LETTER OF TRANSMITTAL

Similar documents
Submittal Transmittal

FCC Fan-Coil Units High-Performance, Vertical

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

AIR HANDLER DESIGN WORK SHEET

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

1.1 This section applies to air handling units for HVAC Systems.

PRODUCT CATALOG BLOWER COILS.

C13-Series Engineering Guide

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

Architecture - Engineering - Planning

catalog CDV Fan-Coil Units High-Performance, Vertical

DIRECT DRIVE BLOWER COILS

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Now In Production JULY 2008

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

VariCool VAV Engineering Guide

Modular Supply Make-Up Air Unit

SECTION AIR HANDLING UNIT

Daikin Applied SUBMITTAL FOR APPROVAL. Emergent BioSolutions B16 Formulation HVAC Upgrades. Engineer: IPS. Contractor: AMS

SSL & SBS Engineering Guide

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

XeteX, Inc. All Rights Reserved.

Item Title No. of Copies

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

48PGD/E/F/L/M/N PG20-28

VH Series B ENVIRO-STAC Vertical Hi-Rise Fan Coil Unit with Enhanced Humidity Control

VertiCool Aurora Engineering Guide

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at

KAP Horizontal Product Coolers

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Engineering Guide. Application & Engineering Guide REVOLUTION TFX AIR HANDLING UNITS. 605 Shiloh Road Plano, Texas

Product Specifications. Vertical Floor Consoles By First Co.

TAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

CxA to Answer this Section

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

SUBMITTAL SCHEDULE & DATA

Advance Release September 2009

SECTION FAN COIL UNITS

Technical Development Program

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

University of Delaware

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Ducted Propeller. Airflow Volume

Catalog Destiny Indoor Air Handler. Models Horizontal Configuration. Vertical Configuration

CS 2. Central Station Air Handlers Double Wall & Single Wall Installation, Operation & Maintenance Manual. Form No. 6120A

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

TYPICAL CPA SPECIFICATIONS

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

THE ULTIMATE ROOFTOP SOLUTION

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

DACC Health Sciences Building Air Handler Assessment/Study

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

YAH SERIES FAN COIL UNITS

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

Chilled Water DOAS Fan Powered Terminal Units

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

TESTING, ADJUSTING AND BALANCING

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

VERTICAL FAN COIL UNITS

BUILD YOUR REPUTATION ON OURS. Universal Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG

Technical Assignment 3 11/15/04. Executive Summary

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

EHH SERIES DRAW THROUGH FAN COILS CFM

Appendices. Included in this section are

Architectural Alliance Incorporated MDP CONSULTING ENGINEERS, INC N 11th Street Beaumont, TX 77702

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

ELECTRICAL QUANTITY WEIGHT (LB)

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing


Submittal Summary Page

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

Submittal Data Performance Data Electrical Data

Energy Efficient Easy to Install Extended Service Life. Vertical Direct Drive Blower Coils

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements.

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Plenum Fans. Model HPA. Direct Drive

PAR5. Product Specifications

Transcription:

LETTER OF TRANSMITTAL FRANK A. ANZALONE Date: FAA Job No. 157 GENERAL CONTRACTOR Attention: Mr. Brent Guilbeau - Coleman Partners 1401 Derek Drive, Suite B Hammond, LA 70403 3377 North Boulevard Phone: (985) 542-2744 Baton Rouge, LA 70806 Fax: (985) 230-0614 RE: 157 - Mayfield Elementary School Additions Air Handlers, Energy Recovery Ventilators, ATUs WE ARE SENDING YOU Attached Under Separate Cover Via Shop Drawings Change Order Other Product Data Samples Specifications Prints ITEM NO. COPIES DESCRIPTION 001 1 Central Station Air Handler - Shop Drawings/Data 002 1 Energy Recovery Ventilators - Shop Drawings/Data 003 1 Air Terminal Units THESE ITEMS ARE TRANSMITTED: For Approval For Your Use As Requested Appoved As Submitted Approved As Noted Returned For Correction For Review and Comment Revise and Resubmit REMARKS: Brent: Please see the attached Mechanical Submittals for Review. SIGNED: Wilson Alvarez

SUBMITTAL DATA Henry Mayfield Elementary Equipment Included: (3) York Solution XTI Air Handling Units (8) Enviro-Tech Model HLE,HLP,VHC Fan Coil Units (17) Single Duct Model SDR Variable Air Volume Boxes (33) L.G. Thru-the Wall Terminal Air Conditioning Units Frank A. Anzalone, General Contractor, Inc JOB # FILE DATE REVIEWED BY COMMENTS MADE YES NO APPROVED FOR SUBMITTAL TO ARCHITECT YES NO THIS SUBMITTAL HAS BEEN REVIEWED FOR GENERAL CONFORMANCE WITH CONTRACT DOCUMENTS; VENDOR IS RESPONSIBLE FOR ACCURACY IN ACCORDANCE WITH ALL CONTRACT DOCUMENTS. Prepared For: ARC Mechanical 36408 LA-433 Slidell, LA 70460 Prepared By: Schully Strawn & Assoc. 2839 Hessmer St., Ste 100 Metairie, LA 70002 Date: June 8, 2016

