Chilled Water System Solution

Similar documents
McQuay HydroflexTM Residential and Light Commercial Chilled Water System

Chilled Water System.

Chilled Water System. All Product Brochure

Water Source Solution

Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 210 CR A5ACV Air-Cooled Chiller (R410A Inverter Series)

Product Features Technical Training 2007

Multi Digital Scroll System (R-22 and R-410A)

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

All Product Catalogue

Ceiling Mounted Cassette Unit

Fan Coil Unit. Product Catalogue. Chilled Water PRODUCT SYSTEM PCXF14. Wall Mounted. Ceiling Cassette. Ceiling Convertible. Ducted

Applica. First Edition uly 2005

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Fan Coil Unit. Product Catalogue. Chilled Water PRODUCT SYSTEM PCXF14. Wall Mounted. Ceiling Cassette. Ceiling Convertible. Ducted

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

Modular Air Cooled Scroll Chillers

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

GP SERIES Packaged Chillers

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Advantages of automatic boiler bottom blowdown

DC Inverter Smart VRF Products(R410A)

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

CRA24-B3 controlled residential ventilation

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

MAC-A R410A Series Air cooled Modular Chiller

Air Cooled Scroll Chiller

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

R410A Multi Digital Scroll System

Manusa Automatic. Doors. Safety beyond the Standard. EN16005 Power operated pedestrian doorsets. Safety in use. Requirements and test methods.

AIR COOLED MINI CHILLER

RC-0219-A. Single-Split Non Inverter Series

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Compact FREME. flash recovery energy management equipment HEAT TRANSFER SOLUTIONS

Largo & Allegro. Air Compressors. Largo & Allegro 31-90

3 rd Generation of VRV. The professional solution for your professional project

R410A Non Inverter High Static Ducted Unit

Heat Pump Air Conditioning Systems

Inverter Wall Mounted Series

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

Installation Instructions

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

Wall Mounted Split Systems

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

BFD Light Curtains The new choice for cutting edge safety for industrial doors

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

TM: MCCKCM - W B. Fan Coil Units. Models: MWM-FW Series MCM-DW Series MCK-AW/BW Series MCC-CW Series MDB-BW Series

Residential and Light Commercial Ductless Systems Catalog

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

PRODUCT GUIDE

Rollair. Air Compressors. Rollair 40 to 125 and Rollair 40 V to 125 V

Inventor of the Inverter Digital Inverter System

PTG, SWT Series. Heat Recovery Systems

SIMPLICITY FULL MODULARITY?

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

ID50series. intelligent fire alarm panels

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

EHH SERIES DRAW THROUGH FAN COILS CFM

Water-cooled chillers with High Speed Centrifugal Compressors

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

intelligent fire alarm ID60series panels

Ultimate energy saving technology

HYDRONIC RESIDENTIAL

technical data Fan coil unit FWB small duct unit

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

Compact design & easy maintenance

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Air conditioners Cooling only

Air-cooled modular Chiller. Nick Technical Engineer

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

Modular Air-cooled Chillers

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

2. FEATURES. Gold aluminum fin is offered as standard material of the condenser heat exchanger of this series of chiller.

Product Line Introduction. Karl Zhang Technical support engineer

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

The advantages of closed heating systems. White paper

All DC Inverter Multi VRF

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

Hi-Pres Cooling Products Catalogue. Product Catalogue

Hi - Wall Split Systems 12K - 18K - 24K

OPERATING INSTRUCTIONS

Amena s Globo series are a group of air conditioning products designed for markets where maximum

Ceiling Mounted Cassette Unit

SIMPLICITY OR FULL MODULARITY?

ID2000. intelligent fire alarm panel

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Screw Water Cooled Chiller SCW210

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

ID3000 intelligent. fire alarm panel

Transcription:

All Product Catalogue AP-MSM-07A Chilled ater System Solution Engineered for flexibility and performance.

CONTENTS: Chilled ater System Solution McQuay Offers ; Comprehensive Solution... 2 In Air Conditioning Needs Features Of McQuay Chilled ater Products... 3 Smart Manager... 4 McQuay Air Cooled Mini Chiller Series... 7 Tandem Compressors Air-Cooled Mini Chiller... 12 Inverter Mini Chiller... 13 McQuay Chilled ater Fan Coil Units...15 NIM & NIM PC Networking Control System...16 McQuay Chilled ater Fan Coil Units Range...17 Specification Mini Chiller Specifications... S1 Chilled ater Fan Coil Unit Specifications... S6

GLOBAL DISTRIBUTION NETORK Minneapolis Faribault Owatonna Stauntan Auburn Cramlington Cecchina SuZhou uhan ShenZhen Mexico City Sungai Buloh Cikarang Manufacturing Plant Americas USA Puerto Rico Mexico Paraguay Uruguay Guadaloupe Oceania Australia New Zealand Middle East & Africa Jordan Lebanon Oman Qatar Saudi Arabia Bahrain Morocco Morocco Iraq U.A.E. Mauritius South Africa Kenya Madagascar Ghana Nigeria Tanzania Europe England Greece Hungary Italy Norway Poland Portugal Russia Spain Belgium Tunisia Croatia Cyprus Lithuania Yugoslavia Malta Slovenia Ukraine Turkey Finland Czech Republic Romania Asia Cambodia China Hong Kong Indonesia Maldives Malaysia Singapore Thailand Vietnam Pakistan

Product Overview R22 MAC 020/025/030 C/CR MAC 040/050/060 C/CR Model Range R407C R410A M4AC 020/025/030 C/CR M5AC 020/025 CR M4AC 040/050/060 C/CR R410A Inverter M5ACV 030 CR M5ACV 055/075 CR Cooling Capacity (k) 5.0-8.1 11.7-15.5 Heating Capacity (k) 5.9-9.5 12.6-17.5 Electrical Supply 50Hz 60Hz Model Range Cooling Capacity (k) Heating Capacity (k) MM 007/010/015/020 G MM 301 1.3-6.5 5.28-13.2 MCK 020/025/030/040/050 A 2.4-11.7 14.1-19.6 Electrical Supply 50Hz 60Hz Model Range MCM 007/010/015 CB MCM 020/025/030/040/050 D Cooling Capacity (k) Heating Capacity (k) 1.9-3.1 5.9-13.2 4.0-7.2 10.3-24.9 Electrical Supply 50Hz 60Hz

MAC 080/100/120/150 C/CR M4AC 080/100/120/150 C/CR M5AC 030/040/050/055 CR M5ACV 100/135 CR 21.6-40.5 7.3-14.9 26.4-38.7 9.8-18.0 MCK 020/025/030/040/050 AH MCK 015/020/025 B MCK 010/015/020 C 3.8-5.2 3.6-5.9 2.6-5.0 9.8-12.7 7.9-10.5 4.4-7.6 MCC 010/015/020/025/028 C MCC 030/038/040/050/060 C MDB 075/100/125/150 B 2.9-15.8 2.1-4.6 5.6-32.2 4.7-9.6

INTRODUCTION McQuay Offers ; Comprehensive Solution In Air Conditioning Needs McQuay is committed to offer you with the best solution in your air conditioning needs. In the new series of chilled water products, McQuay is not just offering you with wide range of chilled water air conditioning equipments, but a comprehensive solution from selecting the equipments, designing the water piping systems to provide easy control of the complete chilled water system. This is facilitated by the user friendly computer selection programs and remote monitoring of the operation of complete system through the Smart Manager. The series of chilled water product has incorporated the technology of advanced communicating controls, microprocessor controlled chillers with a wide range and variety of fan coil unit that offers total flexibility, high technology and quality that will always meet your air conditioning demands. 2

