FOSS. Fiber Optic Stress Sensor. Kyungi Do, Korea Catalog

Similar documents
The unique foolproof-accurate-nuisance alarm free perimeter intrusion detection system by means of skin concept protection

Presented By. BEI Security

WG Buried Fibre Cable Long Perimeter Detection System

WG Buried Cable Perimeter Detection System

The Fiber SenSys Perimeter Intrusion Detection System From JM Fiber Optics!

SPECIFICATIONS OM- ARA- NET OM- ARA- TF CONTROLLER OPTICAL FIBER NET INTRUSION DETECTION SYSTEM

Committed to security

Home Intrusion Detection System

G-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System

Perimeter security using Fibre optics

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1100X

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1150

SL-3 Vibration Sensor line A&E Specifications Page 1 of 12 SL-3 AE v doc

WG Railway Security Protection System

Multi-layered Perimeter Protection Systems Quality detection systems for high security sites

Perimeter Intrusion Detection System

NSB-200S HOME INTRUSION DETECTION SYSTEM

INTREPID Perimeter Intrusion Detection System

Protecting Network Data

Fiber Optic Cable Fence Disturbance Sensor

7638 Standish Place Derwood, MD Tel: (301) Fax: (301) Page 1 of 12. Website:

Protecting Station Platform & Rail Perimeters. TransitVUE IDS The Latest in Fiber Optic Station Platform & Rail Perimeter Security Sensor Systems

Praetorian Fibre Optic Sensing

TOTAL PERIMETER SOLUTION

Novasky Radar Video Surveillance System

Section PERIMETER SECURITY SYSTEMS

Airport Perimeter Security

Product Specifications

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

RaySense. Fiber Optic Distributed Vibration Sensing (DVS) for Pipeline Security and Leak Detection

Architectural and Engineering Specification for a Fiber Optic Pipeline Integrity Monitoring System. FiberPatrol FP7000

Praetorian Fibre Optic Sensing

INTREPID Buried Cable Perimeter Intrusion Detection System

PROVEN PERIMETER PROTECTION NEW SINGLE-PLATFORM SIMPLICITY.

TOTAL PERIMETER SOLUTION

DATA CENTER SECURITY. March 2017 Anton Panaitescu

Praetorian Fibre Optic Sensing

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

P E R I M E T E R m i n i c a t a l o g u e

GPS or DCF 77. DTS Masterclock

Product Specification

ACCESS Master MT9085 Series. Product Introduction

Architectural and Engineering Specification for a Hybrid Perimeter Intrusion Detection and Intelligent Lighting System.

GAMMA OTDR application consists of main window and menu. Using menu user can operate in different modes of application.

THE BEST SOLUTIONS FOR OUTDOOR PERIMETER PROTECTIONS

KWX N4 PDU. Intelligent, Rack Mounted, Power Distribution Units. The most innovative PDU on the market KWX-N16A10C3-H4F MONITORED & SWITCHABLE PDU

INTREPID Buried Cable Perimeter Intrusion Detection System

Fiber Perimeter Monitoring System(FPMS)

Pipeline Intrastructure Monitoring for Third-Party Interference Detection

Remote fiber testing to improve SLA s

products and services

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

Reinforced FBG Sensors Serve Demanding Applications

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

M700-Series Multifunction OTDR

Consolidated Second Quarter of F.Y Presentation (Jan.1 to Jun.30, 2010) August 5th 2010 in Osaka August 6th 2010 in Tokyo

RaySense. Fiber Optic Distributed Acoustic Sensing for Pipeline Security and Leak Detection

Design of the Fiber-optic Fence Warning System with Distributed Video Real-Time Display Function Qiang-yi YI and Zheng-hong YU *

AQ7275 OTDR Optical Time Domain Reflectometer

AQ7275 OTDR Optical Time Domain Reflectometer

ACTIVE INFRARED BARRIER

ADPRO PRO Series by Xtralis

TW-8000 TAUT WIRE FENCE

- Basic information of Laser Scan detector

PERIMETER DEFENCE. Panorama Intruder Detection System Long Range, Day & Night, Automatic Panorama Intruder Detection

Dome Fiber Optic Closure SC-221

MINI2 MOST ACCURATE COMPACT OTDR

PIDS Sensor Installation & Maintenance. 15/03/13/Rev1/PIDS Sensor Installation & Maintenance 1