York Solution Model XTI Air Handling Unit General Notes 1. All of the York Solution Model XTI on this project shall be provided with the following: 2 Inch Double Wall Construction Foam Injected Insulation with R Insulation Value of 13 1% Leakage at +/- 8 Inches ESP L/240 Panel Deflection Thermal Break Access Doors (Downstream of Cooling Coil) Belt Drive, Housed Airfoil Fan Wheels on MUA Units 2 Inch Internal Spring Isolation Inverter Duty, Premium Efficiency, ODP Fan Motor Chilled Water Cooling Coil Galvanised Steel Coil Casing 304 Stainless Steel IAQ Drain Pan Filter Section with (2) Sets of 2, 30% MERV-8 Filters, Magnehelic Gauges. 6 Inch Base Rails 60 Month Parts & Labor Warranty Beginning at Startup 2. We are not providing any of the following: Air Flow Measuring Stations Controls or Control Valves 3. All coil hand connection locations, fan discharge arrangements and access door location shall be coordinated with mechanical contractor before release of equipment.

AHU-1 1 Indoor Air Handler 45 x 60 6270 Unit Sequence Tier 2 FS /\ Tier 1 VC <<< XA <<< FF Basic Unit Options Insulation Type: Base Rail Height: Performance: (Refer to Each Segment) 6" Formed Steel High Performance Statement of compliance of standard units. Solution XT AHU's meet IBC seismic requirements for non-critical equipment (Ip = 1.0) for locations with design spectral response Sds <= 0.43. Units must be rigid mounted. The anchorage of the unit to the ground or building structure needs to be evaluated by and is the responsibility of the engineer of record. Specification of seismic requirements is the responsibility of the project design engineer. If formal certification is required, please contact your sales representative and/or application engineer for review. Certain application and site requirements may require additional cost and/or lead time. Unit Special Quotes None *Note:Component locations are listed as Segment Hand (Unit Hand) : ex. Left (Right) See Submittal Drawing for additional details Printed: 4/27/2016 10:33:09 AHU-1Performance Unit Folder: AHU1 4/18/2016 1:33:14 PM Page 1 of 8

AHU-1 1 Indoor Air Handler 45 x 60 6270 Segments Listed Starting At Air Inlet FF Flat Filter Segment Filter Media Detail Filter Segment Options (Quantity)Filter Sizes: (2)24x24; (2)24x12 Interior STD Ga. G-90 Galvanized Liner Filter Loading: Side Insulation: R-13 2" Foam Filter Depth: 2" STD Ga. G-90 Galvanized Floor Liner Filter Media Type: Pleated 30% (MERV 8) Exterior STD Ga. G-90 Galvanized Liner Filter Area (ft²): 12.0 Galvanized Blankoff Material Filter Air Pressure Drop (in. w.g.): 0.29 Access Doors on Both Sides 39H x 10W Dirty Filter Allowance (in. w.g.): 0.25 Standard Door Latch, No Lock, Outward Opening Optimized Filter Arrangement Spare Filter Media: Spare Filter Quantity Set(s): Pleated 30% (MERV 8) 1 XA Access Segment Access Segment Details Access Segment Options Segment Length: 3 " Interior STD Ga. G-90 Galvanized Liner Insulation: R-13 2" Foam STD Ga. G-90 Galvanized Floor Liner Exterior STD Ga. G-90 Galvanized Liner VC Vertical Coil Segment Coil Segment Details Coil Segment Options Coil Space: 10" Interior STD Ga. G-90 Galvanized Liner Insulation: R-13 2" Foam STD Ga. G-90 Galvanized Floor Liner Exterior STD Ga. G-90 Galvanized Liner Coil Pull: None 19" IAQ Drain Pan Left (Left) Stainless Steel Access Doors on Both Sides 39H x 18W Standard Door Latch, No Lock, Outward Opening Bulkhead Material Galvanized Coil Supports Galvanized UV Surface Decontamination Detail None Printed: 4/27/2016 10:33:09 AHU-1Performance Unit Folder: AHU1 4/18/2016 1:33:14 PM Page 2 of 8

