PS914 Power Supply. 900-KL Keylock (optional) Page BB Battery Backup (optional) Page 3

Similar documents
Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

DE5300 Delayed Egress System. General Information

Remote Chexit Module (RCM) System. General Information

SP-1000X. Panic Device Power Controller Installation Guide. Rev

232xt Wiring Diagrams and Specifications SPECIFICATIONS: REV 1.01

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

INSTALLATION INSTRUCTIONS EA SERIES DOOR PROP/EXIT ALARM

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Series. Access Power Controllers. Installation Guide

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Installation Guide for models:

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

INSTALLATION AND OPERATION INSTRUCTIONS 303, 304, 305, CRH, CRQ, CFA SERIES 2250 WATT MODELS

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Rack Mount Series Installation Guide

Installation Guide for models:

RA889A Switching Relay

TotalPac 3 Deluge, Electric release Self-contained system

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

INSTALLATION/OPERATING INSTRUCTIONS SEQUENCING PANELS

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

FireShield Plus. GE Security. EST Life Safety & Communications Conventional Small Building Solutions. Conventional Fire Alarm Control Panels

READ AND SAVE THESE INSTALLATION INSTRUCTIONS

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

D A R A - 4. Data Aire Relay Auto-Changeover

I-745. Series 745 FireLock Fire-Pac for FireLock NXT Valves WARNING INSTALLATION, MAINTENANCE, TESTING, AND WIRING MANUAL WARNING

631RF Amp Power Supply

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

TotalPac 3 Single interlock Preaction, Electric release Self-contained system

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Fire Safety. Installation Instructions Model MMB-2 Main Control Board OPERATION. INSTALLATION Always remove power before installation.

TotalPac 3 Non interlock Preaction, Electric release Self-Contained system

INSTALLATION AND MAINTENANCE INSTRUCTIONS. MCE4 Series. Electric Cooling Package Unit. Save these instructions for future reference

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

MODEL B2 INSTALLATION MANUAL

Conventional Fire Alarm Systems

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

AL800ULADA. NAC Power Extender. Installation Guide

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

E-FSC. Conventional Fire Alarm Control Panels. Standard Features. Overview

NON- INSTALLATION INSTRUCTIONS Venstar Inc. 08/07. Digital Thermostat T2700. commercial. & 2-cool. up to 2-heat PROGRAMMABLE

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

TECHNICAL DATA OBSOLETE

Public Safety DAS Annunciator Panel

INSTALLATION MANUAL. Need Help? This manual covers the following models: T705. Power Type. Thermostat Applications Guide. Page.

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

Notes: Warrick Series 67 Intrinsically Safe Multi-Function Control Installation and Operation Bulletin

INSTALLATION MANUAL. Need Help? This manual covers the following models: T905. Power Type. Thermostat Applications Guide. Page.

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

Access Power Controllers with Power Supplies

Model 17A00 Expansion Enclosure

Installation Instructions

DIGITAL THERMOSTAT. I2:00 Su AUTO OPTIONAL HUMIDITY MODULE

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Remote NAC Power Supply D7038

AL600ULADA. NAC Power Extender. Installation Guide

Z24 Wireless Zone Controller Professional Installation Guide

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

AL600ULX Series. Power Supply/Charger. Installation Guide

CALL YOUR SALES CONSULTANT TODAY,

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

± 3% or better at 40%RH and 23ºC [73ºF] 0.8 mm 2 [18 AWG] minimum

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

INSTALLATION MANUAL. Need Help? This manual covers the following models: T805. Power Type. Thermostat Applications Guide. Page.

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

Esmi Sense FDP Fire detection panel with ALC2 loop controller

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

RA889A Switching Relay

Gas leak detection system. for heating rooms and similar environments. Description. Sensor for methane gas IP44. Sensor for LPG gas IP44

Installation Instructions

Operator: Save these instructions for future use!

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

Installation Instructions HEAT COOL FAN POWER

ATP21W02 CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS REMOVING OLD THERMOSTAT 2 THERMOSTAT DETAILS

GENERATOR SELF-TEST VERIFIER (GSV300) INSTALLATION INSTRUCTIONS

Planning Elevator Relay Groups Programming Millenium for Windows Software

Smart Si Thermostat. Installation Manual

Battery charger modules

Operator: Save these instructions for future use!

