Drying ovens, incubators, cooled incubators

Similar documents
Laboratory refrigerators

Made in Poland. Established POL-EKO-APARATURA. products. Your partner in laboratory analysis and technological processes

Table of contents. Table of contents. Development history THERMOSTATIC EQUIPMENT. Cooled incubators (ST) Laboratory refrigerators. Laboratory freezers

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

Laboratory thermostatic chambers

ZL Laboratory freezers

ICH750L. Climate Chamber. Product specification

ICP450. Compressor-cooled incubator. Product specification

Constant climate chamber with ICH-compliant illumination

Constant climate chambers

Constant climate chambers

Heated and Refrigerated Incubators

Stability Chambers & Rooms

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

laboratory & sterilization technology

ICH260C. Climate Chamber. Product specification

ICH110. Climate Chamber. Product specification

Drying and heating chambers

Constant climate chambers

FITOCLIMA 600 & 1200 STABILITY

FITOCLIMA 600 & 1200 STABILITY

FITOCLIMA 600 & 1200 PHARMA

VWR INCU-Line Peltier Cooled Incubators. Instruction Manual

Constant climate chamber with humidity

Sunrise the beginning of a brand new day

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

STABILITY ICH. ICH Stability Tests

Instruction Manual. DRY-Line DL 56 Prime: DL 112 Prime: DL 180 Prime:

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Drying and heating chambers. Series ED FD FED FP M

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Digital incubating/ refrigerating benchtop shakers

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Model KBWF 240 Growth chambers with light and humidity

Caution: Before using the device first read carefully this manual!

Refrigerated Incubators / Environmental Testing Chambers

Plant growth chambers

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

Caution: Before using the device first read carefully this manual!

laboratory & sterilization technology

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Model KBWF 720 Growth chambers with light and humidity

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Chromatographic Air circulated Refrigerator, two-door TC 603

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6

OPERATING INSTRUCTIONS. G214 Software - Version 4

AZTECA A LITRE STERILISER

Photo Stability Chamber

NC SERIES. Bench Top Steam Sterilizers

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

Constant climate chambers

Product Highlights. BINDER Scientific with New Avantgarde.Line Products

NC 100. Vertical Steam Sterilizer

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

NEW GENERATION. Efficient use of valuable space INCUBATORS

BATHS SHAKERS STIRRERS HOTPLATES INCUBATORS HEATING MANTLES INCUBATORS

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient


Constant climate chambers

Plant Growth Humidity Chamber

FITOCLIMA 600 & 1200 BIO

Walk in Freezer. Comfortable work environment

Environmental simulation chamber for complex alternating climate profiles

Stability Studies? Walk in Stability Chamber BUY RENT SERVICE. Thermolab is a one stop solution for all your stability requirements

Constant climate chambers

EC 160 CO 2. Incubator

OT SERIES. Bench Top Steam Sterilizers

TCC-34. Features: TISSUE CULTURE

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Application description

Environmental Chambers Series: reach-in & benchtop capacities

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Forced Convection. Laboratory Ovens. Isotherm Forced Convection Laboratory Ovens, 110L, 54L and 32L models.

Benchtop & Compact Test Chambers

Thermo Scientific Heraeus microbiological incubators An optimal environment for your samples

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

SPC-56 SHORT PLANT.

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

HOT AIR OVEN. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

HALT & HASS Systems.

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

Thermo Scientific Heratherm Heating and Drying Ovens. efficient

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Multi-Lab REFRIGERATORS Frigidere medicale

Laboratory Refrigerator/Deep Freezer TC 802

WR-KWAP (Platelet incubator/agitator) HPL

FUNCTION LINE HEATING AND DRYING OVENS

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

PowerWizard Range. Digital Control Systems & Remote Communication Options. PowerWizard Providing Safe Control of Your.