AHU-1 1 Indoor Air Handler 45 x 60 6270 FS - Supply Fan Segment Segment Details Fan Segment Options Segment Air Pressure Drop (in. w.g.): 0.00 2" Spring Isolator Air Flow per Fan (CFM): 6270 Osha Belt Guard Air Flow Total (CFM): 6270 Interior STD Ga. G-90 Galvanized Liner Altitude (ft.): 75 Insulation: R-13 2" Foam TSP/ESP (in. w.g.): 2.03/ 1.00 STD Ga. G-90 Galvanized Floor Liner Air Inlet: Bottom Exterior STD Ga. G-90 Galvanized Liner Fan Discharge: Top External Light Switch Access Door on Left Side(Left) 33H x 18W Multi-Point Door Latch, No Lock, Outward Opening Fan Detail Type: AF Size: 15-15 Construction: S Bearing Options: Extended Lube Fan RPM: 2076 BHP: 4.47 Fan BHP w/ Belt Loss: 4.78 Outlet Velocity (ft/min): 2739 Motor Detail (per motor) Motor Type: WEG ODP Premium Efficiency HP 7.5 Voltage/Phase/Frequency: 460/3/60 Hz Insulation Class: F Motor RPM: 1800 Frame Size: 213 Location: Left(Left) Drive Type: Belt Drive Type: Belt Drive Fixed Full Load Amps (FLA): 9.25 Efficiency: 91.0% Printed: 4/27/2016 10:33:09 AHU-1Performance Unit Folder: AHU1 4/18/2016 1:33:14 PM Page 3 of 8

AHU-1 1 Indoor Air Handler 45 x 60 6270 Coils & Spacers Listed Starting In Direction Of Air Flow VC Coil - 01 Coil General/Physical Details Air Side Performance Fluid Side Performance Location: Tag: 0 AirCoil Rows: Fins Per Inch: 6 8 Air Flow (acfm): Altitude (ft.): 6270 75 EWT ( F): LWT ( F): GPM: 45.0 55.0 32.5 Application: Cooling Tubes Per Circuit: 12 EAT-DB ( F): 74.4 WPD (ft): 12.8 Coil Type: Water Finned Height (in.): 35.00 EAT-WB ( F): 62.6 FPS: 4.0 Face Type: Full Finned Length (in.): 48 LAT-DB ( F): 55.3 Fluid Type: Wate Tube Diameter: 1/2" BDW Coil Face Area 11.7 LAT-WB ( F): 53.5 Fluid Weight(lb): r (ft²): Fluid 67.0 Tube Material: Copper Coil Conn. Loc.: Left(Left) FV (ft/min): 536 Volume(ft³): 1.1 Tube Wall Thickness:.016" Supp Conn Size: 2" SMBH: 130.0 Fouling Factor 0.00000 Rtn Conn Size: 2" TMBH: 163.2 (hft² F/btu): Fin Type: Corrugated # of Supply Conn. (per coil): 1 APD (in. w.g.): 0.48 Fin Thickness:.006" Fin Material: Aluminum Casing Material: Galvanized Connection Material: Steel* Connection Type: MPT Coating: None *Johnson Controls suggests using red brass or copper connectors when the coil is to be attached to a copper or brass piping system. Ratings are for coils manufactured by Johnson Controls, Inc., 507 E. Michigan St., Milwaukee WI 53202. BDW Tube Spacing: 1.25" x 1.08" AHRI Messages: This coil is certified in accordance with the AHRI Forced-Circulation Air-Cooling and Air-Heating Coils Certification Program which is based on AHRI Standard 410 within the range of Standard rating conditions listed in Table 1 of the Standard. Certified units may be found in the AHRI Directory at www.ahridirectory.org. Coil Dll Version: 7.3b.003 Static Pressure Summary Segment Component Supply (in. w.g.) Return Fan (in. w.g.) FF Flat Filter VC Vertical Coil 2" Pleated 30% (MERV 8) Dirty Filter Allowance Cooling 6 rows 8 fins Turning Air Pressure Drop 0.29 0.25 0.48 0.01 Printed: 4/27/2016 10:33:09 AHU-1Performance Unit Folder: AHU1 4/18/2016 1:33:14 PM Page 4 of 8

AHU-1 1 Indoor Air Handler 45 x 60 6270 FS-DWDI Supply Fan External Static Pressure - User Entered Pressure Drop 1.00 Total 2.03 0.00 Air handling unit parameters vary depending on conditions. Parameters such as airflows, air pressure drops, and coil capacities are shown for design conditions. Section FF Flat Filter Segment XA Variable Length Access Segment VC Vertical Coil Segment FS-DWDI Supply Fan Segment Dimension & Weights Summary Length* Width** (in.) 13 3 38 - (in.) 60 60 60 60 Height (in.) 45 45 45 39 Weight (lbs.) 267 24 972 904 Overall: 54 60 84 2167 *The length includes bottom tier segments only. **The width does not include coil connection extensions or door latches that extent beyond the unit casing. The width does not include the depth of any pipe chases. Printed: 4/27/2016 10:33:09 AHU-1Performance Unit Folder: AHU1 4/18/2016 1:33:14 PM Page 5 of 8