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

Transcription:

F1! DANGER 44487056 These instructions cover the following parts: PS914 Power Supply Installation Instructions! DANGER: To avoid risk of electric shock, turn off A power before installing or servicing PS914 power supply.! WARNING:! WARNING:! DANGER: PS914 Power Supply Specifications: Input 120/240 VA, 1.4 A, 50/60Hz, High Voltage lass 1 Wiring Required Output 4 Amp D @ 12/24 VD May be used to power Von Duprin & Falcon EL device at 24VD, 16A, 300ms Enclosure 14 H x 12 W x 4 D (8 knockouts, 1/2 or 3/4 ) Temperature Range 32-120 F (0-49 ) Fuse ompliance PS914 Power Supply Pages 1-3 F1, T6.3A 250 VA 900-KL Keylock (optional) Page 2 900-BB Battery Backup (optional) Page 3! AUTION: For protection against risk of fi re, replace fuse with same type and rating UL 294, UL-S318, RoHS, & F Part 15, lass 2 Output 900-2RS (optional) - Page 4 (2 Zone EL ontrol - Individual/Sequential) ompatible Boards (Optional, 2 boards maximum) Fire Alarm Input Board (Optional) Battery Backup Board (Optional) A Monitor Output 900-2RS Specifications: Inputs I1,I2 2010 Ingersoll-Rand ompany 1-877-671-7011 44487056 Rev. 10/10_a 900-2RS 900-2Q 900-4R 900-4RL 900-8F 900-8P 900-FA (Requires one option board above) 900-BB INST. INSTRUTIONS - 44487056 INST. INSTRUTIONS - 44487098 INST. INSTRUTIONS - 44487106 INST. INSTRUTIONS - 44487080 INST. INSTRUTIONS - 44487106 INST. INSTRUTIONS - 44487106 INST. INSTRUTIONS - 44487072 INST. INSTRUTIONS - 44487064 Form ontacts, 30 VD, 1 Amp, Resistive Load Dry contacts required (losed = Active) onnect control contacts between S (Signal ommon) and any input Outputs O1,O2 12/24VD, 3A (wet) when A powered 9.6-13.2VD or 19.2-26.4VD when battery powered May be used with PS914 to power EL device at 24VD, 16A, 300ms Maximum load cannot exceed power supply ratings or 3A for outputs combined Board Input Power Board requires 0.1A max. of power supply output current to operate Temperature Range 32-120 F (0-49 ) ompliance UL 294, UL-S318, RoHS, & F Part 15 Fire Alarm Input Accepts 900-FA Fire Alarm Board (Optional) 1 of 4

MOUNTING TES The PS914 must be installed in accordance with the article 760 of the National Electrical ode or NFPA 72, anadian Electrical ode, or any other applicable codes. Install the PS914 indoors within the protected premises. heck national and local codes for additional installation requirements. Enclosure must be firmly mounted to a solid surface using hardware suitable for the surface. 1 MOUNT POWER SUPPLY 1a Mark 2 Top Holes 1b Secure Enclosure with 4 Screws x x Board not shown for clarity 2 SEURE ELOSURE DOOR If No Keylock Enclosure will be secured with 2 screws as shown (done as last step) If Keylock Remove knockout and insert key cylinder, then slide in clip OR a b 2 of 4

3 PS914 SETUP AND TESTING 3a onnect A Wiring A (In) 120/240 VA Green (Ground) White (Neutral) Black (Hot) NEU LINE A Input! DANGER: Ensure A Breaker is Turned Off 900-BB onnector! DANGER 3b Use Jumper to Select 24 VD or 12 VD Output 24 VD Output Setting OR 12 VD Output Setting F1 High Voltage If main board must be removed, turn off A power and wait 8 minutes before removal Do not remove this cover, no serviceable parts 24 12 Note: Minimum of 1/4 separation between A and D wiring as well as power limited and non-power limited. A Monitor Active when A present and F1 fuse not open (Form dry contacts) A Input (Green LED) D Output (Red LED)! DANGER: If A LED is off, turn off A breaker prior to checking F1 fuse 12/24 VD Output Terminals 4 INSTALL 900-BB BATTERY BAKUP (IF ILUDED) 4a Place Batteries in Box with Terminals to the Left Refer to 900-BB instructions for additional info Battery Supervision Terminals (Form Dry ontacts) (Shown A Off) 4b Attach Wires from Battery Board Red wires = (+) Black wires = (-) Active A On Inactive A Off Note: Allow 24 hours for batteries to fully charge Red Wires = (+) + + Battery 1 Battery 2 Black Wires = (-) On-Solid A On Batteries harging BB LED (Amber) On-Blinking A Off Batteries Supplying Power 5 TURN ON A BREAKER TO TEST POWER SUPPLY Verify A LED is On = GREEN Verify D LED is On = RED Verify BB LED (if applicable) is On = AMBER 3 of 4