MS Mini Incubator MO-MINI. Incubator. Specification. Ordering Information. Accessories

Transcription:

rying ovens, incubators, cooled incubators rying ovens, incubators, cooled incubators All the units in the ST version are equipped with a PI microprocessor controller with an LC graphic display and illuminated touch buttons. Controller advantages sixsegment temperaturetime profile loop function up to 99 times or endless 3 user programs memory adjustable start delay feature (from 1 min to 99:59 h) adjustable hold at set point time for temperature and lighting (for IL/FOT) from 1 min to 100 days, or continuous operating adjustable ramps overview of set and current parameters while operating recording of min, average and max temperature value for each segment possibility of temperature calibration by the user audible and visual temperature alarm operating with temperature priority temperature sensor fail alarm power failure control system (program continued after restoring power) digital timer real time clock autodiagnostic function internal memory to store up to 2046 data records natural (SL/SR/CL) or forced (SL/SR/CL/IL) air convection with fan speed control (for CLW/SLW/SRW 15115 0..., CLW/SLW/SRW 1801000 and ILW 10... ) automatic fan shutdown after completing the program automatic airflap control (CL/SL/SR) Temp. C 0% T3 70 C TIME 3 T1 50 C T0 20 C T2 15 C TIME 0/1 TIME 1 50 C TIME 1/2 TIME 2 15 C TIME 2/3 70 C 1h 2h 5h 1,5h 3h 1,5h 3h 1,5h temperature Time [h] parameter set by the User fan speed control T1/T2/T3 segment temperature TIME 0/1... ramp time adjustable start delay air flap control (1 min 99:59 h) (CL/SL/SR only) TIME 1/2/3 segment time 39

rying ovens, incubators, cooled incubators Control panel active loop function current segment number operating status (heating/cooling) LC graphic display alarms or malfunction current temperature standby button set temperature program name current date/time ESC button ENTER button scroll down button scroll up button Standard features o o o o temperature range: SL (+5 C above ambient temp.... +300 C), SR (+5 C above ambient temp.... +250 C), o o o o o o CL (+5 C above ambient temp.... +100 C), IL (0 C up to 70 C / optionally 10 C up to 70 C) o o o quality control protocol (at +37 C for CL/IL, at +105 C for SL, at +170 C for SR) English instruction manual available menu languages: Czech, English, Estonian, French, German, Italian, Polish, Portuguese, Russian, Spanish temperature protection class 2.0 to IN 12880 open door alarm wheels in standard for models 750, 1000, ILW 400 RS232 and USB ports for data transfer access port: Ø30 mm for models 531000 or Ø9 mm for models 1532 wire stainless steel shelves solid door, internal glass door for CL and IL door lock 40

rying ovens, incubators, cooled incubators TOP+ version All the units in the TOP+ version are equipped with a PI microprocessor controller with a large (5,7'') full colour touch screen, intuitive menu and user friendly software. They can be connected to Ethernet network for remote control from any computer, being one of the greatest advantages. Controller advantages multisegment temperaturetime profile (up to 100) Administrator function to manage User accounts adjustable start delay feature (from 1 min to 99:59 h) access control via login 7 days programming loop function up to 99 times or endless adjustable hold at set point time for temperature and lighting (for IL/FIT) from 1 min to 999:59 h, or continuous operating adjustable ramps overview of set and current parameters while operating recording of min, average and max temperature value for each segment possibility of temperature calibration by the User audible and visual temperature alarm operating in temperature or time priority mode temperature sensor fail alarm power failure control system (program continued after restoring power) digital timer real time clock autodiagnostic function natural (SL/CL) or forced (SL/CL/IL) air convection with fan speed control for CLW/SLW 53/115 O...; CLW/SLW 1801000 and ILW 10... automatic fan shutdown after completing the program automatic airflap control (CL/SL) GLP supporting functions password protected settings 20 user programs memory internal memory to store up to 4100 data records for each User, possibility to overview the values on the display or a PC computer in tabular or graphic form USB port to allow direct data recording or transfer onto a flash drive events registry Temp. C 0% T3 70 C TIME 3 T1 50 C T0 20 C T2 18 C TIME 0/1 TIME 1 50 C TIME 1/2 TIME 2 18 C TIME 2/3 70 C 1h 2h 5h 1,5h 3h 1,5h 3h 1,5h temperature Time [h] parameter set by the User adjustable start delay (1 min 99:59 h) fan speed control air flap control (CL/SL/SR only) T1/T2/T3 segment temperature TIME 0/1... ramp time TIME 1/2/3 segment time 41

rying ovens, incubators, cooled incubators Control panel operating status (cooling/heating) current temperature program name current date/time/weekday alarms door open info main menu loggedin user USB flash drive pluggedin overview of program parameter internal light ON Standard features o o temperature range: SL (+5 C above ambient temp.... +300 C), o o o o o o CL (+5 C above ambient temp....+100 C), IL (0 C up to 100 C / optionally 10 C up to 100 C) Ethernet cable TOP+ Control software USB port to allow direct recording and data transfer onto a flash drive o o quality control protocol (at +37 C for CL/IL, at +105 C for SL English instruction manual available menu languages: English, Estonian, French, German, Hungarian, Italian, Latvian, Polish, Portuguese, Romanian, Russian, Spanish temperature protection class 3.3 (IL), class 3.1 (CL/SL) to IN 12880 open door alarm wheels in standard for models 750, 1000 RS232 interface Ethernet port for remote control access port: Ø30 mm wire stainless steel shelves solid door, internal glass door for CL and IL door lock 42

