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Downflow/Horizontal Right Induced Draft Gas Furnace

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XB 80 TDD-D-1 PUB. NO

Upflow/ Downflow Horizontal Right or Left Gas-Fired Furnace

Upflow/ Horizontal Left/Right, Downflow Single and 2 Stage Non-Condensing Gas Fired Furnace

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

X341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models:

80% and 95% furnace models feature aluminized steel heat exchangers to conduct heat quickly and increase durability.

Product Data. Convertible Air Handlers 1 1/2 5Ton

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

Product Data. Convertible Air Handlers 1 1/2 5Ton

Variable Speed Convertible Air Handler 5 Ton

FG7T (C and L Series)

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Variable Speed Convertible Air Handler 4 Ton

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

*DD2B060A9V3VA *DD2B080A9V3VA *DD2C100A9V5VA *DD2D120A9V5VA

Variable Speed Convertible Air Handler 2 1/2 Ton

TECHNICAL SPECIFICATIONS

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

MERIT SERIES Downflow

PRODUCT SPECIFICATIONS 1 *UH2B080A942VA

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Cooling Capacity CFM in. w.c. (125 Pa)

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

Cooling Capacity CFM range

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

RG7D 1-Stage Heat Series

Comfort, Quality and Efficiency.

TECHNICAL SPECIFICATIONS

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

ELITE SERIES Downflow - High Efficiency Blower Motor

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Cooling Capacity CFM in. w.c. (125 Pa)

Wt. Lbs Model Number (BTUH) Hz

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

G6RC Series TECHNICAL SPECIFICATIONS

13 GEP A L P - 1 A

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

Cooling Capacity CFM in. w.c. (125 Pa)

Submittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG:

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

36,000-62,000 BTUH Nominal Capacity

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

Ruud Achiever Plus Series Multi-position Gas Furnaces

MULTI POSITION GAS FURNACE

MULTI POSITION GAS FURNACE

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

GMS9/GCS9 SERIES 93% AFUE

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

Multi-Position Gas Furnaces

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

Product Catalog Gas Heating Products: Indoor and Outdoor Units

RGE 13 A T - 1 A

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

Energy Saving. Space Saving.

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Transcription:

Submittal Downflow Two Stage Condensing Gas Fired Furnace 80,000 BTUH Downflow Only S9V2B080D3PSBA Note:Graphics in this document are for representation only. Actual model may differ in appearance. SAFETYWARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. March 2017 S9V2B080D3-SUB-1A-EN

Outline Drawings 2 S9V2B080D3-SUB-1A-EN

Product Specification MODEL S9V2B080D3PSBA MODEL S9V2B080D3PSBA TYPE Downflow Type Fired 409 Stainless Steel RATINGS (a) 1st Stage Input BTUH (ICS) 52,000 1st Stage Capacity BTUH 50,440 2nd Stage Input BTUH 80,000 2nd Stage Capacity BTUH (ICS) (b) (c) 77,600 Unfired 29 4C Stainless Steel Gauge (Fired) 20 ORIFICES Main Nat. Gas Qty. Drill Size 4-45 LP Gas Qty. Drill Size 4-56 1st Stage Temp. Rise (Min.-Max.) 30-60 GAS VALVE Redundant - Two Stage 2nd Stage Temp. Rise (Min.-Max.) 40-70 AFUE (%) 96.0 BLOWER DRIVE DIRECT Diameter Width (In.) 11 X 8 No. Used 1 Speeds (No.) Variable CFM vs. in. w.g. See Fan Performance Table Motor HP 1/2 RPM Variable Volts/Ph/Hz 120 / 1 / 60 FLA 5.7 COMBUSTION FAN Type Centrifugal Drive No. Speeds Direct - 2 Motor HP RPM 3300/2600 Volts/Ph/Hz 120 / 1 / 60 FLA 0.66 FILTER Furnished? Type recommended Hi Vel. (No.-Size-Thk.) VENT PIPE DIAMETER Min (in.) (d) (e) No High Velocity 2 14x20 1 in. 2 Round PILOT SAFETY DEVICE Type BURNERS Type 120 V SiNi Igniter Multiport Inshot Number 4 POWER CONN. V/Ph/Hz (f) 120 / 1 / 60 Ampacity (In Amps) 7.9 Max. Overcurrent Protection (Amps) 15 PIPE CONN. SIZE (in.) 1/2 DIMENSIONS H x W x D Uncrated (In.) 34 x 17-1/2 x 28 3/4 Crated (In.) 35-1/2 x 19-1/2 x 30-7/8 WEIGHT Shipping (Lbs.)/Net (Lbs.) 132/124 (a) For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. (b) Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3. (c) Based on U.S. government standard tests. (d) Refer to the Vent Length Table in the Installer's Guide. (e) All S9V2 furnace models have a vent outlet diameter that equals 2 in. (f) The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. HEAT EXCHANGER S9V2B080D3-SUB-1A-EN 3