Shipping Skid (VC XA FF FS-DWDI) SOLUTION XT AIR HANDLING UNIT AHU-1 1 Indoor Air Handler 45 x 60 6270 Shipping Skid Summary Length* Width** Height*** Weight (in.) (in.) (in.) (lbs.) 54 68 95 2167 Ship Loose: None *The length includes any mounted rain-hoods, discharge flanges, tie-down brackets, shipping wood-blocks, front dampers, split connectors, electrical/control components, outrigging extensions, isolation dampers, inlet baskets **The width includes any door handles, coil connections, drain connections, lifting lugs, mounted pipe-chases, electrical/control components, tie-down brackets, side dampers ***The height includes any base-rails, shipping wood-blocks, roof peak, discharge flanges, mounted gas-furnace flue pipes Shipping Skid Sequence Tier 2 Tier 1 FS) /\ VC < XA < FF) Printed: 4/27/2016 10:33:09 AHU-1Performance Unit Folder: AHU1 4/18/2016 1:33:14 PM Page 6 of 8

AHU-1 1 Indoor Air Handler 45 x 60 6270 Sound Summary Octave Band Sound Power Levels (db Re. 1 picowatt) 63 125 250 500 1000 2000 4000 8000 dba Ducted Discharge Top-1, FS 91 91 92 90 87 82 76 71 Return Air INLET, FF 86 83 83 84 79 74 67 60 Sound data tested in accordance with AHRI-260 (2001), Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. Notes: 1. The overall A-weighted sound power level is only applicable to sound radiation outdoors and casing radiated sound. This metric does not apply to ducted components 2. Return air sound powers are estimated using 100% of unit flow. Printed: 4/27/2016 10:33:09 AHU-1Performance Unit Folder: AHU1 4/18/2016 1:33:14 PM Page 7 of 8

AHU-1 1 Indoor Air Handler 45 x 60 6270 Recommended Trap Height Summary Applicable Fan TSP Positive or Calculated Dimensions Recommended Base Rail Segment Fan [in H 2 O] Negative H X H + X H H + X Height VC Supply Fan 2.03" Negative 3.03" 1.51" 4.54" 3.25" 5.00" 6" Notes: Formulas and calculations are recommendations only. Contractor shall determine actual dimensions required for each trap based on jobsite conditions, and application requirements. Refer to section 2 (Installation) of the IOM for more information. Printed: 4/27/2016 10:33:09 AHU-1Performance Unit Folder: AHU1 4/18/2016 1:33:14 PM Page 8 of 8

AHU-2 1 Indoor Air Handler 45 x 63 6320 Unit Sequence Tier 2 FS /\ Tier 1 VC <<< XA <<< FF Basic Unit Options Insulation Type: Base Rail Height: Performance: (Refer to Each Segment) 6" Formed Steel High Performance Statement of compliance of standard units. Solution XT AHU's meet IBC seismic requirements for non-critical equipment (Ip = 1.0) for locations with design spectral response Sds <= 0.43. Units must be rigid mounted. The anchorage of the unit to the ground or building structure needs to be evaluated by and is the responsibility of the engineer of record. Specification of seismic requirements is the responsibility of the project design engineer. If formal certification is required, please contact your sales representative and/or application engineer for review. Certain application and site requirements may require additional cost and/or lead time. Unit Special Quotes None *Note:Component locations are listed as Segment Hand (Unit Hand) : ex. Left (Right) See Submittal Drawing for additional details Printed: 4/27/2016 10:33:29 AHU-2Performance Unit Folder: AHU2 4/18/2016 10:38:03 AM Page 1 of 8

AHU-2 1 Indoor Air Handler 45 x 63 6320 Segments Listed Starting At Air Inlet FF Flat Filter Segment Filter Media Detail Filter Segment Options (Quantity)Filter Sizes: (2)24x24; (2)24x12 Interior STD Ga. G-90 Galvanized Liner Filter Loading: Side Insulation: R-13 2" Foam Filter Depth: 2" STD Ga. G-90 Galvanized Floor Liner Filter Media Type: Pleated 30% (MERV 8) Exterior STD Ga. G-90 Galvanized Liner Filter Area (ft²): 12.0 Galvanized Blankoff Material Filter Air Pressure Drop (in. w.g.): 0.29 Access Door on Left Side(Left) 39H x 10W Dirty Filter Allowance (in. w.g.): 0.25 Standard Door Latch, No Lock, Outward Opening Optimized Filter Arrangement Spare Filter Media: Spare Filter Quantity Set(s): Pleated 30% (MERV 8) 1 XA Access Segment Access Segment Details Access Segment Options Segment Length: 3 " Interior STD Ga. G-90 Galvanized Liner Insulation: R-13 2" Foam STD Ga. G-90 Galvanized Floor Liner Exterior STD Ga. G-90 Galvanized Liner VC Vertical Coil Segment Coil Segment Details Coil Segment Options Coil Space: 10" Interior STD Ga. G-90 Galvanized Liner Insulation: R-13 2" Foam STD Ga. G-90 Galvanized Floor Liner Exterior STD Ga. G-90 Galvanized Liner Coil Pull: None 19" IAQ Drain Pan Left (Left) Stainless Steel Access Doors on Both Sides 39H x 18W Standard Door Latch, No Lock, Outward Opening Bulkhead Material Galvanized Coil Supports Galvanized UV Surface Decontamination Detail None Printed: 4/27/2016 10:33:29 AHU-2Performance Unit Folder: AHU2 4/18/2016 10:38:03 AM Page 2 of 8

