FUNCTION LINE HEATING AND DRYING OVENS

Similar documents
Thermo Scientific Heraeus Heating and Drying Ovens

VACUUM HEATING AND DRYING OVENS Gentle and safe

Thermo Scientific Heraeus microbiological incubators An optimal environment for your samples

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient

HOT AIR OVEN. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

Thermo Scientific Heratherm Heating and Drying Ovens. efficient

Thermo Scientific Heratherm Heating and Drying Ovens. efficient safe easy. Part of Thermo Fisher Scientific

Drying and heating chambers

Thermo Scientific Heratherm Heating and Drying Ovens. Efficient, safe and easy

Vacuum drying oven for non-flammable solvents

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

Thermo Scientific Heratherm Heating and Drying Ovens

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

Efficient, safe and easy

Thermo Scientific Vacuum Ovens. Consistent performance, at a high degree

Thermo Scientific Heratherm Microbiological Incubators

Ovens. General Applications. Forced Convection Ovens. Natural Convection Ovens. Vacuum Ovens. Clean Ovens, Class 100

OVENS Forced Convection Ovens. Economy Forced Convection Ovens. Vacuum Ovens.

Safety vacuum drying oven for flammable solvents

VD 53 - Vacuum drying oven for non-flammable solvents

VWR symphony CO 2 INCUBATORS

Vacuum drying VD VDL series

Laboratory thermostatic chambers

Model C 170 CO 2 incubators with hot air sterilization

Internet. Climate rating definitions. Customer service.

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

VACUUM HEATING AND DRYING OVENS Gentle and safe

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6

Benchtop CO 2 Incubator. the Oasis 6400 series

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Vacuum drying chambers. VD VDL series

ULTRA.GUARD ultra low temperature freezer

Constant climate chambers

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:


Digital incubating/ refrigerating benchtop shakers

MOV Series Electric Ovens Dry Heat Sterilizers MOV-112F/212F MOV-112/212 MOV-112S/212S MOV-112F MOV-212

incubator, the best in its class

Protect your research

CO2 Incubators The Complete Line

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Methods of Desiccation

Environmental simulation chamber for complex alternating climate profiles

ВОДЯНЫЕ И МАСЛЯНЫЕ БАНИ

Forced Convection. Laboratory Ovens. Isotherm Forced Convection Laboratory Ovens, 110L, 54L and 32L models.

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

Operation Manual. (Version 1.5.1)

LABORATORY OVENS MODELS INCLUDE: TO-152G & TOH-152G TO-152F & TO-235F DEHYDRATING OVENS MODELS INCLUDE: TD-150F TD-330F TD-500F

Smart Oven (SWOF / SWON model) Oven (WOF / WON model) Precise Vacuum Oven (WOV model)

Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities.

KMF Environmental test chamber for constant climate

External and internal circulation with powerful pumping capability

Constant climate chambers

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Biological Incubators Biotech Ovens

Compact SLIM. Air cooler GASC. Air coolers in a flat design with forced draught fans Optimal for commercial cooling. HFCs, CO 2 0.

Stability & Shelf Life

Safety, Consistency And Reliability; Leading In The World And Recommended By China Marrow Donor Program

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

Thermo Scientific Precision Ovens

www

OVENS. All our ovens are tested to meet electrical safety standard IEC EN , this standard provides additional security for laboratories.

Plant Growth Chamber MPGR14

smallest detail Laboratory refrigerators with analogue controls and spark-free interior

Constant climate chamber with ICH-compliant illumination

Heating and Drying Ovens HeatEvent

FN 032/055/120 DRY HEAT STERILIZERS / OVENS FN 300/400/500 DRY HEAT STERILIZERS / OVENS KD 200/400/700 OVENS EV 018 VACUUM OVEN

MS Mini Incubator MO-MINI. Incubator. Specification. Ordering Information. Accessories

Bench-Top Vacuum Oven with 28 segments programmable controller

Ultra-Low. Temperature. Freezers. Advantage Series. Basic Series. Microprocessor Control. Solid-State Electronic Control

CO₂ incubators. C CB series

BINDER Scientific Product Catalog

Platinous. temperature. and humidity. chambers. Top Quality Design. With an Easy-to-use. Touch-Screen. Programmer

Drying and heating chambers. Series ED FD FED FP M

Bennett Scientific Limited Clifton Water baths

Lab Companion offers the following groups of instruments:

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Constant climate chambers

XRD XRD-1500 High-Temperature Oven. Innovation in Material Science...

Refrigerators and freezers Research and laboratory 2018

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage

Reproducible Climate...

Bench-Top Type Temperature (& Humidity) Chamber

NEW GENERATION. Efficient use of valuable space INCUBATORS

Model Model version Art. No. Model Model version Art. No. BD V 9010/ FD V 9010/ BD 56

NEW! Thermo Scientific Revco PLUS -86 C Freezers. Protecting Your Life s Work

LE Series. Electrode Steam Humidifiers

Environmental Chambers

Ovens. DAIHAN Scientific

WITH OMRON E5CC CONTROL

The right temperature worldwide NEW. LAUDA Integral XT. Professional thermostating for pilot plant and mini-plant purposes. Product information

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

Plant growth chambers

Accessories. Laboratory refrigerators and freezers. Accessories. Climate rating definitions. Customer service.

