PRICE SHEET: NXPS-3 EFFECTIVE: July 1, 2018 SUPERSEDES: NXPS-2 HIGH EFFICIENCY GAS-FIRED, UNIT HEATER LIST PRICES ITEM PAGE HU Series Unit Number Description...2 HU Series...3 Options...4 Options - Accessories, Conversion Kits...5 Terms of Sale...6 Warranty...7 260 North Elm Street, Westfield, MA 01085 TEL: (413) 564-5540 * FAX: (413) 562-5311 www.sterlinghvac.com
NEXUS - HU SERIES HIGH EFFICIENCY GAS-FIRED UNIT HEATER UNIT NUMBER DESCRIPTION Digit N X X X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 + Item Prefix UT CA FT FM GT AL GC SV MT MS DL AS (Internal Use Only) 1,2 - Unit Type [UT] HU - High Efficiency Unit Heater 3,4,5 - Capacity [CA] 050-50,000 BTU/HR 100-100,000 BTU/HR 150-150,000 BTU/HR 200-200,000 BTU/HR 300-300,000 BTU/HR 400-400,000 BTU/HR 6 - Furnace Type [FT] A - Right Side Access 7 - Heat Exchanger (Furnace) Material [FM] 1 - Stainless Steel Tubes with Aluminum and Brass Fins Note: Stainless Steel Flue Collector is standard. 8 - Gas Type [GT] N - Natural Gas P - Propane Gas (LP) 9 - Altitude [AL] S - 0-11,999 ft. Note: Installations over 2,000 ft. require gas input deration in the field. Refer to unit installation instructions. 10 - Direct Spark Gas Control [GC] 1 - Modulating w/outside Air Reset (Master) 2 - Modulating w/outside Air Reset (Network) 3 - Modulating w/indoor Air Reset 4 - Modulating w/2-10 VDC/4-20 ma Input 5 - Modulating w/room Sensing 6 - Two Stage 11 - Supply Voltage [SV] 1-115/1/60 5-230/3/60 2-208/1/60 6-460/3/60 3-230/1/60 7-575/3/60 4-208/3/60 Z - Special Note: Supply Voltage [SV] 2-7 include field mounted step down transformer. 12 - Motor Type [MT] 1 - Open Drip Proof (Standard) 13 - Blower Motor Sizes [MS] 0 - Not applicable 14 - Design Level [DL] A - First design level 15+ - Accessories [AS] FIELD INSTALLED (AS- ) All Field Installed Accessories are to be entered as a separate line item using the catalog number which utilizes AS as a prefix. i.e: G3 becomes AS-G3 A7 - High Pressure Regulator A7-1/2-1 - Regulator for PSI range 0.5-10 A7-3/8-1 - Regulator for PSI range 10-20 A7-5/16-1 - Regulator for PSI range 20-35 E9 - Condensate Neutralizer (Inline) EW - Condensate Neutralizer (Wall Mounted) G1-1-Stage T87K Mercury Free Thermostat w/subbase Kit G2-1-Stage T87K Mercury Free Thermostat w/tg511a Guard Kit G3-1-Stage T834N Mercury Free Thermostat/Fan Switch G5-2-Stage TH5220D Mercury Free Thermostat w/subbase G6 - Locking Thermostat Cover G9-1-Stage T822K Mercury Free Thermostat H9 - Stratification Sensor K8 - Condensate Pump K9 - Condensate Pump Shelf Y2-2" PVC Concentric Vent Kit Y3-3" PVC Concentric Vent Kit Y4-4" PVC Concentric Vent Kit 2
NEXUS HIGH EFFICIENCY UNIT HEATER Unit Type [UT]: HU Capacity [CA]: 100-400 Furnace Type [FT]: A Heat Exchanger Construction Material [FM]: 1 409 Stainless Steel Tubes with Brass and Aluminum Fins 321 Stainless Steel Flue Collector 95+% Thermal Efficiency 115/1/60 Supply Voltage Combustion Blower & Power Ventor Blocked Inlet Air Pressure Switch Blocked Vent Air Pressure Switch Natural or Propane (LP) Gas 20-Gauge 430 Brushed Stainless Steel Cabinetry STANDARD EQUIPMENT Direct Spark Ignition System High Limit Switch External LED Diagnostic Lights 115/24 Volt Control Transformer Easy Access Isolated Control Panel Modbus Open Drip Proof Motor Rear Control Access 10 Year Heat Exchanger, Burner and Flue Collector Warranty Negative Pressure Gas Valve Right Side Burner Access OSHA Fan Guard 4 Point Suspension Field Convertible to Separated Combustion Condensate Trap Condensate Float Switch Gas Conversion Kit Included Residentially Certified for Use as a Utility Heater [CA] Capacity List Price Approx. Ship Weight 050 $3,900 168 lbs. 100 $4,988 228 lbs. 150 $5,410 254 lbs. 200 $6,200 305 lbs. 300 $8,348 388 lbs. 400 $10,369 460 lbs. Supply Voltages: 208 and 230/1/60 and 208, 230, 460, 575/3/60 2-Stage and Various Electronic Modulating Gas Controls OPTIONAL EQUIPMENT Single and 2-Stage Mercury Free Thermostats Locking Thermostat Cover Pressure Regulator (1/2-35 PSI) Condensate Neutralizer Condensate Pump Condensate Pump Shelf Kit Concentric Vent Kit Stratification Sensor 3
OPTIONS Furnace Type [FT]: Digit 6 Heat Exchanger Construction Material [FM]: Digit 7 A [FT] Furnace Type Standard Right Side Access List Note: Control Access location determined by facing unit in the direction of airflow. [FM] Heat Exchanger Material 1 Stainless Steel w/brass & Aluminum Fins Note: Stainless Steel Flue Collector is standard. List Gas Type [GT]: Digit 8 Altitude [AL]: Digit 9 N P [GT] Gas Type Natural Gas Propane (LP) Gas List S [AL] Altitude 0-11,999 ft. List Note: Installations over 2,000 feet require gas input deration in the field. Refer to unit installation instructions. Gas Control [GC]: Digit 10 [GC] Gas Control *Only one master unit is required when networking multiple units together. Supply Voltage [SV]: Digit 11 [SV] Supply Voltage [CA] Capacity 050 100 150 200 300 400 1 Modulating w/outside Air Reset (Master)* $90 2 Modulating w/outside Air Reset (Network) 3 Modulating w/indoor Air Reset 4 Modulating w/2-10 VDC/4-20 ma Input 5 Modulating w/room Sensing $45 6 2-Stage [CA] Capacity 050 100 150 200 300 400 1 115/1/60 2 208/1/60 $930 $790 $1446 3 230/1/60 $357 $708 $1137 4 208/3/60 $930 $790 $1446 5 230/3/60 $357 $708 $1137 6 460/3/60 $357 $708 $1137 7 575/3/60 $520 $767 $1478 Notes: 1. Supply Voltages [SV] 2-7 include step down transformer, shipped loose for field installation. 2. IMPORTANT: Field installed step-down transformers provided for Supply Voltages [SV] 2-7 cannot be mounted onto the unit due to the weight of the transformer. The step-down transformer should be mounted elsewhere and wired to the unit accordingly. 4
OPTIONS Accessories [AS]: Digit 15+ [CA] Capacity 050 100 150 200 300 400 Field Installed (AS - ) A7-1/2-1 Range 0.5-10 PSI $210 A7 High Pressure Regulator A7-3/8-1 Range 10-20 PSI $210 A7-5/16-1 Range 20-35 PSI $210 E9-1 Condensate Neutralizer (Inline) (050-200 MBH) $226 N/A E9-2 Condensate Neutralizer (Inline) (300-400 MBH) N/A $254 EW-1 Condensate Neutralizer (Wall Mounted) (050-200 MBH) $194 N/A EW-2 Condensate Neutralizer (Wall Mounted) (300-400 MBH) N/A $248 G1 1-Stage T87K w/subbase Kit $165 G2 1-Stage T87K w/tg511a Guard Kit $221 G3 1-Stage T834N Thermostat/Fan Switch $90 G5 2-Stage TH5220D Thermostat w/subbase $270 G6 Locking Thermostat Cover $92 G9 1-Stage T822K Thermostat $111 H9 Stratification Sensor $42 K8 Condensate Pump $166 K9 Condensate Pump Shelf $79 Y2 2" PVC Concentric Vent Kit $153 N/A Y3 3" PVC Concentric Vent Kit N/A $180 N/A Y4 4" PVC Concentric Vent Kit N/A $305 [CA] Capacity 050 100 150 200 300 400 Gas Conversion Kits (Field Installed) HU 50/400 Direct Spark Ignition Only* Part Number Unit Capacity List Price From Natural Gas (NG) to Propane (LP) 11CVKTNTP-HU050 050 $55 11CVKTNTP-HU1-2 100-200 $55 11CVKTNTP-HU300 300 $55 11CVKTNTP-HU400 400 $55 Part Number Unit Capacity List Price From Propane (LP) to Natural Gas (NG) 11CVKTPTN-HU050 050 $55 11CVKTPTN-HU1-2 100-200 $55 11CVKTPTN-HU300 300 $55 11CVKTPTN-HU400 400 $55 Order conversion kits as separate line item(s). *Gas conversion kit is included in the box with every HU unit. 5
TERMS OF SALE FREIGHT TERMS UNIT HEATERS F.O.B. factory. Full Freight Allowed as follows: shipments over 1,200 lbs. into ZONE I; shipments over 1,400 lbs. into ZONE II; shipments over 1,600 lbs. into ZONE III. ZONES ZONE I: USA: Alabama, Connecticut, Delaware, District of Columbia, Florida, Georgia, Indiana, Kentucky, Maine, Maryland, Massachusetts, Michigan, Mississippi, New Hampshire, New Jersey, New York, North Carolina, Ohio, Pennsylvania, Rhode Island, South Carolina, Tennessee, Vermont, Virginia, West Virginia. CANADA: Ontario, Maritimes, Québec. ZONE II: USA: Arkansas, Colorado, Illinois, Iowa, Kansas, Louisiana, Minnesota, Missouri, Montana, Nebraska, New Mexico, North Dakota, Oklahoma, South Dakota, Texas, Wisconsin, Wyoming. CANADA: Manitoba, Saskatchewan. ZONE III: USA: Arizona, California, Idaho, Nevada, Oregon, Utah, Washington. CANADA: Alberta, British Columbia. Alaska & Hawaii: Consult with Customer Service. NO FREIGHT ALLOWANCE ON SHIPMENTS OF LESS THAN 1,200 lbs. FREIGHT ROUTING SHALL BE AT THE DISCRETION OF THE SHIPPER. No obligation is assumed by this Corporation to sell, to anyone holding this book, any of the items listed herein at the prices stated. VALID ORDERS: An order is not valid until acknowledged by the Factory in Farmville, N.C. TERMS: 1% 15 Prox. Prepaid freight or cartage charges paid by us are not subject to cash discount. TAXES: The prices listed herein exclude Federal, State, or Municipal Tax applicable to the transaction. Such taxes, where applicable to the transaction should be paid directly to the governing authority by the Purchaser. CLAIMS: As all goods are shipped at buyer s risk they should be examined carefully before signing transportation delivery receipts. If transportation company tenders delivery of goods in bad order, buyer should insist on transportation agent making notation of conditions on delivery receipt and request an inspection within 48 hours, thus enabling buyer to secure prompt payment of transportation claims filed by him for value of damaged material. The responsibility of this Company ceases upon delivery of goods in order to transportation companies. All orders are accepted subject to delays on account of government requirements, strikes, accidents or other causes beyond our control. MINIMUM ORDERS: Orders with an invoice of less than $25.00 will be invoiced at $25.00. RETURNED GOODS: Goods must not be returned except by written permission from the factory, and when so returned will be accepted only as stated in the following conditions: 1. Special material is not subject to return. 2. All transportation charges for returned goods must be prepaid by the shipper. 3. Standard catalogued products may be returned upon written permission. After inspection at the factory, if they are found to be in good condition they will be accepted for credit, subject to a 25% handing charge. 4. No goods will be accepted for return more than 6 months after shipment. CHANGES TO A RELEASED ORDER: Work commences on release of an order, therefore, an order that is changed will be subject to additional charges for any extra time and material expended. CANCELLATIONS: A minimum of 25% and maximum of all time and material will be charged, depending on work completed. In the interest of product improvement, we reserve the right to make changes without notice. 6
WARRANTY NEXUS - HU SERIES LIMITED WARRANTY 1. STERLING HVAC HIGH EFFICIENCY UNIT HEATER - MODEL HU Sterling ( the Manufacturer ) warrants to the original owner at original installation site that the above units of Sterling HVAC Heaters ( the Product ) will be free from defects in material or workmanship for one (1) year from the date of shipment from the factory, or one and one half (1-1/2) years from the date of manufacture, whichever occurs first. Sterling further warrants that the complete heat exchanger, flue collector, and burners will be free from defects in material or workmanship for a period of ten (10) years from the date of manufacture. If upon examination by the Manufacturer the Product is shown to have a defect in material or workmanship during the warranty period, the Manufacturer will repair or replace, at its option, that part of the Product which is shown to be defective. 2. This limited warranty does not apply: (a) if the Product has been subjected to misuse or neglect, has been accidentally or intentionally damaged, has not been installed, maintained or operated in accordance with the furnished written instructions, or has been altered or modified in any way by any unauthorized person. (b) to any expenses, including labor or material, incurred during removal or reinstallation of the Product. (c) to any damage due to corrosion by chemicals, including halogenated hydrocarbons, precipitated in the air. (d) to any workmanship of the installer of the Product. 3. This limited warranty is conditional upon: (a) advising the installing contractor, who will in turn notify the distributor or manufacturer. (b) shipment to the Manufacturer of that part of the Product thought to be defective. Goods can only be returned with prior written approval of the Manufacturer. All returns must be freight prepaid. (c) determination in the reasonable opinion of the Manufacturer that there exists a defect in material or workmanship. 4. Repair or replacement of any part under this Limited Warranty shall not extend the duration of the warranty with respect to such repaired or replaced part beyond the stated warranty period. 5. THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EITHER EXPRESS OR IMPLIED, AND ALL SUCH OTHER WARRANTIES, INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS LIMITED WARRANTY. IN NO EVENT SHALL THE MANUFACTURER BE LIABLE IN ANY WAY FOR ANY CONSEQUENTIAL, SPECIAL, OR INCIDENTAL DAMAGES OF ANY NATURE WHATSOEVER, OR FOR ANY AMOUNTS IN EXCESS OF THE SELLING PRICE OF THE PRODUCT OR ANY PARTS THEREOF FOUND TO BE DEFECTIVE. THIS LIMITED WARRANTY GIVES THE ORIGINAL OWNER OF THE PRODUCT SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS WHICH MAY VARY BY EACH JURISDICTION. 7
260 North Elm Street, Westfield, MA 01085 TEL: (413) 564-5540 * FAX: (413) 562-5311 www.sterlinghvac.com