Aerial Urban Fire Suppression. Information proprietary to Simplex Aerospace and shall not be copied without express permission from Simplex

Similar documents
Essentials of Fire Fighting, Fourth Edition Transition Guide. Chapter 1: The History of the Fire Service (Essentials, Chapter 1)

Based on NFPA 1003: Standard for Airport Fire Fighter Professional Qualifications 2015 Edition

FIRE PROTECTION BUREAU ACCREDITATION AND CERTIFICATION PO Box Olympia WA (360) FAX: (360) AIRPORT FIREFIGHTER

Cumru Township Fire Department 4/27/10 Standard Operating Guidelines Page: 1 of 6 Section 15.07

I. It shall be the responsibility of the department officers to implement this operating guideline.

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

EASTERN ARIZONA COLLEGE Fire Department Operations II

SUBJECT FIRE OPERATIONS GUIDELINE (F.O.G.) #F510 Issued: 1/2014 Last Revision: 1/2014 Pages: 9 By Order Of: J.S. Thompson, Fire Chief

Based on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition.

SPEARFISH FIRE DEPARTMENT POLICIES AND PROCEDURES

Centers for Regional Excellence. Downriver Fire Authority. Organization Committee Objective. Operations Committee Report 2007

NFPA Who we are and how we can help you

Lassen Community College Course Outline

Rapid Intervention Team

Enactment Date: Rapid Intervention Team and RIT Officer

MASTER COURSE OUTLINE

Technician I Kyle Wilson Line of Duty Death April 16, Marsh Overlook Structure Fire Investigative Report

SPECIALISTS IN INDUSTRIAL PROTECTION

Truckee Meadows Fire Protection District Guide to Wildfire Terminology

DFPC s Toolbox. Colorado Fire Prediction System (CO-FPS)

Structural Firefighting Policy

Mission. Vision. To set the standard for excellence and innovation in public safety. Department Description

SOUTHERN AFRICAN EMERGENCY SERVICES INSTITUTE NPC Registration No. 2014/162285/08. Interior Industrial Fire Brigade Member- NFPA 1081, 2007

Assignment Sheet Apply the NIMS-ICS Model to an Emergency Scene

Some Important Aspects of Fire Safety Regulations about High Rise Buildings

Chapter 1 Test. Directions: Write the correct letter on the blank before each question.

FIRES IN BUILDING & CONSTRUCTIONS

Talking about NFPA History of NFPA NFPA Standard 1710: Organization and Deployment of Fire Suppression Operations, EMS

SAFETY INFORMATION NOTICE

BROWNSVILLE VOLUNTEER FIRE DEPARTMENT

Guidelines for Media at Emergency Incidents

Truro Police Department. Fire Emergencies. Policy Number: OPS-9.02 Effective Date: June 1, 2000 REFERENCE:

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

Fire Service Considerations A Primer for Building and System Designers. Society of Fire Protection Engineers Fire Service Committee

Phumza Matitiba Assistant General Manager Eastern Cape

AIRPORT FIRE FIGHTER ID#: STANDARD:

As agreed to by the members of the Routt County Multi-Agency Coordinating (MAC) Advisory and Policy Groups on March 15, 2018.

Emergency Evacuations What you need to know

When it Really Matters

REPORT DOCUMENTATION PAGE

INSTRUCTOR GUIDE COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 1 TOPIC: ORIENTATION AND FIRE BEHAVIOR LEVEL OF INSTRUCTION:

CITY OF OWENSBORO OWENSBORO FIRE DEPARTMENT DEPLOYMENT ANALYSIS

ADVANCED EXTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

RE: BASIC FIRE SAFETY PROCEDURES AND OPERATION OF FIRE EQUIPMENT

FIRE DEPARTMENT - RULES FOR FIRE PROTECTION IN AUSTRIA

ATTIC FIRES. Part 2 LIGHT SMOKE SHOWING

Township Of Jackson, Fire District 3, Station 55 Standard Operating Guidelines FIRE GROUND STRATEGY

Firefighters Support Foundation. v1 1

Firefighting Robotic System. Reggie Grant Director, Advanced Programs - Dallas

MATRIX TO DETERMINE YOUR PRESENT POSITION IN MEETING N.F.P.A. 1720

ATTIC FIRES. Part 3 HEAVY SMOKE SHOWING

INTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

Fire Department Anchorage: Performance. Value. Results.