Transcription:

FUNCTION LINE HEATING AND DRYING OVENS Quality Products Lifetime Care

Heraeus Function Line Drying and Air Circulation Drying Ovens for temperatures up to 250 C: 3 sizes with 60, 120 and 200 litres sophisticated controller with large digital display for easy reading easy-to-clean interior saves time and ensures safety large volume despite a small footprint saves space in your laboratory The T 6, T 12, and T drying ovens with natural convection are used for thermal processes: heated storage, heat treatment, thermal testing, and for conventional drying processes with temperatures up to 250 C. The UT 6, UT 12, and UT 20 air circulation drying ovens are designed for high-performance drying and thermal processes, which require increased fresh air supply, short process times, precise heat control, and short heatingup times to 250 C. User-friendly thanks to intelligent solutions and technical refinements. Optimal results and high safety standards are guaranteed. Function Line systems are used in R&D laboratories as well as in quality assurance applications and production. Intelligent Solutions The Heraeus Function Line drying and air circulation drying ovens are available in three sizes. The working chamber volumes range from 60, 120 to 200 liters. The inner casing is made of corrosion-resistant stainless steel. Temperature is controlled by a precise microprocessor-based controller with a large display. Due to the compact design the ovens require a minimum of space. The heating and drying ovens can also be operated when stacked. State-of-the-Art Functionality Two types of user-friendly control elements with clearly arranged temperature displays complement the Function Line concept. The functions include a timer to activate/deactivate the oven, and to program heating-up/coolingdown and process times. Function Line ovens in P-version come standard with programmable controller. Easy Operation The main operating and display elements are located at eye level on the door. An interchangeable silicone door gasket and removeable shelf supports make cleaning easy and safe. Safety and Reliability The Function Line drying and air circulation drying ovens are designed for continuous unattended operation (upper temperature limit cut-out). All appliances are GS tested by the VDE (German Association of Electrical Engineers) in accordance with International Standard EN 61010 GS and interference suppressed. Documentation The Function Line drying and air circulation drying ovens feature an RS 232 interface for temperature documentation. Respective software is available as accessory. Sturdy one-point door latch provides optimal sealing.

set temperature (set timer) (set programs) temperature up (time up) temperature down (time down)

Interchangeable door gasket made of highly resistant degassed silicone rubber. Achtung: hier Seitenende!!! wegen Lochung UT interior: removeable shelf supports and rounded corners for easy cleaning. C C 250 250 200 200 150 150 100 100 40 2.0 4.0 6.0 8.0 10.0 A B C D hrs. 40 2.0 4.0 6.0 8.0 10.0 A B C D E F G hrs. Figure 1: Program profile of Standard Version Figure 2: Example of program profile P-Version STANDARD VERSION Combination of pre-programmed routines: A: Delayed start of heating and fan B: Heating-up C: Process time D: Cooling-down P-VERSION Same as standard version but user-defined programming of temperature profile. All UT-models in P-Version come standard with a fan-speed controller.

TECHNICAL Fax 03 SPECIFICATIONS 20 55 20 85 Fresh air supply control (UT) and overtemperature control (Class 2) for unattended operation. Type T 6/T 6 P T 12/T 12 P T 20/T 20 P Outer dimensions (W/H/D) 1) mm 552/700/540 696/850/540 754/910/720 Interior volume l 57 110 199 Interior dimensions (W/H/D) mm 352/424/386 496/575/386 554/637/566 Number of shelves standard 2 2 2 maximum 10 15 17 Shelf dimensions (W/D) mm 336/365 480/365 538/545 Maximal load per shelf kg 20 20 15 total kg 50 50 70 Weight (empty) kg 40 55 75 Temperature 2) from T A + 10 C to C 250 250 250 Temp. deviations at 150 C (spatial) ± C 5 5 4 (acc. to DIN 12880, Part 2) (temporal) ± C 0.3 0.5 0.5 Heating-up times to max. temp. min 63 60 55 Heat transfer to environment W 500 700 1000 No. of air changes per hr. 8 10 5 Electrical data (nominal values) Operating voltage 3) V 230, 1/PE AC 230, 1/PE AC 230,1/PEAC Frequency Hz 50 60 50 60 50 60 Power consumption kw 1.22 1.82 2.22 Achtung: hier Seitenende!!! wegen Lochung Sturdy door hinge with integrated cable ducts. Type UT 6/UT 6 P UT 12/UT 12 P UT 20/UT 20 P Outer dimensions (W/H/D) 1) mm 552/700/540 696/850/540 754/910/720 Interior volume l 64 112 210 Interior dimensions (W/H/D) mm 408/459/344 552/610/334 610/672/514 Number of shelves standard 2 2 2 maximum 9 14 16 Shelf dimensions (W/D) mm 362/333 506/323 564/503 Maximal load per shelf kg 20 20 15 total kg 50 50 70 Weight (empty) kg 40 55 75 Working temperature 2) from T A + 20 C to C 250 250 250 Temp. deviations at 150 C (spatial) ± C 3 3 4 (acc. to DIN 12880, Part 2) (temporal) ± C 0.3 0.3 0.5 Heating-up times to max. temp. min 42 30 40 Heat transfer to environment W 700 850 1100 No. of air changes per hr. 50 40 20 Electrical data (nominal values) Operating voltage 3) V 230, 1/PE AC 230, 1/PE AC 230, 1/PE AC Frequency Hz 50 60 50 60 50 60 Power consumption kw 1.27 2.32 2.32 1) 2) Depth without handle and wall distance. Dimensions: handle 70 mm, wall distance 80 mm T A = Ambient temperature 3) Other voltages on request. All specifications are typical measured values for series models.