Powr-Zone Ozone Generator

Similar documents
MATERIAL SAFETY DATA SHEETS. SECTION I Manufacturer/Distributor Telephone No.: (315)

Material Safety Data Sheet

Radiator Additive. ZetaLube. Description

Kent Reef Carbon Material Safety Data Sheet

Material Safety Data Sheet U.S. Department of Labor Occupational Safety and Health Administration

EMERGENCY PHONE: or (651) (24 hours)

This MSDS has been compiled in accordance with - EC Directive 91/155/EC - OSHA's Hazcom Standard (29 CFR )

EMERGENCY PHONE: or (651) (24 hours)

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET 3M Tapes: 3900, 3939, 6969, 2929, 5959, 8979, 8979N, and /19/13

EMERGENCY PHONE: or (651) (24 hours)

Material Safety Data Sheet SECTION 1: PRODUCT AND COMPANY IDENTIFICATION SECTION 2: INGREDIENTS SECTION 3: HAZARDS IDENTIFICATION

EMERGENCY PHONE: or (651) (24 hours)

Material Safety Data Sheet Masonite TM Hardboard

EMERGENCY PHONE: or (651) (24 hours)

EMERGENCY PHONE: or (651) (24 hours)

MATERIAL SAFETY DATA SHEET

3M MATERIAL SAFETY DATA SHEET 3M(TM) Micropore(TM) Surgical Tape 1530, 1530S, 1530B, 153NS, /03/2006

AIR PURIFIER OZONE GENERATOR

Material Safety Data Sheet

EMERGENCY PHONE: or (651) (24 hours)

MATERIAL SAFETY DATA SHEET

EMERGENCY PHONE: or (651) (24 hours) Ingredient C.A.S. No. % by Wt POLYPROPYLENE

EMERGENCY PHONE: or (651) (24 hours)

MATERIAL SAFETY DATA SHEET 3M Micropore Surgical Tape 1530, 1530S, 1530B, 153NS, /24/12

3M MATERIAL SAFETY DATA SHEET 3M(TM) Transpore(TM) Surgical Tape Cat. # 1527 series, 1527S-1, 1527S-2 04/07/2006

Facility Safety Rules Hazard Communication Emergency Procedures Fire Safety. Safety Orientation

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET 3M Earloop Fluid Resistant Face Mask Cat. # 1820, 1820FS 09/18/12

EMERGENCY PHONE: or (651) (24 hours)

MATERIAL SAFETY DATA SHEET 3M Single Coated Medical Plastic Tape 1527L, 1527LX, 1527SP and 1527ENP 02/21/11

3M MATERIAL SAFETY DATA SHEET 3M(TM) Durapore(TM) Surgical Tapes Cat. #1538 and 1538S series 02/27/2006

Safety Data Sheet 1. PRODUCT AND COMPANY IDENTIFICATION. Product name: Product Number:

Certificate of Compliance Section 1 - PRODUCT AND COMPANY IDENTIFICATION

Diffusion Dryer Model 250

SAFETY DATA SHEET. FILE NO.001 NAME OF PRODUCT MSDS DATE: 02/12/2016 CATCHMASTER Brand Adhesive Devices

Material Safety Data Sheet

DR Series. Installation & Operations Manual. Model: DR-10 HIGH OUTPUT SHOCK TREATMENT OZONE GENERATOR

Certificate of Compliance Section 1 - PRODUCT AND COMPANY IDENTIFICATION

MATERIAL SAFETY DATA SHEET 3M Durapore Surgical Tapes Cat. # L (with liner) and 1538S series 02/03/12

Certificate of Compliance

Certificate of Compliance. 1.2 ITEM NUMBER AND SIZES: ml, ml, ml, ml

EMERGENCY PHONE: or (651) (24 hours)

