rpsa FIRE PROTECTION ENGINEERS

Similar documents
Interfacing Fire Alarm, Sprinkler and Elevator Systems

MD-DC-VA Automatic Fire Alarm Association, Inc. Interfacing Fire Alarm, Sprinkler and Elevator Systems In Maryland, DC and Virginia

NFPA Changes

ELEVATORS. Integration of Codes between Fire Alarm, Sprinklers, and Elevators 12/5/2017

Presentation Material: The material will be presented in a PowerPoint format and available digitally/ paper.

El Reno Fire Department Fire Alarm Plan Review Worksheet

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

The Owner will provide the QEI inspection and certification services.

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

APPENDIX K MODIFIED INDUSTRY STANDARDS FOR ELEVATORS AND CONVEYING SYSTEMS

Fire Alarm System Fundamentals

Division 28 - Electronic Safety and Security

Changes in NFPA

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Agency for Health Care Administration

9/23/ :47 AM. Second Revision No NFPA [ New Section after ] Submitter Information Verification. Committee Statement

Fire Protection Coffee Break Training May 2016

A17 Standards Committee Interpretations Volume 3

SECTION 907 FIRE ALARM AND DETECTION SYSTEMS

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting. Prepared Especially for : OSFM TEC 2016

HIGH-RISE RETROFIT ORDINANCES - NO and NO

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018

First Revision No. 158-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

Florida Building Code 2010

Chapter 17, Initiating Devices

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

Port of Portland Conveying Equipment Guidelines

Agency for Health Care Administration

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

2012 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

ELEVATORS AND FIRE ALARM SYSTEM INTERFACES CANADIANFIRE ALARM ASSOCIATION 2011 ONTARIO ANNUAL TECHNICAL SEMINAR

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES

Bold items are particular to the City of Euless

2018 NICET Code Transition Changes

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

FIRE SAFETY REQUIREMENTS FOR PRE RESIDENTIAL BUILDINGS OF THREE OR MORE STORIES (DOROTHY MAE ORDINANCE - NO. 158,963)

Agency for Health Care Administration

Idaho Surveying & Rating Bureau, Inc South Cobalt Point Way Tel: (208) Meridian, Idaho FAX: (208)

Report on First Revisions with Statement June 2014 NFPA 101

Elevator Emergency Equipment Instructor s Guide

780 CMR: STATE BOARD OF BUILDING REGULATIONS AND STANDARDS

26 of 128 9/23/2014 9:25 AM

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

FIRE & LIFE SAFTEY STANDARD

1 Exam Prep Fire Alarm Signaling Systems Tabs and Highlights

Emergency Power & Fire Service Checklist

Chapter 4: Fire Protection Systems

The Residences at Christina Landing Wilmington, DE

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

C. None (No sprinkler system) K3 E. NUMBER OF BEDS CERTIFIED FOR MEDICAID

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

Full Service Central Station Fire Alarm Listing Evaluation

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

Unified Fire Authority - Fire Prevention Bureau

New Facilities. Minimum Requirements

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

Agency for Health Care Administration

NEW YORK CITY DEPARTMENT OF BUILDINGS. Notice of Public Hearing and Opportunity to Comment on Proposed Rule

ICC CODE CORNER 2012 IFC Code & Commentary

Fire Alarm, Water Flow Alarm & Signaling Systems

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

Releasing Systems. Rob Mennie Senior Consultant Gage-Babcock & Associates Ltd.

THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS.

Maintaining Building and Fire Safety During Active Assailant Events and Other Terrorist Events

Fire Pump Supervision - Part 2 by Dean K. Wilson, P.E.

FIRE SAFETY PLAN. Ceramics/Sculpture Building 47 Service Rd 1 S Winnipeg, MANITOBA. May / Prepared by: Chris Pancoe

CITY OF PASADENA FIRE DEPARTMENT

PROJECT MANUAL PART II TECHNICAL PROVISIONS. Concourse B Fire Alarm Replacement CONTRACT NO Issued for Bid January 13, 2016

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

DUCT SYSTEMS CHAPTER 6

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

Operation & Maintenance Manual

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

Recommended Amendments to the 2003 International Fire Code North Central Texas Council of Governments region

Report on First Revisions with Statement June 2014 NFPA 101

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

FEO Initiation Devices Dean McLellan

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

NFPA 72 Code Changes vs 2013

Table EXIT ACCESS TRAVEL DISTANCE a OCCUPANCY SYSTEM SYSTEM. A, E, F-1, I-1, M, b,d R, S-1. B c. F-2, S-2, U c

Defend In Place 2012 IFC Overview of Institutional Occupancies

Prepublication New Text Jan 2018 Changes to Environment of Care and Life Safety Chapters