6 INSTALL 900-2RS OPTION BOARD (IF REQUIRED) 6a Use Jumper to Select Function! DANGER: Ensure A breaker is turned off when installing or wiring option boards 6b Plug 2RS able into any Available Option onnector Option 1 Option 2 6c Secure Board with Screws Sequential OR Individual Note: 24VD output setting required when EL device connected If installing board in location 2, rotate board 180 7 ONNET WIRING TO 900-2RS OPTION BOARD 2RS S I1 01 I2 02 GND 120/240 VA 50/60Hz Individual Mode - Typical Wiring Input I1 will activate output 1 Input I2 will activate output 2 A EPT-2/10 S I1 01 I2 02 GND 120/240 VA 50/60Hz 2RS Sequential Mode - Typical Wiring Input I1 will activate both outputs A B ontrol for Device 2 EL Device 2 (not polarized) A EPT-2/10 EPT-2/10 B B A EPT-2/10 ontrol for Devices 1 & 2 EL Device 1 (not polarized) EL Device 2 (not polarized) 4 of 4 Note: Fail secure output only allowed if approved by Authority Having Jurisdiction ontrol for Device 1 EL Device 1 (not polarized) 8 IF PS-914 HAS OTHER OPTION BOARDS, SEE THEIR INSTRUTIONS TE: WHEN INSTALLATION IS OMPLETE, SEURE ELOSURE DOOR WITH SREWS OR KEYLOK Wire table (suggested maximum) Wire Ga (AWG) Device urrent (Amps D) Output* (max. ft) 14 0.3 850 0.5 500 18 0.3 340 0.5 200 12 Using EL device with EPT or Door Loop 200 14 (PS914 required) 100 12 Using EL device with Electric Hinge/Pivot 150 14 (PS914 required) 75 *Wiring allows for 10% voltage drop at device current at 12 or 24VD Max. ft = one way distance between power supply and device Input (max. ft) 1200

44487080 900-4RL Specifi cations: Inputs I1-I4 900-4RL Option Board Dry contacts required (losed = Active) onnect control contacts between S (Signal ommon) and any input Installation Instructions Outputs O1-O4 Form contacts rated 30VD, 3A (Dry) 12/24VD, 3A (Wet) when A powered 9.6-13.2VD or 19.2-26.4VD when battery powered May be used with PS914 to power EL device at 24VD, 16A, 300ms Maximum load cannot exceed power supply ratings or 6A for outputs combined Board Input Power Board requires 0.18A max. of power supply output current to operate Temperature Range 32-120 F (0-49 ) ompliance UL 294, UL-S318, RoHS, & F Part 15 Fire Alarm Input Accepts 900-FA Fire Alarm Board (Optional) 1 INSTALL 4RL BOARD(S) INTO POWER SUPPLY! DANGER: To avoid risk of electric shock, turn off A power to power supply before installing or wiring option board 1a Review Available 900-4RL Mounting Locations (Gray) Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. PS902 1 1b Plug 4RL able into any Available Option onnector Option 1 PS902 1 Option 1 Option 2 PS904, 914 PS904 PS914 Option 1 Option 2 Option 3 PS906 1c Secure Board(s) with Screws PS906 1 2 Note: For UL listed installations, use only UL listed locks and strikes 3 2010 Ingersoll-Rand ompany 1-877-671-7011 44487080 Rev. 10/10_a

