ASPIRATING SMOKE DETECTION SYSTEMS

Similar documents
ASPIRATING SMOKE DETECTION SYSTEMS

ANCILLARY DEVICES. Contents. Fire System Document Box. EN54-4 Approved Power Supply Units. Transformer Rectifier 24v Door Retainer Power Supply Units

ANALOGUE FIRE DETECTION SENTRI SYSTEM

CONVENTIONAL FIRE DETECTION

by Honeywell THE VIGILON SYSTEM BROCHURE

Fire Alarm Panel - User Manual

FAAST. Fire Alarm Aspirating Sensing Technology

SECTION 6: page. by Honeywell. Section 6: Vigilon Loop Devices

FAAST. Fire Alarm Aspirating Sensing Technology

SKYSTAR water cassette Main components:

BC80A compact product catalog.

DC Disconnect with remote control and arc fault detection PVREM-...-AF1

SenTRI ONE CONTROL PANEL

Nexus 1-8 Loop (A1557) Analogue Addressable Control Panel Application Guide

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

HAZARDOUS AREA. The very best in high pressure water jetting systems SURFACE PREPARATION/ COATING REMOVAL PIPE CLEANING HEAT EXCHANGER CLEANING

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

Take control with... Energy Efficient Controls

ARG 1

AUTOMATIC MARINE AND RV TOILETS

VRV IV S-series HEAT PUMP SYSTEMS LIGHT COMMERCIAL / RESIDENTIAL

DESIGN AND APPLICATION GUIDE VISUAL ALARMS

FAAST PRODUCT RANGE Aspirating Smoke Detection

Machinery Space Fire Protection System from an Approved Product Portfolio

FAAST. Fire Alarm Aspiration Sensing Technology

Small is beautiful and useful anywhere... Electric "Point of Use" Water Heaters "Open-Outlet" for single outlet "Unvented" for one or more outlets

Clean and simple waste water removal

MYSON ELECTRIC UNDERFLOOR HEATING. INSTALLATION MANUAL. heatingthroughinnovation. APRIL 2013

iii. Compatible Loop Devices and Panel Responses 27 IMPORTANT NOTE: Read the instructions carefully before commencing installation and commissioning.

VRV AURORA AIR-COOLED SYSTEMS

ELECTRIC UNDERFLOOR HEATING

DETERGENT & RINSE AID INJECTION

Mica insulated band heaters

Commercial Upright Vacuums

Buderus. Quality Doesn t Cost It Saves! Comfortable. Efficient. Intelligent Heating. GA124 GA244 Gas Boilers Sealed Combustion Draft Induced.

VRV T-Series WATER-COOLED SYSTEMS 10.17

EPLE Air-Cooled. Chillers. EUWA*5-24KZ / EUWY*5-24KZ Hydronic systems

Mica insulated flat heaters

Multi-layered Intrusion Detection

Ceramic insulated band heaters

Operating Instructions OPTISWITCH 3100 C with transistor output

List of Contents Air Top 2000 NOTE

Hybrid Flex Inverter System Dual, Tri and Quad Zone Mix & Match Flexibility. Use mini-splits just about any place that requires comfort!

Our home standard. Your home is where our heart is...

Electrorad Digi-Line. Installation, Operating & Instruction Manual. After Sales Service:

PRODUCT CATALOG MEDICAL AUTOCLAVE.

Operating Instructions OPTISWITCH 3100 C with contactless electronic switch

Critical Environments Case Study Library. Cover Photo courtesy of Bruce T. Martin 2011

Classic ECO. Eco Series -86 C Ultra-low Freezer KM-DU34H1E

UALITY ONTROL. Thermal processing equipment for laboratories

Undercounter Dishwasher

General terms and conditions... F-7 Glossary of terms... P.1455~ panasonic.net/id/pidsx/global

Motion & Presence Detectors

ORDER GUIDE. 5 m ft cable length type. Accessories. Robust Photoelectric Sensor RX SERIES

Take control with... 1

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

Forest help when you need it To order or for more information visit or call

ASPIRATING SMOKE DETECTION SYSTEMS

Dynacon Eclipse. Floor Heating Manifolds Floor heating manifold with automatic flow control

water-cooled CHILLERS

PRODUCT CATALOG MEDICAL REFRIGERATOR. LABSTAC LTD, Kemp House, 152 City Road, London EC1V 2NX, United Kingdom. labstac.