McQuay Chilled ater Series Of Products FEATURES Year Round Comfort Can be used in variety of climates with systems that are available in two versions, cooling only and heat pump. Reliable, Precise and Efficient The refrigerant of the system is confined to within the chiller itself and therefore no refrigerant is circulating throughout the building. This will be no risk of refrigerant leakages in building or risk of poor oil return that will damage compressor caused by poor installation. Multiple compressors in McQuay chiller series offers stages capacity control that will offer better efficiency. Quality, Innovative and Compact Design McQuay chiller is designed fully equipped with reliable and quality components that are sourced from major well known supplier in the world. Multiple Temperature Zone Control The operation of the fan coil units can be managed independently by zones according to similar air conditioning comfort needs. Long Piping Applications McQuay chilled water system avoids the limitation of piping lengths and bends that exist in Direct Expansion refrigerant system. The chiller can be installed far away from the fan coil units, thus offering flexibility and creativity in the installation. 3

Controller By adopting the McQuay chilled water system, the comfort in residential and light commercial buildings such as offices, hospital, restaurant, hotel and shopping complex can be controlled and managed from just one point, that is through the Smart Manager. The Smart Manager is acting as a center to manage the operation of both the chilled water fan coil units and the chillers. Besides allowing the user to have customized control for each connected unit, the Smart Manager is also able to manage the overall system operating mode of all units based on the air conditioning system load demand of the building. FEATURES Supported Up To 50 Chillers & 120 Fan Coil Units Through the versatile Smart Manager controller, the operation of each equipments in the McQuay chilled water system connected through the chiller Bus and McQuay own proprietary NIM BUS can be managed and controlled. Chiller Network BUS Fan Coil Network BUS 4

Display Up To 46 Types Of Chiller Fault/Alarm And 6 Types Of FCU Fault/Alarm henever a fault occurred in either the chiller or fan coil unit, a signal will be sent to Smart Manager and an alarm message will appear on the LCD, showing type of alarm, alarm occurred time, date and unit. (Ch 0) Alarm 1 Comp 1 overload 01/01/00 12.00am This will greatly ease the troubleshooting process and thus reduce the valuable time of service technicians. As soon as the fault is being solved, the alarm will automatically dissolve from the LCD. Priority Settings Depending on the application requirement, the Smart Manager offers the flexibility to allow user to set the priority on the operation of fan coil unit and chiller in a complete McQuay chilled water product system. If priority is set to Fan Coil Unit, the chiller will be forced to OFF if all fan coil units are OFF. If Chiller Priority is being set, all fan coil units will be OFF if chillers are OFF. Threshold Value Setting If the priority setting is being preset to fan coil unit, the operating mode of the complete McQuay chilled water system can be synchronized to operate under one same mode. This is achievable through the unique feature called Threshold Value Setting Smart Manager can command chiller operating mode to switch from current operating mode if the threshold value is meet. Example, In a network of 10 fan coil units that is currently operating in COOL mode and a threshold of 60% was set for COOL mode and threshold of 50% was set for HEAT mode. Should 6 of the fan coil units are requesting for HEAT mode then the threshold for HEAT is crossed. Signal will be sent by Smart Manager to chiller BUS to switch the operating mode of all chillers to HEAT mode. Requirement of users will be met. Heat Treshold Chiller to operate at Heat Mode 0 1 2 3 4 5 6 7 8 9 10 Chiller to operate at Cool Mode Cool Treshold 5

Energy Saving Programmable Timer The operation of the chiller and each fan coil unit can be preset to operate and to stop at different time schedule and at different day of a week. Taking consideration of the fact that certain rooms in a building will be empty at certain period of the day, setting timer to On and to Off the operation of units in those areas will greatly reduce the energy cost of the building. MCC MCK MCM 2 At the same time, Smart Manager allows setting up to five sets of 7 days programmable operating schedules (2 On/Off timer per day) for each fan coil unit. MCM 1 MM Unit MCC MCK MCM2 MCM1 MM 8.00 am 9.00 am 10.00 am 11.00 am 12.00 am 1.00 pm 2.00 pm 3.00 pm 4.00 pm 5.00 pm 6.00 pm 7.00 pm Time HOLIDAY SETTINGS Holiday 1 Holiday 2 Holiday 3 Holiday 4 Holiday 5 Holiday Setting hile designing the Smart Manager, the practical aspects of equipment application were always the key points to be considered. Thus resulting in the creation of Holiday Setting feature. Set Holiday 1 Month : 1 Day : 1 Duration : Disable In this feature, users are allowed to set up to 10 holiday timers with each timer can last for duration of 99 days. During the duration of Holiday Timer set earlier, all fan coil units and chiller will automatically be turned Off. 6

Memory Backup (EEPROM), Alarm Memory for Chiller and FCU hen there is power failure occurs during operation, Smart Manager will load the last state memory from EEPROM after power On reset. Besides, extra memory space inside the Smart Manager will allow user to view the previous alarm records even though its have been dissolved. This useful information will benefit the service technician to view the history of maintenance record done to the unit. Password Protection For Advanced Parameter Settings (Chiller) A McQuay chilled water product system with key parameters that were set by experience professionals to optimize operating conditions will need to be protected against any unauthorized disturbance or changes. The built in Password Settings feature will prevent the losing of key parameter settings in the Smart Manager and ensure the users that they will continue to enjoy the comfortable environment. Low Power Mode (Chiller + FCU) Key Parameter Display For easy serviceability and maintenance, Smart Manager is able to display the key parameter such as defrost and compressor discharge sensor temperature, water in/out temperature, status of compressor On/Off, Cool/Heat mode water in temperature, etc. Thus, it reduces the cumbersome of requiring the service technicians to physically go to site of chiller installation to do the troubleshooting process. Accumulative Compressor Run Time User can also check the compressor run time of chiller in Smart Manager. It will provide a guideline as well as posting a reminder for requirement of routine system service. Multiple Temperature Zone Control The operation of the fan coil units can be managed independently by zones according to similar air conditioning comfort needs. Smart Manager will turn into low power mode during electricity power breakdown. It will operate based on the built in backup battery and only one timer and interrupt is active. CPU operation is Off and no display on LCD as well for energy saving purpose. Real Time Clock (RTC) RTC will always appear at the summary pages and the user is able to set the time and date. 7

McQuay Air Cooled Mini Chiller Series McQuay offering you the range of air cooled chiller that is suitable for many applications from residential to commercial. The McQuay chiller is incorporated with all the necessary components such as circulating water pump, expansion tank, compact brazed plate heat exchanger, differential pressure switch and the microprocessor controller and wired control panel. In addition, the selection of the McQuay chiller could not be more easy than the user friendly yet versatile selection softwares for chiller as well as connecting piping. In short, Smart Manager Chilled ater Product Range offers you the all-in-one solution to your chilled water product needs. Smart Manager air cooled chiller makes your life easy. McQuay is participating in EUROVENT certification program 8

PRODUCT RANGE Model : MAC 020/025/030 C/CR M4AC 020/025/030 C/CR M5AC 020/025 CR M5ACV 030 CR Capacity : Cooling : 5 k to 8.1 k Heating : 5.9 k to 9.5 k Refrigerant : R22, R407C, R410A Model : MAC 040/050/060 C/CR M4AC 040/050/060 C/CR M5ACV 055/075 CR Capacity : Cooling : 11.7 k to 15.5 k Heating : 12.6 k to 17.5 k Refrigerant : R22, R407C, R410A Model : MAC 080/100/120/150 C/CR M4AC 080/100/120/150 C/CR M5ACV 100/135 CR Capacity : Cooling : 21.6 k to 40.5 k Heating : 26.4 k to 38.7 k Refrigerant : R22, R407C, R410A Model : M5AC 030/040/050/055 CR Capacity : Cooling : 7.3 k to 14.9 k Heating : 9.8 k to 18.0 k Refrigerant : R410A 9