MATERIAL SAFETY DATA SHEET

TG-10 Wall Mount Installation and Operation Manual. High Output Ozone Generator

Model LA-2SP. Air Purification Unit. User Guide. Bring Freshness Indoors

MATERIAL SAFETY DATA SHEET

Material Safety Data Sheet

Air Purification Unit MODEL 300/RHO2 USER GUIDE. Because You Care, Clean the Air

BETACURE 100 CO-REACTANT

Certificate of Compliance

Electric Garage Heater

CLEANING AND SANITIZING

Revision date: 22/4/2016 Date of print: 11/5/2016 Version: 1 Language: en-ca,us Page: 1 of 8

SECTION 1: PRODUCT AND COMPANY IDENTIFICATION

GASBLASTER LSX4 OPERATION MANUAL

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE

AH-600 Baseboard Heater

PRODUCT SAFETY DATA SHEET

PARABOND DETACH II Adhesive Remover

IMPORTANT INSTRUCTIONS READ & SAVE

SAFETY DATA SHEET. FILE NO.001 NAME OF PRODUCT MSDS DATE: 11/06/14 CATCHMASTER Brand Adhesive Devices. Peanut Butter Mouse Size Glue Boards

3.1. Substances Not applicable 3.2. Mixtures Name Product identifier % GHS-CAN Classification GHS-US classification

SECTION 1: PRODUCT AND COMPANY IDENTIFICATION

HSI Fire and Safety Group, LLC 107 Garlisch Drive Elk Grove Village, IL

Emergency Telephone Number Emergency Number : CHEMTREC / CANUTEC

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

register your product at a2zozone.com/pages/warranty Air-7000 & Air-3500 Operating Manual

Material Safety Data Sheet according to Regulation (EC) No. 1907/2006. Composition/Information on Ingredients

MATERIAL SAFETY DATA SHEET

INTERNATIONAL OZONE TECHNOLOGIES GROUP, INC.

MATERIAL SAFETY DATA SHEET

Material Safety Data Sheet

EL195DFE SERIES GAS FURNACE WARNING

1. Chemical Product and Company Identification

Low Profile. Baseboard Heater

MATERIAL SAFETY DATA SHEET

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

1 Easton Oval Poison Control Center. For additional health, safety or regulatory information, call

All Natural Odor Control Without Sprays. Odor Absorbing Pouches Work Quickly To Purify The Air! Professional Products. Homes Buildings Vehicles

EL195UH SERIES GAS FURNACE WARNING

G61MPV SERIES GAS FURNACE WARNING

THANK YOU FOR PURCHASING THE LV-H133 TOWER HEPA AIR PURIFIER BY LEVOIT! GET STYLE #LevoitLove #LevoitLifestyle

U.S. Consumer Product Safety Commission Washington, DC 20207

FILE NO.001 NAME OF PRODUCT MSDS DATE: 01/01/2018

MSDS for TECH-G (PETG) taulman3d,llc St Louis, MO. taulman3d,llc

Commercial Dryer/Air Mover

Response to Carbon Monoxide Incidents. W.J. Streett Jr Training Section Chief

Hardwired Electric Garage Heater

ICE BANK DESCALER & ICE MACHINE CLEANER

IMPORTANT INSTRUCTIONS READ & SAVE

Paper Tape Safety Data Sheet*

11/22/2013. Where are we now? How did we get here? MSDS Sheets. CA MSDS Standard. Right To Know. Director s List. T8 CCR 5194 Hazard Communication

POLAR BREEZE Statim Technologies, LLC IMPORTANT SAFETY INSTRUCTIONS AND PRECAUTIONS

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/25/2014 Revised On 09/25/2014

HEALTH. Particles. Chemicals

IMPORTANT INSTRUCTIONS READ & SAVE

HEALTH. Particles. Chemicals

YOUR PORTABLE AIR PURIFIER

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/26/2014 Revised On 09/26/2014

Transcription:

