WARNING This information is a copy of an original archive, therefore Aga cannot be held responsible for its continued accuracy.

Similar documents
THE SEVERN. Installation Instructions for Freestanding Severn Stove with Boiler PERFORMANCE RATING

THE MUCH WENLOCK. Installation Instructions for Freestanding Much Wenlock Stove with Boiler

Installation Instructions. Rayburn 300W Wood Burning Cooker

THE MUCH WENLOCK. Operating Instructions for Freestanding Much Wenlock Stove with Boiler

THE SEVERN. Operating Instructions for Freestanding Severn Stove with Boiler

Installation & Servicing Instructions for Rayburn 300K and Rayburn 308K Oil-Fired Cooker

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH

400GL PX (PF) Servicing Instructions. For use in GB and IE PLEASE READ THESE INSTRUCTIONS BEFORE SERVICING THIS APPLIANCE

AGA TOTAL CONTROL. Model No s: TC3 & TC5 (ROOM VENT OPTION)

TRH 45 MK4 SOLID FUEL ROOM HEATER USER AND INSTALLATION INSTRUCTIONS

WARNING This information is a copy of an original archive, therefore Aga cannot be held responsible for its continued accuracy.

400G/L PX (CF) Servicing Instructions. For use in GB and IE PLEASE READ THESE INSTRUCTIONS BEFORE SERVICING THIS APPLIANCE

PLEASE READ THESE INSTRUCTIONS BEFORE USING THIS APPLIANCE

Users Instructions. Rayburn Heatranger 355SFW Solid Fuel and Wood Burning Cooker

BERRINGTON SOLID FUEL BOILER STOVE

Installation and Servicing Instructions for Rayburn 200G/L Gas Fired Cooker

STATEMENT OF SOLID FUEL APPLIANCE PERFORMANCE

Newton Multi Fuel 5kW Space Heating Stove

CHARNWOOD COUNTRY 8B WOODBURNER OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550

Ludlow Non-Boiler (Multi-Fuel)

Newton Multi Fuel 8kW Space Heating Stove With Boiler

INSTALLATION INSTRUCTIONS

WOLVERTON STOVES U S E R M A N U A L S h A N d o N / A R d L E i g h

WARNING This information is a copy of an original archive, therefore Aga cannot be held responsible for its continued accuracy.

Little Wenlock Classic

CHARNWOOD COUNTRY 6 FT

Operating Instructions for AGA Gas Fired Cooker Models GC, GCB, (2 Oven) 2=

Operating Instructions for AGA BF Gas Fired Cooker Models GC, GCB, (2 Oven) 2=

Riva F40 Cube. Multi-Fuel Free Standing Stove. Installation Instructions. Models: RVF40C. For use in Great Britain and Eire IMPORTANT

Course introduction 2. 1 Appliances and fuels 3. 2 Combustion Legislation Air supply Flues and chimneys Commissioning 83

charnwood Operating & Installation Instructions

charnwood country 4MKII Operating & Installation Instructions

Donard Solid Fuel Cooker

Little Wenlock Solid Fuel Stove

Ludlow Wood Burning Smoke Exempt Stove

IMPORTANT. Users Instructions for Rayburn 200SFW and Rayburn 212SFW Solid Fuel Cooker

Users Instructions for Rayburn 200 G/L Gas-Fired Cooker

BRANDON DRY & DHW OIL MODELS

TC MODULE (FFD) (with Gas Hob)

Stockton 7 & 8 Inset Convector Stove

MUCH WENLOCK BOILER SOLID FUEL STOVE

Donard Solid Fuel Cooker

Erin Non Boiler Solid Fuel Stove

IMPORTANT. Users Instructions for Rayburn Heatranger 216SFW Multi-Fuel Cooker. Better than you ever imagined INTRODUCTION

TECHNICAL MANUAL. Multifuel Stove Model EW1MF. To be retained by the user for future reference. Serial Number. Document EW1MF 0209