FEATURES Compactness Brazed Plate Heat Exchanger The MAC/M4AC 020~030 C/CR is such a compact unit that it can be integrated perfectly with any architectural design, making it an ideal choice for house, offices, restaurant and shop. The heat exchanger is made of AISI 316 stainless steel plates closely arranged and brazed together to ensure high heat exchange efficiency. Scroll Compressor Scroll Compressors are used for the units to offer a quiet and reliable performance over a wide operating temperature range. (Except MAC/M4AC 020 C/CR which uses rotary compressor). For MAC/M4AC 030, 040, 050, 060, 080, 100, 120, 150 CR, phase protector is provided to prevent the compressor from rotating in the wrong directions. Fully Equipped Chillers McQuay chiller is fully integrated and equipped with key hydronic components such as expansion tank, water tank, brazed plate heat exchanger and water circulating pump. The all in one concept will ease the job of installer. Microprocessor Control McQuay chillers are equipped with microprocessor controller that will control and regulate the operation of the unit. Besides, the controller that contains the well developed algorithm will provide protection to the chiller by accurately sensing the key temperatures in both the water and refrigerant circuit. Should there be any abnormal reading received by controller, an alarm signal will be sent to chiller panel, followed by protection action plans such as to stop the operation of compressor, condenser fan motor or circulating water pump. Partial Loading Models MAC/M4AC 080~150 C/CR has been designed with two separate refrigerant circuits, i.e. it has two compressors. By doing so, the unit has part loading capabilities, i.e. 0-50-100% of rated capacity. This will improve the reliability and energy efficiency of the unit, especially during low loading operations. 10

Availability Of Connection To Boiler The microprocessor controller has a built in control algorithms that allowed the chiller to be connected to the boiler. By adding a boiler to the system, it can either work as the sole heating water source in a Cooling only unit or it can act as the booster heat source to the Heat Pump chiller. Safety Protection The safety protections provided for the McQuay chiller are: High & Low Pressure Switches Anti-Freeze Protection Sensor Discharge Temperature Sensor Over Pressure Relief Valve ater Pressure Differential Switch Anti-Freeze Heater on BPHE Compressor ater Pump & Fan Motor Overload Protector Anti-Freeze Protection The chiller unit has several anti-freeze protection features: 1. Built-in heater in BPHE The BPHE has a strip heater around it to prevent water freezing inside. 2. Anti-Freeze sensor BPHE can avoid the frosting as the antifreeze sensor will send the signal to cut out the compressor if the water temperature becomes too cold. 3. ater pressure differential switch This protection feature will ensure there is water flow in pipings when the chiller is in operation. Otherwise, the compressor will cut out immediately. Sequencing Control For MAC/M4AC 080~150 C/CR, both compressors will cut in and cut out depending on their accumulative operating time. This sequencing control feature will ensure no single compressor is overload in operation as well as to ensure longer reliability of compressors. Modular Installation Chiller Bus The mini chillers are available for modular connection. A network of up to 50 chillers in a system is possible. Control on the operation of the chillers will be done through the microprocessor controller. The external water piping connection can be made either from the left or right side of the unit. ater In ater Out Up to 50 Chillers 11

FEATURES Easy Installation And Maintenance Brazed Plate Heat Exchanger As a chiller, all hydronic components are assembled and wiring jobs on chillers are done and tested in the factory. Thus, there is no need for installer to select for the component again on site. In addition, unit operation is user friendly and maintenance is simple. By opening the front panel, you would have immediate assess to all components. Factory Precharged Refrigerant Each heat exchanger in the chiller is brazed and tested against leakages through dried air at 30 bars. After that, another process to vacuum the system before accurately charged with refrigerant to ensure optimum performance. Thus, it saves the hustles of field charging by installers. Anti Corrosion Heat Exchanger The condenser heat exchanger of chiller, heat pump specification, utilize the special anti corrosion gold aluminum fin. Zero Ozone-Depleting Potential Refrigerant In line with Montreal Protocol on encouragement of more usage of Zero Ozone-Depleting Potential refrigerant, McQuay chiller is available in R407C & R410A series. The heat exchanger is made of AISI 316 stainless steel plates closely arranged and brazed together to ensure high heat exchange efficiency. Chiller Control Panel The chiller panel controller is designed to control the chiller operation. This device allows the user to have customized control for each connected unit. Each chiller will have a chiller control panel that comes as a standard accessory. At the same time, the chiller control panel is able to be installed remotely through the cable up to a distance of 100 meters. Example, the chiller panel can be installed in a centralized plant control room for the building. The chiller control panel has been designed taking into consideration of the user friendly and yet versatile control features. Features: hole system configuration. Unique parameter settings. Operation status display. Tracing fault record (offer quick troubleshooting solutions). The display is shown in an 8-lines graphical LCD display. There are 8 dedicated keys available in the panel. Menu selection. Navigation on the screen. Modification of the selected value. 12

Air - Cooled Mini Chiller This new line of innovative air cooled chiller by McQuay was designed with one purpose in mind, which is to offer user with cost and energy saving for users. High Seasonal Efficiency Usage of high efficient R410A rotary compressors in tandem configuration Extremely tight tolerances between moving parts resulting in high compressor volumetric efficiency Minimize mechanical losses Minimize gas flow losses and turbulence Optimize compressor oil return Capacity Step Control 3 steps compressor loading (0%-40%-60%-100%) for M5AC 040 CR & M5AC 050 CR 2 steps compressor loading (0%-50%-100%) for M5AC 030 CR & M5AC 055 CR Sequential Control Both compressors will cut in cut out depending on water temperature. This is definitely improving the compressor life cycle as well as the compressor reliability. Elimination of ater Tank Combining the Tandem Compressors technology with the algorithm of the microprocessor control, water tank can be eliminated in most instances. Choices of Single Phase and 3 Phase Power Supply Connection Usage of single phase power supply compressors and circulating water pump. Offers flexibility to field installation. 13

The new series of Inverter Mini Chillers are specially designed / developed to achieve better system energy saving as well as towards perfect control during part load condition. True Dual Circuits BPHE Apply sophisticated technology of true dual circuit BPHE. The true dual BPHE puts the secondary circuit (water) in contact with 2 primary circuits (refrigerant). So even if one primary circuit is shut off, each secondary channel is still in contact with a primary channel. These advantages have made the product the natural choice for flexible chillers, climate control applications and high-precision systems food cooling cabinets in supermarkets. Ref.1 Ref.2 Ref.1 Ref.2 Ref.1 Built In Fan Speed Fan speed is now controlled by the built in algorithm, resulting in cost saving since installation of external FSC (Fan Speed Controller) can be exempted. It is regulated at 100%, 70% and 50% based on the ambient and outdoor condensing water water water water temperature. Inverter Compressor Safety Protection Inverter compressor is programmed to run at the optimum speed, which is regulated by the input frequency as it can varies according to the heat load requirement. ater In High & Low Pressure Switches Anti-Freeze Protection Sensor Discharge Temperature Sensor Over Pressure Relief Valve ater Pressure Differential Switch Anti-Freeze Heater on BPHE Compressor, ater Pump Overload Protector Primary Circuit 1 Primary Circuit 2 Anti Corrosion Heat Exchanger ater Out Gold Aluminum fin is offered as the standard material of the condenser heat exchanger of this series of chiller. 14

