DT8016AF4 / DT8016AF5 DUAL TEC Motion Sensor with Anti-Mask Installation Instructions

Similar documents
DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

Extended Range DUAL TEC Motion Sensor

DT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

Description. Optex Incorporated

Wireless Keypads LKP(E)S8M Series

STANDARD FEATURES SPECIFICATIONS

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

LUX Hardwired - Installation Notes

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

Wireless Keypad GKP-S8M

English. Italiano. Português. Françias. Español

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

Advanced DIGITAL Wired PIR Motion Detector

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

Intrusion Outdoor Protection Perimeter

General Description. Industrial LuNAR DT AM Grade 3 Features

Model 17A00 Expansion Enclosure

RILEVATORI DI MOVIMENTO DA INTERNO serie unum

Reflective Optical Beam Smoke Detector User Guide

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

DS860 Surface or Corner Mount TriTech PIR/Microwave Detector

Installation, Operating and Maintenance Manual

Quick Selection Guide Intrusion Detectors

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

Installation Instructions

Commercial Series TriTech Motion Detector. Reference Guide

HX-80NRAM. High Mount Outdoor Detector

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Motion Detectors for Larger Rooms and Areas

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

FEC400 Series. Installation Manual

DD205RF/TX Detector Installation Sheet

Commercial Series TriTech+ Motion Detectors with Anti-mask

Commercial Series TriTech+ Motion Detector with Anti-mask

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

Immunity. P/N: ver.b

D-Tect 2 GJD300 Quad PIR Movement Detector

Motorised Infrared Optical Beam Smoke Detector. User Guide

Wireless ShatterPro Acoustic Sensor Installation Instructions

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

DI601AM Outdoor PIR/AM Detector Installation Sheet

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Instructions Dual Spectrum Infrared Flame Detector PM-5MPX. 4.1 Rev: 8/

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Motorised Infrared Optical Beam Smoke Detector. User Guide

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Movement Detector GJD 300

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Honeywell ENERGY SAVINGS KIT

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

D-TECT Dual Tech. GJD360 Triple Technology External Detector

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

S P A C E D E T E C T I O N

Passive Infrared Motion Detector 5420/90P. Installation Instructions

NetworX NX-548E Receiver Installation Instructions

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

4 & 8-POINT ANNUNCIATORS Instruction Manual

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

TECHNICAL DATA OBSOLETE

DS160/161 Request To Exit PIR sensors Installation Instructions

Internal motion detectors by Siemens Range and application overview Building Technologies

Polycarbonate External Sounder & Strobe Unit

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

Model 3300 Technical Support and Installation Manual

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

MODEL: A battery powered, dual technology glassbreak detector designed to work with virtually any transmitter.

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

HR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor

Hardwired Alarm Accessories

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Professional Series TriTech+ Motion Detectors with Anti mask

D8125MUX. Operation and Installation Guide. Multiplex Bus Interface

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

Total Connect Box. User manual

FireNET Plus Wiring Instructions

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

IP65 High Bay Dual Sense Sensor

English. Series. Installation and Use Manual

Multiplex Eight Input Remote Modules

Transcription:

DT8016AF4 / DT8016AF5 DUAL TEC Motion Sensor with Anti-Mask Installation Instructions QUICK LINKS Mounting Location Guidelines Open the Sensor Mount the Sensor Sensor Components and Settings Wire the Sensor Wiring Examples Walk Test the Sensor Detection Patterns Remote LED Enable Relay Operation Mask Condition Troubleshooting Sensor Specifications Accessories Approval Listings Mounting location guidelines: The maximum range is obtained at a mounting height of 2.3m (7 6 ). Allow a clear line-of-sight to all areas to protect. Avoid mounting anything within 30cm (12 ) in front of the sensor. Do not directly face windows. Avoid close proximity to moving machinery, fluorescent lights, and heating/cooling sources. Not for use in applications with pets. [EN] = approved installation. 1. Turn the arrow to point to the Unlock symbol. 2. Press firmly on housing latch. 3. Gently separate the front and rear housing.