AHU-2 1 Indoor Air Handler 45 x 63 6320 FS - Supply Fan Segment Segment Details Fan Segment Options Segment Air Pressure Drop (in. w.g.): 0.00 2" Spring Isolator Air Flow per Fan (CFM): 6320 Osha Belt Guard Air Flow Total (CFM): 6320 Interior STD Ga. G-90 Galvanized Liner Altitude (ft.): 75 Insulation: R-13 2" Foam TSP/ESP (in. w.g.): 1.96/ 1.00 STD Ga. G-90 Galvanized Floor Liner Air Inlet: Bottom Exterior STD Ga. G-90 Galvanized Liner Fan Discharge: Top External Light Switch Access Door on Left Side(Left) 33H x 18W Multi-Point Door Latch, No Lock, Outward Opening Fan Detail Type: AF Size: 15-15 Construction: S Bearing Options: Extended Lube Fan RPM: 2065 BHP: 4.46 Fan BHP w/ Belt Loss: 4.77 Outlet Velocity (ft/min): 2761 Motor Detail (per motor) Motor Type: WEG ODP Premium Efficiency HP 7.5 Voltage/Phase/Frequency: 460/3/60 Hz Insulation Class: F Motor RPM: 1800 Frame Size: 213 Location: Left(Left) Drive Type: Belt Drive Type: Belt Drive Fixed Full Load Amps (FLA): 9.25 Efficiency: 91.0% Printed: 4/27/2016 10:33:29 AHU-2Performance Unit Folder: AHU2 4/18/2016 10:38:03 AM Page 3 of 8

AHU-2 1 Indoor Air Handler 45 x 63 6320 Coils & Spacers Listed Starting In Direction Of Air Flow VC Coil - 01 Coil General/Physical Details Air Side Performance Fluid Side Performance Location: Tag: 0 AirCoil Rows: Fins Per Inch: 6 8 Air Flow (acfm): Altitude (ft.): 6320 75 EWT ( F): LWT ( F): GPM: 45.0 55.0 29.7 Application: Cooling Tubes Per Circuit: 12 EAT-DB ( F): 73.0 WPD (ft): 11.4 Coil Type: Water Finned Height (in.): 35.00 EAT-WB ( F): 61.0 FPS: 3.7 Face Type: Full Finned Length (in.): 51 LAT-DB ( F): 54.4 Fluid Type: Wate Tube Diameter: 1/2" BDW Coil Face Area 12.4 LAT-WB ( F): 52.6 Fluid Weight(lb): r (ft²): Fluid 71.0 Tube Material: Copper Coil Conn. Loc.: Left(Left) FV (ft/min): 510 Volume(ft³): 1.1 Tube Wall Thickness:.016" Supp Conn Size: 2" SMBH: 127.2 Fouling Factor 0.00000 Rtn Conn Size: 2" TMBH: 149.0 (hft² F/btu): Fin Type: Corrugated # of Supply Conn. (per coil): 1 APD (in. w.g.): 0.41 Fin Thickness:.006" Fin Material: Aluminum Casing Material: Galvanized Connection Material: Steel* Connection Type: MPT Coating: None *Johnson Controls suggests using red brass or copper connectors when the coil is to be attached to a copper or brass piping system. Ratings are for coils manufactured by Johnson Controls, Inc., 507 E. Michigan St., Milwaukee WI 53202. BDW Tube Spacing: 1.25" x 1.08" AHRI Messages: This coil is certified in accordance with the AHRI Forced-Circulation Air-Cooling and Air-Heating Coils Certification Program which is based on AHRI Standard 410 within the range of Standard rating conditions listed in Table 1 of the Standard. Certified units may be found in the AHRI Directory at www.ahridirectory.org. Coil Dll Version: 7.3b.003 Static Pressure Summary Segment Component Supply (in. w.g.) Return Fan (in. w.g.) FF Flat Filter VC Vertical Coil 2" Pleated 30% (MERV 8) Dirty Filter Allowance Cooling 6 rows 8 fins Turning Air Pressure Drop 0.29 0.25 0.41 0.01 Printed: 4/27/2016 10:33:29 AHU-2Performance Unit Folder: AHU2 4/18/2016 10:38:03 AM Page 4 of 8