Mendip 5 standard and pedestal stove Multi-Fuel, Wood, Smoke control model 4.8 kw / 5.2kW Space Heating Stove

charnwood country 16b multi-fuel Operating & Installation Instructions

MUCH WENLOCK CLASSIC NON-BOILER SOLID FUEL STOVE

charnwood SLX45MKII MULTI-FUEL Operating & Installation Instructions

Dovre 700CBW Cast Iron Wood Stove INSTALLATION INSTRUCTIONS 700G/1095

Oscar Solid Fuel Stove

H E R A L D 1 4 C E V. I I

charnwood Operating & Installation Instructions

Installation Instructions

Stockton. Clean-burn stove. MODELS: 3 MF/4 Wood/4 MF/5 MF. Installation and Operating Instructions. For Use in Great Britain and Eire

AGA 13 AMP RETRO-FIT WITH AIMS

Dovre 250 Cast Iron Gas Stove

charnwood Operating & Installation Instructions

H E R A L D 8 0 B. Installation and Operating Instructions

Commissioning of Heat Producing Appliances Burning Solid Fuel

C O N S O R T 9. Installation and Operating Instructions

Inset Chevin 20B. Installation and Operating Instructions. JINCHW09 Rev A 12/05/14

Shawbury Wood Stove. (Smoke Exempt)

Wet stove installation guide

Chimney Renovation Kit

AGA DUAL CONTROL Model No s: DC3 & DC5. (Includes External Vent & Room Vent Option)

charnwood Operating & Installation Instructions

charnwood Operating & Installation Instructions

Twin Wall Installation Instructions And Maintenance Guide

charnwood I S L A N D Operating & Installation Instructions

HIGHLANDER Wood and Multi-fuel Stoves

FIONN SOLID FUEL BURNING STOVE INSTALLATION AND OPERATING INSTRUCTIONS

CELT STAR C GAS-FIRED WATER HEATER. Category: I 2E+ Installation and Use Instructions. Contents : Description:

680KCD 780KCD. Installation Instructions

EMBERGLOW CLASSIC RADIANT CONVECTOR GAS FIRE. Installation and Maintenance Instructions

Heatranger 440/460/480/499KB

TECHNICAL MANUAL. The Buxton. Multifuel Stove Model BX1MF. To be retained by the user for future reference

Troubleshooting Guide

Oisin Solid Fuel Stove

Oisin Solid Fuel Stove

CE EN13240 ENJOY YOUR STOVE SAFELY. Multifuel Cast Iron Stove INSTRUCTION MANUAL

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE

Emberglow COAL EFFECT BALANCED FLUE GAS FIRE

Hanwood Wood Stove. (Smoke Exempt)

Westbury Wood Stove. (Smoke Exempt)

GB IE. VALOR BOLERO (MODEL BR626) Inset Decorative Fuel Effect Gas Fires. For

Dorrington Wood Stove

Annex 5a Solid fuel (Domestic) Annex 5a Common Minimum Technical Competency Requirements for Solid fuel burning appliance installation (domestic)

15 20 kw kw kw

morsø PANTHER GAS STOVE

PLEASE RETAIN. Cara+ Solid Fuel High Output Boiler. Insert Stove INSTALLATION AND OPERATING INSTRUCTIONS

Cara Glass Non Boiler Insert Stove

Ashling Boiler & Non Boiler Solid Fuel Stove

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

TECHNICAL MANUAL. Multifuel Stove Model MV1MF. To be retained by the user for future reference

OWNER GUIDE. Model 750. INSET LIVE FUEL EFFECT GAS FIRE Fitted with Harmony, Avignon or Style fascia. (GC No )


charnwood Operating & Installation Instructions

Transcription:

WARNING This information is a copy of an original archive, therefore Aga cannot be held responsible for its continued accuracy.