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES

Fire Alarm and Life Safety System Inspection Certificate

SECTION WET-PIPE SPRINKLER SYSTEMS

PERFORMANCE COMPLIANCE METHODS

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number:

Transcription:

FIRE PROTECTION ENGINEERS R.P. SCHIFILITI ASSOCIATES, INC. P.O. Box 297 Reading, Massachusetts 01867-0497 USA 781.944.9300 Fax / Data 781.942.7500 Telephone Elevator Fire Safety: Elevator Recall and Elevator Power Shutdown Background Elevators are an extremely safe mode of transportation. If code compliant, elevators and the hoistways and associated machine rooms do not add any significant fire load. The only significant fire risk that they add is the possible transport of smoke and the possible entrapment of users. For this reason codes specify fire safety features to reduce the likelihood of smoke migration and to control elevators when they are threatened with fire or smoke. The codes recognize that there is almost no risk of fire in a code compliant elevator or hoistway that would be mitigated by protection being required in those spaces. Therefore, building codes, fire codes, elevator safety codes and sprinkler and fire alarm standards have been coordinated to not require any special protection in properly constructed hoistways. The exception (see NFPA 13 below) is if a hydraulic elevator uses a combustible fluid. Several years ago I participated in a joint effort sponsored by ASME to address elevator fire safety and to coordinate ASME A17.1, building codes, NFPA 101 Life Safety Code, NFPA 13 Standard for the Installation of Sprinkler Systems and NFPA 72 National Fire Alarm Code. The task group included elevator safety experts, fire protection engineers, fire alarm and sprinkler experts, fire fighters, code experts and others. This work resulted in requirements that are now in place. Summary There is no need and no code requirement to sprinkler an elevator hoistway unless the hoistway or the elevator car fail to meet the non-combustibility requirements that they are required to meet. The exception (see NFPA 13 below) is if a hydraulic elevator uses a combustible fluid. There is no need and no code requirement to put a smoke detector in an elevator hoistway unless it has sprinklers. If a hoistway has sprinklers at the top, a smoke detector is needed, and required by code, to recall and safely park the elevator. If a hoistway has sprinklers at the top, a heat detector or flow switch without any time delay mechanism is needed, and required by code, to shunt power before or at the instant water is discharged. Where sprinklers are provided or required in a building by another code, elevator lobbies and elevator machine rooms are required to have them for complete coverage. If a machine rooms has sprinklers, smoke detection is needed, and required by code, to recall and safely park the elevator. If a machine rooms has sprinklers, heat detection or a flow switch without any time delay mechanism is needed, and required by code, to shunt power before or at the instant water is discharged. File: elevator recall-shutdown rev 2.doc Page 1 4 March 2000

There is no need and no code requirement to recall or control elevators unless the shaft or machine room are threatened. Thus, the codes work together to require elevator recall only when smoke detectors in the following areas are activated: 1) elevator lobbies, 2) elevator machine rooms, or 3) if provided per the above, elevator hoistways. Disclaimer: The following code excerpts are current as of this writing. Local codes or amendments may change these requirements. The opinions stated above are those of R.P. Schifiliti Associates, Inc. and are generalizations that may not apply to your specific situation. Excerpts from: ASME/ANSI A17.1, Safety Code for Elevators and Escalators, 1993 211.3b Smoke Detectors. System-type smoke detectors conforming to the requirements of UL 268 shall be installed in each elevator lobby and associated machine room in accordance with NFPA 72, Chapter 3. Smoke detectors are not required in elevator lobbies at unenclosed landings. System-type smoke detectors shall be permitted to be installed in any hoistway and shall be installed in hoistways which are sprinklered (see Rule 102.2). (1) The activation of a smoke detector in any elevator lobby, other than at the designated level, shall cause all cars that serve that lobby to return nonstop to the designated level. The activation of a smoke detector in any elevator hoistway shall cause all elevators having any equipment located in the hoistway, and any associated elevators of a group automatic operation, to return nonstop to the designated level, except that smoke detectors in hoistways installed at or below the lowest landing of recall, when activated, shall cause the car the car to be sent to the upper level of recall. The operation shall conform to the requirements of Rule 211.3a. (2) When the smoke detector at the designated level is activated, the operation shall conform to the requirements of Rule 211.3a, except that the cars shall return to an alternate level approved by the enforcing authority, unless the designated-level three-position Phase I switch (Rule 211.3a) is in the "ON" position. (3) The activation of a smoke detector in any elevator machine room, except a machine room at the designated level, shall cause all elevators having any equipment located in that machine room, and any associated elevators of a group automatic operation, to return nonstop to the designated level. The activations of a smoke detector in any elevator machine room at the designated level shall cause all elevators having any equipment located in that machine room, and any associated elevators of a group automatic operation, to return nonstop to the alternate level, or the appointed level when approved by the authority having jurisdiction. (4) Elevators shall only react to the first smoke detector zone which is activated for that group. (5) Phase I operation, when initiated by a smoke detector, shall be maintained until canceled by moving the Phase I switch to the "BYPASS" position [see also Rule 211.3a(10)]. Smoke detectors and/or smoke detector systems shall not be self-resetting. NOTE (Rule 211.3b): In buildings with fire alarm systems, see NFPA 72A for additional information. File: elevator recall-shutdown rev 2.doc Page 2 4 March 2000 FIRE PROTECTION ENGINEERS