Thermo shaker PHMP/ PHMP-4

Operating Instructions KSR-TF 611 with transistor output

solo A complete range of test and maintenance equipment for smoke, heat and CO detectors. detectortesters Solo 330 Aerosol Dispenser

Inspired LED Emergency Lighting Solutions

Think FATI for Hot Solutions

solo A complete range of test and maintenance equipment for smoke, heat and CO detectors. detectortesters Solo 330 Aerosol Dispenser

Thermo shaker PHMP/ PHMP-4

Undercounter Dishwasher

Operating Instructions KSR-TF 633 with transistor output

Underc Dishwasher. IMPORTANT: Read and save these instryctions. 8

Mynute Boiler Standard-Efficiency Wall-Hung Boilers with tank

1.1 SCOPE 1.2 APPROVALS. A. The Aspirating Smoke Detector shall be tested, approved and/or listed by: 1.3 CODE, STANDARDS, AND REGULATION

Operating Instructions OPTISWITCH 3100 C with contactless electronic switch

Aspir A ation spir P R O D U C T S

THE WALL-MOUNT TM QUIET CLIMATE HEAT PUMPS. Green Refrigerant

SSimdex and Power-Limited Fire Alarm Systems Operating and Installation Instructions

30 and 36 m Sealed Burner

Operating Instructions OPTISWITCH 5100 C, 5150 C with transistor output

Code Accessories HUB RADIATOR HRC. mod. Connection BUS mod.

Code Accessories HUB RADIATOR PACK. First start from 1 to 2 HR booster

FWPC/FWPS/FWS/FWP EQUIPMENT PLATE EXCHANGERS FOR INSTANTANEOUS DOMESTIC HOT WATER PRODUCTION IN BLOCK OF FLATS CONDITIONS OF USE

Mini-Split Air Conditioners and Heat Pumps

INDIA S MOST POWER SAVING INVERTER AC

We see cooking not as a chore, but a creative act. As more of our lives become virtual and people look for ways to make and create things, we design

Royal Sovereign Brochure

FAAST Beyond Standard Methods of Detection

LASER Fan Coil Unit. 2 & 4 pipe system A complete range from 1.1 kw up to 9.9 kw. Thermostats

Operating Instructions OPTISWITCH 5200 C, 5250 C with NAMUR output

Smarts Ali47. Aluminium Windows

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

Excel-EN Conventional Fire Control Panel

ACZC GENERAL CHARACTERISTICS VERSIONS OPTIONS ON REQUEST STANDARD OPTIONS AIR COOLED CHILLER WITH SCROLL COMPRESSORS. Cooling capacity: 170 kw 675 kw

. Ev d & AUTOMATIC WASHER

Operating Manual. Model Coolant Exchanger

Operating Instructions Indicating and adjustment module PLICSCOM

ACTIVESMART FRIDGE 900MM FRENCH DOOR SLIDE-IN WITH ICE & WATER

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

INUI-LEDSDL10 Specification

Comforting when the fuel grows

Transcription:

ASPIRATING SMOKE DETECTION SYSTEMS

Aspirating Smoke Detection FAAST TM LT FAAST LT deivers a fexibe soution for appications where standard detection methods are prone to faiure or fase aarm Designed with the instaer and end user in mind, the FAAST LT serves a wide variety of EN54-20 Cass C appications where maintenance is difficut, other smoke detection methods are inappropriate, due to harsh environments, or areas where aesthetics matters. FAAST LT devices are avaiabe as singe channe and dua channe devices, offering fexibiity for different detection strategies. A range of customisabe settings are geared towards maximising device performance and meeting different appication needs. Key Features Singe & Dua channe versions with independent channes incuding fan, sensor and fow monitoring Mutipe event ogging up to 2240 events Utrasonic airfow sensing PipeIQ LT software provides intuitive system ayout and configuration a in one package User friendy air fow penduum graph for verification of pipe network functionaity Protected eectronics from air fow and accidenta damage during instaation or maintenance Easiy repaceabe and reusabe fiter without affecting the rest of the device Designed for efficient wiring and instaation: cabe gand hoes, easy access to the wiring area and no specia toos required. Easy access to parts requiring routine maintenance: fiter(s) or sensors(s). IP65 encosure

