PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

Similar documents
2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

4YCC3048A3096A /3/ /

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

Product Data YCZ6036A through 4YCZ6060A Single Packaged Convertible Gas/Electric 16 SEER 3, 4 & 5 Ton, MBTU R-410A

Product Data EN. 4DCY4024 through 4DCY4060 Packaged Convertible Dual Fuel 14 SEER 2-5 Ton, MBTU R-410A

Product Data DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, MBTU R-410A

Product Data TCC3018A through 4TCC3060A Single Packaged Convertible Cooling 13 SEER 1½ - 5 Ton R-410A 07/08

Product Data DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, KBTU R-410A

Product Data TCC3018A through 4TCC3060A Single Package Convertible Cooling 13 SEER 1½ - 5 Ton R-410A. Mar. 03, 2006

SEER 1½

Submittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG:

Submittal. Single Packaged Convertible Gas/Electric 14 SEER 4YCC4024A-SUB-1F-EN. August YCC4024A1060A TAG:

Product Data WCZ6036B through 4WCZ6060B Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A

Product Data. 4WCY4024A through 4WCY4060A Single Packaged Convertible Heat Pump 14 SEER 2-5 Ton R-410A Trane Pub. No.

Product Data. 4TCY4024 through 4TCY4060 Single Packaged Convertible Cooling 14 SEER 2-5 Ton R-410A Trane Pub. No.

Product Data. Single Packaged Heat Pump 14 SEER Convertible, 2 5 Ton B-EN. December 2014

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

Product Data WCC3018 through 4WCC3060 Single Packaged Convertible Heat Pump 13 SEER 1½ - 5 Ton R-410A 02/12

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

RGE 13 A T - 1 A

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

50TM TFF COMBINATION HEATING/COOLING UNITS

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

50TM COMBINATION HEATING/COOLING UNITS

Split System Cooling Product & Performance Data

PAR5. Product Specifications

48TF GAS HEATING/ ELECTRIC COOLING UNITS

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Split System Cooling Product & Performance Data

Split System Heat Pump Product & Performance Data

High Heat COP. High/Low Stage

PAJ3. Product Specifications

13 GEP A L P - 1 A

Product Data. Fig. 1 - Unit 50VR -A

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Split System Cooling Product Data

Advance Release September 2009

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Split System Cooling Product Data

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Split System Cooling Product Data

48TM GAS HEATING/ELECTRIC COOLING UNITS

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

PACKAGE AIR CONDITIONER

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

SKYPAK II, 3 Ton Series, gives you a

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Commercial High-Efficiency Condensing Units

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

AMERICAN STANDARD 14 MODELS 4A7B E

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Modular Multi-position Air Handler

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

SKYPAK II Heating & Cooling Self Contained Packages

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

WPH4 Product Specifications

SKYPAK II, 3 Ton Series, gives you a

Split System Heat Pump Product Data

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Model 655A Sizes

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

Split System Cooling Product Data

Split System Cooling Product Data

HEAT EXCHANGER Aluminized serpentine clamshell heat exchanger provides corrosion resistance for longer life and efficient heat transfer.

Concealed Ducted Split Series R-407C MBH

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

Split System Cooling Product Data

INSTALLATION INSTRUCTIONS

SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A. with AccuLink and Charge Assist

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

Split System Cooling Product Data XB 1000

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

Transcription:

YCC3048-SPEC-1B TAG: SPECIFICATIONS SINGLE PACKAGED GAS HEATING ELECTRIC COOLING PRODUCT SPECIFICATIONS 2/4YCC3048A107/96/120A MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Sound Rating No. Performance Heating Input BTUH (Natural Gas) AFUE Temp. Rise Min/Max ( F) Orifice Qty / Drill Size (Natural Gas) POWER CONN. V/PH/HZ Min. Brch. Cir. Ampacity Fuse Size Max. (amps) Fuse Size Recmd. (amps) COMPRESSOR Volts/Ph/Hz R.L. Amps L.R. Amps OUTDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) INDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN TYPE Dia. (in.) Drive/No. Speeds Motor HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN TYPE Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. Motor HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps COMBUSTION FAN TYPE Drive/No. Speeds Motor HP/R.P.M. Volts/Ph/Hz FLA FILTER / FURNISHED Type Recommended Recmd. Face Area (sq. ft.) REFRIGERANT Charge (lbs.) GAS PIPE SIZE (in.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 2YCC3048A107A 47000 160 4.272 77 7000 20 / 0 2 / #33 29.0 4 4 RECIPROCATING 18.6 / 93.4 20.4 3 / 1 1/4 / 82 1.4 / 3. 3/4 / 107 1/3 / 3480 0.3.3 R22 9 49.86 / 47.4 / 61.7 66 / 28 2YCC3048A1096A 47000 160 4.272 77 96000 30 / 60 3 / #37 29.0 4 4 RECIPROCATING 18.6 / 93.4 20.4 3 / 1 1/4 / 82 1.4 / 3. 3/4 / 107 1/3 / 3480 0.3.3 R22 9 49.86 / 47.4 / 61.7 63 / 3 2YCC3048A1120A 47000 160 4.272 77 120000 40 / 70 3 / #32 29.0 4 4 RECIPROCATING 18.6 / 93.4 20.4 3 / 1 1/4 / 82 1.4 / 3. 3/4 / 107 1/3 / 3480 0.3.3 R22 9 49.86 / 47.4 / 61.7 69 / 41 4YCC3048A107A 4600 1600 4.22 80 7000 20 / 0 2 / #33 31. 0 0 SCROLL 20. / 109 18.01 3 / 1 1/4 / 82 1.4 / 3. 3/4 / 107 1/3 / 3480 0.3.3 R410A 8.2 47.86 / 47.4 / 61.7 64 / 17 4YCC3048A1096A 4600 1600 4.22 80 96000 30 / 60 3 / #37 31. 0 0 SCROLL 20. / 109 18.01 3 / 1 1/4 / 82 1.4 / 3. 3/4 / 107 1/3 / 3480 0.3.3 R410A 8.2 47.86 / 47.4 / 61.7 63 / 2 4YCC3048A1120A 4600 1600 4.22 80 120000 40 / 70 3 / #32 31. 0 0 SCROLL 20. / 109 18.01 3 / 1 1/4 / 82 1.4 / 3. 3/4 / 107 1/3 / 3480 0.3.3 R410A 8.2 47.86 / 47.4 / 61.7 69 / 31 Product specification notes are on page 9. 2006 American Standard Inc. All Rights Reserved TICE: American Standard has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice.

