P/N CC-100. Coolant Circulator. Operation manual

Similar documents
Cool IR. Model C104 - Cooling System. Instruction Manual

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Please Read and Save These Instructions.

Inline Heater for Solvent or Gas. Installation and Operation Manual

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

FLCH4R Garage and Utility Electric Heater

RK/ RK Oxygen Detector Operator s Manual

RK Carbon Monoxide Transmitter Operator s Manual

Citation Models #2001, 2001ST, 2001BN Instruction Manual

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

EXC-450 User s Manual

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Tox-COMB/ANA Combustible Gas Transmitter Operator s Manual

RK/ RK Oxygen Detector Operator s Manual

2001 Smith Eastern Corporation

CH250 AND CH251 CHILLERS

Dear Valued Customer:

MIGHTY PRO 1/4 HP CHILLER

OPERATING MANUAL BFS-MP SERIES FREEZING STAGES

RK-05 Combustible Gas Transmitter Operator s Manual

Installation Guide. For Models: E-MLV36BNK4LK1 E-MLV36ESP4LK1 E-MLV36WW4LK1 READ THESE INSTRUCTIONS AND AND SAVE THEM FOR FUTURE USE

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM

RK CO 2 Transmitter Operator s Manual

THERMAL SYSTEMS, INC. Installation and Operation Manual

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

Manual for MC37/MFC3600

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

CHILLER. Operator s & Installation Manual

WL User Manual. Innovative Technology for a Connected World. global solutions: local support TM

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

INSTALLATION MANUAL. Series 322 Ice Cube Machine SPECIFICATIONS UNPACKING. Series 322 Ice Cube Machine Installation Instructions

Installation Instruction. Puritan Bennett. Wall Air Water Trap For 800 Series Ventilator Basic Cart. Pla

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

RK-03 Hydrogen Detector Operator s Manual

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

Desiccant / Pump Dehumidification System. Model Operating Manual

Carbon Dioxide Sample-Draw Detector Operator s Manual

Manual for MC21A SETUP INSTRUCTIONS

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

Manual for MC91 SETUP INSTRUCTIONS

RTE-5/5B & RTE-9/9B Refrigerated Bath Circulators. NESLAB Manual P/N Installation, Operation and Service Manual

RK / RK CO 2 Detector Operator s Manual

RK / RK Methane Detector Operator s Manual

Manual update 2016 MC37/MFC3600

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

Whole House Filter Model: WH-LD

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

RP, GP, XP Pro Series Installation Instructions

SPECIFICATIONS FEATURES

DURANGO 12V Heater HF

Drain Tempering Reservoir READ & SAVE THESE INSTRUCTIONS. Installation, Operation, & Maintenance. TRION

Cincinnati, OH USA

gamma pond Ultraviolet Sterilizers

MODEL 7000 SUCTION UNIT

RK Carbon Monoxide Transmitter Operator s Manual

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

FTC-350A. ual. Instruction and Operation Manual. Thermo NESLAB Manual P/N Rev. 11/08/00

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

KD-CLN-LP200 Ultrasonic Vinyl Record Cleaner User s Manual English v1.2 Printed in Korea

RK-CH4-4 Combustible Gas Transmitter Operator s Manual

E1.5 ELECTRIC FAN HEATER

METS MODEL E-106. (115 VAC, 60 Hz) USER S MANUAL INSTALLATION OPERATION MAINTENANCE

RK Carbon Monoxide Transmitter Operator s Manual

RK/ RK Carbon Monoxide Detector Operator s Manual

WARMING AND MERCHANDISING CABINET

RK Hydrogen Sulfide Transmitter Operator s Manual

Instruction Manual. Cheese Warmer with Pump

Combustible Gas Sample-Draw Detector Operator s Manual

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

IN020 Rev F Page 1 of 8

MP-MBA-45T-1/60T-1 / 75T-1

RK-02 Multi Point Detector Operator s Manual

DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS

Rules for Safe Operation

40E ELECTRIC FAN HEATER

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

CT-7 Series Toxic Gas Transmitter Operator s Manual

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

18E ELECTRIC FAN HEATER

CH750, CH751 & CH951 CHILLERS

USER S OPERATING AND INSTRUCTION MANUAL

Installation & Operating Instructions

CHILLER. Operator s & Installation Manual

HX-900 Recirculating Chiller

Installation Guide. For Models: E-DCF52BNK5C3 E-DCF52FBZ5C3 E-DCF52MWW5C3 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

SAFETY OPERATION & MAINTENANCE MANUAL X-405 CARPET EXTRACTOR This unit is intended for commercial use.