Excerpts from: NFPA 13, Standard for the Installation of Sprinkler Systems, 1999 5-13.6 Elevator Hoistways and Machine Rooms. 5-13.6.1* Sidewall spray sprinklers shall be installed at the bottom of each elevator hoistway not more than 2 ft (0.61 m) above the floor of the pit. Exception: For enclosed, noncombustible elevator shafts that do not contain combustible hydraulic fluids, the sprinklers at the bottom of the shaft are not required. 5-13.6.2* Automatic sprinklers in elevator machine rooms or at the tops of hoistways shall be of ordinary- or intermediate-temperature rating. 5-13.6.3* Upright or pendent spray sprinklers shall be installed at the top of elevator hoistways. Exception: Sprinklers are not required at the tops of noncombustible hoistways of passenger elevators with car enclosure materials that meet the requirements of ASME A17.1, Safety Code for Elevators and Escalators. A-5-13.6.1 The sprinklers in the pit are intended to protect against fires cause by debris, which can accumulate over time. Ideally, the sprinklers should be located near the side of the pit below the elevator doors, where most debris accumulates. However, care should be taken that the sprinkler location does not interfere with the elevator toe guard, which extends below the face of the door opening. ASME A17.1, Safety Code for Elevators and Escalators, allows the sprinklers within 2 ft (0.65 m) of the bottom of the pit to be exempted from the special arrangements of inhibiting waterflow until elevator recall has occurred. A-5-13.6.2 ASME A17.1, Safety Code for Elevators and Escalators, requires the shutdown of power to the elevator upon or prior to the application of water in elevator machine rooms or hoistways. This shutdown can be accomplished by a detection system with sufficient sensitivity that operates prior to the activation of the sprinklers (see also NFPA 72, National Fire Alarm Code ). As an alternative, the system can be arranged using devices or sprinklers capable of effecting power shutdown immediately upon sprinkler activation, such as a waterflow switch without a time delay. This alternative arrangement is intended to interrupt power before significant sprinkler discharge. A-5-13.6.3 Passenger elevator cars that have been constructed in accordance with ASME A17.1, Safety Code for Elevators and Escalators, Rule 204.2a (under A17.1a-1985 and later editions of the code) have limited combustibility. Materials exposed to the interior of the car and the hoistway, in their end-use composition, are limited to a flame spread rating of 0 to 75 and a smoke development rating of 0 to 450. File: elevator recall-shutdown rev 2.doc Page 3 4 March 2000 FIRE PROTECTION ENGINEERS