AHU-2 1 Indoor Air Handler 45 x 63 6320 FS-DWDI Supply Fan External Static Pressure - User Entered Pressure Drop 1.00 Total 1.96 0.00 Air handling unit parameters vary depending on conditions. Parameters such as airflows, air pressure drops, and coil capacities are shown for design conditions. Section FF Flat Filter Segment XA Variable Length Access Segment VC Vertical Coil Segment FS-DWDI Supply Fan Segment Dimension & Weights Summary Length* Width** (in.) 13 3 39 - (in.) 63 63 63 63 Height (in.) 45 45 45 39 Weight (lbs.) 278 25 1008 923 Overall: 55 63 84 2234 *The length includes bottom tier segments only. **The width does not include coil connection extensions or door latches that extent beyond the unit casing. The width does not include the depth of any pipe chases. Printed: 4/27/2016 10:33:29 AHU-2Performance Unit Folder: AHU2 4/18/2016 10:38:03 AM Page 5 of 8

Shipping Skid (VC XA FF FS-DWDI) SOLUTION XT AIR HANDLING UNIT AHU-2 1 Indoor Air Handler 45 x 63 6320 Shipping Skid Summary Length* Width** Height*** Weight (in.) (in.) (in.) (lbs.) 55 71 95 2234 Ship Loose: None *The length includes any mounted rain-hoods, discharge flanges, tie-down brackets, shipping wood-blocks, front dampers, split connectors, electrical/control components, outrigging extensions, isolation dampers, inlet baskets **The width includes any door handles, coil connections, drain connections, lifting lugs, mounted pipe-chases, electrical/control components, tie-down brackets, side dampers ***The height includes any base-rails, shipping wood-blocks, roof peak, discharge flanges, mounted gas-furnace flue pipes Shipping Skid Sequence Tier 2 Tier 1 FS) /\ VC < XA < FF) Printed: 4/27/2016 10:33:29 AHU-2Performance Unit Folder: AHU2 4/18/2016 10:38:03 AM Page 6 of 8

AHU-2 1 Indoor Air Handler 45 x 63 6320 Sound Summary Octave Band Sound Power Levels (db Re. 1 picowatt) 63 125 250 500 1000 2000 4000 8000 dba Ducted Discharge Top-1, FS 91 91 92 90 87 82 76 71 Return Air INLET, FF 86 83 83 84 79 74 67 60 Sound data tested in accordance with AHRI-260 (2001), Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. Notes: 1. The overall A-weighted sound power level is only applicable to sound radiation outdoors and casing radiated sound. This metric does not apply to ducted components 2. Return air sound powers are estimated using 100% of unit flow. Printed: 4/27/2016 10:33:29 AHU-2Performance Unit Folder: AHU2 4/18/2016 10:38:03 AM Page 7 of 8

AHU-2 1 Indoor Air Handler 45 x 63 6320 Recommended Trap Height Summary Applicable Fan TSP Positive or Calculated Dimensions Recommended Base Rail Segment Fan [in H 2 O] Negative H X H + X H H + X Height VC Supply Fan 1.96" Negative 2.96" 1.48" 4.44" 3.00" 4.50" 6" Notes: Formulas and calculations are recommendations only. Contractor shall determine actual dimensions required for each trap based on jobsite conditions, and application requirements. Refer to section 2 (Installation) of the IOM for more information. Printed: 4/27/2016 10:33:29 AHU-2Performance Unit Folder: AHU2 4/18/2016 10:38:03 AM Page 8 of 8

AHU-1 Gym 1 Indoor Air Handler 60 x 78 10350 Unit Sequence Tier 2 FS /\ Tier 1 VC <<< XA <<< FF Basic Unit Options Insulation Type: Base Rail Height: Performance: (Refer to Each Segment) 6" Formed Steel High Performance Statement of compliance of standard units. Solution XT AHU's meet IBC seismic requirements for non-critical equipment (Ip = 1.0) for locations with design spectral response Sds <= 0.43. Units must be rigid mounted. The anchorage of the unit to the ground or building structure needs to be evaluated by and is the responsibility of the engineer of record. Specification of seismic requirements is the responsibility of the project design engineer. If formal certification is required, please contact your sales representative and/or application engineer for review. Certain application and site requirements may require additional cost and/or lead time. Unit Special Quotes None *Note:Component locations are listed as Segment Hand (Unit Hand) : ex. Left (Right) See Submittal Drawing for additional details Printed: 4/27/2016 10:33:48 AHU-1 GymPerformance Unit Folder: AHUGYM 4/25/2016 9:48:08 AM Page 1 of 9

