Moisture Analyser. User Manual PCE-PMI 1

Similar documents
Manual Hygrometer PCE-555

Manual Vane Anemometer PCE-VA 20

Manual Ultrasonic Cleaner PCE-UC Series

Model ST-128M Moisture Detector

User's Guide. Pinless Moisture Meter. Model MO257

Manual GPRS Data Logger PCE-GPRS 2

CDL 210. Operating manual. CO2 Logger. Best.-Nr

WIRELESS THERMO-HYGROMETER Instructions manual Cat. No. WS9070IT+

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

Instructions for use HYDROMETER Hydrometer GM-200 #071054

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

USER GUIDE Heat Index Psychrometer

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

User's Guide. Pinless Moisture Meter. Model MO257

Indoor/Outdoor Temperature Alert

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

Timer Wall Clock. Model: WT-8100U Quick Setup Guide BUTTONS

USER GUIDE. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester. Model VFM200

ELECTRICAL. Stud Detector User Guide

INSTRUCTION MANUAL WT 498S Radio Controlled Alarm Clock with Temperature and Calendar

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

CALIBRATABLE 7-FUNCTION THERMO- HYGROMETER USER S MANUAL

Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

SGA71. Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG

QUICK START. FLIR Model MR59. Ball Probe Moisture Meter with Bluetooth

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

Water Tank Level Monitor

USER MANUAL Digital CO Monitor Model CO30

4-in-1 Humidity, Temperature Airflow and Light Meter

Digital Electronic Thermostat With RF

Portable type of Carbon Dioxide Detector Model: GT220

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

R2310. Infrared Thermometer. Instruction Manual

Desktop Dual-band Radio Controlled Clock with Melody Alarm and Backlight Model: RM926 User Manual

This is to certify that the optical output of the: SENSORNET LR-DTS Temperature Sensing System: (Variants Mark 1, Mark 2a and Mark 2b)

Pocket Moisture Meter Instruction Manual

The Vitro-i. Radiant / Convector Combination Heater. Instructions for Operation and Installation

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

Non-Touch Thermometer. User Manual. ARC Devices Ltd.

Weather Station Wetterstation

LaserPoint srl - Via Burona, Vimodrone (Milano) - Italy Phone Telefax

Installation and user manual

Digital Electronic Thermostat With RF

Dual Laser InfraRed (IR) Thermometer

testo 315-1/2 Instruction manual 99 Washington Street Melrose, MA Phone Toll Free

Room thermostats with LCD RDD100..

WIRELESS FORECAST STATION

Forehead Thermometer Instruction Manual

NON-TOUCH THERMOMETER User Manual

Glass Kettle. Pour la version française veuillez consulter notre site de web

DIGITAL KITCHEN SCALE

PORTABLE AIR CONDITIONER (LOCAL)

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

Wireless Color Weather Station

WEATHER FORECASTER WITH IN/OUT THERMO RADIO-CONTROLLED COLOR PROJECTION CLOCK - Ref.: RPM OWNER S MANUAL -

Manual PCE-889 pyrometer

PORTABLE AIR CONDITIONER (LOCAL)

AlcoBlow. User Handbook

RECHARGEABLE CLIPPER LI ION RECHARGEABLE CLIPPER INSTRUCTIONS

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

Thermo-/Hygrometer with Mould Alert Model WS 1500 Operating Manual

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

Weather Station with Remote Control Model: BAR289

Visit us at

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Premium Coffee Maker With Integrated Grinder

MOONPHASE WALL CLOCK Instruction Manual

Wöhler CM 220. Carbon Monoxide Meter. The Measure of Technology. Contents. 1. Important information Specification... 13

2 IN 1 JUICER AND BLENDER

OILTESTER - Deep-frying Oil Tester. Instruction manual

Adtemp TM V 418N Digital Fever Thermometer USE, CARE & MAINTENANCE

AUSTRALIA PAD1200-XE NEW ZEALAND

JUNEAU JUN. 08/51193/0 Issue 0

u Do not use the appliance if any part is damaged or defective. u Do not short battery terminals. u Do not charge batteries.

Room thermostat with Auto Timer, Option External Input

USER MANUAL USB Multi-Function Datalogger Model RHT35


Portable Air-conditioner Use and Care Manual

Room thermostat with Auto Timer, independent DHW

Contact Details. Please note that some of the contact details on this PDF document may not be current.

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

Clock Radio AJ100. User manual

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY INFRARED HEATED SEAT MASSAGER MODEL C90005

La Crosse Technology WT-8002U. Digital Clock with Indoor Temperature

Humidity Meters. hygrometers & therma-hygrometers. what is a hygrometer? applications. monitor humidity levels for better health. Humidity.

Room thermostat with Auto Timer, Option External Input

Airbrush Compressor & Vacuum Pump AS20W ARTICEL 34202

Steam Generator v2.0. Model: SI9021N. Helpline. SI9021N_IM.indd 1 28/10/ :45

Model: RT310RF. Installation Manual

PERFORMANCE SLIMMING BELT

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

INSTALLATION INSTRUCTIONS

SHIATSU MASSAGE CUSHION

Humidity Meters HUMIDITY METERS. hygrometers & therma-hygrometers. what is a hygrometer? applications. monitor humidity levels for better health

Dual Laser InfraRed (IR) Thermometer

PROGRAMMABLE 7-DAY RF THERMOSTAT

Professional Wireless Rain Guage with 4" LCD

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

Wet Bulb Thermo-Hygrometer Datalogger

WS-8300U 915 MHz Wireless Weather Station Instruction Manual

Transcription:

Moisture Analyser User Manual PCE-PMI 1 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park Ensign way Hampshire / Southampton United Kingdom, SO31 4RF From outside UK: +44 Tel: (0) 2380 98703 0 Fax: (0) 2380 98703 9 info@pce-instruments.com www.pce-instruments.com/english www.pce-instruments.com

The NON-Contact Moisture Meter is an electronic dampness indicator with a measuring process working on the principle of high frequency measurement. The instrument is used for non-destructively tracing dampness in building materials of all kinds as well as for detecting damp distribution in walls, ceilings and floors. It is particularly suitable for pre-testing the readiness of building materials for covering prior to CM measurement. Features - Quickly indicate the moisture content of materials - Depth of penetration about 20-40mm. - Low battery indication - Auto Power Off - MAX/MIN Function - Measure and HOLD Function - White Backlit LCD Display Specification Specifications: Sensor Type: metal spheroid Measuring Range: 0 to 100 Max Resolution: 1 Battery: 9V battery Dimensions: 180 mm 45mm 35mm Weight: 180g 11

Adjustment The instrument is calibrated fully electronically and readjustment is not necessary. Safety remarks These is a risk of injury if the metal ball comes into contact with live parts. Do not use the instrument in the immediate vicinity of older equipment or equipment equally sensitive to high frequencies (e.g.functioning medicinal equipment).use the instrument only for measuring the dampness in hardened building materials by bringing the ball into contact with the surface. Instrument Check Hold the instrument as near to the back as possible. Press the MESA button and hold the instrument with the ball in the air. The displayed value must be between -5 and +5. Front Panel Description 1 1. Metal Ball 2. MAX/MIN Button 3. LCD Display 4. Power ON/OFF Button 5. Backlight Button 6. MEAS Button 7. Battery Cover 2 3 4 5 6 7 12

Button Function Power Button Turn the meter power ON or OFF. MEAS Button Press the MEAS button, the instrument will start measuring. Release this button the HOLD icon will appear on the LCD indicating that the current reading is being held. MAX/MIN Button When taking measurements, press MAX/MIN Button, the MAX icon will appear on LCD display and the meter will begin keeping track of MAX value. Press the button again, MIN icon will appear on LCD display and the meter will begin keeping track of MIN value. Press MAX/MIN button for two seconds to exit this mode. Backlight button Turn the backlight on or off. Operation After switching on and pressing MEAS the instrument does a self-calibration. There fore hold the instrument during the first measurement into the air away from yourself and other surfaces. The display indicates CAL. After appr. 2 seconds it will display 000 (Keep Meas pressed until CAL disappears. Now you can start with the measurements. Hold the instrument as near to the back as possible. Press the MEAS button and use the ball to scan the surface under investigation. The ball must be in firm contact with the material. To obtain the best results, the instrument should be held at an angle of 90 to the surface to be measured. 13

Note: Do not take measurements on metallic linings! In corners or recessed areas a distance of ca. 8-10 cm form the edge/recess must be maintained. If there is any metal in substructure (constructional steel,channels, pipes,plaster rails,etc.) and with normal coverings, the display jumps to ca. 50 digits for otherwise dry surroundings. It is only possible to reach a conclusion about the absolute dampness in wt-% or the dampness in CM-% if the normal drying out process has taken place (e.g not during or shortly after the use of drying agents or heat guns). If there is not a roughly normal variation in dampness between the surface and the interior, too low a measured value may be indicated. The raw density of the material being measured has a noticeable affect. Basically, the value displayed with dry and damp building materials increases correspondingly with increasing raw density. The values given in the table below are indicative and non-binding.please bear in mind, when evaluating the measured value displayed on the NON-Contact Moisture Meter with respect to the material, that it is not a dampness measurement qualified to VOB or the relevant specialsit regulations. All information and tables in these operating instructions concerning permissible or common dampness conditions in practice as well as the general definition of terms are taken from the technical literature. The manufacturer of the instrument can thus not give any guarantee for the correctness of this information. The conclusions to be drawn from the result of measurements by each user depend upon the individual circumstances and his experience gained from professional practice. 14

Building Moisture range Moisture status Materials (unit) < 30 DRY Gypsum 30-60 MEDIUM > 60 WET < 25 DRY Cement 25-50 MEDIUM > 50 WET < 50 DRY Wood 50-80 MEDIUM > 80 WET Converting table LCD Gypsum (mineral) Screed/Cement Wood %water %water %water 15 20 10,00 25 12,00 30 0,25 15,00 35 0,30 2,50 17,00 40 0,40 2,65 20,00 45 0,65 2,85 50 1,00 3,20 55 1,40 3,55 60 1,70 4,00 65 1,90 4,30 70 2,05 4,70 75 2,20 5,10 80 2,35 5,45 85 2,50 5,75 90 2,65 6,10 This information is a roughly indication. For wood the results are determinated by pine tree. 15

Battery replacement If the icon appears on the LCD display, it indicates that the battery should be replaced. Open the battery case and replace the exhausted battery with new battery. Waste disposal This product has been manufactured using highgrade materials and components which can be recycled and reused. Never dispose of empty batteries and rechargeable batteries in household waste. As a consumer, you are legally required to take them to your retail store or to an appropriate collection site depending on national or local regulations in order to protect the environment. The symbols for the heavy metals contained are: Cd=cadmium, Hg=mercury, Pb=lead This instrument is labelled in accordance with the EU Waste Electrical and Electronic Equipment Directive (WEEE). Please do not dispose of this instrument in household waste. The user is obligated to take end-of-life devices to a designated collection point for the disposal of electrical and electronic equipment, in order to ensure environmentallycompatible disposal This sign certifies that the product meets the requirements of the EEC directive and has been tested according to the specified test methods. Technical changes, any errors and misprints reserved. 16