DISCOVERY Instruction Manual Model #2556

Installation Instructions

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR MODEL RH REMOTE HORIZONTAL AIR COOLED HEAT EXCHANGERS


Installation Instructions

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

TORRID MARINE YACHT QUALITY Since Owner s Manual

Instruction Manual. Nacho Cheese Dispenser and Warmer

SECTION 1D ENGINE COOLING

Instruction Manual. Double Candy Apple Cooker

Installation Guide. For Models: E-PD52ABZ5C4 E-PD52BP5C4 E-PD52WW5C4 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

Transcription:

P/N 4411-0019 CC-100 Coolant Circulator Operation manual Manual Version 1 Revision B July 1, 1998

Table of Contents Chapter 1 Introduction... 5 Description...5 Specifications...5 Chapter 2 Warnings... 7 Introduction...7 Chapter 3 Installation... 9 Inspection...9 Spare Parts Bag...9 Connections and Checks...9 Chapter 4 Maintenance... 11 Air Filter...11 Coolant...11 Coolant Pump...11 Schematic Diagrams...11 Warranty and Service... 15 Warranty...15 Equipment Repairs...15 Contact Information...16 iii

Introduction Chapter 1 Description Specifications The Model CC-100 Coolant Circulator is a universal water-to-air heat exchanger. It transfers heat from any heat source into the air. It was designed primarily for removing heat from thermoelectrically cooled CCD cameras. A magnetic drive coolant pump circulates coolant to the CCD camera (or any other heat source). This coolant passes through the hot side of the camera, which raises the temperature of the coolant. The heated coolant is then returned to the radiator of the CC-100. An internal fan forces air through the radiator reducing the temperature of the coolant by convection. The coolant then returns to the pump and repeats the cycle. This efficient closed cycle process can maintain the temperature of the coolant within a few degrees above ambient temperature. Note: All test data and specifications shown are based on pumping water and are guidelines only. Specifications will vary depending on specific fluid, temperatures, and other operating conditions. Coolant: Water, water/ethylene glycol (50% solution), automotive antifreeze and other inert liquids with viscosity approximately that of water. Capacity: Approximately 0.9 quart (0.85 liter), exclusive of external coolant lines and device to be cooled. Pressure and Flow Maximum head pressure 13 feet (4 meters), 6.38 PSI (44 kpa), with zero flow. Maximum flow is 5 gallons per minute (19 liters/min) with zero head pressure. A flow rate of 1 gallon per minute (3.8 liters/min at 5 PSI (34.5 kpa). In a typical application with 20 feet (6 meters) of 3/16 (4.76 mm) I.D. polyurethane tube, and 8 Swagelock quick connect connectors. The flow rate will be 1 pint per minute (0.5 liters/min). In a typical application with 20 feet (6 meters) of 3/16 (4.78mm) I.D. polyurethane tube with only tube connectors. The flow rate will be 1 quart per minute (0.95 l/min). 5

6 CC-100 Coolant Circulator Manual Version 1.B Cooling Capacity Temperature rises approximately 0.03 C per watt (3.4 btu/hr). Based on a typical flow rate of between 0.5 (0.47 liter) to 1 quart (0.95 liter) per minute and a thermal load of 100 watts (341 btu/hr). When using a CC-100 to cool a PI detector, the coldest attainable temperature should be reduced by no more than two degrees compared with using tap water at ambient temperature. Operating Environment Temperature Minimum: 0 F (-18 C). Avoid freezing coolant. Maximum: 120 F (49 C). Humidity: Avoid condensation Clearance Front: 6 inches (150 mm) minimum Rear: 12 inches (300 mm) minimum Side: 1 inch (20 mm) minimum Power Requirements: 50/60 Hz 2 A @ 105V to 125V AC (standard) 2 A @ 90V to 110 V AC (factory installed option) 1 A @ 210 V to 250 V AC (factory installed option) Mechanical Dimensions D, W, H: 12½ 318mm) 15¾ (400mm) 8¼ (210 mm) Weight (without coolant) 16 lb (7.3 kg) without transformer, standard 19 lb (8.6 kg) with optional transformers for either 100V or 230V AC operation Fluid Interface Two ¼ female NPT tapped threads provided at the Inlet and Outlet on the rear panel. Two ¼ male NPT connectors to ¼ swage tube fittings with two 3 (76mm) by ¼ OD copper tubes provided standard. Two ¼ plastic Swagelock tube plugs are provided standard. Options Tube accessory kit with eight Swagelock quick disconnect connectors and 20 feet (6 m) of polyurethane tubing ¼ OD by 3/16 ID.