[A] = Wall mounting holes. [B] = Corner mounting holes. The rear tamper plate MUST be mounted to a stud, solid wood, or with a robust wall anchor. See wiring details and examples on page 3. - 2 -

WIRING DETAILS - Observe proper polarity. - If not using the integrated EOL resistors, set all switches to. - If using the integrated EOL resistors: 1. Connect the sensor to the panel (see wiring diagrams below). 2. Set the appropriate tamper, alarm and Anti-mask/ [RF] DIP switches to (see Step 4 on page 2). Notes: - Consult the Control Panel manual to determine proper EOL selection. - The Alarm, Tamper and Trouble/anti-mask EOL settings must each only have one switch. - The EOL values should be set at the same time. Wiring Examples Alarm, Tamper and Trouble/Anti-Mask configured to one loop. Alarm, Tamper and Trouble/Anti-Mask configured to two loops. RA = Alarm EOL resistor RT = Tamper EOL resistor RF = Anti-Mask EOL resistor W1 = 1 and 2 loop connection resistor. LED Power Up Walk Test [10 min.] Normal Trouble Fault Anti-Mask Red Slow Blink Alarm Alarm Fast Blink Yellow Microwave Fast Blink Green PIR 1. Close the sensor and apply power to the sensor. Initialization is complete when the LED stops flashing slowly (about 30 seconds). 2. Walk through the detection area and observe the LED. 3. Adjust the microwave range as necessary to meet installation requirements. Walk test mode is active for 10 minutes, then automatically exits test mode, disables the LED and enters normal operation mode. For an additional 10 minute walk test, enable walk test mode again with the flashlight feature (see the following page). Notes: - During power up and walk test modes the LED is active regardless of the LED Enable/Disable DIP switch setting. - When the microwave sensitivity is set to minimum, the sensor range is reduced to 5m. - 3 -

Flashlight Feature: 1. Use a flashlight with a bright light beam, and stand within 1.2 m (4 ) of the sensor. 2. Swing the light beam past the sensor IR window 3-5 times, holding the beam on the window for 0.5 second each pass. The flashlight feature is only available for the first 24 hours after the first power up. Zones A 2 Look-down B 12 Lower C 10 Intermediate D 36 Long REMOTE LED ENABLE (LED INPUT) The LED input terminal allows the LED to be remotely enabled. To use this feature, the LED DIP switch (switch 2) must be, allowing the LED to operate based on the voltage level connected to the LED Input (see Wiring Details). Switch 2 LED Input LED Operation High ( +12 V) Enabled Low (0 V) Disabled Low (0 V) or High (+12 V) Enabled RELAY OPERATI SENSOR STATUS Normal Intrusion Trouble 1 Mask 2 Alarm Relay Closed Open Closed Open Trouble Relay 3 Closed Closed Open Open 1 For information on Trouble conditions, see the Troubleshooting section. 2 In a Mask condition, the Alarm and Trouble relays will activate simultaneously, and remain open until the condition has been cleared. 3 In a Trouble condition, the Trouble relay will latch open until the Trouble condition has been cleared. MASK CDITI Normal Anti-Mask Condition The sensor uses Active Infrared (AIR) technology to detect masking. The sensor signals a mask condition when a variety of materials and reflective objects are placed within 50mm (2 inches) in front of the sensor. To avoid false mask alarms, follow the mounting guidelines shown in Step 1. Clearing an Anti-Mask Condition When most masking materials or objects are removed, the anti-mask condition will be cleared after several seconds. When the cause of the anti-mask condition is any type of spray or paint coating applied to the window, the window must be replaced before the anti-mask condition can be cleared. After replacing the window, perform a walk-test on the sensor. TROUBLESHOOTING TROUBLE* NORMAL Mask 1 Low Self-Test Voltage 2 Failure 3 Alarm Relay Closed Open Closed Closed Trouble Relay Closed Open Open Open Red LED Off Off Off Flashing Yellow LED Off Flashing Off Off *TROUBLE CDITIS: 1 Mask condition: Sensor IR window is blocked or masked. 2 Low Voltage: The sensor is disabled. [Note: If voltage drops below 5V, both Alarm and Trouble relays open.] 3 Self-Test Failure conditions: Microwave supervision failure: The sensor is operating in PIR mode only. PIR self-test failure: The sensor is disabled. Temperature compensation failure: The temperature compensation is disabled. Depending on the Trouble condition, take the following corrective actions: Verify the sensor is not blocked or masked. Verify the power supply is sufficient (at least 9V at the sensor). Cycle power to the sensor. Walk test the sensor. If the Trouble condition does not clear, replace the sensor. - 4 -

