Next Generation Corona Discharge Auto Voltage Sensing Installation Manual

Similar documents
Ozone + UV Sanitation

MDV. Mixing Degas Vessel. For Spa Ozone Generators Installation & Operations Manual Rev.C

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

A2Z Ozone, Inc. PRODUCT MANUAL

DEL AOP 25 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

1, 2, & 4. Corona Discharge Ozone Generators INSTALLATION & OPERATION MANUAL. DEL Ozone SAN LUIS OBISPO, CA USA Fax:

Mixing Degas Vessel (MDV) EC-1, EC-2, EC-4, Total Eclipse 2 or 4, and TrioPure-25 or TrioPure-50

ZO-400 & ZO Installation & Operations Manual

Next Generation Corona Discharge Next Generation Corona Discharge Nueva generación Corona de descarga

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

OZONE SYSTEM FOR IN-GROUND POOLS UP TO 18,000 GALLONS

Ozone plus UV Sanitation System Installation & Operations Manual

AIR OZONE GENERATOR MANUAL MODEL AIR /240V 50/60HZ

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

register your product at a2zozone.com/pages/warranty Air-7000 & Air-3500 Operating Manual

Ozone plus UV Sanitation System Installation & Operations Manual

Installation Guide. Manufactured for Aero-Spa, LLC Web:

ion Genesis Pump Controller

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

INSTALLATION MANUAL. PP1 Ozone System Designed for use within pool skimmer

Next Generation Corona Discharge Installation & Operation Manual

INSTALLATION, OPERATION AND MAINTENANCE

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Ella Gel Coat Walk In Tub E SERIES OWNER'S MANUAL

Air Pump Up to 800 gallons

INSTALLATION MANUAL. PP2 Ozone System (No Filter Cartridge) PP3 Ozone System (With Filter Cartridge) nspdevelopment.com

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Prime Tower. Inline Chiller. Instructions for Models #2645,2646

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

O w n e r s M a n u a l

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

register your product at a2zozone.com/pages/warranty MP Series Operating Manual


Prime Chiller Mini-Chillers

Quest Power Electric Heat EHS 62 Pro

InstructIon Manual KrEs EQuIPMEnt stands

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

Professional Warming Drawer and Warming Drawer Cabinet

Phoenix AirMAX - Radial Air Mover

gamma pond Ultraviolet Sterilizers

Spa Control System OWNER S MANUAL

EcoMaster - Residential Pools up to 40,000 Gallons

Multiple Boilers Electro TS Series Application EB-C-STG5

EcoMaster - Residential Pools up to 40,000 Gallons

OWNER S MANUAL. Installation Operation Maintenance. Saturn Equipment

Quest Dry 105, 155, and 205 Dual

Quest Power Electric Heat EHS 31 Pro

Prime chiller. Inline Chiller. Instructions for Models #2645,2646

Owner s Manual Phoenix FireBird

OmniDry 2.9 Amp Centrifugal Air Mover

Cleanshield HEPA 550 Owner's Manual

Thermostat Remote Control & Receiver

OZX-300ST Ozone Generator

4000IS PROFESSIONAL IRONING SYSTEM INSTRUCTION MANUAL

QUICK PRIME INSTALLATION AND SERVICE MANUAL

TrueClean ToteCleaner

SUNCOURT RADON FAN MODEL: RDN04 & RDN04-3, RDK04 & RDK04-3 INSTALLATION INSTRUCTIONS

Owner s Manual Hydro-X Vacuum Pac

IW-25-2 Dehumidifier Installation & Operations. Manual

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

1 HP Air Mover. Owner s Manual

Drain Tempering Reservoir READ & SAVE THESE INSTRUCTIONS. Installation, Operation, & Maintenance. TRION

O w n e r s M a n u a l

BOUNCY CASTLE Model # INF-2003 Item #

Towel Warmer. Luxurious warmth for towels, robes and blankets

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Installation Instructions PP-AS20 Anti-Scale System

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

(The chances are you re never going to read me) Owner s Manual.

Towel Warmer MAKE EVERYDAY A SPA DAY

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

Whole House Filter Model: WH-LD

INSTRUCTION MANUAL HS-229G

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

Instruction Manual for the Chefmate Countertop Soup Warmer Model CPSKB1

Prime Chiller 1/10th HP Chiller

MIXERS SMX10-1, SMX20-1, SMX20-2, SMX30-1 INSTRUCTION MANUAL

(The chances are you re never going to read me) Owner s Manual HEAVY DUTY SHD-1T.