Room Temperature Set Temperature Room Temperature Set Temperature Precise & Stable Temperature Control Time Fast Cooling Time High Cooling ESEER And Heating COP The ability of the compressor to regulate at different frequency has lead to the outstanding figure in term of Cooling ESEER as well as the Heating COP of the inverter mini chiller. Inverter System Conventional System Advantages of inverter compressor applications are: LESS START & STOP Frequency regulated compressor resulting in lesser in the sense of start and stop of compressor, which is greatly reduce the energy consumption. FAST COOLING / HEATING Unlike the other conventional systems, inverter compressor has the ability to produce faster cooling / heating capacity at the frequency higher than the dominant capacity frequency. SMART LOADING / UNLOADING ith the integration of built in system algorithm; inverter compressor could control the system loading and unloading sophisticatedly. BETTER COMPRESSOR RELIABILITY Reliability of inverter compressor is always better since there is lesser ON/OFF of the system especially during the low load condition. LO STARTING SURGE Inverter compressor require lower starting torque and thus, resulting in lower starting current. Heating COP Cooling SEER Cooling SEER of Inverter Mini Chiller 12 10 8 6 4 2 0 5ACV30CR 5ACV55CR 5ACV75CR 5ACV100CR 5ACV135CR 5ACV210CR Model Heating COP of Inverter Mini Chiller 4.00 3.00 2.00 1.00 0.00 5ACV30CR 5ACV55CR 5ACV75CR 5ACV100CR 5ACV135CR 5ACV210CR Model Modular Installation A network up to 50 chillers in a system is possible. Control on the operation of the chillers will be done through the microprocessor controller. The external water piping connection can be made either from the left or right side of the unit. Elimination Of ater Tank Inverter system provide constant water temperature band, or much lesser water temperature fluctuation. ith this, water tank of the mini chiller system can be eliminated. Chiller Panel Comes As The Standard Controller Compatible ith Smart Manager 15

McQuay Chilled ater Fan Coil Units To complement the new innovative Smart Manager range of air cooled chillers, McQuay is offering an extensive range of chilled water fan coil units that will meet any indoor application requirements covering residential, light commercial and commercial. The aesthetically attractive decorative fan coil units such as all Mounted models, Ceiling Cassette and Ceiling Convertible is compact and ergonomic, the ranges can blend in easily to any interior designs whether it is residential houses, office, restaurant or shops. In addition, the McQuay chilled water fan coil units are designed with easy installation and easy servicing in mind. The fan coil units also include the microprocessor controller that has built in algorithm to control the operation of the fan coil unit as well as to provide protection to the unit. 16

NIM Networking Control System (optional) For multiple fan coil unit installation in an office, a centralised controlled operation can be achieved through the McQuay proprietary NIM networking system. Network Interface Module (NIM) is a networking system which enables communication among McQuay air conditioners. ith the NIM, all your air conditioning systems can be controlled with just a single controller giving you boundless benefits: BENEFITS Ultimate convenience. No more individually controlling air conditioning units Quick and easy zone control from the master control unit Better control of air conditioning systems operating conditions NIM utilizes master-slave type system whereby the master node will issue commands to each of the slave nodes. For NIM PC only NIM NIM NIM NIM NIM NIM NIM NIM NIM NIM PC for Global Control Hub ith NIM PC, a personal computer will act as a centralised unit for both controlling and monitoring of all the air conditioning units in the HydroNIM network. For controlling, settings can be set from the PC and send out to the system for execution. hile for monitoring, there is a graphical user interface for displaying the status of each unit. The NIM PC provides a Global Control Hub that offers comprehensive control for better system management: Easy to operate full graphical user interface. Control online units globally, as a group, or as individual units. Configure a super master unit. Support up to 42 On/Off timers per week. Real time monitoring of online units. Error diagnostic and alerting features for all units. Data logging and printing ability. Database to store unit location. Login protected by password. 17

McQuay Chilled ater Fan Coil Units Range all Mounted Range Features : MM 07/10/15/20/25 G Slim and compact ide capacity range ide air flow range Incorporated with NanoGuard which effectively inactive & eliminate various harmful airbone elements. Able to communicate with the versatile NIM for fan coil units networking Light weight Detachable and washable air intake grille Microprocessor control Self diagnosis features Automatic air swing ireless Control as standard Mode selection, fan speed, 24 hours real timers Optional wired controller MM 301 STANDARD M-G M301 OPTIOL G11 ireless Controller G6 ireless Controller SLM ired Controller AC-5300 ireless Controller Ceiling Cassette Range Features : MCK 010/015/020 C MCK 015/020/025 B 2 Pipes System: MCK 020/025/030/040/050 A 3 range of ceiling cassette to be chosen from. - MCK-C - 570mm (w) x 570mm (l) - MCK-B - 650mm (w) x 650mm (l) - MCK-A - 820mm (w) x 820mm (I) Aesthetically attractive and slim front panel 4 way air discharge to provide better air distribution to room Automatic air swing 4 pipes system is available for model MCK020/025/030/040/050AH Easy servicing and maintenance Built in high pressure head drain pump - Ability to pump up condensate water to 700mm high Built in water float switch to protect the unit from problems of condensate water overflow Microprocessor control Able to communicate with the versatile NIM for fan coil units networking Self diagnosis feature ireless Control as standard - Mode selection, fan speed, 24 hours real timers Optional wired controller STANDARD OPTIOL 4 Pipes System: MCK 020/025/030/040/050 AH G7 ireless Controller Netware III ired Controller 18

Ceiling Convertible Range Features : MCM 007/010/015 CB MCM 020/025/040/050 D Ceiling Convertible feature offers flexibility on installation - Installation method of under ceiling or floor standing 2 way air discharge ensure better air distribution - Horizontal air throw and bottom air throw Automatic Air swing Aesthetically attractive with round profile outlook fits into to any indoor architectural Strong air flow volume and strong air throw distance makes it a perfect choice for light commercial such as restaurant and shop Microprocessor control Able to communicate with the versatile NIM for fan coil units networking Self diagnosis feature ireless Control as standard - Mode selection, fan speed, 24 hours real timers Optional wired controller STANDARD OPTIOL MCM 15/20/25 E G7 ireless Controller SLM ired Controller AC-5300 ireless Controller Ceiling Concealed Range Features : MCC 010/015/020/025/030/040/050/060 C ide capacity range 4 speed fan motor offers flexibility for installation to suit application - Each speed will offer different external static pressure and air flow High External Static Pressure is available up to 18mm Extra secondary drain pan to provide protection against condensate water leaking Availability of various optional duct accessories specially designed to fit to MCC-C range Microprocessor control Filter adaptor kit of 1 inch is available as optional accessory Able to communicate with the versatile NIM for fan coil units networking Self diagnosis feature ired Control as standard - Mode selection, fan speed selection MCC 028/038 C STANDARD OPTIOL SLM ired Controller Netware III ired Controller 19

Ceiling Concealed Range Features : 2 Pipes System: MC 200/300/400/600/800/1000/1200 C 4 Pipes System: MC 200/300/400/600/800/1000/1200 CH ide capacity range Multiple rooms can be cooled by just 1 unit of MC Simple design with easy serviceability feature Extremely low height of unit 251mm for complete range ater piping connection can be easily converted from one side to the other Fan motor assembly is not cased, allowing free return or back return or bottom return with optional return plenum Availability of optional extended drain to receive the condensate water dripping from the water piping connection Availability of 4 pipes MC series Other optional accessory available: - ired thermostat - Choice of external static pressure (ESP) - Four types of ESP are available: 0Pa, 30Pa, 60Pa, 80Pa. - PTC (Positive Temperature Coefficient) electric heater - 2 way & 3 way valves Ducted Blower Range Features : These units are design with high air flow and high external static pressure, enables adequate distribution of air to the desired space Multiple rooms can be cooled by just 1 unit of MDB Simple design with easy serviceability feature The robust unit is designed with durability and reliability in mind MDB125/150B is using the belt driven fan motor and blower fan thus it offers flexibility for upgrading should higher air flow is required MDB150B is designed to cater for either horizontal air discharge or vertical air discharge MDB 075/100/125/150 B Return Bracket Assembly come with Adaptor (MCC 010C - 1 outlet; MCC 015~020C - 2 outlets) Adaptor Discharge and Return Y-Joint Return Grille Assembly come with Adaptor Supply Grille Assembly come with Adaptor (Front View) (Side View) (Front View) Optional Accessories (MCC010C~MCC025C) 20