FAAST LT TECHNICAL SPECIFICATION MECHANICAL SPECIFICATION ELECTRICAL FAAST LT FL0111E, FL0112E, FL0122E Height 403 mm (incuding inets & outets) Smoke Sensor Optica aser point type Width 356 mm Externa Suppy Votage 18.5-31.5 VDC Depth 135 mm Remote Reset Time 2 seconds Cabe Access Knock out cabe gand hoes Power Reset 0.5 seconds Maximum Singe Pipe Length 100 m Avg. Operating Current Wire Gauge 0.5 mm 2 to 2 mm 2 Maximum Tota Branched Pipe Length 160 m (per channe) (excuding sounders) 1 Channe Device Maximum Air Inet Hoes 18 hoes (per channe) 2 Channe Device Coverage Area up to 2000m 2 Outside Pipe Diameter 25 mm or 27 mm Max. Avg. Operating Current Interna Pipe Diameter 15-21 mm (excuding sounders) Sensitivity Range (obscuration) 0.07%/m 1 Channe Device 2 Channe Device Reays 3 (1 Aarm, 1 Faut, 1 Preaarm) Reay Contact Ratings 170mA @ 24 VDC 270mA @ 24 VDC 360mA @ 24 VDC 570mA @ 24 VDC 2.0 A @ 30 VDC, 0.5 A @ 30 VAC Sounder Outputs 1 per channe Communication Loop Suppy Votage Loop Standby Current @ 24V 15-29 VDC (Loop current 900mA) 900 μa max. (po once every 5s) Event Log 2244 events ENVIRONMENTAL Termina bocks: power suppy, reays, sounder Operating Temperature -10 C to 55 C Interfaces outputs, externa input; Loop Connection, USB Humidity Range 10 to 93% (non-condensing) port; Buttons (Test, Reset, Disabe) IP Rating IP65 Power suppy & reays connections 2mm 2 LISTINGS AND APPROVALS USB Shipping Weight Standard USB cabe for Type B USB Connection 6.5kg (dua channe) incudes packaging CPD LPCB Fow monitoring and reporting Fitration Fan contro High & ow according to EN54-20 Repaceabe fiter 10 programmabe speeds EN54-20 (hoes per channe) Cass A 3 hoes Cass B 6 hoes Cass C - 18 hoes Dimensions User Interface Dispay 44 mm The front pane wi be different depending on which of the modes is being instaed. The foowing dispay information is possibe: 403 mm 367 mm Aarm eve; Aarm, Pre-Aarm Particuate Leves; 1-9 Faut Status Fow Leve Test, Reset and Disabe Buttons 356 mm 56 mm 135 mm

Product Range FAAST LT Stand Aone Aspirating Systems ORDER CODES Singe channe, singe detector FAAST LT aspirating unit compete with reay outputs. Aso incudes buit in fiter. FL0111E-EB Singe channe, dua detector FAAST LT aspirating unit compete with reay outputs. Aso incudes buit in fiter. FL0112E-EB Dua channe, dua detector FAAST LT aspirating unit compete with reay outputs. Aso incudes buit in fiter. FL0122E-EB FAAST LT specific accessories Earth Bar F-LT-EB FAAST LT Repacement interna fiter (Pack of 6) FL-IF-6 For a fu range of fiters, pipework and accessories pease refer to your price ist.u Honeywe Te: +44 (0) 116 246 2000 Fax: +44 (0) 116 246 2300 Emai: hsuksaessupport@honeywe.com 140 Waterside Road Hamiton Industria Park Leicester LE5 1TN November 2014 2014 Honeywe Internationa Inc.

