Vertical Dryer Owner s Manual

Similar documents
INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR DRY PAK PACKAGED COMPRESSED AIR TREATMENT SYSTEM MODEL: DPP-150 WARNING

PIPE LINE DEHYDRATOR FOR NATURAL GAS PLD thru PLD WARNING

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

Air Dryers & After Coolers Dry Land

D Series. Single Tower Deliquescent Dryers FEATURES. No power required. No moving parts. Low pressure drop. 20ºF to 63ºF dew point suppression

The Next Generation PORTABLE COMPRESSED AIR TREATMENT SYSTEM

SUPERIOR PERFORMANCE

Item # /2" NPT, 2 STAGE AIR FILTER/DRYER SYSTEM INSTRUCTIONS

DRYAIRE DESICCANT SYSTEM MODEL 6760

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Desiccant Air Drying System

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR PREP-40 PORTABLE COMPRESSED AIR DRYER SYSTEM model FR-800 (P/N )

MR Series Heatless Mini Regenerative Desiccant Dryer. Operator s Manual

Leading Innovation in Compressed Air Treatment CTS SERIES ELIMINATOR II OIL WATER SEPARATORS

HEATLESS REGENERATIVE COMPRESSED AIR DRYER models THL-200 through THL- 5000

Desiccant Air Drying System

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

SUPERIOR PERFORMANCE

Flexible Solutions for Air Quality

Single Tower Heat Reactivated Desiccant Air Dryer

Making Compressed Air and Gas Work Better

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

Model OP155 Air Dryer

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

Refrigerated & Desiccant Compressed Air Dryer Product Selector

DAD-500 (130026) DESICCANT AIR DRYING SYSTEM

Regenerative Desiccant Dryers. KAD, KED, KBD and Hybritec Series

HEAT OF COMPRESSION DESICCANT AIR DRYERS. DHC Series

Condensate Drain Valves

A Primer for Air Dryer Selection

Heat of Compression Desiccant Air Dryers. HOC SERIES scfm ( nm 3 /h)

! WARNING. Replacement Head Mechanism INSTRUCTION MANUAL MM-413F

Compressed Air Dryers

DAD-500 (130026) DESICCANT AIR DRYING SYSTEM

HEATLESS REGENERATIVE DRYERS

Installation, Operation and Maintenance Manual for Model 8331 Condensate Accumulator

Quality Components as a basis for Quality Equipment

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

OPERATING INSTRUCTIONS

EXTERNALLY HEATED DESICCANT AIR DRYERS. GEHD Series

DRYAIRE MEMBRANE AIR DRYING SYSTEM MODEL 6770

20 21,250 SCFM GLOBAL AIR TREATMENT. FIL Series

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

TITAN FLOW CONTROL, INC.

Regenerative Desiccant Dryers. KAD, KED, KBD, and Hybritec Series. kaeser.com

EXTERNALLY HEATED BLOWER PURGE DESICCANT AIR DRYERS. GBPD Series

SECTION AIR COMPRESSORS AND ACCESSORIES

BLAST-IT-ALL PRESSURE BLAST CABINET

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

FACT SHEET 3. Efficient Compressed Air Treatment. How to save energy, reduce costs and help the environment

SUPERIOR PERFORMANCE

Hybrid Refrigerated/Desiccant Compressed Air Dryers

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250

Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers

OPERATING INSTRUCTIONS

Heat of Compression Desiccant Air Dryers. HCD SERIES scfm ( nm 3 /h)

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

Heat of Compression Desiccant Air Dryers. NRG-LES SERIES scfm ( nm 3 /h)

Refrigerant Recovery Unit, Model RRU134

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

Corrosion Dry Air Pak

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

PORTABLE AFTERCOOLER MODEL CA-350 PORTABLE AFTERCOOLER/FILTER AFTERCOOLER OPERATION MANUAL

WARNING THE MAGNUM PRESSURE BLAST CABINET

MANUAL. Dryspell INSTALLATION OPERATION MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