AHU-1 Gym 1 Indoor Air Handler 60 x 78 10350 Segments Listed Starting At Air Inlet FF Flat Filter Segment Filter Media Detail Filter Segment Options (Quantity)Filter Sizes: (4)24x24; (2)20x24 Interior STD Ga. G-90 Galvanized Liner Filter Loading: Side Insulation: R-13 2" Foam Filter Depth: 2" STD Ga. G-90 Galvanized Floor Liner Filter Media Type: Pleated 30% (MERV 8) Exterior STD Ga. G-90 Galvanized Liner Filter Area (ft²): 22.7 Galvanized Blankoff Material Filter Air Pressure Drop (in. w.g.): 0.23 Access Door on Left Side(Left) 54H x 10W Dirty Filter Allowance (in. w.g.): 0.25 Standard Door Latch, No Lock, Outward Opening Optimized Filter Arrangement Spare Filter Media: Spare Filter Quantity Set(s): Pleated 30% (MERV 8) 1 XA Access Segment Access Segment Details Access Segment Options Segment Length: 3 " Interior STD Ga. G-90 Galvanized Liner Insulation: R-13 2" Foam STD Ga. G-90 Galvanized Floor Liner Exterior STD Ga. G-90 Galvanized Liner Printed: 4/27/2016 10:33:48 AHU-1 GymPerformance Unit Folder: AHUGYM 4/25/2016 9:48:08 AM Page 2 of 9

AHU-1 Gym 1 Indoor Air Handler 60 x 78 10350 VC Vertical Coil Segment Coil Segment Details Coil Segment Options Coil Space: 10" Interior STD Ga. G-90 Galvanized Liner Insulation: R-13 2" Foam STD Ga. G-90 Galvanized Floor Liner Exterior STD Ga. G-90 Galvanized Liner 0" Downspout Coil Pull: None 19" IAQ Drain Pan Left (Left) Stainless Steel Access Doors on Both Sides 54H x 18W Standard Door Latch, No Lock, Outward Opening Bulkhead Material Galvanized Coil Supports Galvanized UV Surface Decontamination Detail None Printed: 4/27/2016 10:33:48 AHU-1 GymPerformance Unit Folder: AHUGYM 4/25/2016 9:48:08 AM Page 3 of 9

AHU-1 Gym 1 Indoor Air Handler 60 x 78 10350 FS - Supply Fan Segment Segment Details Fan Segment Options Segment Air Pressure Drop (in. w.g.): 0.00 2" Spring Isolator Air Flow per Fan (CFM): 10350 Osha Belt Guard Air Flow Total (CFM): 10350 Interior STD Ga. G-90 Galvanized Liner Altitude (ft.): 75 Insulation: R-13 2" Foam TSP/ESP (in. w.g.): 2.55/ 1.50 STD Ga. G-90 Galvanized Floor Liner Air Inlet: Bottom Exterior STD Ga. G-90 Galvanized Liner Fan Discharge: Top External Light Switch Access Door on Left Side(Left) 45H x 18W Multi-Point Door Latch, No Lock, Outward Opening Fan Detail Type: AF Size: 20-20 Construction: S Bearing Options: Extended Lube Fan RPM: 1592 BHP: 6.54 Fan BHP w/ Belt Loss: 6.90 Outlet Velocity (ft/min): 2185 Motor Detail (per motor) Motor Type: WEG ODP Premium Efficiency HP 10.0 Voltage/Phase/Frequency: 460/3/60 Hz Insulation Class: F Motor RPM: 1800 Frame Size: 215 Location: Left(Left) Drive Type: Belt Drive Type: Drive Options: Belt Drive Fixed Multiple Belt Full Load Amps (FLA): 12.40 Efficiency: 91.7% Printed: 4/27/2016 10:33:48 AHU-1 GymPerformance Unit Folder: AHUGYM 4/25/2016 9:48:08 AM Page 4 of 9

AHU-1 Gym 1 Indoor Air Handler 60 x 78 10350 Coils & Spacers Listed Starting In Direction Of Air Flow VC Coil - 01 Coil General/Physical Details Air Side Performance Fluid Side Performance Location: Tag: 0 AirCoil Rows: Fins Per Inch: 6 10 Air Flow (acfm): Altitude (ft.): 10350 75 EWT ( F): LWT ( F): GPM: 45.0 55.0 71.0 Application: Cooling Tubes Per Circuit: 8 EAT-DB ( F): 75.4 WPD (ft): 11.7 Coil Type: Water Finned Height (in.): 50.00 EAT-WB ( F): 63.6 FPS: 4.1 Face Type: Full Finned Length (in.): 66 LAT-DB ( F): 52.5 Fluid Type: Wate Tube Diameter: 1/2" BDW Coil Face Area 22.9 LAT-WB ( F): 51.5 Fluid Weight(lb): r (ft²): Fluid 140.0 Tube Material: Copper Coil Conn. Loc.: Left(Left) FV (ft/min): 452 Volume(ft³): 2.2 Tube Wall Thickness:.016" Supp Conn Size: 3" SMBH: 257.5 Fouling Factor 0.00000 Rtn Conn Size: 3" TMBH: 357.0 (hft² F/btu): Fin Type: Corrugated # of Supply Conn. (per coil): 1 APD (in. w.g.): 0.56 Fin Thickness:.008" Fin Material: Aluminum Casing Material: Galvanized Connection Material: Steel* Connection Type: MPT Coating: None *Johnson Controls suggests using red brass or copper connectors when the coil is to be attached to a copper or brass piping system. Ratings are for coils manufactured by Johnson Controls, Inc., 507 E. Michigan St., Milwaukee WI 53202. BDW Tube Spacing: 1.25" x 1.08" AHRI Messages: This coil is certified in accordance with the AHRI Forced-Circulation Air-Cooling and Air-Heating Coils Certification Program which is based on AHRI Standard 410 within the range of Standard rating conditions listed in Table 1 of the Standard. Certified units may be found in the AHRI Directory at www.ahridirectory.org. Coil Dll Version: 7.3b.002 Static Pressure Summary Segment Component Supply (in. w.g.) Return Fan (in. w.g.) FF Flat Filter VC Vertical Coil 2" Pleated 30% (MERV 8) Dirty Filter Allowance Cooling 6 rows 10 fins Turning Air Pressure Drop 0.23 0.25 0.56 0.01 Printed: 4/27/2016 10:33:48 AHU-1 GymPerformance Unit Folder: AHUGYM 4/25/2016 9:48:08 AM Page 5 of 9