SPECIFICATIS Range: 16 m x 22 m Power: 9.0-15 VDC; 11 ma typical, 14 ma maximum, 12 VDC; AC Ripple: 3 V peak-to-peak at nominal 12 VDC Alarm Relay: Energized Form A; 30 ma, 25 VDC, 22 Ohms resistance maximum. Alarm Relay Duration: 3 seconds Trouble Relay: Energized Form B; (NC) 30 ma, 25 VDC; 22 Ohms resistance maximum Tampers: Cover & Wall; (NC with cover installed) Form A; 30 ma, 25 VDC; Magnetic field Microwave Frequencies: DT8016AF4-10.525 GHz DT8016AF5-10.587 GHz RFI Immunity: 15 V/m, 80 MHz 2.7 GHz PIR White Light Immunity: 10,000 Lux typical Fluorescent light filter: 50 Hz / 60 Hz. Operating Temperature: -10 to 55 C Relative Humidity: 5 to 95%; non-condensing Temperature Compensation: Advanced Dual Slope Dimensions: 11.6 cm H x 7.0 cm W x 4.3 cm D Weight: 135 g / 5 oz (net weight) ACCESSORIES SMB-10 (P/N 0-000-110-01) SMB-10C (P/N 0-000-111-01) SMB-10T (P/N 0-000-155-01) Swivel Mount Bracket Swivel Mount Ceiling Bracket Swivel Mount Bracket w/tamper APPROVAL LISTINGS EN50131-2-4:2008, Security Grade 3, Environmental Class II. Suitable for connection to an EN 60950 Class II Limited Power Source. Note: In EN 50131-2-4 compliant installations, mount the sensor at 2.3m, do not use only the right side corner mounting holes, enable look down, set the microwave sensitivity to maximum and lock the sensor housing with the cover lock (see [EN] where noted in Steps 1-4). Important: The sensor should be tested at least once each year. LARMKLASS 4 NF&A2P 3 boucliers (référentiel NF324-H58) et conforme aux normes EN50131-2-4 et RTC50131-2-4; IP30 IK04 DT8016AF4 N de certificat: 2831420015 DT8016AF5 N de certificat: 2821420015 Organisme de certification: CNPP Cert. : www.cnpp.com et AFNOR Cert.: www.marque-nf.com Honeywell Security Group - BP1219 1198 avenue du docteur Maurice Donat Sophia Antipolis 06254 Mougins Cedex. TEL: +33.4.92.94.29.50 FAX: +33.4.92.94.29.60 Corrente norminale: 12 = Corrente massima assorbita: 14 ma DT8016AF4 INCERT B-893-0012 DT8016AF5 PD6662:2010 Note: The accessories are not covered by certifications. - 5 -

For any additional information, please refer to our Website: http://www.honeywell.com/security/emea/hscdownload Or contact: Honeywell Security Group Newhouse Industrial Estate Motherwell Lanarkshire ML1 5SB United Kingdom Tel: +44(0)1698 738200 Email: UK64Sales@Honeywell.com Please contact your local authorised Honeywell representative for product warranty information. 2013 Honeywell International Inc. Honeywell and DUAL TEC are registered trademarks of Honeywell International Inc. All other trademarks are the properties of their respective owners. All rights reserved. Made in China. www.honeywell.com/security P/N 800-15667 Rev B