Aspirating Smoke Detection FAAST TM 8100E FAAST is a ground breaking aspirating soution designed to deiver highy accurate and discreet eary warning fire detection. The FAAST Aspirating smoke detector combines dua source (bue LED and infra-red aser) optica smoke detection with advanced agorithms to detect a wide range of fire types whie maintaining enhanced immunity to nuisance particuates. This enabes FAAST to accuratey detect incipient fire conditions as eary as 30 minutes before a fire actuay starts in Cass A and Cass B fire detection. Key Features Detection as precise as 0.0015%/m obscuration Integra Ethernet interface enabes remote monitoring and e-mai status updates Patented partice separator and fied-repaceabe fiter remove contaminants from the system Five aarm eves & two sensitivity modes Dua fow detection incuding both utrasonic and eectronic sensing for pipe and chamber air fow measurement Protects up to 2,000 square metres Advanced detection agorithms reject common nuisance conditions PipeIQ software provides intuitive system ayout, configuration, and monitoring a in one package Faut indictors covering a broad spectrum of events Unique air fow penduum graph verifies pipe network functionaity Particuate graph dispays subte environmenta changes for eary probem indications

FAAST 8100E TECHNICAL SPECIFICATION MECHANICAL SPECIFICATION FAAST 8110E ELECTRICAL Height 337 mm Externa Suppy Votage 18-30 VDC Width Depth 330 mm 127 mm Remote Reset Time Externa monitor must be pued ow for a minimum of 100 ms Cabe Access 2.54 cm cabe entry hoes on top and bottom of unit Power Reset 1 sec. Wire Gauge max. min. 2.0 mm 0.5 mm Avg. Operating Current 500 ma @ 24 VDC Maximum Singe Pipe Length 120m Maximum Tota Branched Pipe Length 320m Aarm 650 ma A reays active, a aarm eves dispayed. Votage @ 24 VDC Maximum Air Inet Hoes 36 hoes Network Outside Pipe Diameter 25 mm Maximum Current Draw 650 ma Votage at 18 VDC Interna Pipe Diameter 15-21 mm ENVIRONMENTAL Reays 8 changeover contacts, 3 AMP, atching or nonatching Operating Temperature 0 C to 38 C Samped Air Temperature -20 C to 60 C Event Log 18,000 events stored Humidity Range 10 to 95% (non-condensing) Sensitivity Range (obscuration) 0.0015%/m. obs - 20.5%/m obs IP Rating IP30 Communication Network Ethernet monitoring, 6 e-mai address aerts Coverage Area Up to 2000sq. m Dimensions FAAST User Interface Dispay 330 mm 127 mm The User Interface consists of 5 Aarm eves Aert, Action 1, Action 2, Fire 1, and Fire 2, 10 Particuate eves, 10 Bi-coour Fow and Faut graph 337 mm

Product Range DESCRIPTION ORDER CODES FAAST high sensitivity aser aspirating unit. Incudes buit in repaceabe fiter. 8100E FAAST specific accessories FAAST Repacement interna fiter F-A3384-000 For a fu range of fiters, pipework and accessories pease refer to your price ist.uide Honeywe Te: +44 (0) 116 246 2000 Fax: +44 (0) 116 246 2300 Emai: hsuksaessupport@honeywe.com 140 Waterside Road Hamiton Industria Park Leicester LE5 1TN November 2014 2014 Honeywe Internationa Inc.