2 HOOSE FUTION OF 900-4RL BOARD BY SETTING SW2 DIP SWITHES ON OFF 4TD Four Zone ontroller Function (4TD): ontrols up to four inputs and four outputs with time delay. This is the default setting. Function LED will blink one time every 5 seconds ON OFF AO Auto Operator Function (AO): oordinates the unlocking of one or two zones with the signaling of an auto operator. Function LED will blink two times every 5 seconds SW1 OFF ON Function LED (D17) SW2 ON OFF SI Security Interlock Function (SI): ontrols multi-door interlocks. Two through six door systems are possible (additional boards required for three to six doors). Function LED will blink three times every 5 seconds 3 TO OMPLETE ONFIGURATION AND WIRING, GO TO APPROPRIATE SETION For 4TD: Go to pages 3-4 For AO: Go to pages 5-6 For SI: Go to pages 7-8 Basic Troubleshooting: Go to page 8 (OPTIONAL) DRY ONTAT ONFIGURATION Powered Outputs (Default) By default, all outputs provide12/24vd Jumpers factory installed Dry ontact Outputs (Optional) For dry contact outputs, remove appropriate jumpers and rotate 90, then reinstall (Zone 1 - Zone 4) Jumper rotated 90 Zone 2 Output 2 Zone 2 Output 2 Zone 4 Zone 3 Output 4 Output 3 Zone 4 Zone 3 Output 4 Output 3 Zone 1 Output 1 Zone 1 Output 1 2

4TD - SET TIME DELAY USING SW1 DIP SWITHES Summary of Operation Output turns ON when input is activated (closed). Time delay begins when input is released (opened). Locking Device output will remain ON during time delay. If I1-I4 inputs are wired together, outputs will sequence. DIP switches on SW1 can be turned ON by moving them in the direction that the arrow is pointing. Switches below shown in OFF position ON SW1 OFF 3 4 5 6 7 8 SW1 SW2 12345678 12 Enable Time Delay Allows you to choose which outputs will have the below time delay. Set Time Delay (0-75 seconds, 5 second increments) 0 Sec: Switches 5-8 OFF 75 Sec: Switches 5-8 ON SWITH NUMBER 4TD DIP SWITH DEFINITIONS All switches shown in OFF position in wiring diagram 1 Turn ON to enable time delay for Locking Device 1 2 Turn ON to enable time delay for Locking Device 2 3 Turn ON to enable time delay for Locking Device 3 4 Turn ON to enable time delay for Locking Device 4 5 Adds 5 seconds to the time delay when ON 6 Adds 10 seconds to the time delay when ON 7 Adds 20 seconds to the time delay when ON 8 Adds 40 seconds to the time delay when ON 4TD INPUT / OUTPUT TERMINAL BLOK DEFINITIONS Input 1 ontrol 1 Input 2 ontrol 2 Input 3 ontrol 3 Input 4 ontrol 4 Output 1* Lock 1 Output 2* Lock 2 Output 3* Lock 3 Output 4* Lock 4 *See page 2 for dry contacts 3

4TD - WIRING EXAMPLE - FAIL SEURE EPT 2 or 10 EL Device 2 (not polarized) EPT 2 or 10 ontrol 2 PS914 x 4RL GND 2 2 2 I2 1 1 1 I1 S 4RL 120/240 VA 50/60Hz GND 4 4 4 I4 3 3 3 I3 S ontrol 4 EPT 2 or 10 EL Device 4 (not polarized) EPT 2 or 10 EL Device 1 (not polarized) ontrol 1 0-100 ft, use 14 gauge stranded wire 0-200 ft, use 12 gauge stranded wire ontrol 3 Note: To control EL1 & EL2 with ontrol 1, jumper I1-I2 To control EL1 - EL4 with ontrol 1, jumper I1-I2-I3-I4 EL Device 3 (not polarized) Note: Fail secure output only allowed if approved by Authority Having Jurisdiction 4TD - WIRING EXAMPLE - FAIL SAFE Mag Lock 2 Mag Lock 1 ontrol 2 PS902 or PS904 or PS906 GND 2 2 2 I2 1 1 1 I1 S 4RL 120/240 VA 50/60Hz GND 4 4 4 I4 3 3 3 I3 S ontrol 4 Mag Lock 4 Mag Lock 3 ontrol 1 ontrol 3 Note: To control Mag Locks 1 & 2 with ontrol 1, jumper I1-I2 To control Mag Locks 1-4 with ontrol 1, jumper I1-I2-I3-I4 4 Refer to Wire Table (page 7)