Cooled incubators IL Cooled incubators Application microbiological tests plant growing, microorganisms breeding at precisely controlled environment BO determination incubation of samples at specified temperature Calibration Cooled incubators are perfect for incubation of samples in a stable environment, regardless of ambient conditions, at temperatures from 10 up to +100 C. All thermostatic equipment manufactured by POLEKOAPARATURA can be provided with Calibration Certificate issued by accredited Measurement Laboratory. etailed information on accreditation of POLEKO Laboratorium Pomiarowe is available on website: www.polekolab.pl. 45

Cooled incubators IL ILW 53 ILW 115 ILW 240 ILW 400 ILW 750 Parameter air convection chamber capacity 1 [l] door type temperature range [ C] temperature resolution [ C] controller internal dims [mm] power supply* INOX/G A width B height C depth width E height F depth 56 690 960 600 400 390 360 all the above technical data refer to standard units (without optional accessories) * 230V 60Hz, 115V 60Hz also available 1 working capacity of chamber can be smaller 2 depth doesn t include 50 mm of power cable 3 reinforced shelf 4 reinforced version 5 on uniformly loaded surface 69 112 245 424 749 660 1080 710 460 540 450 90 140 185 275 2/7 820 1430 760 600 800 510 1040 1650 740 800 1040 25 25 25 25 25 50 50 100 100 100 40 60 90 120 140 80 120 300 300 300 510 1260 1820 860 1040 1200 400 400 800 1200 1800 2/5 All data on temperature stability and uniformity available on www.poleko.eu. 10 (option)/ 0...+70 (+100 for TOP+ version) microprocessor with external LC graphic display interior acidproof stainless steel to IN 1.4301 housing 2 overall dims [mm] 5 max shelf workload [kg] 3 max unit workload [kg] nominal power [W] weight [kg] over temperature protection shelves fitted warranty manufacturer PW version 4 W version forced double/door with viewing window (option) every 0,1 powder coated sheet stainless steel linen finish class 2.0 according to IN 12880 / class 3.3 (option) / 3.3 in TOP+ 230 V 50 Hz 600 3/10 3/14 5/16 24 months POLEKOAPARATURA Options and accessories (icon description see pages 8081) A C INOX IN 3.3 KG 90% 30% RS 422 B F E RS 485 RS 232 RS 422 RS 485 USBK Professional KAFKA IQ OQ PQ 46

Peltiercooled incubators ILP Innovative and ecological ILP Peltiercooled incubators Advantages over compressorcooled incubators Quiet operation The noise generated by the unit has been limited significantly to create more comfortable working conditions in the laboratory. Environmentally friendly Elimination of compressor and refrigerants ensures environmental protection. Lighter and smaller The Peltierelement system has reduced the size and weight of the unit. Vibrationfree With the introduction of the Peltierelement system, vibrations previously generated by the compressor have been eliminated. Energysaving The Peltier technology has reduced the power consumption considerably to make the ILP incubators even more energyefficient. Perfect performance The cooling system based on the Peltierelement features excellent temperature stability and uniformity. It also improves the temperature recovery time (e.g. after door opening). cooling heating Peltierelement electric power Peltier element electric power cooling heat dissipation heating ambient heat Calibration All thermostatic equipment manufactured by POLEKOAPARATURA can be provided with Calibration Certificate issued by accredited Measurement Laboratory. etailed information on accreditation of POLEKO Laboratorium Pomiarowe is available on website: www.polekolab.pl. 47