Coalbrookdale DARBY Stove with boiler Additional Information The Darby stove was originally offered with two boiler options. The Intermediate Boiler model had a heat exchanger attached to the rear of the standard firebox used on the Non-boiler models. It had an approximate output of 5.8 kw/h to water, + 10.2 kw/h to room. Control was by manually operated air spinwheels. The High-Output boiler model had a re-designed firebox/boiler assembly with approximate outputs of 12.3 kw/h to water + 8.2 kw/h to room. Control was by an automatic water temperature sensing thermostat, the air spinwheels in this case being fixed.

THE DARBY Installation Instructions for Freestanding Darby Stove Boiler and Non-Boiler Model Consumer Protection Act 1987 As manufacturers and suppliers of cooking and heating products, in compliance with Section 10 of the Consumer Protection Act 1987, we take every care to ensure, as far as is reasonably practicable, that these products are so designed and constructed as to meet the general safety requirement when properly used and installed. To this end, our products are thoroughly tested and examined before despatch. IMPORTANT NOTICE: Any alteration that is not approved by Aga- Rayburn, could invalidate the approval of the appliance, operation of the warranty and could also affect your statutory rights. Control of Substances - Health & Safety Important This appliance may contain some of the materials that are indicated below. It is the Users/Installers responsibility to ensure that the necessary personal protective clothing is worn when Non-Boiler Model: Fig. 1 The appliance can be installed as a back outlet flue only. Boiler Model: Fig. 2 There are two sets of back outlet flow and return connections on the L.H. or R.H. side of the boiler. The stove can be installed as a back outlet flue only. handling where applicable, the pertinent parts that contain any of the listed materials that could be interpreted as being injurious to health and safety, see below for information. Firebricks, Fuel beds, Artificial Fuels - when handling use disposable gloves. Fire Cement - when handling use disposable gloves. Glues and Sealants - exercise caution - if these are still in liquid form use face mask and disposable gloves. Glass Yarn, Mineral Wool, Insulation Pads, Ceramic Fibre, Kerosene Oil - may be harmful if inhaled, may be irritating to skin, eyes, nose and throat. When handling avoid inhaling and contact with skin or eyes. Use disposable gloves, face-masks and eye protection. After handling wash hands and other exposed parts. When disposing of the product, reduce dust with water water spray, ensure that parts are securely wrapped. WARNING BOILER MODEL UNDER NO CIRCUMSTANCES MUST THE APPLIANCE BE FIRED DRY AS DAMAGE WILL OCCUR 9/00 EINS 33725