AO - SET ONFIGURATION USING SW1 SWITHES DIP switches on SW1 can be turned ON by moving them in the direction that the arrow is pointing. Switches below shown in OFF position ON SW1 OFF 3 4 5 6 7 8 SW1 SW2 12345678 12 Set Auto Operator Signaling Option Determines when the auto operator signal will be active SW1 SWITH NUMBER 1 Off 2 Off 1 On 2 Off 1 Off 2 On 1 On 2 On Not Used 3 Not used Set Individual Mode or Sequential Mode Individual Mode - One input will trigger one locking device. Sequential Mode - One input will trigger two locking devices. Set Time Delay* (0-30 seconds, 2 second increments) 0 Sec: Switches 5-8 OFF 30 Sec: Switches 5-8 ON * Time Delay begins when an input is released. AO DIP SWITH DEFINITIONS All switches shown in OFF position in wiring diagram Operator is signaled when latch monitor switch becomes active. Monitor switch required Operator is signaled 0.5 seconds after control switch becomes active. No monitor switch used. Operator is signaled 1.0 seconds after control switch becomes active. No monitor switch used. Operator is signaled 1.5 seconds after control switch becomes active. No monitor switch used. 4 Turn OFF (default) to enable Individual Mode (single doors). Turn ON to enable Sequential Mode (double doors). 5 Adds 2 seconds to the time delay when ON 6 Adds 4 seconds to the time delay when ON 7 Adds 8 seconds to the time delay when ON 8 Adds 16 seconds to the time delay when ON AO INPUT / OUTPUT TERMINAL BLOK DEFINITIONS Input 1 ontrol 1 Input 2 Lock Monitor 1 Input 3 ontrol 2 Input 4 Lock Monitor 2 Output 1* Lock 1 Output 2* AO Signal 1 Output 3* Lock 2 Output 4* AO Signal 2 *See page 2 for dry contacts 5

AO - WIRING EXAMPLE - TWO SINGLE DOORS Summary of Operation For each door, access control input unlocks door. Latch monitor (LX) triggers auto operator. Single Door Board onfiguration 1. Position jumpers for dry contact for outputs 2 and 4 (see page 2). 2. Turn on switches 5 and 6 on SW1 (6 second time delay). 3. If LX is not used, turn on switch 1 on SW1. Auto Operator 1 Gray White LX (Optional) EL EL-LX Device 1 EPT 10 ontrol for Device 1 PS914 x 4RL GND 2 2 2 I2 1 1 1 I1 S 4RL 120/240 VA 50/60Hz GND 4 4 4 I4 3 3 3 I3 S 0-100 ft, use 14 gauge stranded wire 0-200 ft, use 12 gauge stranded wire ON OFF SW1 3 4 5 6 7 8 EPT 10 ontrol for Device 2 Auto Operator 2 EL Gray White SW2 LX (Optional) EL-LX Device 2 AO - WIRING EXAMPLE - DOUBLE DOORS Summary of Operation control input unlocks both doors. Both latch monitors (LX) trigger auto operators. Double Door Board onfiguration 1. Position jumpers for dry contact for outputs 2 and 4 (see page 2). 2. Turn on switches 4, 5, and 6 on SW1 (6 second time delay). 3. If LX is not used, turn on switch 1 on SW1. Note: Fail secure output only allowed if approved by Authority Having Jurisdiction Refer to Wire Table (page 7) PS914 x 4RL GND 2 2 2 I2 1 1 1 I1 S 4RL 120/240 VA 50/60Hz GND 4 4 4 I4 3 3 3 I3 S EPT 10 ON OFF SW1 3 4 5 6 7 8 0-100 ft, use 14 gauge stranded wire 0-200 ft, use 12 gauge stranded wire Auto Operator Gray White Auto Operator White Gray SW2 Second auto operator, if needed EPT 10 EL LX (Optional) LX (Optional) EL ontrol for Devices 1 & 2 EL-LX Device 1 EL-LX Device 2 6