Aspirating Smoke Detection FAAST XS (Mode 7100XE) FAAST Fire Aarm Aspiration Sensing Technoogy FAAST XS aspirating smoke detectors deiver highy accurate Very Eary Warning Fire Detection for the smaer appications and offer extensive communication capabiities. Description The FAAST XS aspirating smoke detector combines advanced partice separation with unique dua source optica smoke detection technoogy to provide highy sensitive Very Eary Warning Fire Detection whie providing enhanced immunity to fase aarms. This technoogy enabes FAAST XS to accuratey detect incipient fire conditions up to Cass A (according to EN54-20), in appications ranging from mission critica to harsh and extreme environments. An instaed FAAST XS device can administrate up to 170 m pipe ength in standard coverage type appications and can be monitored in severa different ways, incuding: Seria or TCP Modbus, Ethernet over a LAN or a direct connection, or via FAAST XS s onboard USB. When connected to a LAN, FAAST XS s emai server can provide emai event notification to appropriate personne. FAAST XS aso communicates aarm and notifications via reays. Agency Listings (pending). Pending PipeIQ is FAAST XS s intuitive design, configuration, and monitoring software. The a-in-one program can be used to create a pipe network taiored to meet site specific requirements, configure a FAAST XS device, and monitor an instaed device - incuding ive trending and reading of historic reports. A compimentary downoad of PipeIQ is avaiabe at www.faast-detection.com. F E AT U R E S Approved for use in Cass A, B and C, according to EN54-20 Provides Very Eary Warning Fire Detection, as precise as 0.00095%/m obscuration Three aarm eves and three sensitivity modes provide appication fexibiity User configurabe 3-speed fan, aowing for maximum coverage area or minimizing on current consumption Utrasonic fow sensing and chamber airfow monitoring for precise system heath information Dua source optica detection chamber with enhanced agorithms provide high sensitivity with greater immunity to nuisance conditions Patented partice separator removes arge, non-fire particuate, ensuring chamber heath and extending the ife of the fied-repaceabe fiter TCP and Seria Modbus for easy integration with buiding management systems Easy configuration via USB interface, no externa power needed Onboard Ethernet interface enabes remote monitoring, configuration, web server and e-mai notifications Mutiingua LCD user interface aows for detaied device information and interaction such as: Active fauts, precise airfow monitoring, reset of airfow baseine, test/reset/isoate and more Configurabe air fow faut threshods and verification period Convenient wiring compartment Status-at-a-gance provides immediate aarm, faut and airfow status

FAAST XS (Mode 7100XE) Product Specifications PHYSICAL SPECIFICATION HEIGHT WIDTH DEPTH WEIGHT CABLE ACCESS WIRE GAUGE TOTAL PIPE LENGTH TOTAL HOLE NUMBERS OUTSIDE PIPE DIAMETER INTERNAL PIPE DIAMETER RELAYS OPERATING SPECIFICATION 279 mm 229 mm 159 mm 4 Kg 2.54 cm cabe entry hoes on top and back of the unit Minimum 0.5 mm - 2.0 mm maximum 170 m (a designs must be verified within PipeIQ software) Cass A: 16 hoes / Cass B: 20 hoes / Cass C: 20 hoes (a designs must be verified within PipeIQ software) 25 mm 15-21 mm 5 changeover, programmabe atching or non-atching Aert, Fire (2), Faut, Isoated OPERATING TEMPERATURE 0 C to 38 C; Factory Tested to 55 C SAMPLED AIR TEMPERATURE -20 C to 60 C HUMIDITY SENSITIVITY RANGE IP RATING COVERAGE AREA 10 to 95% (non-condensing) 0.00095% Obs/m to 20.5% Obs/m IP30 AIR MOVEMENT 0-1,219m/min DIAGNOSTIC SPECIFICATION EVENT LOG TREND DATA LOG SERVICE LOG NETWORKING SPECIFICATION COMMUNICATION NETWORK NETWORK SERVICES ETHERNET MODBUS EMAIL WEBSERVER ELECTRICAL SPECIFICATION EXTERNAL SUPPLY VOLTAGE REMOTE RESET TIME POWER RESET OPERATING CURRENT ALARM CURRENT RELAY CONTACT RATINGS Up to 2,000 m2 (pease consider regiona standards and guideines) 18,000 events stored configurabe samping period 1 minute to 1 day 300 customer user entries Ethernet monitoring, 6 emai address aerts, TCP and Seria Modbus DHCP, SMTP, HTTP, MODBUS/TCP, AutoIP, NetBIOS-NS, Seria MODBUS 10/100 Mbps, MDI-X TCP or Seria RS-485 6 recipients, seectabe notifications Read Configuration, Live View, Logs 18-30 VDC Externa monitor must be pued ow for a minimum of 100 ms 1 sec. Fan High - 200mA, 4.8W; Fan Med - 151mA, 3.7W; Fan Low - 120mA, 2.1W Fan High - 230mA, 5.6W; Fan Med - 172mA, 4.2W; Fan Low - 142mA, 3.5W 3.0 A @ 30 VDC, 0.5 A @ 125 VAC INTERFACE SPECIFICATION PIPEIQ MODBUS ORDERING INFORMATION PART NO DESCRIPTION ACCESSORIES USB or Ethernet Ethernet or RS-485 7100XE FAAST XS HIGH SENSITIVITY LASER Various accessories are avaiabe upon request Additiona accessory information, incuding part numbers, can be accessed at systemsensor.com/faast 229 mm FAAST XS User Interface Dispay 159 mm 279 mm The User Interface consists of 3 Aarm eves - Aert, Fire 1, and Fire 2, 10 Particuate eves, 10 Airfow indicators, 4 Faut indicators, LCD. Honeywe 140 Waterside Road Hamiton Industria Park Leicester LE5 1TN Te: +44 (0) 116 246 2000 Fax: +44 (0) 116 246 2300 Emai: hsuksaessupport@honeywe.com A technica data is correct at the time of pubication and is subject to changes without notice. A trademarks acknowedged. Instaation information: In order to ensure fu functionaity, refer to the instaation instructions as suppied. DS9400XE-16 2 03/17 2017 Honeywe Internationa Inc.

