The six tests conducted included three smoldering and three fast flaming type tests.

Similar documents
Ionization Smoke Alarms A Substantial Product Hazard

Frequently Asked Smoke Alarm Questions

A Comparison of Carbon Monoxide Gas Sensing to Particle Smoke Detection in Residential Fire Scenarios

SMOKE/CARBON MONOXIDE DETECTOR REQUIREMENTS

MFES READY Make your home fire safe. Home Smoke Alarms

WELCOME TO ROSEVILLE UNIVERSITY

Smoke & Carbon Monoxide

TIMOTHY R. SZYMANSKI Instructor

Smoke & Carbon Monoxide Alarms

Fire Safety HDT Rally Jack Mayer, jackdanmayer.com

Fire Safety and Whole Home Protection

First Alert Smoke Alarm Beeping Every 30 Seconds

Smoke Alarms and Carbon Monoxide Alarms

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

SMOKE & CARBON MONOXIDE ALARMS

FIRE PREVENTION AND SAFETY IN THE HOME. Provided to You by Lawrence Laviolette CD Fire Safety Officer

Furniture LOT 1-6. LOT 1: Textiles, curtains and bedding. Fitted Bed Sheet, Cotton, various colors, No. Item Picture Samples. Double Bed.

NationalFireEquipmentLtd.

FIRE PREVENTION AND SAFETY IN THE HOME CW2 BILL GUNNETT

WHEREAS, a photoelectric smoke alarm, in a smoldering fire, can alert a warning signal faster than a non-photoelectric smoke alarm; and

CANADIAN FIRE ALARM ASSOCIATION An Update on Standards, Technologies and Solutions. Smoke Characterization Study

HOME FIRE SAFETY. Reference Guide

Smoke Alarms Save Lives.

Family Foster Home Fire Safety Evaluation Checklist Instructions

RV Safety Alarms Education Test

Learn About Fires Every day, Americans experience the horror of fire but most people don't understand it.

Smoke Alarm and Carbon Monoxide Alarm Installation

DAMAGE CODES* CODE DAMAGE COST

Smoke Alarms. Rev. A Copyright 2011 James D Peisker

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

Residential Fire Protection

Consumer Product Safety Commission Smoke Alarms Why, Where, and Which CPSC Document #559

Results from a Full-Scale Smoke Alarm Sensitivity Study

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

Smoke Alarm User s Guide

Carbon Monoxide Alarms Smoke and Carbon Alarms Upgrade Requirements for Single and Two Family Dwellings

FAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space?

In just two minutes, a fire can become life-threatening. In five minutes, a residence can be engulfed in flames.

Smoke Alarm User s Manual

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

Performance of Smoke Detectors and Sprinklers in Residential and Health-Care Occupancies

Impact on Smoke Alarm Performance Considering New Nuisance and Fire Tests

SAFETY TIPS. From Your Building Inspector. The Sound of Safety.

SAFEGUARD YOUR HOME WITH QUELL

Smoke Alarm User s Guide

FULL-SCALE FIRE TESTS OF A TWO-STORY CROSS-LAMINATED TIMBER STRUCTURE

Requirements for Smoke Detector / Carbon Monoxide/ Fire Extinguisher Certification

UL Conference Atlanta May 21 22, 2014 Polyurethane Foam Association presentation

Smoke Alarm User s Guide. AC Wire-in Single and/or Multiple Station (up to 24 Devices) Photoelectric Smoke Alarm with 9 Volt Battery Back Up.

Invensys Controls Americas

7.1 Smoke Detector Performance

General Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division

Construction Innovation Center Building 186

Incident Summary (Reference # )

THE TOWNSHIP OF CRANBURY

Potential Impact of New UL Fire Test Criteria

From Your Building Inspector

Fire Extinguisher Training

120V AC Smoke Alarm with 9V Battery Back-up

FLW FD. Fire Safety Activity SPOT. Hi, I m your friend, Spot Fire Safety Dog (Spraky's Best Friend).

Smoke Alarm Research at NIST

What are the four things that must be present at the same time to produce fire?