DS Series. Ultraaqua Autoclean. Oil/Water Separators

ERGOMAX 7 INSTALLATION

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS

Laboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package

Dry Air Pac ENGINEERED COMPRESSED AIR DRYING SYSTEMS FOR COLD STORAGE/ FREEZER ROOM DRY PIPE SPRINKLER SYSTEMS

Installation, Operation, and Maintenance Manual Balston Model 76-01, 76-02, 76-10, and Membrane Air Dryers

MODULAR HIGH CAPACITY REFRIGERATED AIR DRYERS. GMRN & GMRC Series

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

Compressed Air Specialists

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

INFINITY FLUIDS CORPORATION

Niles Steel Tank Hot Water Generator Installation and Operation Manual

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252

SECTION COMPRESSED-AIR EQUIPMENT FOR LABORATORY FACILITIES

Installation and Maintenance "L" and "LS" Series

VSA Series Air Dryer. User s Guide

BLASTMASTER 1600 CFM AIR DRYER

Installation & Operation Manual Models:

Silhouette. Feedwater Heater. Boiler Feedwater

CMMD Series Membrane Air Dryer

SECTION AIR COMPRESSORS AND ACCESSORIES

BLAST-IT-ALL BUMPER BLASTER

Compressed air preparation Compressed air storage Moisture management. Catalog #1

MST MODEL S1 AIRLINE "CO" MONITORING AND LOW PRESSURE WARNING SYSTEM MANUAL

PDF Created with deskpdf PDF Writer - Trial ::

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

OIL/WATER SEPARATORS. Compressed Air & Process Filtration

Compressed Air Filters

Scroll Medical Air Compressor with Premium NFPA Control Panel

Chapter 9: The basics of air preparation

Transcription:

DSV-250, DSV-450, DSV-750, DSV-1000, DSV-1200 & DSV-1600 Models Model DSV-250 DSV-450 DSV-750 DSV-1000 DSV-1200 DSV-1600 Regulator Setting For Air Motors 22 PSI TO GET 3450 RPM 20 PSI TO GET 1725 RPM 22 PSI TO GET 1725 RPM 22 PSI TO GET 1725 RPM 30 PSI TO GET 1725 RPM 20 PSI TO GET 1725 RPM SUPERIOR PERFORMANCE And Quality In Blast Cleaning Equipment! WARNING Read Manual Failure to read, understand & follow all safety and operation procedures in this manual can cause injury or death. Manuals that are lost, incomplete, or damaged, must be replaced immediately. Manual # DSV1708 Ph: (780) 425-5510 Fax: (780) 425-5540 Copyright 2017 Mod-U-Blast, All Rights Reserved

Table of Contents Important Warning... 3 How it Functions... 4 Performance... 4 Operating Instructions... 5 Maintenance Instructions... 6 Parts List... 7 Maintenance Checklist... 8 Warranty Information... 9 Contact Information... 9 2 Copyright 2017 Mod-U-Blast, All Rights Reserved