Warnings Chapter 2 Introduction This chapter contains cautions and notes concerning initial setup and operation of your system. Of course, reading this section should not replace reading the entire manual. The rest of the manual contains complete procedures for installing and operating your system, as well as a more detailed explanation of the following warnings Verify that the line voltage and fuse ratings are compatible before turning on the system. Voltage applied outside the range may damage the apparatus! The line voltage is not selectable. The unit must be modified at the factory for the desired operating voltage. The Model number on the rear panel indicates the line voltage with which this unit is designed to operate. The Model CC100-115V may be used for line voltages between 105 and 125 V AC, 50 or 60 Hz. The Model CC100-230 V may be used for line voltages between 210 and 250 V AC, 50 or 60 Hz. The Model CC100-100V may be used for line voltages between 90 and 100 V AC, 50 to 60 Hz. The fuse ratings are labeled on the rear panel, except Model CC100-100V. For the CC100-100V the fuse rating is 2 A at 120V AC. Protective grounding must be maintained. Protective grounding could become ineffective in apparatus possibly damaged during shipping. Until safety has been verified by Princeton Instruments, Inc, such damaged apparatus should not be used. Tag the unit appropriately to warn any potential user of such a danger. CAUTION A socket outlet provided with the necessary earth ground contact must be used. Any extension cord or adapters used must also comply with these safety requirements. If the supplied cord plug is not compatible with the power socket, a substitute plug of a compatible design should replace it. Replacement power cords or power plugs must have the same polarity as those of the original equipment to avoid hazard due to electrical shock. Disconnecting the protective earth terminal inside or outside the apparatus is prohibited. Never run the CC-100 without coolant in the reservoir. Although the magnetic pump can withstand short intervals of operation without coolant, doing so will shorten the life of the pump. 7

8 CC-100 Coolant Circulator Manual Version 1.B CAUTION Never allow coolant to freeze. For storage, shipping and operating, a mixture of water/antifreeze or equivalent should be used to prevent freezing and corrosion. Any commercial brand antifreeze, recommended for automotive use, may be used in the CC- 100. It is especially important to prevent freezing during shipping, since the temperature to which the CC-100 will be exposed will not be under control. Since it is very difficult to drain the CC-100 completely, it is strongly advised to fill with an antifreeze solution of sufficient concentration to prevent freezing. Circulate coolant solution for at least five minutes prior to draining in preparation for shipment. Do not operate the unit with the top cover removed. The fan blades are exposed inside the CC-100. Primarily, personal injury will result if the operator comes in contact with the rotating fan blades. Secondarily, running the CC-100 with the covers removed prohibits air flow through the radiator. The temperature of the coolant will rise, since there will be no exchange of heat between the coolant and the air. The rise in temperature may not damage the CC-100, but may overheat and cause damage to the device that is being cooled. Check all coolant hoses and connectors for leaks. Although the unit is tested for leaks at the factory, a visual check for leaks should be made whenever the top cover is removed. If you observe any coolant leakage, turn off the CC-100 at once. Any leakage inside the CC-100 is an electrical hazard and should be repaired prior to use. Do not pressurize the coolant system. The maximum pressure generated inside of the CC-100 is 6 PSI ( 41.4 kpa). There should be zero pressure in the system when the CC-100 is not in operation. Applying any external pressure to the system is not recommended and will void the warranty. There is no coolant flow indication or protection. It is recommended that the user sense coolant flow and provide protection to the device being cooled, if coolant flow is interrupted. Do not operate the system using 100% ethylene glycol. A high concentration solution is not able to carry away the heat created by the detector. A 50% solution is recommended. During shipment spare parts are taped inside of the CC-100 to the top support bracket. These parts must be removed prior to applying power to the unit.

Installation Chapter 3 Inspection Spare Parts Bag When unpacking the CC-100, it should be inspected for any obvious shipping damage. Any shipping damage noted should be reported without delay to both the carrier and to Princeton Instruments, Inc., before operating the system. In case of shipping damage, all shipping material should be saved. Princeton Instruments, Inc. and the shipping carrier should be notified immediately. Otherwise Princeton Instruments, Inc. will consider the damage due to abuse. If external damage is unnoticeable, but system specifications are not met, internal damage has probably occurred. Remove the top cover of the CC-100 by removing the four screws and washers from each side of the top cover. Remove the package of spare parts containing the copper tubes, nuts, etc. from the inside of the CC-100. Inspect inside the instrument for internal damage. Again, in case of shipping damage, all shipping material should be saved. Princeton Instruments, Inc. and the shipping carrier should be notified immediately. Otherwise Princeton Instruments, Inc. will consider damage as due to abuse. Connections and Checks Make all the coolant plumbing connections between the CC-100 and the device to be cooled. Remove the lid from the reservoir and fill it with a water/antifreeze mixture of sufficient concentration to prevent freezing. Be careful not to spill any coolant inside of the instrument. Turn the power on and allow the coolant to circulate. Refill the reservoir as required until all the air is out of the system DO NOT OVERFILL the reservoir. Tighten the lid onto the reservoir. Check for both internal and external leaks. Generally, four or five minutes of operation should be sufficient to determine if any leaks are present. Turn the power off. Place the plastic tube plugs in a bag and secure inside the chassis (these parts will be needed if you have to return the instrument for repair). Install the top cover and 9

10 CC-100 Coolant Circulator Manual Version 1.B secure it with the eight screws and washers removed above. Installation is now complete.