IRONCLAD Product Information

DTS MOBATime's Distributed Time System

2013 Honeywell Users Group EMEA. Adrian Fielding Security from Day One

G.M. Advanced Fencing & Security Technologies Ltd

About HGH Systemes Infrarouges About HGH

Pipeline Integrity Monitoring with DAS

4 Channel Contact Closure SFP DIN Fiber Link System

AV6416 OTDR. Product Overview: Main Features:

M210 Multifunction Micro OTDR

Advancing Pipeline Safety

WAVE SEQUENCER DELIVERS:


MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

PIR-100B User Manual

JVA Electric Security Fence System. perimeter intruder detection system

MicrOTDR. Optical Fault Locator. User Manual

RLDS - Remote LEAK DETECTION SYSTEM

N E W S R E L E A S E. Embargoed Until Tuesday, December 14, 2010

Galaxy Pulsar Plus Digital Battery Plant Controller

Industrial Strength Leak Detection

MANUFACTURER OF PERIMETER INTRUSION DETECTION SYSTEMS FOR CRITICAL INFRASTRUCTURE AND SENSITIVE SITES

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

InvisiFence User Manual

VIEW500 FASTEST STANDARD OTDR

Absorbance range Resolution Accuracy Type of microplate Wavelength Optic system Light source Wavelength accuracy. Calculation method

Gallagher D10 Tautwire Sensors & D21 Disturbance Sensors Integration with Gallagher

INTREPID SINGLE-PLATFORM PERIMETER INTRUSION DETECTION AND MONITORING SYSTEM

suite of security systems

RLS-3060SH REDSCAN ULTIMATE

Transcription:

FOSS Fiber Optic Stress Sensor 2016 Catalog To be buried underground or mounted to barriers for intruder detection Free from nuisance alarm Invisible to intruder Success Rate of detection : 95% or over Locate intruder presence within ± 25 meters No filed equipment up to 40km Easy to install & maintain Innovative Fiber Optic Security & Safety Systems Manufacturer www.fibertron.co.kr Kyungi Do, Korea Email : sensor@fibertron.co.kr doctorbaekorea@gmail.com Tel : +82 31 777 5612 / CP : +82 10 3783 4681

Page 2 Development Background FOM on Kuwait Diplomatic Facility Wall 2011 Dubai FOM at Korea Top Gov t Site Fence 2015 MAY FOSM (Fiber Optic Security Mesh) operates based on the unique Optical Radar principle and throughout its worldwide installations over 15 years has been reputed as the unique foolproof accurate intrusion detection system being free from nuisance alarm. However FOSM costs high relatively and its application depends on fence type and perimeter condition. Over the world exists no reliable intrusion detection system available for pipe line protection and for intruder disturbing barrier such as concertina and marine barrier. Recently Fibertron Co., Ltd. presented FOSS (Fiber Optic Stress Sensor) as an extended application of FOSM technology to be buried underground or mounted to barriers so as to trigger alarm at intruder s disturbances and locate within ± 25 meters being free from nuisance alarm. The FOSS uses FOSC in combination with a number of appropriate mechanical parts (tiny pipe, rod, wire, etc.) as per specific application and shall provide new pipeline protection or detect intruder disturbances to barrier for the highest cost benefit which has not been seen ever. Normal Optical Fiber Optical Pulses Intrusion Cutting or Excessive Force Optical Pulses

Page 3 FOSS for Pipeline Protection Here describes,for example, FOSS (Fiber Optic Stress Sensor) System construction along 200km pipeline(s). Bury FOSS under ground along both sides of pipeline(s) to detect intruder presence in close proximity to the pipeline(s) on the soft ground. Presence of heavier vehicle such as poclain or car should be surely detected. A number of FOSC (Fiber Optic Sensor Cable) along the pipelines(s) shall be connected to OSU (Optical Sensing Unit) at 15km interval typically. All the fifteen OSU along the 200km pipeline(s) shall be connected to & controlled via WAN or SMF by ACS (Alarm Control Station) at SCC (Security Control Center). Each Optical Port of OSU shall periodically inject Infrared Laser pulses into each FOSC to identify intrusion from the presence of abnormal Optical echoes related by external pressure and report abnormal Optical echoes to ACS for triggering alarm and locating the intrusion spot within ±25meters on its own map. Each OSU should be capable to detect up to four (4) simultaneous intrusions per 15km. The system shall be free from nuisance alarm being immune to such environment effect as rain, sand storm, air jet, vehicle vibration, lightning, thunder, power line, EMI/RFI, UV rays, temperature variation, falling debris, birds etc.