Excerpts from: NFPA 72, National Fire Alarm Code, 1999 3-9.3 Elevator Recall for Fire Fighters Service. 3-9.3.1* System-type smoke detectors located in elevator lobbies, elevator hoistways, and elevator machine rooms used to initiate fire fighters service recall shall be connected to the building fire alarm system. In facilities without a building fire alarm system, these smoke detectors shall be connected to a dedicated fire alarm system control unit that shall be designated as elevator recall control and supervisory panel, permanently identified on the control unit and on the record drawings. Unless otherwise required by the authority having jurisdiction, only the elevator lobby, elevator hoistway, and the elevator machine room smoke detectors shall be used to recall elevators for fire fighters service. 3-9.3.2 Each elevator lobby, elevator hoistway, and elevator machine room smoke detector shall be capable of initiating elevator recall when all other devices on the same initiating device circuit have been manually or automatically placed in the alarm condition. 3-9.3.3 A lobby smoke detector shall be located on the ceiling within 21 ft (6.4 m) of the centerline of each elevator door within the elevator bank under control of the detector. Exception: For lobby ceiling configurations exceeding 15 ft (4.6 m) in height or that are other than flat and smooth, detector locations shall be determined in accordance with Chapter 2. 3-9.3.4 Smoke detectors shall not be installed in elevator hoistways. Exception No. 1: Where the top of the elevator hoistway is protected by automatic sprinklers. Exception No. 2: Where a smoke detector is installed to activate the elevator hoistway smoke relief equipment. 3-9.3.5 If ambient conditions prohibit installation of automatic smoke detection, other automatic fire detection shall be permitted. 3-9.3.6 When actuated, each elevator lobby, elevator hoistway, and elevator machine room smoke detector shall initiate an alarm condition on the building fire alarm system and shall visibly indicate, at the control unit and required remote annunciators, the alarm initiation circuit or zone from which the alarm originated. Actuation from elevator hoistway and elevator machine room smoke detectors shall cause separate and distinct visible annunciation at the control unit and required annunciators to alert fire fighters and other emergency personnel that the elevators are no longer safe to use. Actuation of these detectors shall not be required to actuate the system notification appliances where the alarm signal is indicated at a constantly attended location. Exception: If approved by the authority having jurisdiction, the elevator hoistway and machine room smoke detectors shall be permitted to initiate a supervisory signal. 3-9.3.7* For each group of elevators within a building, three separate elevator control circuits shall be terminated at the designated elevator controller within the group s elevator machine room(s). The operation of the elevators shall be in accordance with Rules 211.3 through 211.8 of ANSI/ASME File: elevator recall-shutdown rev 2.doc Page 4 4 March 2000 FIRE PROTECTION ENGINEERS

A17.1, Safety Code for Elevators and Escalators. The smoke detectors shall actuate the three elevator control circuits as follows: (a) The smoke detector located in the designated elevator recall lobby shall actuate the first elevator control circuit. In addition, if the elevator is equipped with front and rear doors, the smoke detectors in both lobbies at the designated level shall actuate the first elevator control circuit. (b) The smoke detectors in the remaining elevator lobbies shall actuate the second elevator control circuit. (c) The smoke detectors in elevator hoistways and the elevator machine room(s) shall actuate the third elevator control circuit. In addition, if the elevator machine room is located at the designated level, its smoke detector shall also actuate the first elevator control circuit. 3-9.4 Elevator Shutdown. 3-9.4.1* Where heat detectors are used to shut down elevator power prior to sprinkler operation, the detector shall have both a lower temperature rating and a higher sensitivity as compared to the sprinkler. 3-9.4.2 If heat detectors are used to shut down elevator power prior to sprinkler operation, they shall be placed within 2 ft (610 mm) of each sprinkler head and be installed in accordance with the requirements of Chapter 2. Alternatively, engineering methods, such as specified in Appendix B, shall be permitted to be used to select and place heat detectors to ensure response prior to any sprinkler head operation under a variety of fire growth rate scenarios. 3-9.4.3* If pressure or waterflow switches are used to shut down elevator power immediately upon or prior to the discharge of water from sprinklers, the use of devices with time delay switches or time delay capability shall not be permitted. 3-9.4.4* Control circuits to shut down elevator power shall be monitored for presence of operating voltage. Loss of voltage to the control circuit for the disconnecting means shall cause a supervisory signal to be indicated at the control unit and required remote annunciators. A-3-9.3.1 In facilities without a building alarm system, dedicated fire alarm system control units are required by 3-9.3.1 for elevator recall in order that the elevator recall systems be monitored for integrity and have primary and secondary power meeting the requirements of this code. The control unit used for this purpose should be located in an area that is normally occupied and should have audible and visible indicators to annunciate supervisory (elevator recall) and trouble conditions; however, no form of general occupant notification or evacuation signal is required or intended by 3-9.3.1. A-3-9.4.1 A lower response time index is intended to provide detector response prior to the sprinkler response, because a lower temperature rating alone might not provide earlier response. The listed spacing rating of the heat detector should be 25 ft (7.6 m) or greater. A-3-9.4.3 Care should be taken to ensure that elevator power cannot be interrupted due to water pressure surges in the sprinkler system. The intent of the code is to ensure that the switch and the system as a whole do not have the capability of introducing a time delay into the sequence. The use of a switch with a time delay mechanism set to zero does not meet the intent of the code, because it is possible File: elevator recall-shutdown rev 2.doc Page 5 4 March 2000 FIRE PROTECTION ENGINEERS

to introduce a time delay after the system has been accepted. This might occur in response to unwanted alarms caused by surges or water movement, rather than addressing the underlying cause of the surges or water movement (often due to air in the piping). Permanently disabling the delay in accordance with the manufacturer s printed instructions should be considered acceptable. Systems that have software that can introduce a delay in the sequence should be programmed to require a security password to make such a change. File: elevator recall-shutdown rev 2.doc Page 6 4 March 2000 FIRE PROTECTION ENGINEERS