CERTIFICATE of Product Conformity (QAL1 )

Similar documents
CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

Certificate: _01 / 29 April 2014

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: _03. V-CEM5100 for waste gas velocity. TÜV Rheinland Energy GmbH

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1 )

Certificate: _02 / 9 September 2014

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 28 July 2016

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: ENDA-5000 with analysing module CMA-5800 for NOx. S0 2, CO, co2 and 02

Certificate: / 9 February 2011

Certificate: / 29 April 2014

Certificate: _01 / 20 August 2013

CERTIFICATE of Product Conformity (QAL1)

Certificate: / 9 September 2014

CERTIFICATE of Product Conformity (QAL1 )

Certificate: _02 / 22 March 2013

CERTIFICATE of Product Conformity (QAL1 )

Certificate: _01 / 2 February 2015

Certificate: _01 / 22 March 2013

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: _02

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19July2017. Köln, 17 August2012

Certificate: _01 / 22 March 2013

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE. about Product Conformity {QAL 1) Number of Certificate: _02

_03 / 28 July 2015

Certificate: / 29 April 2014

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

Certificate: / 29 April / /D1 of 07 July 2006 Addendum 936/ /C of 20 September 2013

Certificate: _01 / 19 August 2011

CONFIRMATION of Product Conformity (QAL1)

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE AR500 Open Path Monitor with ER120

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

HFID Heated Total Hydrocarbon Analyzer Module

Proforma for Surveillance of Recognized Environmental Laboratory under the Environment (Protection) Act, 1986

International comparison of validation methods for dust concentration measurement

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.

Test reports for the determination of B 10d values for emergency stop switches of families 800F, 800H, 800T and D7 of Rockwell Automation

Emissioni convogliate in atmosfera: Sistemi di monitoraggio in continuo delle emissioni SME

CALIDUS tm the Modular micro Gas Chromatograph

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

Mercury Vapor Monitor VM-3000

Product data sheet Palas Fidas 200 S

FIDAS FINE DUST MONITORING SYSTEMS

Notified Body No.: 0098

Advance Optima Module Magnos 17

Series 9000 Total Hydrocarbon Analyzer

PRODUCT CONFORMITY CERTIFICATE

continuous emissions monitoring Combustion & Environmental Monitoring

Complete Gas Analysis

EuroFID Gas Analyzers for Measurement of the Total Hydrocarbon Content

Spark Extinguishing Systems

CO2 Carbon Dioxide Sensor

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

FLAME AMPLIFIER MODULE 3001

VM-3000 Mercury Vapor Monitor

VM-3000 Mercury Vapor Monitor

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

MCS 4000 Control Panel

Installation Instructions for Honeywell ALL-SPEC Air Sampling Smoke Detection System

Rotary Evaporators designed

OPTIBAR DP 7060 Supplementary Instructions

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Automation, Software und Informationstechnologie

DP 300 mobile dew point instrument

Electromagnetic Compatibility of Alarm Systems

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

CERTIFICATE. Conformity of the Factory Production Control CPR TÜVRh

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

Constant climate chamber with ICH-compliant illumination

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

CEN standardization work on refrigerating systems, especially standard EN 378

Constant climate chamber with humidity

Transcription:

ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000050625 Certified AMS: Manufacturer: Test lnstitute: A02000-Fidas24 for TOC ABB Automation GmbH Stierstädter Str. 5 60488 Frankfuri/Main Germany TÜV Rheinland Energy GmbH This is to certify that the AMS has been tested and certified according to the standards EN 15267-1 (2009), EN 15267-2 (2009), EN 15267-3 (2007) and EN 14181 (2014) Certification is awarded in respect of the conditions stated in this certificate (this certificate contains 6 pages). Suitability Tested EN 15267 QALI Certified Regular Surveillance www.tuv.com ID 0000050625 Publication in the German Federal Gazette (BAnz.) of 14 March 2016 German Federal Environment Agency Dessau, 25 April 2016 aj 4/ 4`/ `-,.`/-, Dr. Marcel Langner Head of Section 114.1 This ceriificate will expire on: 13 March 2021 TÜV Rheinland Energy GmbH Cologne, 24 April 2016 ß L " f2 c). r ppa. Dr. Peter Wilbring / qall.de info@qal l.de page 1 of 6

Test report: 936/21228173/A dated 21 October 2015 Initial certification: 14 March 2016 Expiry date: 13 March 2021 Publication: BAnz AT 14.03.2016 B7, chapter I number 3.1, Approved application The tested AMS is suitable for use at combustion plants according to Directive 2010/75/EU, chapter III (13. BImSchV), at waste incineration plants according to Directive 2010/75/EU, chapter IV (17. BImSchV) and other plants requiring official approval. The tested ranges have been chosen with respect to the wide application range of the AMS. The suitability of the AMS for this application was assessed on the basis of a laboratory test and a three-month field test at a waste incineration plant. The AMS is approved for an ambient temperature range of +5 C to +45 C. The notification of suitability of the AMS, performance testing, and the uncertainty calculation have been effected on the basis of the regulations valid at the time of performance testing. As changes in legal regulations are possible, any potential user should ensure that this AMS is suitable for monitoring the limit value relevant to the application. Any potential user should ensure, in consultation with the manufacturer that this AMS is suitable for the installation at which it will be installed. Basis of the certification This certification is based on: test report 936/21228173/A of 21 October 2015 of TÜV Rheinland Energie und Umwelt GmbH suitability announced by the German Federal Environment Agency (UBA) as the relevant body the on-going surveillance of the product and the manufacturing process qal1.de info@qal1.de page 2 of 6