Important Warnings DO NOT OPERATE THIS SYSTEM ABOVE MAXIMUM WORKING PRESSURE (MWP) AND/OR MAXIMUM OPERATING TEMPERATURE (OF) SHOWN ON THE VESSEL ASME DATAPLATE. THIS ASME CODE VESSEL MUST BE PROTECTED BY A PRESSURE RELIEF VALVE. Refer to OSHA 1910.169 Par. b, Sub. Par (3) and ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, UG-125 through UG-136. Also comply with all applicable provincial, state and local codes. DO NOT ATTEMPT TO REMOVE OR REPAIR ANY PART OF THE SYSTEM UNTIL IT IS COMPLETELY DEPRESSURIZED. SERIOUS PERSONAL INJURY OR DEATH MAY RESULT IF THIS RULE IS NOT FOLLOWED. DO NOT WELD OR GRIND ON VESSEL, THIS WILL MAKE IT UNSAFE TO USE. (Note: Any alteration to the vessel will void the ASME Code Certification and the warranty.) INSPECT THE VESSEL, INSIDE AND OUT, REGULARLY FOR CORROSION, DENTS, GOUGES OR LEAKS. IF DAMAGED, REMOVE FROM SERVICE IMMEDIATELY. DO NOT TRY TO TIGHTEN A LEAKING COVER. IMMEDIATELY SHUT OFF THE AIR SUPPLY AND DEPRESSURIZE THE SYSTEM. DO NOT ATTEMPT TO REMOVE THE FILL COVER UNTIL THE SYSTEM IS COMPLETELY DEPRESSURIZED. WHEN THE VESSEL PRESSURE IS REDUCED TO ZERO, THE FILL COVER CAN BE REMOVED BY HAND. INSTALL A NEW GASKET AT LEAST ONCE PER YEAR. INSPECT THE FILL COVER AND SEALING SURFACE FOR DAMAGE SUCH AS CORROSION, CRACKS, OR DISTORTION. IF THERE IS ANY DAMAGE, REPLACE THE FILL COVER. REPLACE THE FILL COVER EVERY FOUR YEARS REGARDLESS OF CONDITION. USE MOD-U-BLAST AUTHORIZED PARTS ONLY. DO NOT USE POWER TOOLS TO TIGHTEN THE NUT ON THE FILL COVER. TOO MUCH FORCE CAN DISTORT THE FILL COVER AND/OR THE GASKET. IF DAM-AGED BY OVER-TIGHTENING, THE FILL COVER CAN BLOW OUT AND CAUSE SERIOUS INJURY OR DEATH. (Note: Tighten the nut until it is snug. When the vessel is pressurized, the pressure on the fill cover will complete the seal.) THE USE OF PRODUCTS OTHER THAN MOD-U-BLAST DESICCANT WILL VOID THE WARRANTY. 3 Copyright 2017 Mod-U-Blast, All Rights Reserved

How it Functions DRY-PRO by MOD-U-BLAST Single Tower, Deliquescent, Air Dryers are a skid mounted system which includes an aftercooler, a coalescing filter and a single tower dryer filled with desiccant tablets. Warm air enters the aftercooler where it is cooled close to the surrounding temperature, water is then condensed out during this cooling process. The saturated air and the liquid water pass through a coalescing filter where any oil contaminants from the compressor are removed and then proceeds to the inlet of the dryer tank. The water and any solid particles present are separated by gravity and fall to the bottom of the dryer tank. The air moves up through the desiccant tablets which absorb the moisture from the air before it flows through the dryer outlet. The tablets dissolve gradually as they absorb the moisture. The dissolved desiccant and water, falls into the bottom of the vessel. The dryer must be drained periodically to remove the accumulated solution. A manual ball valve is installed for this purpose. Performance DRY-PRO by MOD-U-BLAST Vertical Dryers are rated as follows: 250 CFM (DSV-250) - 450 CFM (DSV-450) - 750 CFM (DSV-750)- 900 CFM (DSV-1000) - 1200 CFM (DSV1200) - 1600 CFM (DSV-1600) at 100 PSI. Approach temperatures will vary with changes to the inlet conditions (flow, pressure, temperature) and the ambient temperature. The dew point out of the dryer tower is directly related to the inlet temperature entering the dryer vessel. The lower the inlet temperature, the lower the dew point of the outlet air. The aftercooler maximum inlet temperature is 250 F. When using MOD-U-BLAST desiccant, the inlet temperature to the dryer tower should not exceed 100 F. Maximum Capacities for Dryer - CFM (Cubic Feet Per Minute) Model Maximum 80 PSI 100 PSI 125 PSI 150 PSI 175 PSI 200 PSI DSV-250 200 PSI 210 250 305 360 415 470 DSV-450 200 PSI 330 450 500 575 660 750 DSV-750 200 PSI 630 750 960 1130 1300 1475 DSV-1000 200 PSI 720 900 1000 1160 1350 1600 DSV-1200 200 PSI 990 1200 1460 1720 2045 2430 DSV-1600 200 PSI 1320 1600 1950 2300 2730 3245 Pressure & CFM Requirements for Air Motors Air Motor Size Working Pressure PSI Maximum Pressure PSI CFM Required 250 22 60 17 450 22 40 25 750 22 40 25 1000 22 50 70 1600 20 60 150 NOTE: Working pressure is at 21 C (70 F) ambient temperature. In warmer weather the air motors can be operated up to or at the maximum pressure. 4 Copyright 2017 Mod-U-Blast, All Rights Reserved