Powr-Zone Ozone Generator OPERATORS MANUAL AND PARTS LIST Model PFPZ 1.5 grams/hr., 7 p.p.m Effective for areas up to 60,000 cubic feet Gas filled arc module electrodes READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE WARNING: USE IN UNINHABITED AREAS ONLY. Ozone attacks organic matter. Limited exposure can cause nausea. Prolonged exposure, more than 48 hours, can be hazardous. Do not get machine wet. Consult MSDS sheet before use. WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT. X9234 10/2005

Powr-Zone Powr-Zone the Professional Odor Neutralizer Not a simple cover-up or ionizer, the Powr-Zone unit is an economical environmental odor neutralizer that actually destroys the source of the odor and leaves pure, fresh oxygen in its place. This large-capacity ozone generator is ideal for commercial use, eliminating odors in any indoor location and in vehicles. It is excellent for removing odors caused by smoke damage, mold, mildew, pets and other sources commonly encountered in building maintenance and refurbishing. Use the Powr-Zone unit in basements, kitchens, bathrooms, and any room with an odor problem. It also provides rapid deodorizing of hotel/motel rooms, meeting rooms and vehicles such as automobiles, buses, boats and aircraft. Your Powr-Zone is complete and ready to operate. SAFETY PRECAUTIONS Do not operate equipment before reading and understanding all instructions, procedures and warnings. Do not use this product near water or in a moist environment. Operate equipment only with the correct electrical power. Do not attempt to service this product yourself as opening or removing the enclosure may expose you to dangerous voltage or other hazards. Do not put foreign objects inside the equipment. Do not operate equipment with a damaged cord or plug, if fans fail to rotate, after the equipment malfunctions or if it has been dropped or damaged in any manner. Return equipment to manufacturer for examinations, electrical or mechanical adjustment or repair. Do not block air flow through equipment. Set equipment at least 6 inches form walls or any structure that could block the air intake. Do not use equipment in a flammable or explosive atmosphere. OZONE IS A POWERFUL OXIDIZER THAT REACTS WITH ORGANIC SUBSTANCES AND IS CLASSIFIED BY OSHA AND EPA AS AN UPPER RESPIRATORY IRRITANT. OSHA SETS THE ALLOWABLE EXPOSURE LIMITS AT.05 PPM TO.1 PPM. ALL SAFETY PRE- CAUTIONS HEREIN MUST BE ADHERED TO AND COMMON SENSE PRACTICED. The ozone produced by the Powr-Zone is above the allowable exposure limit as set by OSHA for inhabited areas. Therefore, no person or animal should remain in an area being treated by these units. The treated area should be aired out or given enough time for the ozone to dissipate to a level below.1 PPM before people or animals are allowed to re-enter. Ozone has an average halflife of 20 minutes, so one hour should be sufficient time for an un-vented room to return to normal. If ozone odors are noticeable and irritating, the area should be vented longer until the level is reduced. The average person can detect ozone at levels as low as.003 PPM. Symptoms of prolonged or excessive exposure to ozone are: burning, watery or irritated eyes, nose, and throat, nausea, headache, difficult in breathing, dry cough, irritation to nasal passages, throat, bronchial and pulmonary membranes. Caution: Prolonged exposure can also affect certain organic materials such as rubber, plastic, wire insulation. Only qualified personnel should operate the Powr-Zone ozone generator. As with all electrical devices this equipment should not be operated in a wet or damp environment. This equipment should only be operated using a properly grounded electrical outlet. All precautions must be taken to prevent over exposure of ozone gas to occupied areas. Do not disassemble your Powr-Zone equipment, there are no user serviceable items inside and this will also void the warranty. Powr-Flite assumes no liability for damages or injuries incurred by the misuse of this equipment. Save These Instructions