Maintenance Chapter 4 Air Filter Coolant The frequency of cleaning depends on the environment around the CC-100. Usually, whenever the velocity of air coming out of the CC-100 decreases, it is time to clean the filter. Another indication is the rise in the outlet temperature above ambient. Normally this temperature will be within a few degrees of ambient. The air filter is located in front of the radiator. The easiest way of cleaning the filter is to vacuum it from the outside without any disassembly of the CC-100. If this is not possible, the filter can be cleaned by removing the top cover, removing the brackets holding the radiator in place, tilting the top of the radiator away from the rear panel and removing the air filter. Once the filter is removed, wash out the filter with tap water and allow it to dry before reinstalling it. The antifreeze coolant needs to be maintained annually. A complete flush and refill is recommended per instructions on the particular brand of antifreeze selected. Coolant Pump The top cover needs to be removed every six months and the pump oiled. The name plate on the pump indicates the type of oil and the location for lubrication. Apply two or three drops of oil into each location, essentially any type of S.A.E. 20 electric-motor oil can be used. 11

12 CC-100 Coolant Circulator Manual Version 1.B Schematic Diagrams Figure 1. Flow diagram. Figure 2. 115 V Chassis Wiring diagram.

Chapter 4 Tips and Tricks 13 Figure 3. 100 V Chassis Wiring diagram.

14 CC-100 Coolant Circulator Manual Version 1.B Figure 4. 230 V chassis wiring.

Warranty and Service Warranty This equipment is warranted to be free from defects of material and workmanship. It is sold subject to the mutual agreement that the liability of Princeton Instruments, Inc., is limited to replacing defective parts and/or repairing malfunctioning equipment at its factory, provided the equipment is returned, transportation prepaid, within twelve (12) months of its factory ship date. The purchaser agrees that Princeton Instruments, Inc. shall assume no liability for consequential damages resulting from its use or from packaging of shipments returned to the factory. Components which are damaged by misuse are not warranted. Units which have been modified by a customer are not warranted. UV coatings are not covered by this warranty. Equipment Repairs It is recommended that units requiring service in the United States be returned to the factory located in Trenton, New Jersey. Before instrumentation is returned for service, please consult a service engineer at the factory. In many cases, the problem may be cleared up over the telephone. If the unit needs to be returned, the service engineer will ask for a detailed explanation of the problems encountered and a purchase order to cover any charges. You will then receive a Returned Materials Authorization (RMA) number. Place this number on the package so the returned equipment can be easily identified when received at the factory. You must also include with the equipment a completed RMA form explaining the symptoms or problems encountered. Without this document, repair turnaround time will be considerably longer. It is especially important to prevent freezing during shipping, because the temperature to which the CC-100 will be exposed will not be under control. Since it is very difficult to drain the CC-100 completely, it is strongly advised to fill with an antifreeze solution of sufficient concentration to prevent freezing and allowed to circulate for at least five minutes prior to draining in preparation for shipment. Before shipping the unit, the plastic tube plugs should be installed on both the inlet and outlet tube fittings to prevent leakage and possible additional damage. If the unit is under warranty, the customer is only responsible for the transportation and insurance charges to Princeton Instruments. Princeton Instruments is responsible for the return transportation charges. If the unit is out of warranty, the customer is responsible for all transportation charges (including insurance and duty fees, when applicable) as 15

16 CC-100 Coolant Circulator Manual Version 1.B well as all charges incurred to perform the repairs. In this case, the customer can decide the insurance value. International customers should contact your local manufacturers representative or distributor for repair information. Contact Information Princeton Instrument s manufacturing facility is located at the following address: Princeton Instruments, Inc. 3660 Quakerbridge Road Trenton, NJ 08619 (USA) Tel: 609-587-9797 Fax: 609-587-1970 Tech Support E-mail: techsupport@prinst.com For technical support and service outside the United States, see our web page at www.prinst.com. An up-to-date list of addresses, telephone numbers, and e-mail addresses of Princeton Instrument s overseas offices and representatives is maintained on the web page.