Operation DESICCANT: See below for desiccant refilling. IMPORTANT! Our DRY-PRO by MOD-U-BLAST Vertical Air Dryers are shipped with the desiccant installed. The desiccant will NOT be installed if the unit is being shipped overseas at which point the proper amount of desiccant will be shipped with the dryer and must be installed before using the system. LUBRICATOR OIL: Check oil level in lubricator regularly and add oil as required. (Automatic Transmission Fluid) IMPORTANT! Our DRY-PRO by MOD-U-BLAST Vertical Air Dryers are shipped WITHOUT the lubricator oil installed. Lubricator oil (ATF) MUST BE INSTALLED before using the system. FAILURE TO MAINTAIN OIL LEVEL WILL CAUSE THE FAN MOTOR TO SEIZE START UP PROCEDURES: Connect your compressor (fittings not included) to the DRY-PRO Vertical Dryer inlet, start compressor, then SLOWLY open the ball valve to pressurize the dryer. Make sure that the DRY-PRO Vertical Air Dryer is not subjected to sudden air surges. Always open the valves slowly to permit gradual air pressure between the Dryer and the compressor. *Check that the regulator pressure is set as shown on cover page of this manual to maintain the fan speed rpm ensuring proper aftercooler performance.* The DRY-PRO Vertical Air Dryer requires certain procedures to ensure best performance: 1. DAILY DRAINING The desiccant and water solution in the bottom of the dryer should be drained often. The manual drain valve is installed on the dryer, must be opened at least once every 4 to 8 hours to drain the dryer. The dryer will require draining more often on humid days. *If the dryer is not drained regularly, it may become flooded and the accumulated liquid WILL enter the air system.* 2. REFILLING THE DRYER WITH DESICCANT During the drying process, the desiccant tablets dissolve slowly. The desiccant consumption rate is dependent on several factors, such as inlet temperature, flow and pressure. To check the level of the desiccant, look into the sight window, if you can t see the desiccant tablets then the tank has to be refilled to ensure peak dryer performance. 5 Copyright 2017 Mod-U-Blast, All Rights Reserved

Maintenance Procedures Danger: Never perform any maintenance or attempt to open the Vertical Dryer in any way while it is pressurized. The violent release of compressed air and propelled objects will cause serious injury or death. Warning: Maintenance procedures are to be performed by experienced qualified personnel only, Failure to perform maintenance procedures correctly at the intervals specified below can lead to performance problems and equipment failure, and will void the equipment warranty. Warning: Make sure the desiccant level is below the outlet pipe. Do NOT overfill the vessel. Space must be left to allow for the fill cover to be installed. Maintenance Schedule Procedure to be Performed Maintenance Interval Check Dessicant Level Look into the sight window, if the desiccant is not visible then top it off. Check the operation of all equipment installed before and after the DRY-PRO dryer. Check Oil Level In Lubricator Verify that there is sufficient amount of oil in the lubricator and add oil as needed. ATF only (Automatic Transmission Fluid) Clean Aftercooler Core The core should be cleaned regularly. Accumulation of dirt or oils will greatly reduce the efficiency of the aftercooler. Dirt can be removed by blowing the core off with compressed air. If the core becomes coated with oil particles, it can be steam cleaned. Adding Desiccant Shut down the air compressor and open the drain valve to allow the dryer to depressurize completely. Loosen the nut on the fill cover. Push on the fill cover. Once the seal is broken, remove the fill cover from the dryer. Add the amount of desiccant needed to restore to the maximum level. Coalescing Filter Check the condition of the oil removal filter element every 6 months and change annually. Some filters have a differential pressure indicator and when the RED button pops up in the indicator it is time to replace the element. When replacing the element make sure to clean and inspect the drain port. Fill Cover Inspection Inspect the fill cover and sealing surface. Should there be damage, replace the cover. Replace the fill cover every 4 years regardless of condition. The gasket should be replaced at least once a year. Check the sealing surface of the opening. If it has dirt or rust on it, then it must be cleaned before installing the fill cover. Install the fill cover and gasket. Tighten the nut on the fill cover until it is snug. Over tightening will cause damage gasket. The fill cover will seal when the vessel is pressurized. Every 8 Hours of Use Every 8 Hours of Use Every 8 Hours of Use Every 6 Months Every 4 years 6 Copyright 2017 Mod-U-Blast, All Rights Reserved