GREEN SHEET. California Department of Forestry and Fire Protection

STANDARD: 5.2.1(B) TASK:

ONYX EXITPOINT TM THE SOUND OF SAFETY

Travis County Emergency Services District #1 Standard Operating Guidelines

CAMDEN COUNTY FIRE COORDINATOR

FIREFIGHTER II MANIPULATIVE SKILL OBJECTIVES

Contra Costa County Fire District Station # 69. Battalion 7. November Your station responded to 129 Emergency Calls. Response breakdown

NETWORKING AND INTEGRATION

WELCOME TO ROSEVILLE UNIVERSITY

DISTRICT OF PORT HARDY BYLAW A BYLAW TO ESTABLISH AND REGULATE THE DISTRICT OF PORT HARDY FIRE DEPARTMENT

Commercial use of small UAVs in transportation and infrastructure

Training Toolbox Series. ICA11v1.0 Information, Digital Media & Technology

Chapter 3 FF II Fire Department Communications

NFPA Self Assessment Manual

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

The 2012 Fire Suppression Rating Schedule (FSRS)

TITLE: Offensive and Defensive Operations

SAGINAW FIRE DEPARTMENT SAFER

BCGEU JOB DESCRIPTION MINISTRY OF FORESTS

OVERVIEW. Increasing Awareness of Occupant Evacuation in Tall Buildings. Traditional Focus has been on Evacuation From Fire

I. INTRODUCTION. A. Purpose: To provide procedures and guidelines for personnel responding to and operating at working structure fire incidents.

Pro Board Assessment Methodology Matrices for NFPA 1001

SEE THROUGH SMOKE FROM EVERY ANGLE. FLIR Handheld, Mounted, and Aerial Thermal Imaging Cameras for Firefighting

San Joaquin County Office of Education Career & Technical Education Fire Fighter Technology CBEDS#: 5833

VOLUSIA COUNTY FIRE CHIEFS ASSOCIATION MODEL OPERATING GUIDELINE

RAMBLER PARK FIRE SAFETY INFORMATION

3330 N Clayton. C - Side Date: 11/18/2017 Time: 21:48 Incident Number: Address: 3330 N Clayton

Summary. Introduction

STANDARD OPERATING GUIDELINE Standard Response

Fire Department Orientation / Organization

FIREFIGHTER II: FIRE DEPARTMENT COMMUNICATIONS COMMUNICATIONS: SKILL SHEET #2 Define and Demonstrate Fire Department Radio Procedure

FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures

The National Fire Chiefs Council. Roy Wilsher Chair National Fire Chiefs Council

EASTERN ARIZONA COLLEGE Fire Department Operations I

FIRE FIGHTER I APPLICATION PENNSYLVANIA VOLUNTARY FIRE SERVICE CERTIFICATION PROGRAM NFPA Edition

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

D Safe, realistic, reliable DRÄGER FIRE TRAINING SYSTEMS

Emergency Preparedness Guide

FIRE RANGER PREAMBLE. Crews specifically trained to attack and extinguish forest fires. Crew and necessary equipment normally transported by truck.

Two International Finance Centre 416m. Bank of China Tower 367m. The Center 346m. Central Plaza 374m

HOTWC Aerosol Fire Suppression for High Rise Structural Applications. Aircraft Distribution using MetalStorm Technologies

Standardized Curriculum Form Ontario, Canada

AMADOR FIRE PROTECTION DISTRICT

Required Materials For complete material(s) information, refer to

Career Fire Fighter Dies While Exiting Residential Basement Fire - New York

South Lyon Fire Department 2012 Annual Report

in Major Countries (Table 1-1) The Official Name of the Country England Germany France America Korea China United Kingdom of Great Britain and Norther

Transcription:

Aerial Urban Fire Suppression

Aerial Urban Fire Surpression 7 Most city ladders can only reach 30m (7 floors) November 2013, firefighters in Sharjah, north of Dubai, struggled to battle a blaze in a 25-storey tower without equipment to reach the flames. (from a BBC newscast). The fire chief told the reporter, I wish I had equipment to fight this fire

Simplex Water Cannon STC for H225 Height is Not Problem!

Aerial Firefighting Equipment for Airbus Helicopters AS 350 & 355 Belly tank 1,200l EC225 & AS332 Belly tank 2,270l EC225 Water cannon 2,270l AS 365 Belly tank 900l Simplex

The H225 in a nutshell ALL WEATHER ALL CONDITIONS EXTRA LONG RANGE 650 NM (no IAFT) INTERNAL PAYLOAD 4t 2,8t to 200 NM (RoA) EXTERNAL LOAD Up to 4,7t UNMATCHED AVAILABILITY HIGH SAFETY STANDARDS (IOGP)

SIMPLEX SkyCannon AERIAL FIRE TRUCK For High Rise Building Firefighting

Company Overview Founded in 1946 to Develop Certified Aviation Mission Equipment 4,000+ Certified Systems Operating Worldwide Wildland Fire Fighting Systems High Rise Building Fire Fighting Systems Fire Ignition Devices Agricultural Spray Systems Oil Spill Response Slung Load Systems Powerline & Windmill Washing and Deicing Systems www.simplex.aero