Powr-Zone GENERAL INSTRUCTIONS Prior to using the Powr-Zone ozone generator, determine the source of the odor and remove any odor causing substance that can be found. If the odor is from a wet or flooded situation, dry the entire area well before starting the ozonation procedure. 1. Make certain all people, pets and plants are out of the area. Close all windows and doors. Place a safety sign on the door to the location warning of Ozone use DO NOT ENTER. 2. Place the Powr-Zone unit on a shelf or tabletop as high in the area to be treated and if possible, near the AC return. NOTE: Ozone is heavier than air and will fall to the bottom of the room. For best results place an air mover at a 45 degree angle, pointed towards the wall to create a circular air movement. 3. Set the air conditioning thermostat on constant fan and adjust the temperature control to a low (cold) setting. If AC is not available, use air movers for more effective treatment. NOTE: Ozone generators work best in a cool, low humidity environment. With the AC on, you also receive a secondary benefit of purifying the inside of the ductwork. This is also true for ozoning automobiles. Smoke and stale odors will stay in a car s AC ducts if you do not run the AC during ozoning. 4. Plug the power cord into a grounded, 3-prong outlet. 5. To set the timer, turn the dial to 12 and then back to desired length of time. 6. Leave the area immediately. Do not return until set time plus 20 minutes has expired. 7. After time has expired, open all windows or doors to air out for 20 minutes. To calculate the time to remove the odor or to purify an area: (x cubic feet 100 CFM) x 2 = time setting example: (1000 cubic foot room 100) x 2 = time setting 10 x 2 = time setting 20 minutes = time setting NOTE: Ozone destroys odor-causing molecules. The length of time this process takes will vary depending on variables such as pollutant load, temperature, humidity, etc. and the amount of area being treated. The ozone process can produce a haze in the air within the area being treated. CAUTION DO NOT BREATHE HIGH LEVELS OF OZONE. OZONE IN CONCENTRATIONS ABOVE 0.04 PPM IS CLASSIFIED AS AN UPPER RESPIRATOR IRRITANT AND MAY BE CONSIDERED UNHEALTHY IN OCCUPIED AREAS. THIS MODEL OZONE GENERATOR IS INTENDED FOR USE IN UNOCCUPIED AREAS ONLY. THIS OZONE GENERATOR SHOULD BE TIMED TO TURN OFF AT LEAST 20 MINUTES PRIOR TO REENTRY OF TREATED AREA. TREATED AREA SHOULD BE AIRED OUT PRIOR TO REENTERING TO PREVENT EXPOSURE TO HIGH LEVELS OF OZONE. TROUBLESHOOTING Problem Possible Cause Solution Unit does not turn on Power cord not plugged in. Plug power cord into suitable outlet with correct voltage. Circuit breaker is tripped. Faulty power outlet. Fuse is blown on back of unit Reset circuit breaker at panel box. Try another outlet. Replace fuse. Unit keeps blowing Too small amperage fuse is Replace fuse with correct rated (1A) fuse. Fuses. being used Electrical short circuit. Return unit to manufacturer for repair. Unit does not Damage to unit. Return unit to manufacturer for repair. produce ozone. Save These Instructions