Publication in the German Federal Gazette: BAnz AT 14.03.2016 B7, chapter I number 3.1, Announcement by UBA from 18 February 2016: AMS designation: AO2000-Fidas24 for TOC Manufacturer: ABB Automation GmbH, Frankfurt/Main Field of application: For measurements at plants requiring official approval and plants of 27. BImSchV Measuring ranges during the performance test: Component Certification range Supplementary range Unit TOC 0-15 0-50 0-150 0-500 mg/m³ Software version: Fidas24: 3.4.2 Syscon: 5.1.4 Restrictions: None Notes: 1. The maintenance interval is four weeks. 2. The AMS is available with housing AO2020 (19 -housing for rack installation) and AO2040 (for wall installation). Test report: TÜV Rheinland Energie und Umwelt GmbH, Cologne Report No.: 936/21228173/A dated 21 October 2015 qal1.de info@qal1.de page 3 of 6

Certified product This certificate applies to automated measurement systems confirming to the following description: The AMS is a flame ionization detector (FID) designed to determine total organic carbon (TOC) in exhaust gases. The extractive AO2000-Fidas24 analyzer consists of the following components: - Analyzer AO2000-Fidas24 - heated sensor (180 C) incl. controller, ABB PFE 3 - heated measurement gas line (180 C), (max. 60 m) incl. controller, Teflon sample gas line For operation, combustion air with a TOC concentration of < 1 % of the measurement range is required. Fidas24 is an analyzer module which is fitted in a universal housing of type AO2000 from the Advance Optima Series. Display and control unit, evaluation unit, the analyzer module as well as the power supply are fitted in the housing. Additionally, there are analogue outputs and data ports. The AMS is available with housing AO2020 (19 -housing for rack installation) and AO2040 (for wall installation). General notes This certificate is based upon the equipment tested. The manufacturer is responsible for ensuring that on-going production complies with the requirements of the EN 15267. The manufacturer is required to maintain an approved quality management system controlling the manufacture of the certified product. Both the product and the quality management systems shall be subject to regular surveillance. If a product of the current production does not conform to the certified product, TÜV Rheinland Energy GmbH must be notified at the address given on page 1. A certification mark with an ID-Number that is specific to the certified product is presented on page 1 of this certificate. This can be applied to the product or used in publicity material for the certified product. This document as well as the certification mark remains property of TÜV Rheinland Energy GmbH. With revocation of the publication the certificate loses its validity. After the expiration of the certificate and on requests of the TÜV Rheinland Energy GmbH this document shall be returned and the certificate mark must not be employed anymore. The relevant version of this certificate and its expiration is also accessible on the internet: qal1.de. qal1.de info@qal1.de page 4 of 6

Certification of AO2000-Fidas24 for TOC is based on the documents listed below and the regular, continuous monitoring of the Quality Management System of the manufacturer: Initial certification according to EN 15267 Certificate No. 0000050625: 25 April 2016 Expiry date of the certificate: 13 March 2021 Test report: 936/21228173/A dated 21 October 2015 TÜV Rheinland Energie und Umwelt GmbH, Cologne Publication: BAnz AT 14.03.2016 B7, chapter I number 3.1 Announcement by UBA from 18 February 2016 qal1.de info@qal1.de page 5 of 6

Calculation of overall uncertainty according to EN 14181 and EN 15267-3 Measuring system Manufacturer ABB Automation GmbH AMS designation AO2000-Fidas24 Serial number of units under test 33481024 / 33481014 Measuring principle FID Test report Test laboratory Date of report 936/21228173/A TÜV Rheinland 2015-10-21 Measured component TOC Certification range 0-15 mg/m³ Evaluation of the cross-sensitivity (CS) (system with largest CS) Sum of positive CS at zero point 0.55 mg/m³ Sum of negative CS at zero point 0.00 mg/m³ Sum of postive CS at span point 0.32 mg/m³ Sum of negative CS at span point -0.49 mg/m³ Maximum sum of cross-sensitivities 0.55 mg/m³ Uncertainty of cross-sensitivity u i 0.320 mg/m³ Calculation of the combined standard uncertainty Tested parameter u² Standard deviation from paired measurements under field conditions * u D 0.048 mg/m³ 0.002 (mg/m³)² Lack of fit u lof 0.041 mg/m³ 0.002 (mg/m³)² Zero drift from field test u d,z -0.225 mg/m³ 0.051 (mg/m³)² Span drift from field test u d,s 0.260 mg/m³ 0.068 (mg/m³)² Influence of ambient temperature at span u t 0.058 mg/m³ 0.003 (mg/m³)² Influence of supply voltage u v 0.040 mg/m³ 0.002 (mg/m³)² Cross-sensitivity (interference) u i 0.320 mg/m³ 0.102 (mg/m³)² Influence of sample gas flow u p 0.118 mg/m³ 0.014 (mg/m³)² Uncertainty of reference material at 70% of certification range u rm 0.121 mg/m³ 0.015 (mg/m³)² Variation of response factors (TOC) u rf 0.042 mg/m³ 0.002 (mg/m³)² * The larger value is used : "Repeatability standard deviation at set point" or "Standard deviation from paired measurements under field conditions" å ( ) Combined standard uncertainty (u C ) u c = u max, j 0.51 mg/m³ Total expanded uncertainty U = u c * k = u c * 1.96 1.00 mg/m³ 2 Relative total expanded uncertainty U in % of the ELV 10 mg/m³ 10.0 Requirement of 2010/75/EU U in % of the ELV 10 mg/m³ 30.0 Requirement of EN 15267-3 U in % of the ELV 10 mg/m³ 22.5 qal1.de info@qal1.de page 6 of 6