AC8000C Series AC80000A Smart Manager AC80000C NIM PC RS485 OR More FCUs FCU AC8000C FCU AC8000C FCU AC8000C LCD Panel LCD Panel LCD Panel A new developed thermostat series, AC8000 is now available to be ordered as Chilled ater Fan Coil unit controller, inclusive of AC8000A and AC8000C. Its adopt micro-computer technology and is designed for the ease of installation, low power consumption as well as towards precise operation. AC8000A practises the most simple and conventional installation method where it consists of a wired controller and a power board. Both of its are attached together while being installed. Same with AC8000A, AC8000C also consist of a wired controller and a power board, but the power board is attached to the fan coil unit while the wired controller will be installed away from it. Moreover AC8000C has the networking capability, with compatibility to the Network Interface Module (NIM); better control over whole operating system can be achieved as it offers quick and easy zone control from the master operating unit. Features : Four Operating Modes COOL/ FAN/ HEAT/ AUTO Variable Indoor Fan Speed Selection High/ Medium/ Low/ Auto Selectable Function Cooling Only, Cooling and Heating (2 pipes), Cooling and Heating (4 pipes) LCD display LED Indication of Power Supply 7 days Programmable Timer Real Timer Selectable Room Temperature/ Set Temperature Display Temperature Control Precision up to +/- 1 C High, Low Voltage Separated for Safety Last State Memory Backup Networking Capability (Only Applicable for AC8000C) AC8000C is compatible with Smart Manager and NIM PC. By using a RS485 cable, it can easily form a NIM bus as described in schematic diagram. 21

Mini Chiller Specifications MAC020C - MAC060C (Cooling Only, R22) NOMIL COOLING CAPACITY NOMIL TOTAL INPUT POER MAC020C MAC025C MAC030C MAC040C MAC050C MAC060C 18000 23500 27500 40000 50000 53000 5275 6887 8059 11723 14654 15533 2669 2730 3491 4470 5245 6361 POER SOURCE REFRIGERANT TYPE CONTROL V/Ph/Hz 220-240 / 1 / 50 380-415 / 3 / 50 R22 CAPILLARY TUBE 800 / 31.5 1410 / 55.5 UNIT DIMENSION IDTH 1160 / 45.7 1160 / 45.7 460 / 18.1 460 / 18.1 UNIT EIGHT SOUND PRESSURE LEVEL kg/lb 116 / 256 123 / 271 128 / 282 195 / 430 196 / 432 203 / 448 dba 57 57 58 60 60 61 EVAPORATOR NOMIL ATER FLO HYDRAULIC KIT MAX. ATER OPER. PRESSURE PUMP ATER FLO RATE INSTALLATION PIPE CONNECITON PIPING HEAD l/s/m 3 /hr 0.25 / 0.9 0.33 / 1.2 0.39 / 1.4 0.56 / 2.0 0.70 / 2.5 0.74 / 2.7 1000 / 145 l/s/m 3 /hr 0.25 / 0.9 0.33 / 1.2 0.39 / 1.4 0.56 / 2.0 0.70 / 2.5 0.74 / 2.7 25.4 / 1 m 8.4 9.7 8.8 9.2 6.8 6.6 TANK MATERIAL CAPACITY/VOLUME L/ft 3 22 / 0.78 CAST IRON / STAINLESS STEEL 40 / 1.41 COMPRESSOR STAGE OF CAPACITY CONTROL () 0-100% MAC020CR - MAC060CR (Heatpump, R22) MAC020CR MAC025CR MAC030CR MAC040CR MAC050CR MAC060CR NOMIL COOLING CAPACITY NOMIL HEATING CAPACITY 18000 23000 27500 40000 46000 53000 5275 6740 8060 11723 13481 15533 22000 25000 31500 43000 52000 59000 6448 7327 9232 12602 15240 17292 COOLING 2599 2779 3541 4560 5046 6551 NOMIL TOTAL INPUT POER HEATING 2770 2614 3561 4629 4999 6247 POER SOURCE REFRIGERANT TYPE CONTROL UNIT DIMENSION UNIT EIGHT SOUND PRESSURE LEVEL EVAPORATOR NOMIL ATER FLO HYDRAULIC KIT PUMP PIPING HEAD TANK IDTH MAX. ATER OPER. PRESSURE INSTALLATION PIPE CONNECITON MATERIAL COMPRESSOR ATER FLO RATE CAPACITY/VOLUME STAGE OF CAPACITY CONTROL () V/Ph/Hz kg/lb 116 / 256 123 / 271 128 / 282 195 / 430 196 / 432 203 / 448 dba 57 57 58 60 60 61 COOLING l/s/m 3 /hr 0.25 / 0.9 0.32 / 1.2 0.39 / 1.4 0.56 / 2.0 0.64 / 2.3 0.74 / 2.7 HEATING l/s/m 3 /hr 0.31 / 1.1 0.35 / 1.3 0.44 / 1.6 0.60 / 2.2 0.73 / 2.6 0.83 / 3.0 COOLING l/s/m 3 /hr 0.25 / 0.9 0.32 / 1.2 0.39 / 1.4 0.56 / 2.0 0.64 / 2.3 0.74 / 2.7 HEATING l/s/m 3 /hr 0.31 / 1.1 0.35 / 1.3 0.44 / 1.6 0.60 / 2.2 0.73 / 2.6 0.83 / 3.0 COOLING m 8.4 9.9 8.8 9.2 8.2 6.6 HEATING m 6.9 9.4 7.9 8.1 6.0 4.0 L/ft 3 220-240 / 1 / 50 380-415 / 3 / 50 CAPILLARY TUBE 800 / 31.5 1410 / 55.5 1160 / 45.7 1160 / 45.7 460 / 18.1 1000 / 145 25.4 / 1 CAST IRON / STAINLESS STEEL 22 / 0.78 40 / 1.41 0-100% Notes: 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253. 3) NOMIL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELO : a) COOLING - 12ºC / 7ºC ENTERING / LEAVING EVAPORATOR ATER TEMPERATURE, 35ºC AIR AMBIENT TEMPERATURE. b) HEATING - 40ºC / 45ºC ENTERING / LEAVING EVAPORATOR ATER TEMPERATURE, 7ºC AIR AMBIENT TEMPERATURE. 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELO THE UNIT. R22 460 / 18.1 S1