Automatic Purging Unit: F-BO-AFE70-2 FAAST Fire Aarm Aspiration Sensing Technoogy Overview The FAAST Automatic Purging Unit provides a fuy integrated and compact soution with user-seectabe preventative or event triggered purging programs. An inteigent and instaationfriendy design ensures AFE70-2 is a cost effective and reiabe means of preventing pipe network contaminant bockages. Description ASD systems continuousy monitor the air in a protected environment, potentiay subjecting the system to contamination over time. In order to prevent the buid up of pipe or aspiration hoe contaminates, reguar ASD system purging with compressed air is essentia. In contrast to conventiona purging systems,honeywe s compact and user-friendy AFE70-2 unit features a singe buit- in Soenoid vave, which initiates the reease of air into the ASD system. This vave aso increases reiabiity by protecting the unit from any compressed air damage and can be accessed through a contro board that is integrated into the housing. Instaation time is greaty reduced, thanks to a compact and fuy integrated design, removing the need for mechanica and eectrica contro devices. Further cost savings can be everaged by a reduced need for cabing and pipe work to commission the system. With user-definabe purging processes and customisabe program features, AFE70-2 deivers continuous and uninterrupted air fow and is aso optimised to assist with benchmark preventative maintenance regimes, through automatic purging processes that can be set up at specific times. These purging processes are independent of any faut-initiated purging procedures performed by the system. Designed with the engineer in mind, the system offers exceent fexibiity; externa devices - such as a push- button or a centra timer can be connected to an input to aow initiation of additiona manua or automatic activations of the purging process. F E AT U R E S A fuy integrated and compact system, designed for arger pipe networks Designed for use in Honeywe Aspiration Smoke Detection ( ASD) systems Patented design without air resistance (as defined by EN 54-20) 6 user seectabe preventive or event-triggered purging programs - Short or ong purging cyce options Interna cock or externa cock timer can be connected Severa systems can be couped in Master-Save mode Manua contro via externa push-button Automatic initiation if a faut message is received from the ASD system (activating through FACP ony) Easy commissioning without software toos Muticoored LED indicates the system condition

F-BO-AFE70-2 Architect/Engineer Specifications PURGING UNIT HEIGHT WIDTH DEPTH 68 mm 204 mm 160 mm HOUSING COVER COLOUR Grey white, RAL 9002 WEIGHT 3.2kg (approx.) PATENT NUMBER AT 514912 COMPRESSED AIR CONNECTION MAX. PERMISSIBLE OVERPRESSURE RECOMMENDED MINIMUM PRESSURE FLOW RATE SOLENOID VALVE 0.7MPa (7.0bar) 0.2MPa (2.0bar) 0.2MPa: typ. 1,300 /min 0.4MPa: typ. 2,300 /min 0.6MPa: typ. 3,200 /min 0.7MPa: typ. 3,700 /min ENVIRONMENT OPERATING TEMPERATURE IP RATING +5 C to +50 C IP20D RELATIVE HUMIDITY Max. 95% at 40 C ORDERING INFORMATION DESCRIPTION Purging Unit / AFE70-2 Non-return vave for pipework ELECTRICAL SPECIFICATION SUPPLY VOLTAGE CURRENT CONSUMPTION @ 24V PART NUMBER F-BO-AFE70-2 RSV-R25 21.6 30 VDC 8mA (norma condition) 300mA (soenoid vave energised) System Configuration Pipe Network RSV-R25 non return vave Honeywe 140 Waterside Road Hamiton Industria Park Leicester LE5 1TN Te: +44 (0) 116 246 2000 Fax: +44 (0) 116 246 2300 Emai: hsuksaessupport@honeywe.com A technica data is correct at the time of pubication and is subject to changes without notice. A trademarks acknowedged. Instaation information: In order to ensure fu functionaity, refer to the instaation instructions as suppied. DSF-PSU-2405 07/17 2017 Honeywe Internationa Inc.