HANDY/STICK 2-WAY VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H055

Xaact Spot. Xaact Hot Spot

MN908 No. 282C Replaces 282B LB7013

Instruction Manual for the Globe Mixer. Model SP8-RL

To make planning your kitchen even easier, IKEA has developed a complete line of high quality major appliances that are designed for everyday use and

Auto/Air Power Adapter for Dell Quick Installation Guide

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL

GETZ MANUFACTURING PART # CYLINDER DRYER

MaxLite LED Round Pendant Highbay Series

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

HotPoly Tote Tank / IBC Heaters (TTH Series)

Because you re not like everyone else. MISTING FAN MF26B OWNER S MANUAL

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

READ AND SAVE THESE INSTRUCTIONS. Vacuum Food Storage System Reference Guide. Space Saving Design.

1500W STOVE HEATER INSTRUCTION MANUAL. Item No: 050-HA-50090

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Industrial Vacuums, Inc

Transcription:

Next Generation Corona Discharge Auto Voltage Sensing Installation Manual 4-2122-01 Rev.B

IMPORTANT SAFETY INSTRUCTIONS When installing and operating the Spa Eclipse ozone generator, basic precautions should always be followed: READ AND FOLLOW ALL INSTRUCTIONS Read this manual completely before attempting installation. All permanent electrical connections should be made by a qualified electrician. Follow all applicable electrical codes. Be sure the electrical power is shut OFF at the main circuit breaker before installing the Spa Eclipse. If the Spa Eclipse electrical connection is to be attached to the spa controls, be sure the spa controls are protected by a Ground Fault Circuit Interrupter (G.F.C.I.). If the Spa Eclipse is connected to an independent electrical supply, then a G.F.C.I. must be installed between the Spa Eclipse and the electrical supply. WARNING - To reduce the risk of electrical shock, if the power cord is damaged, replace the entire unit immediately. The Spa Eclipse must be mounted indoors or sheltered, under a cover, from natural elements (rain, sun, sprinklers). Mount the Spa Eclipse so that it is inaccessible to anyone in the spa. Install a check valve in the tubing between the Spa Eclipse and the vacuum source. Plastic ozone supply tubing is available with the Spa Eclipse. Never replace this tubing with metal tubing. Do not operate the Spa Eclipse unless sufficient air flow is being drawn through the unit. WARNING: Short term inhalation of high concentrations of ozone and long term inhalations of low concentrations of ozone can cause harmful physiological effects. Do not inhale ozone gas produced by this device. SAVE THESE INSTRUCTIONS!

TABLE OF CONTENTS Installation Instructions 1. Mounting... 1 2. Plumbing - DEL Mixing System... 1 3. Plumbing - Ozone Generator... 1 4. Electrical... 2 5. Operation... 2 6. System Maintenance... 2 Figure 1: Spa Eclipse Mounting & Connections... 3 Figure 2: DEL Optimized Mixing System... 3 Warranty... 4 Installation Instructions 1. Mounting a. The Spa Eclipse must be mounted horizontally with ozone tubing connection pointing down. Use both mounting flanges. b. Mount as high as possible within the protected equipment area. 2. Plumbing - DEL Mixing System a. For optimal dissolution of ozone into the water, install the DEL Mixing System in the water circulation line as generally shown in Figure 2. b. For other circulation systems or vacuum sources, DEL Industries provides a wide range of installation kits. Contact DEL Customer Service for assistance. 3. Plumbing - Ozone Generator a. Connect ozone compatible tubing (1/4 internal diameter) to the open hose barb on the Spa Eclipse. b. Run tubing to the ozone injector or appropriate vacuum source. i. If the ozone generator is mounted above the water line, tubing may be run directly to the vacuum source. ii. If ozone generator is mounted below the water line, run tubing to a point above the water line and back down to the vacuum source. 1

c. Install the check valve in the tubing above the water line. Ensure flow direction is from the Spa Eclipse to the vacuum source. d. Secure all tubing connections with hose clamps. 4. Electrical a. Verify that there is no power to the spa and connect the Spa Eclipse cord into the mating connector(s) on the spa control box. b. Where possible, route the Spa Eclipse power cord away from other electrical lines. Avoid routing the power cord parallel to any low-voltage signal wires. 5. Operation a. With the spa filled to the proper level, run the spa controller through several cycles. i. Verify that the green light on the Spa Eclipse turns on and off as required by the controller. ii. Verify that gas is flowing into the injector (there should be no water in the tubing and very small bubbles at the return). iii. Verify that water does not push past the check valve during any spa cycle. iv. Check for and correct any leaks in the ozone tubing. 6. System Maintenance a. Ordering Information: To locate the dealer nearest you call 1.800.676.1335 ext. 232 Be prepared with the following information: Name Date Purchased Address Dealer Name Model # b. Standard Replacement Parts List: i. Ozone Check Valve...7-1140-01 ii. Ozone Tubing...7-0075 iii. Inlet Filter Assembly...9-0858-01 The Ozone Check Valve (Item i) should be replaced annually. c. Regularly inspect ozone supply tubing for cracks or wear. Also check to make sure no water is present between the 2