Page 4 Buried FOSS under Grasses Bury FOSS under grass or soft ground in the vicinity of the fence/wall to trigger an alarm at an intruder presence. FOSS buried underground FOSS buried under Grasses FOSS buried underground 60 30 30 5 30

Page 5 Hardware Specification FOSS-Buried, uncovered FOSS-Buried, covered 1 : PSH (Pressure Sensing Head) FOSS-Buried, Drawing 2 : PSB (Pressure Sensing Bar) 3 : FO Sensor Cable Specification of FOSS-Buried The FOSS-Buried consists of a FOSC (Fiber Optic Sensor Cable) and metal parts such as PSB (Pressure Sensing Bar) and PSH (Pressure Sensing Head). Either one or both ends of FOSC shall be connected to OIA (or OSU) to receive Optical pulses periodically to return back the Optical echoes. Thus it serves as bidirectional transmission line for both Infrared Laser pulses and Optical echoes. Sensing Origin : displacement 1 cm typical PSH Size : 25Φx300 PSH Material : SK5 PSH Weight : 2kg PSB Size : 32x3tx1500 PSB Material : SS41, Zn Coat PSB Weight : 5kg Immune to weather and water enviroment Operating Temp. : -25 ~ +75 Power requirement : None

Page 6 To mount FOSS on the concertina top on the Wall Mount the FOSS to the Concertina on top of the Wall to trigger an alarm when an intruder steps on the concertina while climbing over.

Page 7 FOSS detecting Intruder Climbing Concertina Barrier Concertina mounted to a Wall FOSS on Concertina Top Concertina coil(s) can be put either on the fence/wall top or wall top or laid on the ground for the purpose of prohibiting intruder trespassing. Cutting through concertina coil(s) is much more difficult compared to cutting fence mesh. Usually concertina coil(s) are placed high on the fence/wall. Thus mounting FOSS to concertina top to trigger alarm when an intruder steps on the concertina while climbing over can be good enough to secure the perimeter costing very low. 7

Page 8 FOSS for Marine Barrier Crash Impact Detection The FOSS design for the Marine Barrier Crash Impact Detection can be easily described by the Spine Analogy. The Human Spine is formed of 26 small segments. Each segment is only a few centimeters. All 26 spine segments share the same internal nerve, which is connected to the brain. Tiny transverse impact to any spine segment by injury or disease will exert stress to the internal nerve and the nerve will send a pain signal to the brain resulting in an "alarm" being created by the brain at the location of stress.. The FOSS implemented to Marine Barrier 5.1KM for example is formed of 3,400 FOSS segments. The FOSS segment is typically 1.5M. All the 3,400 FOSS segments share the same FOSC inside which is connected to OIA (Optical Intrusion Alarm). Tiny transverse impact to any FOSS segment by external crash will exert stress to the FOSC inside to result in alarm at OIA. One of the main reasons to implement FOSS in 1.5M unit is to sensitively detect a localized disturbance (crash by a boat) filtering out distributed disturbances by waves. FOSC is immune to sea environment (water, salt, wind, rain, shun shine, fishes, noise, lightening, thunder, temperature etc.) Due to no fielded electronic equipment and fiber optic cable being rated for marine environment, the FOSS will detect Marine Barrier crash impacts, without nuisance alarms, for the most cost-effective protection. Marine Barrier Whisprwave from Wave Dispersion Tech, Inc. NJ, USA www.whisprwave.com Human Spine

Page 9 FOSS for Marine Barrier Crash Impact Detection Metal Pipe FOSC Fiber Optic Sensor Cab The purpose of the FOSS (Fiber Optic Stress Sensor) is to detect Marine Barrier Impact by boat, bombing or hostile disturbances without nuisance alarming due to waves. Let s describe FOSS construction to protect a Marine Barrier along a 5.1 KM marine perimeter. FOSS System Diagram A FOSC (Fiber Optic Sensor Cable) inserted in a metal pipe shall be inserted in the middle hole/other hole of the Marine Barrier floating on t he marine perimeter acting as the nerve spine of the barrier. Both ends of the FOSC are connected to the control equipment OIA(Optical Intrusion Alarm) at SCC (Security Control Center). The OIA Proposing shall periodically Background and continuously pumps Infrared Laser pulses into both ends of the FOSC and monitor the presence of any atypical Optical Backscatter caused by Marine Barrier Impact by boat, bombing or hostile disturbances. At receiving of Optical echoes, the OIA shall generate audible and visible alarm indicating the intrusion spot within ±25 meter on its own monitor. The OIA will detect at least one intrusion from both directions of FOSC inserted into 5.1km Marine Barrier. The sensitivity of FOSS can be set/adjusted to ensure the alarm at intruder disturbances while filtering our nuisance alarms related to marine environment such as waves, wind, fishes, etc.