AHU-1 Gym 1 Indoor Air Handler 60 x 78 10350 FS-DWDI Supply Fan External Static Pressure - User Entered Pressure Drop 1.50 Total 2.55 0.00 Air handling unit parameters vary depending on conditions. Parameters such as airflows, air pressure drops, and coil capacities are shown for design conditions. Section FF Flat Filter Segment XA Variable Length Access Segment VC Vertical Coil Segment FS-DWDI Supply Fan Segment Dimension & Weights Summary Length* Width** (in.) 13 3 46 - (in.) 78 78 78 78 Height (in.) 60 60 60 51 Weight (lbs.) 378 31 1567 1447 Overall: 62 78 111 3423 *The length includes bottom tier segments only. **The width does not include coil connection extensions or door latches that extent beyond the unit casing. The width does not include the depth of any pipe chases. Printed: 4/27/2016 10:33:48 AHU-1 GymPerformance Unit Folder: AHUGYM 4/25/2016 9:48:08 AM Page 6 of 9

AHU-1 Gym 1 Indoor Air Handler 60 x 78 10350 Shipping Skid (VC XA FF) (FS-DWDI) Shipping Skid Summary Length* Width** (in.) 62 57 (in.) 87 83 Height*** (in.) 70 56 Weight (lbs.) 1976 1447 Ship Loose: None *The length includes any mounted rain-hoods, discharge flanges, tie-down brackets, shipping wood-blocks, front dampers, split connectors, electrical/control components, outrigging extensions, isolation dampers, inlet baskets **The width includes any door handles, coil connections, drain connections, lifting lugs, mounted pipe-chases, electrical/control components, tie-down brackets, side dampers ***The height includes any base-rails, shipping wood-blocks, roof peak, discharge flanges, mounted gas-furnace flue pipes Shipping Skid Sequence Tier 2 Tier 1 (FS) /\ (VC < XA < FF) Printed: 4/27/2016 10:33:48 AHU-1 GymPerformance Unit Folder: AHUGYM 4/25/2016 9:48:08 AM Page 7 of 9

AHU-1 Gym 1 Indoor Air Handler 60 x 78 10350 Sound Summary Octave Band Sound Power Levels (db Re. 1 picowatt) 63 125 250 500 1000 2000 4000 8000 dba Ducted Discharge Top-1, FS 89 90 93 88 85 78 73 68 Return Air INLET, FF 84 79 83 79 75 71 65 59 Sound data tested in accordance with AHRI-260 (2001), Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. Notes: 1. The overall A-weighted sound power level is only applicable to sound radiation outdoors and casing radiated sound. This metric does not apply to ducted components 2. Return air sound powers are estimated using 100% of unit flow. Printed: 4/27/2016 10:33:48 AHU-1 GymPerformance Unit Folder: AHUGYM 4/25/2016 9:48:08 AM Page 8 of 9

AHU-1 Gym 1 Indoor Air Handler 60 x 78 10350 Recommended Trap Height Summary Applicable Fan TSP Positive or Calculated Dimensions Recommended Base Rail Segment Fan [in H 2 O] Negative H X H + X H H + X Height VC Supply Fan 2.55" Negative 3.55" 1.77" 5.32" 3.75" 5.75" 6" Notes: Formulas and calculations are recommendations only. Contractor shall determine actual dimensions required for each trap based on jobsite conditions, and application requirements. Refer to section 2 (Installation) of the IOM for more information. Printed: 4/27/2016 10:33:48 AHU-1 GymPerformance Unit Folder: AHUGYM 4/25/2016 9:48:08 AM Page 9 of 9