Check Valve and the Ozone Generator. This indicates Check Valve failure. Replace the Ozone Check Valve and tubing immediately.** d. Regularly inspect the inlet filter for dirt build-up. If the cotton filter element is clogged, remove the filter assembly and clean the filter or replace the filter assembly. **WARNING: Trace amounts of nitric acid may be present in the check valve or tubing and could be mildly corrosive. If condensation is present shut off the ozone generator and allow the moisture to be drawn out or dried up prior to servicing. Figure 1: Spa Eclipse Mounting & Connections Mounting Flange Mounting Flange Tubing Connection 1/4 ID tubing Figure 2: DEL Optimized Mixing System Check Valve Spa Eclipse Ozone Generator Ozone Flow Spa Controller/ Heater Inlet Filter Assembly Return Fitting Injector MTM Nozzle LGM Mixer Pump 3

DEL OZONE LIMITED ONE YEAR WARRANTY The limited warranty set forth below applies to products manufactured by DEL OZONE and sold by DEL OZONE or its authorized dealers. This limited warranty is given only to the first retail purchaser of such products and is not transferable to any subsequent owners or purchasers of such products. DEL Ozone warrants that it or its authorized dealers will repair or replace, at its option, any part of such products proven to be defective in materials or workmanship within ONE (1) year from the date of retail purchase of such products. (All parts) ANY REPAIR OR REPLACEMENT WILL BE WARRANTED ONLY FOR THE BALANCE OF THE ORIGINAL WARRANTY PERIOD OR NINETY (90) DAYS, Whichever is greater. NOTE: USE ONLY DEL AUTHORIZED DEL REPLACEMENT PARTS. USE OF ANY OTHER PART(S) WILL VOID THIS WARRANTY. Any replaced parts must be returned to DEL OZONE for warranty evaluation. THIS LIMITED WARRANTY DOES NOT INCLUDE ANY OF THE FOLLOWING: (a) (b) (c) (d) (e) (f) Any labor charges for troubleshooting, removal, or installation of such parts. Any repair or replacement of such parts necessitated by faulty installation, improper maintenance, improper operation, misuse, abuse, negligence, accident, fire, flood, repair materials, and/or unauthorized accessories. Any such products installed without regard to required local codes and accepted trade practices. Damage to unit caused by water backflow. Any implied warranty of merchantability or implied warranty of fitness for particular purpose, and such warranties are hereby disclaimed. DEL Ozone shall not be liable under any circumstances for loss of use of such product, loss of profits, direct damages, indirect damages, consequential damages, and / or incidental damages. This warranty gives you specific legal rights. You may have other rights which vary from state to state. TO OBTAIN WARRANTY SERVICE: DEL OZONE Customer Service Number: (800) 676-1335 Fax Number: (805) 541-8459 E mail warrantysupport@delozone.com (residential) service@delozone.com (commercial) PROVIDE: 1. Customer name, mailing address, and telephone. 2. Installer/Mechanical Contractor or Dealer name. 3. Unit Part Number, Serial Number or Manufacture Date, and date of purchase. 4. The date of failure. 5. A description of the failure. After this information is provided, DEL Ozone may release a RETURN GOODS AUTHORIZATION (RGA) NUMBER. After receiving the RGA number the part in question must be returned to DEL Ozone, freight prepaid, with the RGA number clearly marked on the outside of the package. All preauthorized defective parts must be returned to DEL Ozone within thirty (30) days. Under no circumstances may any product be returned to DEL Ozone without prior authorization. Returns without the assigned RGA number on the outside of the package will be refused and shipped back to the sender at their expense. Upon receipt of preauthorized returned goods, DEL Ozone will repair or replace, at DEL Ozone s option, the defective product(s) and return them (freight prepaid for products under warranty). Buyer s acceptance of the product and use thereof constitutes acceptance of these terms. 4-1353-01_Rev.E 4

PAGE INTENTIONALLY LEFT BLANK 5

EPA Estab. No. 071472-CA-001 800.676.1335 o3info@delozone.com www.delozone.com