Parts List Description Stock # DSV-250 DSV-450 DSV-750 DSV-1000 DSV-1200 DSV-1600 QTY QTY QTY QTY QTY QTY Gasket for 4 x6 Fill Cover 22618 1 1 1 1 1 1 Fill Cover, 4 x 6 22619 1 1 1 1 1 1 Sight Glass SP-A-28905 1 1 1 1 1 1 Manual Drain Valve for Tank 1 NPT 65-800 1 1 1 1 1 1 Sight Glass SP-A-28905 1 1 1 1 1 1 Thermometer 20114 1 1 1 1 1 1 Air Motor for Aftercooler DAC-AMV4 1 1 1 Air Motor for Aftercooler DAC-AM6 1 1 Air Motor for Aftercooler DAC-AM16 1 Element - SMC DSC-250-EL 1 Element - SMC DSC-450-EL 1 Element - Van Air DSC-750-EL 1 Element - MUB* DSC-250-DEL 1 Element - MUB* DSC-450-DEL 1 Element - MUB* DSC-750-DEL 1 Element - MUB* DSC-1000-DEL 1 Element - MUB* DSC-1200-DEL 1 Element - MUB* DSC-1600-DEL 1 Coalescer Pop-Up Indicator - SMC SP-INA-63280 1 1 Coalescer Pop-Up Indicator - Van Air SP-8410125 1 Coalescer Differential Pressure Gauge - MUB* DSC-DPG 1 1 1 1 1 1 Pressure Relief Valve 1 @ 200 PSI 51810-200 1 1 1 1 1 1 Pressure gauge - 160 PSI DESICCANT 55415 1 1 1 1 1 1 MOD-U-BLAST Desiccant, 50 LB BAG 79000 4 6 8 20 24 25 *MUB - Mod-U-Blast model **DSV-1200 parts may be special order Parts Ordering: 1-800-661-3842 7 Copyright 2017 Mod-U-Blast, All Rights Reserved

Maintenance Checklist DATE Service Completed 8 Copyright 2017 Mod-U-Blast, All Rights Reserved

Warranty Mod-U-Blast equipment is covered by a one (1) year warranty against defects in material and workmanship starting from the purchase date. This covers the equipment as well as all major components. This warranty does not apply to abnormal use of the equipment or parts. Parts considered consumables are not covered by the warranty. Claims will be honored only if the warranty card is returned within a period of two (2) months from the factory shipping date. The card can be returned to your Mod-U-Blast salesperson or mailed to the address below. In the event of failure of this equipment please contact a Mod-U-Blast service centre or call (780) 425-5510. 403-69 Avenue NW Edmonton, Alberta Canada T6P 0C2 PH: (780) 425-5510 FAX: (780) 425-5540 VISIT WWW.MANUSSERVICE.COM FOR ONLINE PRODUCT SUPPORT 9 Copyright 2017 Mod-U-Blast, All Rights Reserved