The Darby Stove with Boiler is intended to provide space heating and the heating of domestic hot water and radiators whilst the non-boiler model provides space heating only. Non-Boiler Model Direct Space Heating Boiler Model Direct Space Heating Water Heating Direct Space Heating Pipe and Radiator Surface Radiator Surface PERFORMANCE RATING kw Btu/h Rating Smokeless Fuel kw Btu/h kw Btu/h The maximum room size (of normal construction) and radiator surface that can be heated are: m 3 ft 3 m 3 ft 3 m 3 ft 3 16.1 55,000 8.2 28,000 12.3 42,000 159 *5,600 24.4 262.5 22.0 237.5 Room Size m 3 ft 3 Coal 8.8 30,000 11.7 40,000 170 *6,000 23.2 250.0 20.9 225.0 247.5 8800 Wood 7.2 25,000 8.8 30,000 141 *5,000 17.4 187.5 12.3 132.5 4. It is recommended that a gravity heat leak radiator 0.9-1.4m 2 (10-15ft 2 ) heating surface be included, or a reverse acting cylinder thermostat to activate the pump in the event of overheating. 5. NOTE: IF THERE IS A POSSIBILITY OF BOILING TAKING PLACE A REVERSE ACTING THERMOSTAT (SUCH AS THE SATCHWELL TYPE 5A) SHOULD BE FITTED TO THE CYLINDER OR PRIMARY FLOW PIPE AND ELECTRICALLY CONNECTED TO THE CENTRAL HEATING WATER CIRCULATOR, THIS WILL SWITCH ON THE WATER CIRCULATOR TO PREVENT BOILING. 6. Boiler - Recommendation Water circulators which are continually operative will in conjunction with prolonged burning under banked conditions create cool boiler surfaces within the firebox. This in turn will encourage boiler surface condensation followed by surface condensation and reduced life span of the boiler. To minimise this incident we strongly recommend a water pipe clamp on thermostat e.g. EBERLE Type 8750 or SATCHWELL SUNVIC Type PA fitted to the Heating Return pipe sited close to the appliance. The thermostat should be electrically connected to the water circulator as indicated on the Typical Wiring Diagram Fig. 3 and the adjustable dial should be set at a temperature of 50 C (122 F). A fall in the return pipe water temperature below 50 C interrupts the power to the water circulator which will then not operate until the temperature exceeds 50 C and power is restored. The recommended heating surface area is based on an average heat emission of 0.5 kw/m 2 (160 Btu/h/ft 2 ). These figures are maxima and must not be exceeded. A margin (about 10% or 1.4m 2-15ft 2 ) is recommended. NOTE: FIGURES MARKED * ARE MAXIMUM WITH WATER LOAD AT FULL OUTPUT. HOT WATER SYSTEM 1. A 140 litre (30 gallon) capacity indirect hot water storage cylinder of the double feed pipe, complying with BS 1566 Part 1: DF Type 8 should be lagged and fixed vertically as near as possible to the stove. The 28mm minimum diameter primary flow and return pipes must not exceed 10m in length and pipes longer than 5m must be lagged. Ensure that the flow pipes rise continuously from the stove boiler to the cylinder to ensure good gravity circulation. In combined systems, the water draw-off pipes to the taps must be dead leg connections from the vent/expansion pipe. 2. One boiler flow connection (preferably that to the cylinder), must have an open vent. The connection to the boiler must be such that air cannot be trapped in the boiler. Any pipe size reduction must be made on the vertical pipe of the vented flow pipe. The heating flow and return pipes may be 22mm and should preferably be connected to opposite tappings to each other on each side of the boiler. 3. All installations must be fitted with a drain tap at the lowest point of the system. THE CHIMNEY For correct operation of the appliance, the height of the chimney from its base should not be less than 5.5m and terminate above the roof in accordance with current Building Regulations and requirements as outlined in BS 6461 Part 1 and BS 7566 Parts 1-4 should be observed. The structural flue through the chimney should not be less than 200mm diameter. Pargeted lined flues, 230mm x 230mm must be in sound condition, and any internal offsets should not be less than 60 to the horizontal. Check that the flue exit is not obstructed or reduced in size. 2

IMPORTANT: FAILURE TO OBSERVE THE RECOMMENDED MINIMUM SIZES OR METHODS OF FLUE CONNECTION MAY LEAD TO FUME EMISSION INTO THE ROOM AND REDUCED BURNING RATES. Existing Chimney The internal and external condition of the chimney should be checked before the appliance is installed and rectification made where necessary to prevent air leakage or porosity. The flue through the chimney should be formed with 200mm diameter minimum moisture and acid resistant liners to BS 1181 or precast linings such as specified in the current Building Regulations and requirements in BS 6461 Part 1 and BS 7566 Parts 1-4 should be observed. When repairing chimneys, it is recommended that the Building Inspector be consulted before the commencement of work with particular attention to the chimney height and its termination. NOTE: THE CHIMNEY SHOULD BE SWEPT BEFORE INSTALLATION. 3 Where the chimney is believed to have served an open fire installation it is possible that the higher flue gas temperature from a closed appliance may loosen deposits that were previously firmly adhered, with the consequent risk of flue blockage. It is therefore recommended that the chimney be swept a second time after one month of regular use. New Chimney The flue should not be less than 200mm diameter and its soundness confirmed by smoke testing or contacting HETAS LTD who will give advice on the test method. Ensure the chimney liners are free of any internal projections such as building jointing composition before the appliance is installed. Factory-Made Insulated Chimney It is recommended that the internal face of the chimney be refractory lined and otherwise comply with BS 4543.