Heating and Airflow Tables S9V2B080D3PSBA Table 1. S9V2B080D3PSBA Heating Airflow S9V2B080D3PSBA Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure with Filter 1st Stage Capacity = 50,440 2nd Stage Capacity = 77,600 Heating Airflow Setting Target Airflow External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 843 836 830 823 816 Low 948 Temp. Rise 56 56 57 57 58 Watts 106 158 209 260 312 CFM 949 936 924 911 898 Medium Low 1051 Temp. Rise 50 51 51 52 53 Heating 1st Stage Watts 138 195 252 309 366 CFM 981 952 922 893 864 Medium (a) 1090 Temp. Rise 48 49 51 52 54 Watts 151 210 269 328 387 CFM 1043 1031 1018 1006 993 High 1168 Temp. Rise 45 45 46 47 47 Watts 181 244 307 371 434 CFM 1087 1076 1065 1055 1044 Low 1200 Temp. Rise 66 67 68 68 68 Watts 195 255 315 376 367 CFM 1211 1168 1124 1080 1036 Medium Low 1330 Temp. Rise 59 61 64 66 69 Heating 2nd Stage Watts 268 310 352 322 363 CFM 1242 1242 1204 1137 1055 Medium (a) 1380 Temp. Rise 57 57 59 63 67 Watts 214 276 321 351 373 CFM 1314 1260 1204 1137 1055 High 1480 Temp. Rise 54 56 59 63 67 Watts 249 285 321 351 373 (a) Factory Setting. 4 S9V2B080D3-SUB-1A-EN

Heating and Airflow Tables S9V2B080U3PSBA /S9V2B080D3PSBA Table 2. S9V2B080U3PSBA/ S9V2B080D3PSBA Airflow S9V2B080U3PSBA / S9V2B080D3PSBA Furnace Airflow (CFM) and Power (Watts) vs. External Static Pressure with Filter Unit Outdoor Airflow Setting (CFM/ ton) External Static Pressure 0.1 0.3 0.5 0.7 0.9 450 CFM 900 900 900 900 900 Watts 95 141 191 245 301 420 CFM 840 840 840 840 840 Watts 80 124 172 223 277 400 CFM 800 800 800 800 800 Watts 71 114 160 210 262 2.0 Ton 370 350 CFM 740 740 740 740 740 Watts 59 99 143 191 242 CFM 700 700 700 700 700 Watts 52 91 133 180 229 330 CFM 660 660 660 660 660 Watts 46 83 124 169 218 310 CFM 620 620 620 620 620 Watts 40 75 115 159 207 290 CFM 580 580 580 580 580 Watts 35 68 107 150 197 450 CFM 1125 1125 1125 1125 1125 Watts 166 222 282 345 410 420 CFM 1050 1050 1050 1050 1050 Watts 139 192 248 308 370 400 CFM 1000 1000 1000 1000 1000 Watts 123 173 228 286 346 2.5 Ton 370 350 CFM 925 925 925 925 925 Watts 101 149 200 255 312 CFM 875 875 875 875 875 Watts 88 134 183 236 291 330 CFM 825 825 825 825 825 Watts 77 120 167 218 272 310 CFM 775 775 775 775 775 Watts 66 107 153 202 254 290 CFM 725 725 725 725 725 Watts 57 96 139 187 237 3.0 Ton (a) 450 420 CFM 1350 1350 1338 1263 1172 Watts 267 333 396 421 436 CFM 1260 1260 1260 1260 1172 S9V2B080D3-SUB-1A-EN 5

Heatingand AirflowTables Table 2. S9V2B080U3PSBA/ S9V2B080D3PSBA Airflow(continued) S9V2B080U3PSBA / S9V2B080D3PSBA Furnace Airflow (CFM) and Power (Watts) vs. External Static Pressure with Filter Unit Outdoor Airflow Setting (CFM/ ton) External Static Pressure 0.1 0.3 0.5 0.7 0.9 Watts 223 285 350 419 436 400 CFM 1200 1200 1200 1200 1172 Watts 196 255 318 385 436 370 CFM 1110 1110 1110 1110 1110 Watts 160 216 275 337 402 350 CFM 1050 1050 1050 1050 1050 (a) Watts 139 192 248 308 370 330 CFM 990 990 990 990 990 Watts 120 170 224 281 341 310 CFM 930 930 930 930 930 Watts 103 150 202 257 314 290 CFM 870 870 870 870 870 Watts 87 132 181 234 289 450 CFM 1460 1400 1338 1263 1172 Watts 329 363 396 421 436 420 CFM 1460 1400 1338 1263 1172 Watts 329 363 396 421 436 400 CFM 1400 1400 1338 1263 1172 Watts 294 363 396 421 436 3.5 Ton 370 350 CFM 1295 1295 1295 1263 1172 Watts 239 303 370 421 436 CFM 1225 1225 1225 1225 1172 Watts 207 267 332 399 436 330 CFM 1155 1155 1155 1155 1155 Watts 177 235 296 360 427 310 CFM 1085 1085 1085 1085 1085 Watts 151 205 264 325 388 290 CFM 1015 1015 1015 1015 1015 Watts 128 179 234 292 353 (a) Factory Setting 6 S9V2B080D3-SUB-1A-EN