Unit Clearance and Weight Information 2

3

4

Unit Performance Data Performance Data Cooling 2YCC3048A AT 1600 CFM (CAPACITIES ARE NET IN BTUH/1000-INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP.. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP. 72 7 78 80 KW 9 4. 30.6 36.8 42.9 4. 3.84 8 63 47.4 28.1 33.8 39.3 43.0 3.87 67 1.1 24.2 29.1 34.0 37.1 3.93 71.2 20.1 24.2 28.2 30.8 3.97 9 41.7 29.3 3.2 41.0 41.7 4.1 9 63 43. 26.9 32.3 37.6 41.1 4.18 67 46.9 23.2 27.9 32. 3. 4.2 71 0.6 19.2 23.1 26.9 29.4 4.29 9 38 27.7 33.3 38.0 38.0 4.46 10 63 39.6 2.4 30.6 3.6 38.9 4.49 67 42.7 21.9 26.4 30.7 33.6 4.7 71 46.1 18.2 21.9 2. 27.9 4.61 9 34.2 2.9 31.2 34.2 34.2 4.77 11 63 3.7 23.8 28.6 33.3 3.7 4.80 67 38.4 20. 24.7 28.8 31.4 4.88 71 41. 17.0 20. 23.9 26.1 4.93 CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPL TIPLY DATA A BY FACTOR) AIRFLOW TOTAL CAPACITY ACITY SENSIBLE CAPACITY ACITY LOW 1400 0.98 0.97 HIGH 1800 1.02 1.03 VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY ACITY = 47000 BTUH AIRFLOW = 160 CFM COMPRESSOR POWER = 3387 WATTS I.D. FAN POWER = 89 WATTS O.D. FAN POWER = 297 WATTS S.E.E.R. = 13.00 BTUH/WATT E.E.R = 11.00 BTUH/WATT ALL TEMPERATURES IN DEGREES F. 4YCC3048A AT 1600 CFM (CAPACITIES ARE NET IN BTUH/1000-INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP.. AT ENTERING D.B. TEMP. TEMP COMPR. D.B. W.B. CAP. 72 7 78 80 KW 9 43.8 29.8 3.8 41.7 43.8 3.74 8 63 4.6 27.3 32.9 38.3 41.9 3.77 67 49.2 23.6 28.4 33.1 36.1 3.83 71 3.1 19.6 23. 27.4 30.0 3.87 9 41.4 28.8 34.6 40.3 41.4 4.13 9 63 43.2 26.4 31.7 37.0 40.4 4.16 67 46. 22.8 27.4 31.9 34.9 4.23 71 0.2 18.9 22.7 26. 28.9 4.27 9 39.0 27.7 33.3 38.8 39.0 4.2 10 63 40.7 2.4 30. 3.6 38.9 4. 67 43.8 21.9 26.3 30.7 33.6 4.63 71 47.3 18.2 21.9 2. 27.8 4.67 9 36.6 26. 31.9 36.6 36.6 4.91 11 63 38.2 24.3 29.2 34.1 37.2 4.94 67 41.2 21.0 2.2 29.4 32.1.02 71 44.4 17.4 20.9 24.4 26.7.07 CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPL TIPLY DATA A BY FACTOR) AIRFLOW TOTAL CAPACITY ACITY SENSIBLE CAPACITY ACITY LOW 1400 0.98 0.97 HIGH 1800 1.02 1.03 VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY ACITY = 4600 BTUH AIRFLOW = 199 CFM COMPRESSOR POWER = 3322 WATTS I.D. FAN POWER = 92 WATTS O.D. FAN POWER = 313 WATTS S.E.E.R. = 13.00 BTUH/WATT E.E.R = 11.00 BTUH/WATT ALL TEMPERATURES IN DEGREES F. Indoor Fan Performance 2/4YCC3048A1 Horizontal Airflow 2/4YC*3048A1 -HOR Down Airflow EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0. 0.6 0.7 0.8 0.9 1.0 LOW HIGH 2/4YC*3048A1 -DOWN WATTS 687 668 649 628 606 81 1 16 - - - CFM 1863 1810 1760 1708 1648 177 1493 1391 - - - WATTS - 93 921 886 81 82 803 773 708 - - CFM - 219 2110 2017 1919 1833 173 162 1482 - - EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0. 0.6 0.7 0.8 0.9 1.0 LOW HIGH WATTS 671 60 632 614 94 71 43 12 - - - CFM 1839 179 1741 1682 1622 14 1472 1362 - - - WATTS - 901 879 87 83 813 787 74 708 - - CFM - 2080 2013 1943 1872 1797 1709 190 1418 - -

BAYCURB01A Full Perimeter Roof Mounting Curb for *****042-060A 1 7/8 6 1/8 3 1 20 19 4 3/4 10 7/8 41 7/8 19 14 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 38 7/8 3 1/8 6

BAYECON102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) HVAC Unit A Economizer rain hood Mist eliminator Outside air dampers Return air dampers Required filter kit, order separately Economizer BAYECON101A BAYECON102A Unit ApplicationM odels 2/4YC,WC3018-036A 4TC*3018-036A 2/4YC,WC3042-060A 4TC*3042-060A A 20.12" 24.37" Relief damper Roofcurb Return Duct BAYCON201A Horizontal Economizer and Rain Hood Economizer C A B D Gaskets (2) The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. Duct E Rain Hood Economizer A B C D E B AYECON200AA 22.00" 20.00" 16.87" 1 11/16 11 11/16 B AYECON201AA 24.00" 22.6" 19.00" 17 11/16 14 11/16 7

BAYOSAH002, 2% Outside Air Damper (Replaces Filter/Coil Access Panel) The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. D C A FULLY OPEN 2/3 1/3 B FULLY CLOSED Manual Fresh Air Model BAYOSAH001 BAYOSAH002 Unit Application Models 2/4YC,WC3018-036A 4TC*3018-036A 2/4YC,WC3042-060A 4TC*3042-060A A B C D 22 7/16" 20 11/16" 12 " 9 3/16" 2 3/16" 20 11/16" 12 " 9 3/16" BAYDMPR102A, 2% Motorized Outside Air Damper (Mounts Over Horizontal Return AIr Opening) A C B E D BAYDMPR101A BAYDMPR102A Unit Application Models 2/4YC,WC3018-036A 4TC3018-036A 2/4YC,WC3042-060A 4TC3042-060A A B C D E 1 13/16" 11 13/16" 10 1/4" 11 " 12 1/4" 18 3/16" 1 1/8" 10 1/4" 11 " 12 1/4" 8