Housing Fact Sheets. Home Fire Protection

Smoke Alarms (Fire Safety) By Michael Dahl

Risk Management Department. Fire Extinguishers

NYU RESIDENTIAL FIRE SAFETY PLAN PART I - BUILDING INFORMATION SECTION

Characterising the smoke produced from modern materials and evaluating smoke detectors

Interior & Exterior Finishes & Specifications for The Bradford & Weston Style Homes

Scope of Work Single Family, Canal Winchester, OH

Safe at Home. Suggestions for Homeowner Created in partnership with the Administration on Aging. Assessor: Assessor: Homeowner Name: Address:

Topic: Mechanical Ventilation Refresher Reference #: DG Level of Instruction: In service personnel Time Required: 3 hours

BALTIMORE CITY RENTAL LICENSE INSPECTION FORM RENTAL LICENSING INSPECTOR GUIDANCE

To obtain a greater understanding of the factors which contribute towards fire injuries and fatalities

Requirements for Smoke / Carbon Monoxide / Fire Extinguisher Certification

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

INVENTORY REPORT REPORT SUMMARY OPTIONAL ITEMS. 1 P a g e ASSOCIATION: SUNNYSIDE COURTS CONDO ASSOCIATION ADDRESS: 3047 N LINCOLN AVE

Abstract. Introduction

UNIVERSITY OF RICHMOND HOUSING FIRE SAFETY POLICY

Smoke Alarm User Manual

FIRE PROTECTION & PREVENTION

Smoke Alarm. 120V AC Ionization. Smoke Alarm. Back-up. with 9V Battery

FIRE AND SMOKE RESISTANT INTERIOR MATERIALS FOR COMMERCIAL TRANSPORT AIRCRAFT

The Commonwealth of Massachusetts Executive Office of Public Safety and Security Department of Fire Services

FIRE INVESTIGATION SUMMARY REPORT

Home Inspection Report

[EPUB] REPLACE FIRE ALARM BATTERY DOWNLOAD

STATE OF MAINE Department of Public Safety Office of State Fire Marshal 52 State House Station Augusta, ME

Residential Fire Safety: An Overview of the Problem and Interventions.

Safety Manual Section 7 Fire/Life Safety

Structure type: (2 story, ranch, bi-level, split level, I½ story, apt, duplex, town house) Location of house (rural, semi rural, suburban, urban)

APPLIANCE USE AND CARE

Everyday Americans experience the horror of fire but most people do not understand fire.

Fire Extinguisher Training

280 Fairway Oaks Dr Property Improvements Unit #A Improvements Performed in 2018

PLACE GOODWYN BUILDING CO. Montgomery's Hometown Builder BUILDER PAYS $3000 TOWARD CLOSING COSTS AVAILABLE FLOOR PLANS FOR 50' LOTS

Scope of Work - Single Family, Escondido, CA

NewDigs.co.uk Quality Furnished Accommodation

Luckdrops. Technical Spec Sheet. Studio+ Modular Home

Accessibility Statement

Transcription:

The Mayfield Village Tests On May 9, May 12 and May 13, 2014 NEOFPA conducted six full-scale, real-world smoke alarm comparison tests in the city of Mayfield Village, Ohio. Tests 5 and 6 conducted on May 13 were videotaped for a story by ABC s Good Morning America. The home, which was slated for demolition by the city of Mayfield Village, was a one-story wood framed three bedroom, one bath ranch-style single-family home. The interior walls and ceiling finish were of painted drywall. The ceiling height was 8 feet. During the tests, all doors and windows were in the closed position. Also, there was no artificial air movement in the home during the tests. The six tests conducted included three smoldering and three fast flaming type tests. The smoldering fire tests were created by inserting a brand new soldering iron between the cushions of two new couches. Each couch was positioned in the living room in the typical location. The living room was approximately 14' x 20' in size. The heated soldering iron caused the cushions to smolder without igniting for a considerable length of time and create large volumes of smoke, replicating a typical smoldering fire incident in a single-family residence. A firefighter in full turnout gear and self-contained breathing apparatus was stationed approximately 10 from the couch during the tests to observe and report conditions. The flaming fire tests were created by igniting class A combustibles including paper and cardboard in a galvanized tub. The tub was positioned in the center of the kitchen floor. The kitchen was approximately 11' x 12' in size. The resulting fire replicated a typical trash can fire incident in a kitchen. A firefighter in full turnout gear and self-contained breathing apparatus was stationed approximately 10 from the tub during the tests to observe and report conditions. The brand new smoke alarms were mounted to a wooden board which was then mounted to the bedroom hallway ceiling in what would have been the recommended location per national standards. This hallway connected the front living room, foyer, kitchen, bathroom and bedrooms and was approximately 28 long by 3 wide. The smoke alarms were identified by manufacturer and sensor type and were numbered. The distance from the ignition point on the couches to the smoke alarms was approximately 23 feet. The distance from the ignition point in the galvanized tub to the smoke alarms was approximately 11 feet. A firefighter in full turnout gear and self-contained breathing apparatus was stationed directly below the smoke alarms during the tests to observe and report conditions and smoke alarm functioning.