Mini Chiller Specifications M4AC020C - M4AC060C (Cooling Only, R407C) M4AC020C M4AC025C M4AC030C M4AC040C M4AC050C M4AC060C NOMIL COOLING CAPACITY 21000 23000 27000 40000 6154 6740 7912 11723 50000 14654 52000 15240 NOMIL TOTAL INPUT POER 2617 2949 3679 4910 5955 6859 POER SOURCE V/Ph/Hz 220-240 / 1 / 50 380-415 / 3 / 50 REFRIGERANT TYPE CONTROL R407C CAPILLARY TUBE 800 / 31.5 1410 / 55.5 UNIT DIMENSION IDTH 1160 / 45.7 1160 / 45.7 460 / 18.1 460 / 18.1 UNIT EIGHT kg/lb 116 / 256 123 / 271 128 / 282 195 / 430 196 / 432 203 / 448 SOUND PRESSURE LEVEL dba 57 57 58 60 60 61 EVAPORATOR NOMIL ATER FLO l/s/m 3 /hr 0.29 / 1.0 0.32 / 1.2 0.38 / 1.4 0.56 / 2.0 0.70 / 2.5 0.73 / 2.6 HYDRAULIC KIT PUMP MAX. ATER OPER. PRESSURE ATER FLO RATE 1000 / 145 l/s/m 3 /hr 0.29 / 1.0 0.32 / 1.2 0.38 / 1.4 0.56 / 2.0 0.70 / 2.5 0.73 / 2.6 INSTALLATION PIPE CONNECITON PIPING HEAD 25.4 / 1 m 7.3 9.9 8.9 9.2 6.8 7.0 TANK MATERIAL CAPACITY/VOLUME L/ft 3 22 / 0.78 CAST IRON / STAINLESS STEEL 40 / 1.41 COMPRESSOR STAGE OF CAPACITY CONTROL () 0-100% M4AC020CR - M4AC060CR (Heatpump, R407C) M4AC020CR M4AC025CR M4AC030CR M4AC040CR M4AC050CR M4AC060CR NOMIL COOLING CAPACITY 17000 22000 25000 40000 4982 6448 7327 11723 46000 13481 51000 14947 NOMIL HEATING CAPACITY 20000 25500 32500 45000 5861 7474 9525 13188 51000 14947 60000 17584 NOMIL TOTAL INPUT POER COOLING 2597 3076 3804 4820 HEATING 2685 2745 4004 4994 5446 5647 6507 6268 POER SOURCE V/Ph/Hz 220-240 / 1 / 50 380-415 / 3 / 50 REFRIGERANT TYPE R407C CONTROL CAPILLARY TUBE 800 / 31.5 1410 / 55.5 UNIT DIMENSION IDTH 1160 / 45.7 1160 / 45.7 460 / 18.1 460 / 18.1 UNIT EIGHT kg/lb 116 / 256 123 / 271 128 / 282 195 / 430 196 / 432 203 / 448 SOUND PRESSURE LEVEL dba 57 57 58 60 60 61 EVAPORATOR NOMIL ATER FLO COOLING l/s/m 3 /hr 0.24 / 0.9 0.31 / 1.1 0.35 / 1.3 0.56 / 2.0 HEATING l/s/m 3 /hr 0.28 / 1.0 0.36 / 1.3 0.46 / 1.7 0.63 / 2.3 0.64 / 2.3 0.71 / 2.6 0.71 / 2.6 0.84 / 3.0 HYDRAULIC KIT MAX. ATER OPER. PRESSURE kpa / psi 1000 / 145 PUMP COOLING l/s/m 3 /hr 0.25 / 0.9 0.32 / 1.2 0.35 / 1.3 0.56 / 2.0 ATER FLO RATE HEATING l/s/m 3 /hr 0.31 / 1.1 0.35 / 1.3 0.46 / 1.7 0.63 / 2.3 INSTALLATION PIPE CONNECITON 25.4 / 1 PIPING COOLING m 8.7 10.1 9.4 9.2 HEAD HEATING m 7.7 9.3 7.6 7.5 TANK MATERIAL CAST IRON / STAINLESS STEEL CAST IRON / STAINLESS STEEL CAPACITY/VOLUME L/ft 3 22 / 0.78 COMPRESSOR STAGE OF CAPACITY CONTROL () 0-100% 0.64 / 2.3 0.71 / 2.6 0.71 / 2.6 0.84 / 3.0 8.2 7.5 6.4 3.5 CAST IRON / STAINLESS STEEL 40 / 1.41 Notes: 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253. 3) NOMIL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELO : a) COOLING - 12ºC / 7ºC ENTERING / LEAVING EVAPORATOR ATER TEMPERATURE, 35ºC AIR AMBIENT TEMPERATURE. b) HEATING - 40ºC / 45ºC ENTERING / LEAVING EVAPORATOR ATER TEMPERATURE, 7ºC AIR AMBIENT TEMPERATURE. 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELO THE UNIT. S2

Mini Chiller Specifications MAC080C - MAC150C (Cooling Only, R22) MAC080C MAC100C MAC120C MAC150C NOMIL COOLING CAPACITY 78000 22860 93000 27257 116000 33998 138000 40445 NOMIL TOTAL INPUT POER 8667 10175 11005 13779 POER SOURCE V/Ph/Hz 380-415 / 3 / 50 REFRIGERANT TYPE R22 CONTROL TXV 1245 / 49.0 UNIT DIMENSION IDTH 1500 / 59.1 1800 / 70.9 900 / 35.4 1150 / 45.3 UNIT EIGHT kg/lb 340 / 750 350 / 772 460 / 1014 540 / 1190 SOUND PRESSURE LEVEL dba 65 66 67 69 EVAPORATOR NOMIL ATER FLO l/s/m 3 /hr 1.08 / 3.9 1.31 / 4.7 1.67 / 6.0 2.00 / 7.2 HYDRAULIC KIT PUMP MAX. ATER OPER. PRESSURE ATER FLO RATE l/s/m 3 /hr 1.08 / 3.9 1.31 / 4.7 1000 / 145 1.67 / 6.0 2.00 / 7.2 PIPING INSTALLATION PIPE CONNECITON HEAD m 26.0 23.5 42 / 1 1/4" 25.0 23.0 TANK MATERIAL CAPACITY/VOLUME L/ft 3 COMPRESSOR STAGE OF CAPACITY CONTROL () 0-50 - 100% MAC080CR - MAC150CR (Heatpump, R22) MAC080CR MAC100CR MAC120CR MAC150CR NOMIL COOLING CAPACITY 77000 22567 94000 27549 113000 33118 138000 40445 NOMIL HEATING CAPACITY 90000 26376 110000 32239 120000 35169 132000 38686 NOMIL TOTAL INPUT POER COOLING HEATING 9577 9329 11255 10759 11714 11948 13881 14572 POER SOURCE V/Ph/Hz 380-415 / 3 / 50 REFRIGERANT TYPE R22 CONTROL CAPILLARY TUBE 1245 / 49.0 UNIT DIMENSION UNIT EIGHT IDTH kg/lb 350 / 772 1500 / 59.1 900 / 35.4 360 / 794 480 / 1058 1800 / 70.9 1150 / 45.3 560 / 1235 SOUND PRESSURE LEVEL dba 65 66 67 69 EVAPORATOR NOMIL ATER FLO COOLING HEATING l/s/m l/s/m 1.08 / 3.9 1.14 / 4.1 1.31 / 4.7 1.37 / 4.9 1.67 / 6.0 1.79 / 6.4 2.00 / 7.2 2.10 / 7.6 HYDRAULIC KIT MAX. ATER OPER. PRESSURE 1000 / 145 PUMP COOLING ATER FLO RATE HEATING INSTALLATION PIPE CONNECITON l/s/m 3 /hr l/s/m 3 /hr 1.08 / 3.9 1.14 / 4.1 1.31 / 4.7 1.37 / 4.9 42 / 1 1/4" 1.67 / 6.0 1.79 / 6.4 2.00 / 7.2 2.10 / 7.6 PIPING HEAD COOLING HEATING m m 26.0 25.0 23.5 22.5 25.0 24.5 23.0 22.5 TANK MATERIAL CAPACITY/VOLUME L/ft 3 COMPRESSOR STAGE OF CAPACITY CONTROL () 0-50 - 100% Notes: 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253. 3) NOMIL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELO : a) COOLING - 12ºC / 7ºC ENTERING / LEAVING EVAPORATOR ATER TEMPERATURE, 35ºC AIR AMBIENT TEMPERATURE. b) HEATING - 40ºC / 45ºC ENTERING / LEAVING EVAPORATOR ATER TEMPERATURE, 7ºC AIR AMBIENT TEMPERATURE. 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELO THE UNIT. S3