General Features NATURALGAS MODELS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control is a solid state device which continuously monitors for presence of flame whenthe systemis inthe heating modeof operation. Dual solenoid combination gas valve and regulator provide additional safety. QUICKHEATING Durable, cycle tested, heavy gauge tubular stainless steel primary heat exchangerquickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower,to increase efficiency and provideapositivedischarge of gasfumesto the outside. BURNERS Multiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas with LP conversion kit. INTEGRATEDSYSTEMCONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains dry contacts for EAC and HUM. ENERGY EFFICIENT OPERATION Furnaceis certified bythe manufacturer toleak 1%or less of nominal air conditioning CFM delivered when pressurized to.5" water column with all inlets, outlets, and drains sealed. AIR DELIVERY The variable speed blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from room thermostat. SECONDARY HEAT EXCHANGER The S-Seriesfurnace hasaspecialtype 29-4C stainless steel secondary heat exchanger to reclaim heat from flue gases which would normally be lost. STYLING Heavygaugesteeland "wrap-around"cabinet constructionis used inthe cabinetwith baked-on enamel finish for strength and beauty. Every orientation has at least two venting options. There are no knockouts on cabinet. FEATURES ANDGENERALOPERATION The S-Series furnace utilizes a Silicon Nitride Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lightsthe main burnersuponademandfor heatfrom the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switches. S9V2B080D3-SUB-1A-EN 7

Features and Benefits 96.0% AFUE ACROSS ALLMODELS Meets utility rebates Lowers utility bills ELECTRICALLY EFFICIENT Efficient airflow design reduces electrical energy use 34INCHTALL Lighter,easier to moveand fit intotightspaces like short basements or tight closets Works great with larger, high-efficiency coils No knockouts 3 WAY MULTI-POISE /DEDICATEDDOWNFLOW 9SKU s Upflow/Horizontal Left /Horizontal Right 7SKU s Downflow Added application flexibility and reduction in specification errors AIRFLOW Atleast400CFM/ton at0.5in.h 2 0 externalstatic pressure; setup airflow options down to 290 CFM/ton REGULATORY Allmodelsare air tight;1%or less airleakage as per ASHRAE 193 Open vestibule design provides a full 34 high open vestibule DIMENSIONS Widths are industry standard: 17.5, 21, and 24.5 Depth remains approximately 28 Cabinet will be compatible with industry standard coils, as well as, other accessories INTEGRATEDFURNACE CONTROL Setup/ Status / Diagnostics / Digital Display No dip switches Last six errors stored Dry contact EAC and HUM connections All Molex connections; no spade terminals Low voltage labeled above and below Rain shield over IFC keeps condensate off the control TUBULAR STAINLESS STEELPRIMARY HEAT EXCHANGER 29 4C STAINLESS STEEL SECONDARY HEAT EXCHANGER Stainless steel is a more durable, corrosive-resistant material than aluminumized steel Integrated rail system for easy access if required Reduces or eliminates need for baffles VORTICA II BLOWER,DESIGNEDEXCLUSIVELY FOR THE S-SERIES FURNACE Improved airflow efficiency Durable, easy to clean, two piece housing Single piece belly band/ motor arm assembly Blower deck has full-length rails for easy removal and replacement, regardless of poise THREE WAY MULTI-POISE (UPFLOW, HORIZONTAL LEFT ANDRIGHT) PLUS DEDICATED DOWNFLOW Easier to specify Shipped ready to install (no kits required) Every model has at least two venting options When in horizontal, trap extends only about 2 Barbed fittingon trap athoseconnection and on cabinet transition for hose has barbed fitting and clamps at both ends for leak resistance. Vent table improvements including longer vent lengths;2 pipe canbeused up to 100K 8 S9V2B080D3-SUB-1A-EN

Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands including Club Car, Ingersoll Rand, Thermo King and Trane work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. ingersollrand.com Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. S9V2B080D3-SUB-1A EN 29 Mar 2017 Supersedes S9V2B080D3-SUB-1-EN (March 2016) 2016 Ingersoll Rand all rights reserved