Test 1: May 9, 2014 at 10:43 am-smoldering Test Equipment used: Heat source: Weller 110 volt, 25 watt soldering-iron model SP23LK. Maximum temperature of 750 F. Furniture/Fuel Source: Sofa. (96x44x39 ) New condition. Jackson Furniture Industries. Body: textile waste fiber, resinated polyester fiber batting, polyurethane foam pad. Seat: polyurethane foam pad, resinated polyester fiber batting. Wood frame. Smoke alarms used: 1: Kidde ionization sensor model I9010. Manufacture date: 12-24-13. Sealed lithium-ion battery. 2: Kidde Photoelectric sensor model P3010H. Manufacture date: 8-30-12. Sealed lithium-ion battery. 3: Blank 4: First Alert ionization sensor model SA304. Date of manufacture 2-6-14. 9 volt battery. 5: First Alert photoelectric sensor model P900E. Date of manufacture: Not reported. Battery not reported. 6: First Alert dual sensor (photoelectric and ionization) model SA320. Date of manufacture: Not reported. Battery not reported. Carbon monoxide detector used: Carbon monoxide meter: Fire department owned. The make and model number were not recorded. Test 1 Time Line: (Time in hh:mm:ss indicates hours, minutes and seconds since first smoke.) 10:43 AM: Start test. Heat on. 10:44 AM: 00m:00s: First smoke. 10m:00s: CO level: 1 ppm. Light smoke in living room. No smoke in hall. 12m:35s: Smoke production increasing. 15m:00s: CO level: 4 ppm. Light smoke throughout living room, foyer and entry to hallway. 15m:44s: CO level: 10 ppm. 17m:52s: Smoke migrating down hall. 20m:00s: CO level: 16 ppm. Visible haze down the hall. 21m:30s: Smoke alarm 2 activates. CO level: 17 ppm. 21m:35s: Smoke alarm 5 activates. CO level: 17 ppm. 22m:44s: Smoke alarm 6 activates. CO level: 21 ppm. 26m:00s: Smoke is now visible in the kitchen.

30m:00s: CO level: 30 ppm. Visibility is approximately 25 feet in smoke. No smoke visible on the exterior of the home. 35m:00s: CO level: 36 ppm. 39m:30s: CO level: 50 ppm. 44m:00s: Smoke alarm 4 activates. CO level: 52 ppm. 45m:30s: Smoke alarm 4 stops sounding. 48m:10s: Less than 25 feet visibility in smoke. No smoke visible on the exterior of the home. 49m:30s: CO meter ceases to function. 51m:28s: Smoke alarm 4 activates again. 1h:02m:00s: Visibility is approximately 15 feet at 3 feet above the floor. 1h:13m:44s: Smoke is now solid floor to ceiling. No smoke visible on the exterior of the home. 1h:14m:00s: Test stopped. Smoke alarm 3 did not activate during this test. Test button was pushed and alarm sounds verifying it was operating. Test 1 Summary: The Kidde photoelectric smoke alarm (#2) sounded at 21m:30s. The First Alert photoelectric smoke alarm (#5) sounded at 21m:35s. 5 seconds after the first photoelectric smoke alarm sounded. The First Alert dual sensor smoke alarm (#6) sounded at 22m:44s. One minute and 14 seconds after the first photoelectric smoke alarm sounded. The First Alert ionization smoke alarm (#4) first sounded at 44m:00s. 22 minutes and 30 seconds after the first photoelectric smoke alarm sounded. It sounded for one minute and 30 seconds then stopped sounding. It began sounding continuously again at 51m:28s. The Kidde ionization smoke alarm (#1) never activated during this test.