Mini Chiller Specifications M4AC080C - M4AC150C (Cooling Only, R407C) M4AC080C M4AC100C M4AC120C M4AC150C NOMIL COOLING CAPACITY NOMIL TOTAL INPUT POER 74000 88000 115000 13700 21688 25791 33705 40152 9463 10771 11805 14531 POER SOURCE REFRIGERANT TYPE CONTROL V/Ph/Hz 380-415 / 3 / 50 R22 TXV 1245 / 49.0 UNIT DIMENSION IDTH 1500 / 59.1 1800 / 70.9 900 / 35.4 1150 / 45.3 UNIT EIGHT SOUND PRESSURE LEVEL kg/lb 340 / 750 350 / 772 460 / 1014 540 / 1190 dba 65 66 67 69 EVAPORATOR NOMIL ATER FLO HYDRAULIC KIT l/s/m 3 /hr 1.08 / 3.9 1.31 / 4.7 1.67 / 6.0 2.00 / 7.2 PUMP PIPING MAX. ATER OPER. PRESSURE ATER FLO RATE INSTALLATION PIPE CONNECITON HEAD 1000 / 145 l/s/m 3 /hr 1.08 / 3.9 1.31 / 4.7 1.67 / 6.0 2.00 / 7.2 42 / 1 1/4" m 26.0 23.5 25.0 23.0 MATERIAL TANK CAPACITY/VOLUME COMPRESSOR STAGE OF CAPACITY CONTROL () L/ft 3 0-50 - 100% M4AC080CR - M4AC150CR (Heatpump, R407C) M4AC080CR M4AC100CR M4AC120CR M4AC150CR NOMIL COOLING CAPACITY NOMIL HEATING CAPACITY NOMIL TOTAL INPUT POER POER SOURCE REFRIGERANT TYPE CONTROL UNIT DIMENSION UNIT EIGHT SOUND PRESSURE LEVEL EVAPORATOR NOMIL ATER FLO HYDRAULIC KIT PUMP PIPING TANK MAX. ATER OPER. PRESSURE ATER FLO RATE INSTALLATION PIPE CONNECITON HEAD COMPRESSOR MATERIAL CAPACITY/VOLUME STAGE OF CAPACITY CONTROL () 74000 88000 110000 130000 21688 25791 32239 38101 90000 98000 118000 144000 26377 28722 34583 42204 COOLING 9946 11028 12273 15151 HEATING 9975 11134 12386 15824 IDTH V/Ph/Hz Notes: 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253. 3) NOMIL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELO : a) COOLING - 12ºC / 7ºC ENTERING / LEAVING EVAPORATOR ATER TEMPERATURE, 35ºC AIR AMBIENT TEMPERATURE. b) HEATING - 40ºC / 45ºC ENTERING / LEAVING EVAPORATOR ATER TEMPERATURE, 7ºC AIR AMBIENT TEMPERATURE. 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELO THE UNIT. kg/lb 340 / 750 350 / 772 460 / 1014 540 / 1190 dba 65 66 67 69 COOLING l/s/m 3 /hr 1.08 / 3.9 1.31 / 4.7 1.67 / 6.0 2.00 / 7.2 HEATING l/s/m 3 /hr 1.14 / 4.1 1.37 / 4.9 1.79 / 6.4 2.10 / 7.6 COOLING l/s/m 3 /hr 1.08 / 3.9 1.31 / 4.7 1.67 / 6.0 2.00 / 7.2 HEATING l/s/m 3 /hr 1.14 / 4.1 1.37 / 4.9 1.79 / 6.4 2.10 / 7.6 COOLING m 26.0 23.5 25.0 23.0 HEATING m 25.0 22.5 24.5 22.5 L/ft 3 1500 / 59.1 900 / 35.4 380-415 / 3 / 50 R22 TXV 1245 / 49.0 1000 / 145 42 / 1 1/4" 0-50 - 100% 1800 / 70.9 1150 / 45.3 S4

Mini Chiller Specifications M5AC020CR - M5AC055CR (Heatpump, R410A) M5AC020CR M5AC025CR M5AC030CR M5AC040CR M5AC050CR M5AC055CR NOMIL COOLING CAPACITY 17000 4980 21000 6150 26800 7848 37500 10981 47000 13763 50000 14641 NOMIL HEATING CAPACITY 21500 6300 25000 7330 32500 9517 40800 11947 51000 14934 55000 16105 NOMIL TOTAL INPUT POER COOLING HEATING 2550 2590 2760 2790 3720 3630 4330 4490 5090 5130 5890 5990 POER SOURCE V/Ph/Hz 220-240 / 1 / 50 220-240 / 1 / 50 or 380-415 / 3 / 50 REFRIGERANT TYPE R410A CONTROL CAPILLARY TUBE CAPILLARY TUBE & TXV UNIT DIMENSION UNIT EIGHT IDTH kg/lb 800 / 31.5 1160 / 45.7 460 / 18.1 125 / 276 165 / 364 790 / 31.1 1010 / 39.8 460 / 18.1 125 / 276 1410 / 55.5 1010 / 39.8 460 / 18.1 165 / 364 167 / 368 1410 / 55.5 1010 / 39.8 460 / 18.1 173 / 381 SOUND PRESSURE LEVEL dba 57 57 58 60 60 60 EVAPORATOR NOMIL ATER FLO COOLING HEATING l/s/m 3 /hr l/s/m 3 /hr 0.23 / 0.84 0.32 / 1.16 0.28 / 1.00 0.35 / 1.25 0.42 / 1.5 0.42 / 1.5 0.53 / 1.9 0.53 / 1.9 0.64 / 2.3 0.64 / 2.3 0.72 / 2.6 0.72 / 2.6 HYDRAULIC KIT MAX. ATER OPER. PRESSURE 1000 / 145 PUMP COOLING ATER FLO RATE HEATING INSTALLATION PIPE CONNECITON l/s/m 3 /hr l/s/m 3 /hr 0.23 / 0.84 0.32 / 1.16 0.28 / 1.00 0.35 / 1.25 0.42 / 1.5 25.4 / 1 0.53 / 1.9 0.64 / 2.3 0.72 / 2.6 PIPING HEAD COOLING HEATING m m 8.7 7.7 10.1 9.3 9.0 7.7 10.0 8.9 7.9 6.4 7.9 5.7 TANK MATERIAL CAPACITY/VOLUME L/ft 3 CAST IRON / STAINLESS STEEL 22 / 0.78 COMPRESSOR STAGE OF CAPACITY CONTROL () 0-100% 0-50 - 100% 0-40 - 60-100% 0-50 - 100% M5ACV030CR - M5ACV135CR (Inverter Heatpump, R410A) M5ACV030CR M5ACV055CR M5ACV075CR M5ACV100CR M5ACV135CR M5ACV210CR NOMIL COOLING CAPACITY 27000 7913 50000 14654 70000 20515 95000 27800 131500 38540 200000 58617 NOMIL HEATING CAPACITY 33000 9663 55000 16119 75000 21980 100000 29300 141500 41470 210000 61548 NOMIL TOTAL INPUT POER COOLING HEATING 5279 4418 7600 6100 9050 7900 12000 11400 15750 16250 22300 21800 POER SOURCE V/Ph/Hz 220-240 / 1 / 50 380-415 / 3 / 50 REFRIGERANT TYPE R410A CONTROL ELECTRONIC EXPANSION VALVE (EXV) EXV / CAPILLARY TUBE EXV / CAPILLARY TUBE UNIT DIMENSION UNIT EIGHT IDTH kg/lb 790 / 31.1 1010 / 39.8 460 / 18.1 128 / 282 1410 / 55.5 1010 / 39.8 460 / 18.1 195 / 430 1460 / 57.5 1150 / 45.3 550 / 21.7 200 / 440 1260 / 49.6 1500 / 59.1 900 / 35.4 360 / 794 1260 / 49.6 1800 / 70.9 1150 / 45.3 560 / 1235 1786 / 70.31 2093 / 82.4 1192 / 46.9 682 SOUND PRESSURE LEVEL dba 59 62 65 63 67 85 EVAPORATOR NOMIL ATER FLO COOLING HEATING l/s/m 3 /hr l/s/m 3 /hr 0.3 ( 1.3 ) 0.4 ( 1.5 ) 0.7 ( 2.5 ) 0.8 ( 2.7 ) 0.9 ( 3.4 ) 1.0 ( 3.7 ) 1.3 ( 4.8 ) 1.4 ( 5.0 ) 1.8 ( 6.6 ) 2.0 ( 7.1 ) 2.67 (9.8) 2.86 (10.5) HYDRAULIC KIT MAX. ATER OPER. PRESSURE 1000 / 145 COOLING ATER FLO RATE HEATING INSTALLATION PIPE CONNECITON l/s/m 3 /hr l/s/m 3 /hr 0.3 ( 1.3 ) 0.4 ( 1.5 ) 0.7 ( 2.5 ) 0.8 ( 2.7 ) 0.9 ( 3.4 ) 1.0 ( 3.7 ) 25.4 / 1 1.3 ( 4.8 ) 1.4 ( 5.0 ) 1.8 ( 6.6 ) 2.0 ( 7.1 ) 2.7 (9.6) 2.9 (10.3) 38.0 / 1.5 PIPING HEAD COOLING HEATING m m 7.7 7.0 12.7 11.5 22.3 21.3 17.3 15.7 16.5 14.5 25 25 TANK MATERIAL CAPACITY/VOLUME L/ft 3 COMPRESSOR STAGE OF CAPACITY CONTROL () 0-28700 0-55000 0-75000 73000-122000 99000-149000 73000-220000 Notes: 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253. 3) NOMIL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELO : a) COOLING - 12ºC / 7ºC ENTERING / LEAVING EVAPORATOR ATER TEMPERATURE, 35ºC AIR AMBIENT TEMPERATURE. b) HEATING - 40ºC / 45ºC ENTERING / LEAVING EVAPORATOR ATER TEMPERATURE, 7ºC AIR AMBIENT TEMPERATURE. 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELO THE UNIT. S5