ASPIRATING SMOKE DETECTION SYSTEMS EN54-4 APPROVED POWER SUPPLY UNITS 2.5A and 5.25A versions Encosure mounted with battery space 110V or 230V input, Reguated true 24V output Inteigent battery charging and temperature compensation Houses up to 12Ah batteries Status indicators for monitored fauts Fuy encosed and robust construction Power suppy Units fuy certified to EN54-4 provide a stabe and fuy reguated, true 24V output for fire aarm system appications under a power conditions. The unique reguation techniques ensure that even when running on standby batteries, a stabe 24V suppy is avaiabe to a parts of the system ensuring that a 24V powered devices connected are suppied with optimum power. The powerfu onboard micro-controer ensures that a battery types are conditioned with optimum, temperature compensated charging agorithms to maximise battery ife and maintain batteries in top condition. The EN54-4 compiant power suppies can be fitted with an optiona dua fused output monitoring modue to ensure compiance with European standards when suppying fire contro panes with an externa power suppy. DIMENSIONS (mm) 500 ORDER CODES EN54 2.5A Power Suppy abe to charge up to 12Ah batteries (500 x 355 x 117mm) EN54 5.25 Amp Power Suppy abe to charge up to 12Ah batteries (with Dua Output Board) 4I0AC ASD-PSU25 05214-24-EN 355 117

ASPIRATING SMOKE DETECTION SYSTEMS EN54-4 APPROVED POWER SUPPLY UNITS TECHNICAL SPECIFICATION Construction Finish Coour id & box Mains input suppy votage Mains suppy fuse 1.2mm mid sheet stee Epoxy powder coated BS 00 A 05 grey fine texture 230V AC 50/60Hz or 11 0V AC 50/60Hz (ink seectabe) 250V, 3A, SB, 5mm x 20mm Load output votage 19-30V DC +/- 1% Maximum oad current 05214-24-EN modes 5.25 Amps continuous with maximum battery charge output of 1.25A Maximum oad current ASD-PSU25 2.5 Amps continuous with maximum battery charge output of 1.0A Maximum rippe 200 miiamps Load fuse 5 Amp, sef resetting Poyfuse Maximum current draw from batteries 5 Amps Battery charge output votage 27.4V DC nomina at 20ºC Battery charge current Deep discharge prevention Compatibe batteries Operating temperature Common faut output Battery disconnected output Battery ow output Charger faut output Earth faut output Mains faied output Faut output connector Mains connector Load connector Battery connector Front pane Power Front pane Faut indicator Power output 2 stage, constant votage 1.25 Amps maximum Battery disconnects at 1 9V Yuasa NP7-1 2, NP1 2-12, NP1 7-12, NP24-1 2 Powersonic PS-1270, PS-12120, PS-12170, PS12260-5ºC to +45ºC Normay energised vot free changeover reay 30V DC 1 Amp Open coector 50 miiamps Open coector 50 miiamps Open coector 50 miiamps Open coector 50 miiamps Open coector 50 miiamps 14 way DIL header 0.1" spacing 3 way termina, 7.62mm spacing, 2.5mm maximum cabe size 2 way termina, 7.62mm spacing, 2.5mm maximum cabe size 2 way termina, 7.62mm spacing, 2.5mm maximum cabe size On indicator Green LED Yeow LED Dua 24V suppy terminas with EN54-4 cause 6.4 interface (When fitted with optiona dua fused output monitoring modue)