Test 2: May 9, 2014 at 2:46 pm-smoldering Test Equipment used: Heat source: Weller 110 volt, 25 watt soldering-iron model SP23LK. Maximum temperature of 750 F. Furniture/Fuel Source: Sofa. (96x44x39 ) Same sofa that was used in test 1. New condition. Jackson Furniture Industries. Body: textile waste fiber, resinated polyester fiber batting, polyurethane foam pad. Seat: polyurethane foam pad, resinated polyester fiber batting. Wood frame. Smoke alarms used: 1: Kidde dual sensor (ionization & carbon monoxide) model KN-COSMXTR-BA 2: First Alert photoelectric sensor model: Atom 3: Kidde ionization sensor model I9040 4: Kidde dual sensor (photoelectric & ionization) model PI9010. 5: First Alert dual sensor (photoelectric & ionization) model SA320. 6: First Alert ionization sensor model FG200. 7: First Alert photoelectric sensor (One Link) model SA511. Date of manufacture: 4-12-13. Two AA batteries. Carbon monoxide detector used: Carbon monoxide meter: Fire department owned. The make and model number were not recorded. Test 2 Time Line: (Time in hh:mm:ss indicates hours, minutes and seconds since first smoke.) 2:46 PM: Start test. Heat on. 2:48PM (00m:00s): First Smoke. 05m:00s: Light smoke collecting at living room ceiling. 10m:00s: Smoke halfway down to floor in living room. Some smoke now in foyer. 15m:00s: Smoke now entering hallway, 5 feet off of floor. 20m:00s: CO: 3 ppm. Smoke in hall now at floor level. 21m:10s: CO level: 9 ppm. 21m:18s: Smoke alarm 5 activates. 22m:04s: CO level: 16 ppm. 22m:30s: Smoke alarm 7 activates. Smoke now visible in kitchen. 24m:17s: Smoke alarm 4 activates. 24m:57s: CO level: 24 ppm.

28m:42s: Smoke alarm 2 activates. 29m:47s: CO level: 38 ppm. 30m:30s: Can not see the end of the hallway. 32m:13s: CO level: 45 ppm. 33m:30s: Would need to crawl to see in the hallway and living room areas. No smoke visible on the exterior of the home. 34m:30s: CO level: 54 ppm. 35m:40s: Smoke alarm 1 activates indicating carbon monoxide. 37m:30s: Visibility at the floor level is down to approximately 10 feet. 39m:15s: CO level: 70 ppm. 40m:10s: Smoke alarm 1 activates indicating fire. 40m:41s: CO level: 74 ppm. 46m:00s: CO meter no longer functioning. 54m:00s: Still no smoke visible on the exterior of the home. 1h: 05m:00s: End of test. Smoke alarms 3 and 6 did not sound during the test. Test buttons were pushed and alarms sound verifying they were operating. Test 2 Summary: The First Alert dual sensor alarm (#5) sounded at 21m:18s. The First Alert photoelectric alarm (#7) sounded at 22m:30s. One minute and 12 seconds after the first smoke alarm sounded. The Kidde dual sensor alarm (#4) sounded at 24m:17s. Two minutes and 59 seconds after the first smoke alarm sounded. The First Alert photoelectric alarm (#2) sounded at 28m:42s. Seven minutes and 24 seconds after the first smoke alarm sounded. The Kidde dual sensor alarm (#1) sounded for carbon monoxide at 35m:40s. 14 minutes and 22 seconds after the first smoke alarm sounded. The Kidde dual sensor alarm (#1) sounded for fire at 40m:10s. 18 minutes and 52 seconds after the first smoke alarm sounded. The Kidde ionization alarm (#3) and the First Alert ionization alarm (#6) never activated during this test.