The recommended minimum diameter is 200mm and chimney manufacturers should be consulted for further advice. Chimney Terminations All chimneys should terminate above the roof level in accordance with current Building Regulations and as outlined in BS 6461 Part 1 and BS 7566 Parts 1-4. However well designed, constructed and positioned, the satisfactory performance of a flue can be adversely affected by the downdraughts caused by adjacent tall buildings and trees or even nearby hills. These deflect the wind creating a zone of high pressure over the terminal causing it to blow directly down the chimney flue. A suitable anti-downdraught terminal such as the Marcone will usually effectively combat low pressure down-blow but no known cowl is likely to prevent downdraught due to a high pressure zone. NOTE: ADVISE THE USER TO ENSURE THE CHIMNEY FLUES ARE THOROUGHLY SWEPT AT A MINIMUM OF 12 MONTHLY INTERVALS AFTER THE APPLIANCE IS COMMISSIONED. PREPARATION OF BUILDERS RECESS OPENING The appliance and recess, hearth and chimney flue installation should be in accordance with the current recommendation of the British Codes of Practice BS 8303, BS 6461 Part 1 and BS 7566 Parts 1-4, with the boiler and heating installation complying with BS 5449 Part 1. The boiler section must also be installed in accordance with the byelaws of the Local Water Undertaking, Regulations for the Electrical Equipment of Buildings - published by the Institute of Electrical Engineers and any relevant requirements of the Local Authority. The appliance can be installed in a non-combustible recess in which the hearth must be level and together with the adjacent walls, conform to the current Building Regulations. The clearance between the appliance and any combustible material must be maintained as indicated in Figs 4a, 5a, 5b and 6. AIR SUPPLY A Permanent unobstructed air vent is required having a minimum effective area of 86cm 2 and communicating directly to outside air or an adjacent room which itself has a permanent air vent direct to outside air. Effect of Extractor Fan Avoid if possible, the installation of an extractor fan in the same room as the appliance or the room where the permanent vent is located. Compensating extra air inlets must be introduced equivalent to the capacity of the fan when fitted. FLUE LAYOUT Figs. 4a and 4b show the stove connected to an existing brick chimney with vertical flue pipe connected to the stove with a right angled tee piece. Support brackets are recommended to support weight of flue connecting pipes. The exit end of the flue pipe must extend a minimum of 150mm into the overhanging brickwork. Any cavities or pockets above the register plate should as far as possible, be filled with the flue pipe exit extended into the throat of the chimney. If a flue liner or insulated chimney is used, the diameter should not be less than 200mm in both cases. Figs 5a and 5b. 4