Population Growth is Driving Increased City Density Fueling Growth in Number and Height of Skyscrapers Resulting in an Increase in the in Number and Severity of High Rise Building Fires (http://www.telegraph.co.uk/news/worldnews/middleeast/dubai/12076792/dubai-skyscraper-fire-new-years-eve-2015-live.html)

Number of Skyscrapers Increasing China Skyscraper Growth (Super Cities) Skyscraper is defined as building over 152 meters or 500 feet or approx. 40 stories Ranking City Completed Under Construction Planned 1 Shanghai 102 23 19 2 Hong Kong 68 2 0 3 Guangzhou 63 27 33 4 Shenzhen 58 13 59 5 Nanjing 25 7 27 6 Beijing 22 6 11 7 Chongqing 21 14 14 8 Tianjin 17 35 25 9 Wuhan 13 4 34 10 Chengdu 9 17 21 2012 Top 10 Cities 398 148 243 2017 China Forecast 802 511 2023 China Forecast 1313 9

Dubai No City Is Exempt Moscow Busan New York Venezuela

Critical Issues Facing Municipal Fire Depts Dubai Response Time Reach Utilization of Aerial Assets November 2013, firefighters in Sharjah, north of Dubai, struggled to battle a blaze in a 25-storey tower without equipment to reach the flames. (from a BBC newscast). The fire chief told the reporter, I wish I had equipment to fight this fire

Role of Helicopters in Urban Firefighting Fire Suppression Apply water and foam to areas ground based firefighters can not reach Search & Rescue Evacuate victims from location inaccessible by ground. Resource Deployment Move and deploy equipment and personal free of traffic congestion. Command and Control Provide critical real time information through aerial surveillance to Incident Command. Medical Evacuation Ability to move victims from the scene.

Value An Aerial Fire Truck Rapid Response Keep the Fire Small Give Occupants Time to Exit Give Ground Firefighters Time to Get to the Fire, Set Up, and Fight the Fire Internally

How Fire Destroys a Building 1 The fire starts 2 The fire grows and breaks the windows 3 The fire destroys the building by lapping up the outside of the building

Coordinated Aerial & Ground Fire Attack The helicopter keeps the fire small while ground forces to reach the fire and occupants evacuate 1 Fire starts helicopter deployed rapidly free of traffic congestion 2 Fire breaks the windows but is held inside building by SkyCannon providing victims time to exit the building while retarding the fires growth 3 Ground forces have time to fight the fire internally aided by the SkyCannon

SkyCannon : An Aerial Fire Truck Model 516 (AIRBUS HELICOPTERS H225) FAA and Japanese Certified in 2015 The Model 516 FAA STC: SR02459SE The Model 516 JCAB JSTC: STC.437.TYO Model 316 FAS FAA STC: SR01074SE Model 316 FAS JCAB JSTC: STC.315.OSA

Simplex s SkyCannon : SkyCannon : An Aerial Fire Truck An Aerial Fire Truck Simplex Modular Design Simplex s Aerial Fire Truck Technology Rapid installation Infrared in less Camera than and Laser 15 Distance minutes Measurement HydraFoam Cannon self contained required no aircraft power Fire Attack System can be used independent or with HydraFoam Ca Nozzle Utilize lightweight aviation grade materials Moveable Composite Boom Power Pack Water Tank with Foam System Hover Refill System (or can be removed for ground fill) Information proprietary Proprietary to Simplex Information Aerospace - Not to be reproduced and shall with permission not be from copied Simplex without Aerospaceexpress permission from Simplex 17

Importance of Side Mounted Moveable Boom Allows pilot to position aircraft with a planned escape route Allows pilot to position aircraft for improved handling stability avoiding tail wind impact on the aircraft Boom operated by fire fighter from aircraft cabin reducing pilot work load Boom stows and locks forward for rapid flight to fire Movable boom facilitates firefighting between buildings with limited access Boom articulates side to side 0 to 100 and from horizontal down 25 18

Use of SkyCannon Between Buildings 19

SkyCannon System Performance Less than 20 minute installation and removal for rapid deployment 40 meters horizontal spray measured from tip of rotor blades allowing the pilot to fly at a safe distance from the building and out of the smoke plume Spray volume at 600 liters per minute Hover refill systems for rapid water replenishment close to the fire in less than 60 seconds Ground refillable using standard fire hoses from a fire hydrant or water truck

SkyCannon System Performance Articulating boom permits aircraft positioning independent of boom location avoiding tail wind and allows pilot to plan escape route in case of emergency Integrated infrared camera that tracks with the boom movement Integrated fire foam system increasing firefighting effectiveness and efficiency 7x from water only Joystick controlled boom with all operating controls and infrared display necessary for operation of the system Automatic boom return and storage in Emergency for Safety

Questions?