BAYFLTR201A, 1" - 2" Filter Rack (Mounts in Filter/Coil Section) Filter The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 1Rated in accordance with A.R.I. Standard 210/240. Sound rated in accordance with A.R.I. Standard 270. A.R.I. standard rating conditions are: 80 D.B. 67 W.B. entering air to indoor coil. 9 D.B. entering air to outdoor coil. 2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. 3 Convertible to LPG. 4 This value is approximate. For more precise value, see Unit Nameplate. Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.0" W.C. 9

Mechanical Specification Options General All units shall be factory assembled, piped, internally wired and fully charged with refrigerant. All units shall be designed to operate at outdoor ambient temperatures as high as 11 F. Cooling capacities shall be rated in accordance with A.R.I. standards. The YC heating/cooling unit design is UL listed, specifically for outdoor applications using natural gas or propane. All units shall be designed for outdoor rooftop or ground level installation. Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint. Shipped for horizontal application, convertible to downflow. Casings All panels shall be heavy gauge steel, gasketed and insulated. Foil-faced fiber insulation shall be in the heat exchanger section. Foil-faced insulation shall be in the evaporator section. Base pan shall be heavy gauge steel. WEATHERGUARD exterior corrosion resistant screws shall be used for added resistance to rust and corrosion. Controls Refrigeration cycle controls shall include condenser fan, evaporator fan and compressor contactors. Compressors shall be equipped with a combination internal winding thermostat/current overload. Internal high pressure relief shall also be provided. Refrigeration System Compressors The Duration compressor features internal over temperature and pressure protector, total dipped hermetic motor. Other features include: roto lock suction and discharge refrigeration connections, centrifugal oil pump, low vibration and noise. Evaporator Coil Internally enhanced -inch OD seamless copper tubing mechanically bonded to aluminum fins, factory pressure and leak tested at 20 to 300 psig. All units have TXV to control refrigeration flow. Condenser Coil The Spine Fin condenser coil shall be continuously wrapped, corrosion resistant all aluminum with minimum brazed joints. This coil is inch O.D. seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Indoor Air Fan Direct-drive, forwardcurved, centrifugal wheel in a Composite Vortica Blower housing. Motor shall have thermal overload protection. Permanently lubricated motor bearings. Motor/blower assembly isolated from unit with rubber mounts. Condenser Fan Direct-drive, draw thru propeller type. Weather-proofed permanent split capacitor fan motor shall have built-in thermal overload and permanently lubricated motor bearings. Low Ambient Standard refrigerant system operation down to F. Low ambient accessory required for operation to 0 F ambient condition. Heating System Gas-Fired Heating Section Models shall provide completely assembled, wired and piped gas fired heating systems within unit. Design certified by UL, specifically for outdoor application. Threaded gas connection on the unit. Electronic Ignition System Main burner is lit each time thermostat calls for heat. Flame sensor proves flame and keeps the main burners on. Should a loss of flame occur, the main valve closes and the spark recurs within 0.8 second. When thermostat is satisfied, main burner is extinguished. Forced Combustion Blower Insures flame stability under varying wind conditions. Gives higher combustion efficiency and location flexibility. Heat Exchanger stainless steel tubes. Free floating design. Burners stainless steel. Multi-port inshot. Downflow Accessories (U.S. Domestic Models) Roof Curb The roof curb shall be designed to mate with the unit and provide support and complete weathertight installation when properly installed. Curb shall ship knocked down for field assembly, and include wood nailer strips. Economizer Modulating Economizer This accessory shall be field installed and be composed of the following items: 0-100% fresh air damper, damper drive motor fixed dry bulb enthalpy control, and low voltage polarized plug for electrical connections. Solid state enthalpy or differential enthalpy control is optional. Economizer operations shall be controlled by the preset position of the enthalpy control. A barometic relief damper shall be standard with the economizer and provide a pressure operated damper that shall be gravity closing and prohibit entrance of outside air on equipment off cycle. Manual Fresh Air Hood Manual outside air provides a fixed outside air quantity from 0 to 2 percent. Includes hood and birdscreen. Low Ambient Control Control allows cycling of compressor under low ambient cooling conditions. Required for cooling operation to 0 F. Propane Gas Conversion Kit For conversion from natural gas to LP gas. American Standard Inc. 6200 Troup Highway Tyler, TX 7707 For more information contact your local dealer TICE: American Standard has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice.