Dual Laser InfraRed (IR) Thermometer

Similar documents
Dual Laser InfraRed (IR) Thermometer

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

High Temperature InfraRed Thermometer with Laser Pointer

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

IRT2 Dual Laser IR Thermometer - User Guide

Manual PCE-889 pyrometer

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

User's Guide. Pinless Moisture Meter. Model MO257

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

R2310. Infrared Thermometer. Instruction Manual

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

CA876 INFRARED K-THERMOMETER WITH LASER ENGLISH. User Manual. Auto OFF

4-in-1 Humidity, Temperature Airflow and Light Meter

64 Max IR Thermometer

Visit us at testo 835 Infrared and contact thermometer

Users Manual. Visit us at

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

Precision Infrared Thermometer. Users Manual

I/R Thermometer Gun 12:1

IR D USB INFRA RED THERMOMETER

Manual Instructions IR Measuring Instrument GIM 1840 ST60 / ST80

64 Max IR Thermometer

Indoor/Outdoor Temperature Alert

USER MANUAL Digital CO Monitor Model CO30

MT4 MAX/MT4 MAX + Infrared Thermometer

User's Guide. Pinless Moisture Meter. Model MO257

Wet Bulb Thermo-Hygrometer Datalogger

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

62 MAX/62 MAX + Infrared Thermometer. Users Manual

User Guide. Moisture Meter. Model MO230

USER GUIDE Heat Index Psychrometer

62 MAX/62 MAX + Infrared Thermometer. Users Manual

Infrared Thermometer. Getting Started

562/563. Infrared Thermometers

62 MAX/62 MAX + Infrared Thermometer

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

Infrared Thermometer

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

62 MAX/62 MAX + Infrared Thermometer

Users Manual. Infrared Thermometer

USER GUIDE. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester. Model VFM200

NON-CONTACT VOLTAGE DETECTOR WITH ADJUSTABLE SENSITIVITY AND IR THERMOMETER USER S MANUAL

Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

62 MAX/62 MAX + Infrared Thermometer

Wide Temperature Range Low Cost Max Temperature Display Tripod Mountable Applications

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

Table of Contents Title Page Introduction Contacting Uni-Trend Safety Information Features Display Buttons and Connector How the Thermometer works.

Precision Infrared Thermometer. Users Manual

Instruments. for hydroponics & horticulture 2016

User's Guide. CO 2 Monitor. Model CO200

Self-Leveling Five-Beam Laser Pointer Model No Instruction Manual

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

Infrared Temperature Sensor

USER MANUAL USB Multi-Function Datalogger Model RHT35

OMEGA. OS643E-LS/OS643E Infrared Thermometer With Laser Sighting

Mobile solutions for extreme tasks. Ex-MX2

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

OMEGA (MODEL:610LF) OS642F-LS Infrared Thermometer With Laser Marker

Innovative Technology for Traditional and Challenging Applications

Instruction Manual. Model No and Self-Leveling Cross-Line Laser Level

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

SS-100. Pyrometer. Temperature Range: 800~2400

INSTRUCTION MANUAL ROTARY LASER LEVEL GPR-R40H / G40

Version 2.0. Operating Instructions HYDROMETTE BL COMPACT TF-IR. Hydromette BL Compact TF

100 Ft. LASER DISTANCE METER

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

RS Pro Infrared Temperature Sensor

Motorised Infrared Optical Beam Smoke Detector. User Guide

u Do not use the appliance if any part is damaged or defective. u Do not short battery terminals. u Do not charge batteries.

Apollo Intelligent Auto Aligning Beam Detector. User Guide

Motorised Infrared Optical Beam Smoke Detector. User Guide

Instruction Manual. Self-Leveling Rotary Laser Level Model Nos and

4-IN-1 PIN/PAD RH MOISTURE METER

User Manual. Humidity-Temperature Chart Recorder. Model RH520

FIRERAY 5000 range USER GUIDE

Class 1 laser beam sensor safe for your eyes

LD200 / RLD400 LD200-G /RLD400-G

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

QUICK START. FLIR Model MR59. Ball Probe Moisture Meter with Bluetooth

Class 1 laser beam sensor safe for your eyes

M15-GSL12P30 M15-GSL12P30S Heat Spy Infrared Thermometer User Manual

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

Infrared Moisture Balance (FD-660)

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

User Manual. Non-contact Infrared Thermometer.

CALIBRATABLE 3-FUNCTION THERMO- HYGROMETER USER S MANUAL

Class 1 laser beam sensor safe for your eyes

Transcription:

User Manual Dual Laser InfraRed (IR) Thermometer MODEL 42512

Introduction Congratulations on your purchase of the Model 42512 IR Thermometer. This Infrared thermometer measures and displays non-contact temperature readings up to 1832 o F (1000 o C). At 30, built-in dual lasers converge to 1 target spot to insure accurate targeting and temperature measurement. The adjustable emissivity feature allows the IR thermometer to measure the temperature of virtually any surface. Proper use and care of this meter will provide years of reliable service. Safety Use extreme caution when the laser pointer is on Do not point the beam toward anyone's eye or allow the beam to strike the eye from a reflective surface Do not use the laser near explosive gases or in other potentially explosive areas 2

Meter Description 1. Dual Laser pointers 2. LCD Display 3. Function Buttons 4. Measurement Trigger 5. Battery and F/C Switch compartment DISPLAY 1. SCAN, measurement in progress 2. HOLD, last measurement locked in display 3. Laser pointer active 4. Power locked ON 5. High limit alarm 6. Low limit alarm 7. C or F temperature units 8. Main temperature display 9. Low battery icon 10. MAX icon 11. Emissivity setting 12. Emissivity icon 13. Max temperature display 3

Operating Instructions Temperature Measurements 1. Hold the meter by its handle and point it toward the surface to be measured. 2. Pull and hold the trigger to turn the meter on and begin testing. The temperature reading, MAX temperature reading, the SCAN icon, the emissivity value, and the unit of measure will appear. 3. Release the Trigger and the reading will hold for approximately 7 seconds (HOLD will appear on the LCD) after which the meter will automatically shut off. The only exception to this is if the LOCK mode is set to ON. Note: Select the temperature units (ºF/ºC) using the switch inside the battery compartment Dual Laser Pointer The dual laser pointers are designed to cross at a distance of 75cm. The spot size at this distance is a 2.5cm diameter and this is the recommended distance to target for most measurements. To turn the lasers on/off: 1. Press and release the Trigger 2. While HOLD is on the display, press the laser button once to turn on the lasers on or off. 3. The laser icon will appear in the LCD when the laser function is enabled. 4. The status of the laser will be stored in memory and will remain as the turn-on condition until changed. 4

MAX (maximum) temperature display The highest reading encountered during a single measurement scan is displayed in the MAX display Backlight 1. Press and release the Trigger 2. While HOLD is on the display, press the backlight button once to turn on the backlight on or off. 3. The backlight will illuminate in the LCD when the feature is enabled. 4. The status of the backlight will be stored in memory and will remain as the turn-on condition until changed. 5. Note: The backlight will shorten the battery life. Only use this feature when required. The MODE button options The MODE button is used to access the Emissivity, Lock, High alarm and Low alarm features of the instrument. 1. Press and release the Trigger 2. While HOLD is on the display, press the MODE button to step through and program the following features. A blinking icon indicates the feature is selected. E= (Emissivity Value) Press the or buttons to change the emissivity value. (Lock mode On/Off) Press the or buttons to turn the lock feature ON or OFF. (High Alarm On/Off) Press the or buttons to turn the High Alarm feature ON or OFF. (High Alarm setting) Press the or buttons to set the high alarm limit value in the main display (Low Alarm On/Off) Press the or buttons to turn the High Alarm feature ON or OFF. (Low Alarm setting) Press the or buttons to set the Low alarm limit value in the main display. 5

High and Low Alarm Feature The meter has a programmable high and low alarm feature. When either alarm point is reached the meter will alert the user via an audible beep and a blinking LCD display icon. The alarm limit is set and the feature is enabled/disabled using the MODE button. The setting is stored and memory and will remain as the turn-on condition until changed. Temperature Units The temperature units can be set to F or C using the switch located in the battery compartment. Lock feature The LOCK feature disables the Auto Power Off feature for the period of use when selected. The feature is useful for long term temperature monitoring and hands free use. The meter will revert to auto power off if the trigger is pressed during a locked scan. Over-range Indication If the temperature measurement exceeds the specified temperature range, the thermometer will display dashes in place of a temperature reading. Battery Replacement When the low battery symbol appears on the display, replace the meter s battery (9V). The battery compartment is located behind the panel that surrounds the meter s trigger. Open the compartment by pulling the panel down from the trigger area. Replace the 9V battery and close the battery compartment cover. You, as the end user, are legally bound (Battery ordinance) to return all used batteries and accumulators; disposal in the household garbage is prohibited! You can hand over your used batteries / accumulators at collection points in your community or wherever batteries / accumulators are sold! Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle 6

IR Measurement Notes 1. The object under test should be larger than the spot (target) size calculated by the field of view diagram (printed on the side of the meter and in this guide). 2. Before measuring, be sure to clean surfaces that are covered with frost, oil, grime, etc. 3. If an object's surface is highly reflective, apply masking tape or flat black paint to the surface before measuring. Allow time for the paint or tape to adjust to the temperature of the surface it is covering. 4. Measurements through transparent surfaces such as glass may not be accurate. 5. Steam, dust, smoke, etc. can obscure measurements. 6. The meter automatically compensates for deviations in ambient temperature. However, it can take up to 30 minutes for the meter to adjust to extremely wide changes. 7. To find a hot spot, aim the meter outside the area of interest then scan across (in an up and down or side to side motion) until the hot spot is located. Field of View The meter s field of view is 30:1. For example, if the meter is 75cm from the target (spot), the diameter of the target must be greater than 2.5cm. Other distances are shown in the field of view diagram. Measurements should normally be made as close as possible to the device under test. The meter can measure from moderate distances but the measurement may be affected by external sources of light. In addition, the spot size may be so large that it encompasses surface areas not intended to be measured. 7

Emissivity and IR Measurement Theory IR Thermometers measure the surface temperature of an object. The thermometer s optics sense emitted, reflected, and transmitted energy. The thermometer s electronics translate the information into a temperature reading which is then displayed on the LCD. The amount of IR energy emitted by an object is proportional to an object's temperature and its ability to emit energy. This ability is known as emissivity and is based upon the material of the object and its surface finish. Emissivity values range from 0.1 for a very reflective object to 1.00 for a flat black finish. For the Model 42515, the emissivity is adjustable from 0.1 to 1.00. Most organic materials and painted or oxidized surfaces have an emissivity factor of 0.95. When in doubt, set the emissivity to 0.95. Emissivity Factors for Common Materials Material under test Emissivity Material under test Emissivity Asphalt 0.90 to 0.98 Cloth (black) 0.98 Concrete 0.94 Skin (human) 0.98 Cement 0.96 Leather 0.75 to 0.80 Sand 0.90 Charcoal (powder) 0.96 Soil 0.92 to 0.96 Lacquer 0.80 to 0.95 Water 0.92 to 0.96 Lacquer (matt) 0.97 Ice 0.96 to 0.98 Rubber (black) 0.94 Snow 0.83 Plastic 0.85 to 0.95 Glass 0.90 to 0.95 Timber 0.90 Ceramic 0.90 to 0.94 Paper 0.70 to 0.94 Marble 0.94 Chromium Oxides 0.81 Plaster 0.80 to 0.90 Copper Oxides 0.78 Mortar 0.89 to 0.91 Iron Oxides 0.78 to 0.82 Brick 0.93 to 0.96 Textiles 0.90 8

Specifications Range -50 to 1000 o C (-58 to 1832 o F) Resolution 0.1 o < 1000 o, 1 o > 1000 o Accuracy -50 C to -23 C (-58 F to -10 F) ±7 C/14 F (Typical) -23 C to -2 C (-10 F to 28 F) ±4 C/8 F -2 C to 94 C (28 F to 200 F) ±2.5 C/4.5 F 94 C to 204 C (200 F to 400 F) ±(1.0%rdg + 1 C/2 F) 204 C to 426 C (400 F to 800 F) ±(1.5%rdg + 1 C/ 2 F) 426 C to 1000 C (800 F to 1832 F) ±(3%rdg +1 C/2 F) Note: Accuracy is specified for the following ambient temperature range: 23 to 25 C (73 to 77 F) Emissivity 0.10 to 1.00 adjustable Field of View Laser pointer D/S = Approx. 30:1 ratio (D = distance; S = spot or target) Dual, Class 2 laser < 1mW power; Wavelength is 630 to 670nm IR Spectral response 8 to 14 μm (wavelength) Repeatability ± 0.5% of reading or ± 1 o C (1.8 o F) whichever is greater General Specifications Display Backlit LCD display with function indicators Response time 150ms Over range indication --------- Operating Temperature 0 o C to 50 o C (32 o F to 122 o F) Operating Humidity 10% to 90%RH operating, <80%RH storage. Storage Temperature -10 to 60 o C (14 to 140 o F) Power Supply 9V battery Automatic Power Off 7 seconds, with LOCK to disable Weight 163g/ 5.7 oz. Dimensions 146 x 104 x 43mm (5.7 x 4 x 1.6 ) Copyright 2009 Extech Instruments Corporation (a FLIR company) All rights reserved including the right of reproduction in whole or in part in any form. 9