Test 3: May 12, 2014 at 9:20 am-flaming Test Equipment used: Heat source: Standard wooden kitchen match. Furniture/Fuel Source: Class A combustibles including paper and cardboard in a galvanized tub. Smoke alarms used: 1: First Alert photoelectric sensor. 2: First Alert ionization sensor. 3: Kidde ionization sensor. 4: Kidde photoelectric sensor. 5: First Alert dual sensor (photoelectric & ionization). Model SA320. Date of manufacture: 8-9-13. Two AA batteries. 6: Kidde dual sensor (photoelectric & ionization). Model PI9010. Date of manufacture: 11-29-13. 9 V battery. Carbon monoxide detector used: Carbon monoxide meter: Fire department owned. The make and model number were not recorded. Test 3 Time Line: (Time in hh:mm:ss indicates hours, minutes and seconds since ignition.) 9:20 AM: (00m:00s) Start test. Ignition. 00m:40s: Smoke alarms 3, 6 and 2 activate. 01m:20s: Smoke alarms 4 and 1 activate. 01m:34s: Smoke alarm 5 activates. 01m:34s: End of test. Test 3 Summary: The Kidde ionization alarm (#3), the Kidde dual sensor alarm (#6) and the First Alert ionization alarm (#2) all sounded at 00m:40s. The Kidde photoelectric alarm (#4) and the First Alert photoelectric alarm (#1) both sounded at 01m:20s. 40 seconds after the first alarms sounded.

The First Alert dual sensor alarm (#5) sounded at 01m:34s. 54 seconds after the first alarms sounded. Test 4: May 12, 2014 at 9:47 am-flaming Test Equipment used: Heat source: Standard wooden kitchen match. Furniture/Fuel Source: Class A combustibles including paper and cardboard in a galvanized tub. Smoke alarms used: 1: First Alert photoelectric sensor. 2: First Alert ionization sensor. 3: Kidde ionization sensor. 4: Kidde photoelectric sensor. 5: First Alert dual sensor (photoelectric & ionization). Model SA320. Date of manufacture: 12-18-12. Two AA batteries. 6: Kidde dual sensor (photoelectric & ionization). Model PI9010. Date of manufacture: 11-29-13. 9 V battery. Carbon monoxide detector used: Carbon monoxide meter: Fire department owned. The make and model number were not recorded. Test 4 Time Line: (Time in hh:mm:ss indicates hours, minutes and seconds since ignition.) 9:47 AM: (00m:00s) Start test. Ignition. 00m:40s: Smoke alarms 2 and 3 activate. 00m:50s: Smoke alarms 4 and 1 activate. 00m:55s: Smoke alarm 6 activates. 01m:00s: Smoke alarm 5 activates. 01m:00s: End of test. Test 4 Summary: The First Alert ionization alarm (#2) and the Kidde ionization alarm (#3) both sounded at 00m:40s. The Kidde photoelectric alarm (#4) and the First Alert photoelectric alarm (#1) both sounded at 00m:50s. 10 seconds after the first alarms sounded.

The Kidde dual sensor alarm (#6) sounded at 00m:55s. 15 seconds after the first alarms sounded. The First Alert dual sensor alarm (#5) sounded at 01m:00s. 20 seconds after the first alarms sounded.

Test 5: May 13, 2014 at 4:34 PM-Smoldering Test Equipment used: Heat source: Weller 110 volt, 25 watt soldering-iron model SP23LK. Maximum temperature of 750 F. (The first soldering iron failed during the test and a second and third were added of the same make and model number.) Furniture/Fuel Source: Sofa. (96x44x39 ) New condition. Jackson Furniture Industries. Body: textile waste fiber, resinated polyester fiber batting, polyurethane foam pad. Seat: polyurethane foam pad, resinated polyester fiber batting. Wood frame. Smoke alarms used: (Mounted to board #1) 1: Kidde photoelectric sensor model P3010H. Date of manufacture: 11-26-13. Sealed 10 yr. lithium-ion battery. 2: First Alert ionization sensor model SA304. Date of manufacture: 8-19-13. 9 volt battery. 3: Kidde ionization sensor model I9010. Date of manufacture: 11-6-14. Sealed 10 yr. lithium-ion battery. 4: First Alert photoelectric sensor. Model P900E. Date of manufacture 9-12-13. 9 volt battery. 5: First Alert dual sensor (photoelectric & ionization) model SA320. Date of manufacture: 3-15-14. Two AA batteries. 6: Kidde dual sensor (photoelectric & ionization). Model PI9010. Date of manufacture: 7-10-13. 9 volt battery. Carbon monoxide detector used: Carbon monoxide meter: Fire department owned. The make and model number were not recorded. Test 5 Time Line: (Time in hh:mm:ss indicates hours, minutes and seconds since first smoke.) 4:34 PM: Start test. Heat on. 4:35 PM: (00m:00s): First smoke. 08m:30s: Light smoke entering hallway. 12m:09s: Smoke alarm 1 activates. 13m:33s: Smoke alarm 4 activates. 14m:06s: Smoke alarm 4 stops sounding. 14m:44s: Smoke alarm 4 activates and stays on.