SI - ONFIGURE SW1 DIP SWITHES DIP switches on SW1 can be turned ON by moving them in the direction that the arrow is pointing. Switches below shown in OFF position ON SW1 OFF 3 4 5 6 7 8 SW1 SW2 12345678 12 Enable Time Delay Allows you to choose which outputs will have the below time delay. Enable Interlock Set Time Delay (Output Active)* (0-30 seconds, 2 second increments) 0 Sec: Switches 5-8 OFF 30 Sec: Switches 5-8 ON SI INPUT / OUTPUT TERMINAL BLOK DEFINITIONS Input 1 ontrol 1 Input 2 ontrol 2 Input 3 Lock Monitor 1 Input 4 Lock Monitor 2 Output 1* Lock 1 Output 2* Lock 2 Output 3* Follows Output 1 by.5 Sec Output 4* Follows Output 2 by.5 Sec *See page 2 for dry contacts SWITH NUMBER SI DIP SWITH DEFINITIONS All switches shown in OFF position in wiring diagram 1 Turn ON to enable time delay for Locking Device 1 2 Turn ON to enable time delay for Locking Device 2 3 Turn ON to remove O2 from interlock (Allows a single independent door) 4 Turn ON for global interlock (interlocks with other SI boards that have this switch ON ) 5 Adds 2 seconds to the time delay when ON 6 Adds 4 seconds to the time delay when ON 7 Adds 8 seconds to the time delay when ON 8 Adds 16 seconds to the time delay when ON SI Board #1 GLOBAL INTERLOK SWITH SETTING EXAMPLES SI Board #2 SI Board #3 Application SW1-3 SW1-4 SW1-3 SW1-4 SW1-3 SW1-4 Off Off Off Off Off Off Each SI board is a standalone, 2-door interlock. Off On Off On Off On 6-door interlock by setting all boards global. Off On On On A three-door interlock, plus an additional independent door on output 2 of SI Board #2. Off On Off On Off Off 4-Door interlock (SI Board #1,2) and a standalone 2-door interlock (SI Board #3). Wire table (suggested maximum) Wire Ga (AWG) Device urrent (Amps D) Output* (max. ft) Input (max. ft) *Wiring allows for 10% voltage drop at device current at 12 or 24VD 14 0.3 850 0.5 500 Max. ft = one way distance between power supply and device 18 0.3 340 0.5 200 1200 12 Using EL device with EPT or Door Loop 200 14 (PS914 required) 100 12 Using EL device with Electric Hinge/Pivot 150 14 (PS914 required) 75 7

SI - WIRING EXAMPLE - 2 TO 6 DOOR INTERLOK, RMALLY LOKED SI onfiguration 1.Turn on switches 1, 2, 4, 5, and 6 on SW1. 2. Install 2 doors per SI board. 3. Add up to 2 additional SI boards for a total of 6 door interlock per power supply: PS902 (2 doors maximum) PS904 (4 doors maximum) PS906 (6 doors maximum) Mag Lock 2 DPS 2 (contact shown with door closed) ontrol 2 PS904 x 4RL GND 2 2 2 I2 1 1 1 I1 S 4RL 120/240 VA 50/60Hz GND 4 4 4 I4 3 3 3 I3 S ON OFF SW1 3 4 5 6 7 8 DPS 1 (contact shown with door closed) ontrol 1 Mag Lock 1 SW2 Note: Fail secure output only allowed if approved by Authority Having Jurisdiction Refer to Wire Table (page 7) BASI TROUBLESHOOTING FOR ALL FUTIONS Symptom 900-4RL Function LED (yellow) is not blinking, and inputs and outputs are inactive 900-4RL Function LED (yellow) is blinking, but inputs and outputs are inactive Inputs and outputs behaving incorrectly. heck Verify 900-4RL cable is plugged into an option connector on the main board. heck A wiring and A breaker. heck PS-900 main board F1 fuse. Use voltmeter to verify 12 VD or 24 VD output on PS-900 main board. If 900-FA option is installed onto 900-4RL, verify fi re alarm contacts are closed across and. If 900-FA option is not installed, then verify jumper wire is installed into FA-JMPR connector on the 4RL board. Verify 2-position DIP switch is set for proper function. Watch yellow LED to confi rm 4RL function setting. See page 2. (Verify each DIP switch is pushed into its fully-on or fully-off position.) Verify 8-position DIP switch is set properly for your application. If you are unsure of proper settings, contact Technical Services for assistance. (Verify each DIP switch is pushed into its fully-on or fully-off position.) Verify wiring for all input and output hardware is connected to proper terminals. (Reminder: If 900-4RL is mounted in location 1, top terminals will be GND. If 900-4RL mounted in location 2 or 3, top terminals will be S.) TE: WHEN INSTALLATION IS OMPLETE, SEURE ELOSURE DOOR WITH SREWS OR KEYLOK 8