Figs. 5a and 5b show a brick flue outlet into a chimney brickwork. EXTENDED LENGTHS OF HORIZONTAL PIPEWORK MUST BE AVOIDED AND ARE NOT RECOMMENDED, AND SHALL NOT EXCEED 150mm. NOTE: WHATEVER METHOD OF INSTALLATION IS UTILISED, AIR MUST NOT BE ALLOWED TO ENTER THE CHIMNEY EXCEPT THROUGH THE STOVE AND ALL JOINTS MUST BE AIRTIGHT. IF THE CHIMNEY IS UNLINED AND THERE IS ANY DOUBT ABOUT ITS CONDITION, IT SHOULD BE LINED IN ACCORDANCE WITH THE CURRENT BUILDING REGULATIONS. PROVISION MUST ALWAYS BE MADE FOR SWEEPING THE CHIMNEY. IMPORTANT: CEMENT PIPES AND FITTINGS MUST NOT BE USED WITHIN 2m OF THE STOVE OUTLET. CHIMNEYS OF PLAIN PIPE ARE NOT RECOMMENDED BUT CERTAIN PROPRIETARY MAKES OF INSULATED CHIMNEY ARE SUITABLE. 6. Check that the bottomgrate reciprocates correctly and that the throat plate is correctly located/sealed. Boiler Model Only 7. Plug any of the 1in BSP boiler connections not required and fit half unions as required. 8. Check and if necessary re-set thermostat valve plate setting. See Fig. 7. INSTALLATION Handle the firedoor with care to ensure the glass panels remain intact. The stove is delivered fully assembled but all fire cement joints should be examined for soundness and if necessary, resealed before installation. After unpacking the stove, remove all packaged parts from inside the stove and inspect the stove to ensure no damage has occurred during delivery. If there is a problem contact your nearest stockist. Packaged parts contain a Flue Collar and Operating Tool Support Cradle complete with two screws to secure the Cradle to the bottom R.H. side of the stove. NOTE: THE FLUE COLLAR SUPPLIED WITH THE STOVE IS SUITABLE FOR USE WITH VITREOUS ENAMEL STEEL PIPE. A SPECIAL FLUE COLLAR IS REQUIRED FOR CONNECTION TO CAST IRON FLUE PIPE OR A CAST IRON TEE PIECE. SPECIAL FLUE COLLARS ARE AVAILABLE THROUGH YOUR LOCAL COALBROOKDALE STOCKISTS. 1. Fix flue connector to rear of stove with screws provided. 2. Position the stove in required position relative to chimney flue and on non-combustible hearth ensuring there is sufficient room allowed: a. On stove R.H. side to enable operation of riddling tool. Fig. 6. b. At rear of L.H. side of stove to give access for replacement of thermostat of high output boiler model. See Fig. 7. 3. Cut length of 200mm diameter pipe to suit chosen method of flue connection. Insert flue pipe spigot in stove outlet socket and caulk joint with soft rope and cement. 4. Connect flue pipe to chimney with selected method. Figs. 4a, 4b 5a and 5b. 5. Make connections to the boiler with provision for draining at the lowest point, fill with water and test. Make good any brickwork around pipes. COMMISSIONING 1a.Non-Boiler Model When lighting open both firedoors and place paper and sticks with a small quantity of fuel onto the bottomgrate. Ignite paper and set both ashpit door spinwheels fully open and lock both firedoors. 1b.Boiler Model Check that the system is full of water and free from air locks. When lighting, open both firedoors and place paper and sticks with a small quantity of fuel onto the bottomgrate. Ignite paper and set the thermostat knob to 8 (high) and lock both firedoors. When established, balance the water system. With the appliance under fire, check for soundness of seals/joints and that the flue functions correctly in permitting all smoke and fumes to be vented through the chimney. 5

GENERAL INFORMATION 1. Bottomgrate bars - there are nine grate bars of one type and ten of another. The ten bars occupy the ends and the intermediate positions. The nine bars fit between these. See that they are properly placed on the cross front firebar and move freely when riddled. 2. If the thermostat has been removed for any reason, refer to the thermostat adjustment or replacement instructions. Flue Pipe 200mm diameter cast iron flue pipe and fittings in a matt black paint finish are available through your local stockist. Replacement parts if required are available through your local stockist. INSTRUCT USER After completing the installation, the Heating Contractor should demonstrate to the user, the operation of the fire, e.g. ashpit door spinwheel or thermostat setting, as appropriate, the method of riddling as well as the routine flue cleaning method. Ensure the installation and operating instructions are left in the possession of the user. BOILER MODEL Advise the user that under no circumstances must the appliance be fired dry as damage will occur. Advise the User of the precautions necessary to prevent damage to the heating system and to the building in the event of the heating system remaining inoperative during frost conditions. Models Non-boiler Boiler Weight of complete stove 241Kg 301 Kg 6

7

For further advice or information contact your local distributor/stockist With Aga-Rayburn s policy of continuous product improvement, the Company reserves the right to change specifications and make modifications to the appliance described and illustrated at any time. Manufactured By Aga-Rayburn Station Road Ketley Telford Shropshire TF1 5AQ www.aga-rayburn.co.uk www.agacookshop.co.uk 8