Page 10 FOSS System Diagram along 10KM, typical FOSS System Diagram along 200KM, typical

Hardware Specification Page 11 FOSC (Fiber Optic Sensor Cable) A FOSC can be inserted along with a pipe inside a marine barrier to sense external disturbance to the barrier. Either one or both ends of FOSC shall be connected to OIA to receive Optical pulses periodically. The FOSC serves as bidirectional transmission line for both Infrared Laser pulses from and Optical Echoes to the OIA. The FOSC was specially designed for dual purposes as transmission and sensor by having the unique structure of a single core of multimode Optical fiber covered with heavy duty polyurethane jacket along with embedded Kevlar yarn for immunity to environment and proper strength. Specification of FOSC-1C The cable diameter/color : 3mm/black Optical fiber grade : 125 μm multimode Tensile Strength : 10kg, typical Operating temperature : -40 + 75 Environmental characteristics : Immune to water (rain, snow, haze etc)/electricity ( lightening, electrostatic, ground loop, power line, EMI, RF etc)/ sound & vibration (wind, storm, sound. vehicle vibration etc) Lifetime : over 15 yrs for proper maintenance Weight : 10kg /km FOSC

Page 12 Control Equipments The ACS is the intelligent main unit which receives the presence of the abnormal Optical echoes from OSU and processes it to identify and pinpoint on monitor with visible and audible alarms. There are two different models. ACS-nP houses an OSU-nP in the same rack. ACS-kT is to control k OSUs at separate remote location. ACS also provides OTDR service function and operation data storage. ACS provides input ports for other sensors such as IR Sensor, Shock Sensor, Door Locks etc and communication ports with other PC, CCTV Control, Server PC, LAN, Internet etc ACS(Alarm Control Station) ACS - np ACS-nP/kT (Alarm Control Station) Operation mode : Normal, Test, Emergency,Setting,Stop Sensing mode : cutting and/or excess force Location Accuracy : ±1m, ±15m, ±25m, Optional No of Optical ports : n (upto 8) No of terminals : k OSUs (upto 64 typical) External connection port : PC interface Fiber Optic test function : semi-otdr Auto-logging : alarm, action, status, setting value etc Monitor : 17" color Interface : dry contacts, serial or LAN Acceptable output devices : warning light, signal phone Acceptable input devices : IR/MW sensor, shock sensor O/S : Window XP Dimension : 195 x 60 x 75cm or 150 x 60 x 75cm Operating condition : indoors Power : AC220V±10% 50/60Hz, 400Watt approx ACS - kt The OSU injects infrared Laser Pulses into the FOM and measures any optical echoes to pick up any external disturbances. The OSU transmit abnormal symptom data to the Alarm Control Station to process and trigger an alarm. The OSU is either housed within ACS-nP or remotely at the site. OSU (Optical Sensing Unit) OSU-nP (Optical Sensing Unit) No of Optical Ports : n (upto 8) Sensing coverage per Optical port : 3m x 250m for break, 3m x 200m for excess force stronger than 20kg Fiber Optic connector type : FC multi-mode Dimension : 177 483 300 mm Weight : 10 kg, typical Operating condition : indoors, inside shelter for outdoors Power : AC220V±10% 50/60Hz, 250Watt OIA-nP is a PC body size desktop version of ACS-nP. OIA injects Infrared Laser Pulses to the FOSC (Fiber Optic Sensor Cable) periodically and shall identify & accurately locate the presence of intrusion from the abnormal Optical Echoes to trigger an alarm visibly & audibly operators. OIA also provides OTDR service function and operation data storage. ACS provides input ports for other sensors such as IR Sensor, Shock Sensor, Door Locks etc and communication ports with other PC, CCTV Control, Server PC, LAN, Internet etc. OIA-nP (Optical Sensing Unit) Operation mode : Normal, Test, Emergency, Setting, Stop OIA (Optical Intrusion Alarm) Sensing mode : cutting and/or excess force Location Accuracy : ±1m, ±15m, ±25m, Optional No of Optical Ports : n (maximum 8) Sensing mode : cutting, excess force, selectable External connection port : PC interface Fiber Optic test function : semi-otdr Auto-logging : event data (alarm,action,status,setting value etc) Monitor : 8.4" LCD color built in or 17 LCD external Interface : dry contacts, serial or LAN Acceptable output devices : warning light, signal phone O/S : Window XP Dimension : 19 4U (177 483 300 mm) Operating condition : indoors Power : AC220V±10% 50/60Hz, 100Watt approx