! WARNING: F1 DANGER! DANGER:!! WARNING: 44487072 The 900-FA Fire Alarm board can be installed on any one of the following power supply or option boards (refer to installation instructions): 900-FA Fire Alarm Input Installation Instructions Input (Fire Alarm) Dry contacts required (losed = no fi re alarm) onnect control contacts between and Output (Supervision) 30VD, 1A resistive dry contact Board Input Power Board requires 0.05A max. of power supply output current to operate Temperature Range 32-120 F (0-49 ) ompliance UL 294, UL-S318, RoHS, & F Part 15! DANGER: To avoid risk of electric shock, turn off A power to power supply before installing or wiring 900-FA board. In the event a fi re alarm is active, this board will remove power from the PS902 D output and any 900-series option board output. PS902 Power Supply 900-2RS (2 Relay) 900-2Q (2 Relay w/com) If 900-FA was factory installed, go to step 2 If installing to option board, go to 1a If installing to PS902 main board, go to 1b 900-4R (4 Relay) 900-4RL (4 Relay w/logic) 900-8F (8 Zone Distribution-fuse) 900-8P (8 Zone Distribution-PT) 1a IF INSTALLING TO OPTION BOARD hoose Option Board where 900-FA is to be Installed Remove Jumper from Option Board (900-2RS option board shown) 3 Note: If using battery backup, location 3 is not available. Install 900-FA to Option Board Option board may be in any of these three locations. 2010 Ingersoll-Rand ompany 1-877-671-7011 44487072 Rev. 10/10_a

1b IF INSTALLING TO PS902 MAIN BOARD Remove Jumper Install 900-FA Here Note: omplete power failure shall result in a fail safe operation. When connected to a fire alarm releasing control unit, total loss of power for the locking mechanisms shall be configured for a fail safe operation. 2 900-FA WIRING Terminal Definitions Note: Use 18 gauge wire for all wiring. Wire length dependent on physical layout. Supervision Output ontacts Shown FA Active (open) Fire Alarm Input One 900-FA Board - Automatic Reset One 900-FA Board - Manual Reset Fire Alarm ontact losed = no fire Open = fire Two 900-FA Boards on one power supply Automatic Reset Manual Reset (Temporarily close to reset) Fire Alarm ontact losed = no fire Open = fire Two 900-FA Boards on two power supplies Automatic Reset Fire Alarm ontact losed = no fire Open = fire Fire Alarm ontact losed = no fire Open = fire TE: WHEN INSTALLATION IS OMPLETE, SEURE ELOSURE DOOR WITH SREWS OR KEYLOK

44487064 900-BB Battery Backup Installation Instructions! DANGER: To avoid risk of electric shock, turn off A power to power supply before installing or wiring 900-BB board BATTERY SPEIFIATIONS Battery Life Model PS906 = 6A @ 24V } Model PS904 = 4A @ 24V Suitable for anadian lass IV standby power for access control Model PS902 = 2A @ 24V Model PS914 = 4A @ 24V Battery Type 12VD, 7Ah Gel Sealed Rechargeable Battery (2 included) 5 Year Service Life Replacement Part Number Schlage 991280! AUTION: harge only Schlage 991280 batteries. Other types may burst, causing personal injury and damage. Observe the proper polarity when connecting the batteries. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. 1 INSTALL 900-BB ONTO MAIN IRUIT BOARD AND SEURE WITH SREW Plug onnector Here (PS914 main board shown) Secure with Screw Here 2010 Ingersoll-Rand ompany 1-877-671-7011 44487064 Rev. 10/10_a

2 INSTALL AND ONNET BATTERIES 2a Turn On A Breaker to Energize Power Supply 2b Place Batteries in Box with Terminals to the Left Battery Supervision Terminals (Form Dry ontacts) Active Inactive (Shown A Off) A On A Off 2c Attach Wires from Battery Board Red wires = (+) Black wires = (-) 2d Verify That Battery LED is On If LED is not on, cycle A power off and then back on. Note: Allow 24 hours for batteries to fully charge Red Wires = (+) + + Battery 1 Battery 2 Black Wires = (-) On-Solid A On Batteries harging BB LED (Amber) On-Blinking A Off Batteries Supplying Power! WARNING: Incorrect connection may cause damage to the batteries TE: WHEN INSTALLATION IS OMPLETE, SEURE ELOSURE DOOR WITH SREWS OR KEYLOK