Chilled ater Fan Coil Unit Specifications MCK020A - MCK050A (Ceilling Cassette A Series) MCK020A MCK025A MCK030A MCK040A MCK050A NOMIL TOTAL COOLING CAPACITY 24000 25600 29500 7027 7496 8638 35000 10248 40000 11712 NOMIL SENSIBLE COOLING CAPACITY 17800 18800 21600 5212 5505 6324 25500 7466 29600 8667 NOMIL TOTAL HEATING CAPACITY (ENTERING ATER TEMP. = 70ºC) 48000 50000 58000 14054 14640 16982 64500 18886 67000 19618 HIGH 349 / 740 368 / 780 415 / 880 467 / 990 491 / 1040 NOMIL AIR FLO MEDIUM 297 / 630 312 / 660 349 / 740 406 / 860 448 / 950 LO 283 / 600 283 / 600 321 / 680 359 / 760 411 / 870 335 / 13.2 ( 363 / 14.3 ) UNIT DIMENSION - ( ) ITH PANEL IDTH 820 / 32.3 ( 930 / 36.6 ) 821 / 32.3 ( 930 / 36.6 ) UNIT EIGHT ( UNIT + PANEL ) kg/lb ( 31+4 ) / ( 1.2+0.2 ) ( 32+4 ) / ( 1.3+0.2 ) ( 35+4 ) / ( 1.4+0.2 ) ( 38+4 ) / ( 1.5+0.2 ) ( 40+4 ) / ( 1.6+0.2 ) SOUND PRESSURE LEVEL ( H/M/L ) dba 42 / 39 / 37 45 / 42 / 40 49 / 45 / 43 51 / 48 / 46 53 / 52 / 50 NOMIL ATER FLO RATE USGPM LITRES/M 5.20 5.80 6.70 19.68 21.96 25.36 7.30 27.63 7.50 28.39 HEAD LOSS (COOLING) 19.44 / 2.82 23.58 / 3.42 30.47 / 4.42 35.44 / 5.14 37.16 / 5.39 HEAD LOSS (HEATING) : 70ºC 15.17 / 2.20 18.48 / 2.68 24.27 / 3.52 28.41 / 4.12 29.85 / 4.33 CONNECTION 3/4" BSP FEMALE UNION MCK020AH - MCK050AH (4 Pipies Ceilling Cassette) MCK020AH MCK025AH MCK030AH MCK040AH MCK050AH NOMIL TOTAL COOLING CAPACITY 13000 13500 15800 3806 3953 4626 17100 5007 17600 5153 NOMIL SENSIBLE COOLING CAPACITY 11600 12000 13900 3396 3514 4070 15000 4392 15500 4538 NOMIL TOTAL HEATING CAPACITY (ENTERING ATER TEMP. = 70ºC) 33300 34300 39300 9750 10043 11507 42150 12342 43500 12737 HIGH 349 / 740 368 / 780 415 / 880 467 / 990 491 / 1040 NOMIL AIR FLO MEDIUM 297 / 630 312 / 660 349 / 740 406 / 860 448 / 950 LO 283 / 600 283 / 600 321 / 680 359 / 760 411 / 870 335 / 13.2 ( 363 / 14.3 ) UNIT DIMENSION - ( ) ITH PANEL IDTH 820 / 32.3 ( 930 / 36.6 ) 821 / 32.3 ( 930 / 36.6 ) UNIT EIGHT ( UNIT + PANEL ) kg/lb ( 31+4 ) / ( 1.2+0.2 ) ( 32+4 ) / ( 1.3+0.2 ) ( 35+4 ) / ( 1.4+0.2 ) ( 38+4 ) / ( 1.5+0.2 ) ( 40+4 ) / ( 1.6+0.2 ) SOUND PRESSURE LEVEL ( H/M/L ) dba 42 / 39 / 37 45 / 42 / 40 49 / 45 / 43 51 / 48 / 46 53 / 52 / 50 NOMIL ATER FLO RATE USGPM LITRES/M 2.90 3.00 3.50 10.98 11.36 13.25 3.80 14.39 3.90 14.76 HEAD LOSS (COOLING) 3.56 / 0.52 3.78 / 0.55 4.94 / 0.72 35.44 / 5.14 37.16 / 5.39 HEAD LOSS (HEATING) : 70ºC 4.76 / 0.69 5.45 / 0.79 7.17 / 1.04 28.41 / 4.12 29.85 / 4.33 CONNECTION 3/4" BSP FEMALE UNION Notes: 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253. 3) NOMIL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELO : a) COOLING - ENTERING AIR TEMP. : 27ºC (80.6ºF) DB / 19ºC (66.2ºF) B, ENTERING ATER TEMP. : 7ºC (44.6ºF), LEAVING ATER TEMP. : 12ºC (53.6ºF) b) HEATING - ENTERING AIR TEMP.: 20ºC (68ºF) DB, ENTERING ATER TEMP. : 70ºC (158ºF), LEAVING ATER TEMP. : 65ºC (149ºF) 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. MCK020/025A/AH : POSITION OF THE MEASUREMENT POINT IS 1.4m BELO THE FACIA. MCK030/040/050A/AH : 1.5m BELO THE FACIA (JIS B 8615). S6