19m:10s: CO level 1 2 ppm. 20m:00s: Smoke is beginning to bank down to the floor in the living room. 22m:15s: Smoke alarm 5 activates. 27m:18s: CO level 4 5 ppm. 47m:30s: CO meter ceases to function. 49m:00s: Smoke is now to the floor. It is difficult to see. 49m:20s: Smoke alarm 6 activates. 52m:25s: Smoke is rolling across the hallway ceiling and all alarms. 56m:00s: First soldering iron is now destroyed. Replaced with two others. 56m:30s: Smoke alarm 6 stops sounding. 59m:13s: Smoke alarm 6 activates again and stays on. 01h:05m:20s: Visibility less then 10 feet at the floor level. 01h:10m:00s: End of test. Smoke alarms 2 and 3 did not sound during this test. 01h:10m:15s: Smoke alarm 2 test button pushed. Alarm sounds verifying it is operating. 01h:10m:40s: Smoke alarm 3 test button pushed. Alarm sounds verifying it is operating. 01h:13m:00s: Firefighters exit the home. Test 5 Summary: The Kidde photoelectric smoke alarm (#1) sounded at 12m:09s. The First Alert photoelectric smoke alarm (#4) sounded at 13m:33s to 14m:06s then stopped sounding. One minute and 24 seconds after the first smoke alarm sounded. The First Alert photoelectric smoke alarm (#4) sounded again and remained on at 14m:44s. Two minutes and 35 seconds after the first smoke alarm sounded. The First Alert dual sensor alarm (#5) sounded at 22m:15s. 10 minutes and six seconds after the first smoke alarm sounded. The Kidde dual sensor alarm (#6) sounded at 49m:20s. 37 minutes and 11 seconds after the first smoke alarm sounded. The Kidde dual sensor alarm (#6) stopped sounding at 56m:30s. The Kidde dual sensor alarm (#6) sounded again and remained on at 59m:13s. The First Alert ionization alarm (#2) and the Kidde ionization alarm (#3) never activated during this test.

Test 6: May 13, 2014 at 6:48 PM-Flaming Test Equipment used: Heat source: Standard wooden kitchen match. Furniture/Fuel Source: Class A combustibles including paper and cardboard in a galvanized tub. Smoke alarms used: (Mounted to board #2) 1: Kidde photoelectric sensor. Model PE3010H. Date of manufacture: 11-26-13. Sealed 10 yr. lithium-ion battery. 2: First Alert ionization sensor. Model SA304. Date of manufacture: 3-4-14. 9 volt battery. 3: Kidde ionization sensor. Model I9010. Date of manufacture: 2-6-14. Sealed 10 yr. lithium-ion battery. 4: First Alert photoelectric sensor. Model P900E. Date of manufacture: 6-20-13. 9 volt battery. 5: First Alert dual sensor (photoelectric & ionization). Model SA320. Date of manufacture: 3-4-14. Two AA batteries. 6: Kidde dual sensor (photoelectric & ionization). Model PI9010. Date of manufacture: 7-10-13. 9 volt battery. Carbon monoxide detector used: Carbon monoxide meter: Fire department owned. The make and model number were not recorded. Test 6 Time Line: (Time in hh:mm:ss indicates hours, minutes and seconds since ignition.) 6:48 PM: (00m:00s) Start test and ignition. 00m:45s: Smoke alarms 2 and 3 activate 01m:05s: Smoke alarms 5 and 6 activate. 04m:30s: Smoke alarm 1 activates. 05m:19s: Smoke alarm 4 activates. 05m:19s: End of test. Test 6 Summary:

The First Alert ionization alarm (#2) and the Kidde ionization alarm (#3) both activate at 00m:45s. The First Alert dual sensor alarm (#5) and the Kidde dual sensor alarm (#6) both activate at 01m:05s. 20 seconds after the first alarms sounded. The Kidde photoelectric alarm (#1) sounded at 04m:30s. Three minutes and 45 seconds after the first smoke alarm sounded. The First Alert photoelectric alarm (#4) sounded at 05m:19s. Four minutes and 34 seconds after the first smoke alarm sounded.