! WARNING: F1 DANGER! DANGER:!! WARNING: 44487072 The 900-FA Fire Alarm board can be installed on any one of the following power supply or option boards (refer to installation instructions): 900-FA Fire Alarm Input Installation Instructions Input (Fire Alarm) Dry contacts required (losed = no fi re alarm) onnect control contacts between and Output (Supervision) 30VD, 1A resistive dry contact Board Input Power Board requires 0.05A max. of power supply output current to operate Temperature Range 32-120 F (0-49 ) ompliance UL 294, UL-S318, RoHS, & F Part 15! DANGER: To avoid risk of electric shock, turn off A power to power supply before installing or wiring 900-FA board. In the event a fi re alarm is active, this board will remove power from the PS902 D output and any 900-series option board output. PS902 Power Supply 900-2RS (2 Relay) 900-2Q (2 Relay w/com) If 900-FA was factory installed, go to step 2 If installing to option board, go to 1a If installing to PS902 main board, go to 1b 900-4R (4 Relay) 900-4RL (4 Relay w/logic) 900-8F (8 Zone Distribution-fuse) 900-8P (8 Zone Distribution-PT) 1a IF INSTALLING TO OPTION BOARD hoose Option Board where 900-FA is to be Installed Remove Jumper from Option Board (900-2RS option board shown) 3 Note: If using battery backup, location 3 is not available. Install 900-FA to Option Board Option board may be in any of these three locations. 2010 Ingersoll-Rand ompany 1-877-671-7011 44487072 Rev. 10/10_a

1b IF INSTALLING TO PS902 MAIN BOARD Remove Jumper Install 900-FA Here Note: omplete power failure shall result in a fail safe operation. When connected to a fire alarm releasing control unit, total loss of power for the locking mechanisms shall be configured for a fail safe operation. 2 900-FA WIRING Terminal Definitions Note: Use 18 gauge wire for all wiring. Wire length dependent on physical layout. Supervision Output ontacts Shown FA Active (open) Fire Alarm Input One 900-FA Board - Automatic Reset One 900-FA Board - Manual Reset Fire Alarm ontact losed = no fire Open = fire Two 900-FA Boards on one power supply Automatic Reset Manual Reset (Temporarily close to reset) Fire Alarm ontact losed = no fire Open = fire Two 900-FA Boards on two power supplies Automatic Reset Fire Alarm ontact losed = no fire Open = fire Fire Alarm ontact losed = no fire Open = fire TE: WHEN INSTALLATION IS OMPLETE, SEURE ELOSURE DOOR WITH SREWS OR KEYLOK

44487064 900-BB Battery Backup Installation Instructions! DANGER: To avoid risk of electric shock, turn off A power to power supply before installing or wiring 900-BB board BATTERY SPEIFIATIONS Battery Life Model PS906 = 6A @ 24V } Model PS904 = 4A @ 24V Suitable for anadian lass IV standby power for access control Model PS902 = 2A @ 24V Model PS914 = 4A @ 24V Battery Type 12VD, 7Ah Gel Sealed Rechargeable Battery (2 included) 5 Year Service Life Replacement Part Number Schlage 991280! AUTION: harge only Schlage 991280 batteries. Other types may burst, causing personal injury and damage. Observe the proper polarity when connecting the batteries. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. 1 INSTALL 900-BB ONTO MAIN IRUIT BOARD AND SEURE WITH SREW Plug onnector Here (PS914 main board shown) Secure with Screw Here 2010 Ingersoll-Rand ompany 1-877-671-7011 44487064 Rev. 10/10_a

2 INSTALL AND ONNET BATTERIES 2a Turn On A Breaker to Energize Power Supply 2b Place Batteries in Box with Terminals to the Left Battery Supervision Terminals (Form Dry ontacts) Active Inactive (Shown A Off) A On A Off 2c Attach Wires from Battery Board Red wires = (+) Black wires = (-) 2d Verify That Battery LED is On If LED is not on, cycle A power off and then back on. Note: Allow 24 hours for batteries to fully charge Red Wires = (+) + + Battery 1 Battery 2 Black Wires = (-) On-Solid A On Batteries harging BB LED (Amber) On-Blinking A Off Batteries Supplying Power! WARNING: Incorrect connection may cause damage to the batteries TE: WHEN INSTALLATION IS OMPLETE, SEURE ELOSURE DOOR WITH SREWS OR KEYLOK