MATERIAL SAFETY DATA SHEET (MSDS) 24 HOUR EMERGENCY PHONE: 1-800-424-9300 Name: OZONE Product: Triatomic Oxygen Issued: 12/01/00 SECTION 1 - IDENTIFICATION Chemical Name: Triatomic Oxygen Chemical Family: Gas DOT Hazard Class: DOT Identification: SECTION 2- HAZARDOUS INFORMATION Component CAS # % PEL TLV Ozone Gas 10028-15-6 0.1ppm SECTION 3- PHYSICAL DATA Appearance and Odor: Colorless gas, pungent odor. Minimum detectable odor at 0.02 ppm. Boiling Point: 112 C Vapor Pressure: Vapor Density (air +1): Solubility,v in Water: Specific Gravity (H20 = 1): 1.6 g/l (liquid) Melting Point: 192 C Evaporation Rate (H20=1): SECTION 4 - FIRE & EXPLOSION DATA Not flammable, but enhances combustion of other substances to cause fire or explosion. Flash Point: Flammable Limits: LEL: UEL: Fire Extinguishing Media: Use the extinguisher appropriate to burning material. Special Firefighting Procedures: None Unusual Fire Hazards: Increased oxygen can feed fire. Explosion Hazards: None SECTION 5 - REACTIVITY DATA Stability: Unstable. Begins to dissipate immediately. Conditions to Avoid: Incompatibility: High levels for extended periods will cause deterioration of rubbers, paint and metal. Hazardous Decomposition: Hazardous Polymerization: None Disclaimer: The information in this document applies to workplace exposure and is not designed for the population at large. Any generalization beyond occupational exposures should not be made. A Tacony Company 3101 Wichita Court Ft. Worth, TX 76140-1755 SECTION 6 - HEALTH HAZARD DATA Health Hazards: Irritation of the eyes and respiratory tract. Inhalation of the gas may cause lung edema or asthmatic reactions. Symptoms may not become noticeable for several hours. Lungs may be affected by repeat or prolonged exposure. Carcinogenicity: None known. Medical Conditions Aggravated by Exposure: Methods of Exposure: Inhalation and contact on skin and eyes. Symptoms of Exposure: Cough, dry throat, irritated eyes, headache. Possible asthma-like symptoms with overexposure. EMERGENCY FIRST AID: Eye and Skin: Inhalation: Ingestion: Move to fresh air. Move to fresh air. Seek medical attention if asthma-like symptoms are noticed. SECTION 7 - PRECAUTIONS FOR SAFE HANDLING & USE Storage and Handling: Spill Response: Waste Disposal: Other Precautions: EPA Recommended Exposure Limits: 0.1 ppm / 8 hrs or maximum 0.3 ppm for 10 mins. NOTE: Threshold limit values refer to airborne concentrations of ozone and represent conditions under which it is believed that nearly all workers may repeatedly be exposed day after day without adverse effect, however a small percentage of workers may experience discomfort at levels below those listed. SECTION 8 - CONTROL MEASURES This gas is designed to be used for a limited time in a controlled environment. Eye Protection: Ventilation: Respiratory Protection: Protective Clothing or Other Equipment: Work/Hygienic Practices: None When treatment is complete, ventilate the area completely until all smell of ozone is gone. Do not allow people or pets into the area until the ozone smell is eliminated. Do not use in inhabited spaces. Clear all people, animals, plants and any other organic life from the area to be treated. None Not Available at Date Issued NFPA HAZARD RATING 4 = EXTREME 3 = HIGH 2 = MODERATE 1 = SLIGHT 0 = INSIGNIFICANT

Powr-Zone ref # part no description 1 X9227 Housing 2 X9229 Kit, Component 2a X9248 Timer 2b X9247 Lamp, On/Off Indicator 2c X9246 Filter, Intake 2d X9249 Fuse Holder 2e X9228 Panel, Switch 2f X9242 Transformer 2g X9241 Ozone Tube w/ Cables 2h X9245 Grill, Fan ref # part no description 2j X9244 Fan 2k X9243 Bracket, Transformer 3 72387A Screw, #8 x 5/8, Black Tapping 4 PD3C Foot, Black Rubber 5 X9235 Label, Time Chart 6 X8459A Label, Serial Number 7 X9232 Label, Caution 8 X9231 Label, Instruction 9 X9230 Label, Powr-Zone Conditional Guarantee The manufacturer warrants that products manufactured are free from defects in material and workmanship under normal use and service for a period of one year from date of purchase provided such goods are installed, operated and maintained in accordance with written manuals and/or other instructions. We will repair or replace without cost, any part of the unit, which when examined by our authorized repair station or at our factory, is found to be legitimately defective. This guarantee is null and void on any part which has been subject to alteration, accident, abuse or misuse. The guarantee is valid only to the original using purchaser.

A Tacony Company 3101 Wichita Court Ft. Worth, TX 76140-1755