Peltiercooled incubators ILP ILP 53 ILP 115 ILP 240 ILP 400 Parameter air convection chamber capacity [l] door type temperature range [ C] temperature resolution [ C] controller interior housing overall dims[mm] internal dims [mm] max unit workload [kg] nominal power [W] weight[kg] over temperature protection power supply* shelves fitted/max warranty manufacturer INOX/G A width B height C depth width E height F depth 2 max shelf workload [kg] 1 PW version forced 56 112 245 424 double / door with viewing window (option) +15...+70 (+100 for TOP+ version) every 0,1 microprocessor with external LC graphic display stainless steel to IN 1.4301 powder coated sheet stainless steel linen finish 600 660 820 1040 710 850 1140 1380 660 770 810 840 400 460 600 800 390 540 800 1040 360 450 510 510 25 25 25 25 50 50 100 100 40 60 90 90 400 400 800 800 69 90 140 190 class 2.0 to IN 12880 / class 3.3 (option) / class 3.3 in TOP+ 230 V 50 Hz 2/5 2/7 3/10 3/14 24 months POLEKOAPARATURA all the above technical data refer to standard units (without optional accessories) * 230V 60Hz, 115V 60Hz also available 1 reinforced shelf 2 on uniformly loaded surface All data on temperature stability and uniformity available on www.poleko.eu. Options and accessories (icon description see pages 8081) INOX IN 3.3 KG KAFKA IQ OQ PQ RS 422 RS 485 RS 232 RS 422 RS 485 USBK Professional A C B F E 48

Cooled incubators Cooled incubators (IL) with photoperiodic system The photoperiodic (FOT) and phytotron (FIT) systems allow day and night simulation. While the FOT option enables to turn the light on and in a program, the FIT option can additionally control the light intensity. The photoperiodic system is designed for cooled incubators in the ST version and the phytotron system for the TOP+ version. Program possibilities with FOT option day and night simulation software to control light (on/), time and temperature separately for each segment temperature range for night : 10 C up to +60 C (with IL/T option) temperature range for day : +10 C up to + 50 C lamps installed in the door or ceiling fluorescent lamp 840 type (daylight) used as standard operating with time priority (see page 82) Temp. [ C] ON (day) OFF 0% (night) ON (day) (night) +50 C T3 23 C 70% TIME 3 maximum temperature T1 20 C T0 15 C T2 10 C TIME 0/1 TIME 1 20 C TIME 1/2 TIME 2 10 C 23 C 2h 4h 6h 3h 9h 4h 8h 3h TIME 2/3 temperature TIME [h] parameter set by User adjustable start delay (1 min...99:59 h) fan speed control day/night simulation TIME 0/1... ramp time TIME 1/2/3 segment time T1/T2/T3 segment temperature Photoperiodic system (*/FOT option) for cooled incubators (IL)** IL/FOT2S IL/FOT3S IL/FOT5 IL/FOT6 ST/FOT8 ST/FOT10 available for models ILW 53 ILW 115 ILW 53 ILW 115 ILW 240 ILW 240 ILW 400 ILW 750 ILW 750 temperature range with photoperiod [ C] number of lamps in door adjustable illumination intensity +10... +50 C 5 6 8 10 number of lamps in ceiling 2 3 ** FOT option is factory preinstalled. There is no possibility to order it separately. no no no no no no 49

Cooled incubators Cooled incubators with phytotron system The TOP+ version of cooled incubators (models ILW 115, 240, 400,750) can be equipped with the FIT system. Program possibilities with FIT option day and night simulation software to control light intensity [%], time, temperature and fan speed separately for each segment temperature range for night : 10 C up to +60 C (with IL/T option) temperature range for day : +10 C up to + 50 C lamps installed in overshelf panels fluorescent lamp 840 type (daylight) used as standard operating with temperature or time priority (see page 82) Temp. [ C] ON (day) OFF 0% (night) ON (day) 80% 70% T3 23 C TIME 3 T1 20 C T0 15 C T2 10 C TIME 0/1 TIME 1 20 C TIME 1/2 TIME 2 10 C TIME 2/3 23 C 2h 4h 6h 3h 9h 4h 8h 3h temperature Time [h] parameter set by the User adjustable start delay (1 min...99:59 h) fan speed control (10...) day/night simulation with illumination intensity control TIME 0/1... ramp time TIME 1/2/3 segment time T1/T2/T3 segment temperature Phytotron system (*/FIT option) for cooled incubators in TOP+ version. temperature range with phytotron ON [ C] IL/115/FIT P IL/240/FIT P IL/400/FIT P IL/750/FIT P +10... +50 C number of overshelf panels with illumination std/max 1/1 1/2 1/2 1/3 adjustable illumination intensity yes yes yes yes 50