STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

Similar documents
STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

TECHNICAL DATA OBSOLETE

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

standard/quick response extended coverage light and ordinary hazard elo sprinklers

Microfast quick response Fusible element hsw sprinkler

microfast quick response extended coverage hsw sprinkler vk606

standard response fusible link sidewall sprinkler VK112 (K5.6)

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

quick response horizontal sidewall sprinkler vk360 (K8.0)

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

standard response elo upright and pendent sprinklers (storage-density/area)

microfast sr/qr extended coverage pendent sprinkler

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

TECHNICAL DATA. Page 1 of 6

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

STANDARD/quick. Sprinkler 42o. August 8, 2011

micromatic Standard response Horizontal Sidewall sprinkler

TECHNICAL DATA. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart.

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

microfast quick response Pendent sprinkler VK302 (K5.6)

standard response Fusible Link Upright sprinkler VK204 (K8.0)

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK534 (K11.2)

micromatic Standard response Horizontal Sidewall sprinkler

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

sprinkler vk538 (K11.2)

freedom residential horizontal sidewall sprinkler Vk450 (k4.2)

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

micromatic standard response stainless steel sprinklers

TECHNICAL DATA OBSOLETE

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

TECHNICAL DATA OBSOLETE

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

MIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA

standard response elo upright sprinkler

standard response/ quick response extended coverage

MicrofastHP QUICK RESPONSE HORIZONTAL SIDEWALL HIGH PRESSURE SPRINKLER VK319 (K5.6) TECHNICAL DATA

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

quick response Sprinkler 105a October 25, 2010

MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

standard response dry horizontal sidewall sprinklers

microfast and microfasthp quick conventional sprinklers

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK460 (K5.8) TECHNICAL DATA

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

TECHNICAL DATA vk470 (K3.0)

Quick response concealed horizontal sidewall sprinkler VK481

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

freedom residential pendent sprinkler vk466 (K5.2)

standard response dry horizontal sidewall sprinklers

micromatic standard response Upright sprinkler VK100 (K5.6)

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

TECHNICAL DATA. Page 1 of 5

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

FREEDOM RESIDENTIAL PENDENT LEAD FREE SPRINKLER VK4700 (K3.0) TECHNICAL DATA

standard response large orifice dry

Standard Spray concealed horizontal sidewall sprinkler VK481

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA

Transcription:

May 14, 2010 Sprinkler 85h 1. DESCRIPTION Viking Standard/QREC Light Hazard ELO Fusible Element Pendent Sprinkler VK617 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying design requirements. The sprinkler has both quick response and standard response listings as indicated in the Approval Charts on pages 85k-l. The special Polyester coating can be used in decorative applications where colors are desired. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Classes 2020 and 2022 Refer to Approval Chart 1 and Design Criteria on page 85k for culus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 85l for FM Approval requirements that must be followed. For Light Hazard Occupancies Only 3. Specifications: Available since 2007. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart. The Viking Corporation s Web site at Maximum Working Pressure: 175 psi (12 Bar). Factory tested hydrostatically http://www.vikinggroupinc.com. to 500 psi (34.5 bar). The Web site may include a more recent Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 3/4 (20 mm) NPT edition of this Technical Data Page. Nominal K-Factor: 11.2 U.S. (161.3 metric ) Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. Overall Length: 2-5/16 (59 mm) Material Standards: Sprinkler Frame: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-C51000 Fusible Element Assembly: Nickel Alloy Trigger and Support: Stainless Steel UNS-S31600 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Seat and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Screw: Brass UNS-C36000 For Teflon Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Standard/QREC Light Hazard ELO Fusible Element Pendent Sprinkler VK617 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflon = N Temperature Suffix ( F/ C): 165 /74 = C and 205 /96 = E For example, sprinkler VK617 with a Brass finish and a 165 F/74 C temperature rating = Part No. 14141AC Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the Sprinkler Accessories section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 05118CW/B (available since 1981) B. Wrench for recessed pendent sprinkler: Part No. 11663W/B** (available since 2001) **A ½ ratchet is required (not available from Viking). Form No. F_021207 Replaces page 85h-m, dated June 1, 2007. (Updated FM Approvals and split the Approval Charts to separate culus Listings from FM Approvals.)

Sprinkler 85i May 14, 2010 Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive fusible element assembly disengages, releasing the seat and spring assemblies to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler VK617 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking s current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 05118CW/B

May 14, 2010 Sprinker 85j TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating 1 Maximum Ambient Ceiling Temperature 2 Frame Paint Color Ordinary 165 F (74 C) 100 F (38 C) None Intermediate 205 F (96 C) 150 F (65 C) White Sprinkler Finishes: Brass, Chrome-Enloy, White Polyester 3, Black Polyester 3, and Black Teflon 3 Footnotes 1 Decorative sprinklers may not be color coded. The temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon coatings. For Teflon coated open sprinklers only, the waterway is coated. Figure 2: Wrench 11663W/B for Recessed Pendent Sprinkler VK617

Sprinkler 85k May 14, 2010 Sprinkler Base NPT Thread Size Nominal K-Factor Maximum Water Overall Length SIN Part Number 1 Inches mm U.S. metric 2 Working Pressure inches mm 14141 VK617 3/4 20 11.2 161.3 175 psi (12 Bar) 2-5/16 59 Approval Chart 1 (UL) Standard Response/QREC ELO Pendent Sprinkler VK617 For Light Hazard Occupancies Only Maximum Sprinkler Spacing 4 (Length x Width) Maximum Area per Sprinkler Listings and Approvals 3 Minimum Water Supply Requirements 4 (Refer also to Design Criteria below.) culus 5 NYC Standard Response 7 12 ft. x 12 ft. (3.7 m x 3.7 m) 144 ft 2 (13.4 m 2 ) 30 gpm @ 7.2 psi (113.6 L/min @.50 Bar) A1Y See Footnote 6. 14 ft. x 14 ft. (4.3 m x 4.3 m) 196 ft 2 (18.2 m 2 ) 30 gpm @ 7.2 psi (113.6 L/min @.50 Bar) A1Y See Footnote 6. Quick Response 16 ft. x 16 ft. (4.9 m x 4.9 m) 256 ft 2 (23.8 m 2 ) 30 gpm @ 7.2 psi (113.6 L/min @.50 Bar) C1Y, B1X See Footnote 6. 18 ft. x 18 ft. (5.5 m x 5.5 m) 324 ft 2 (30.1 m 2 ) 33 gpm @ 8.7 psi (124.9 L/min @.60 Bar) C1Y See Footnote 6. Approved Temperature Ratings A - 165 F (74 C) and 205 F (96 C) B - 205 F (96 C) C - 165 F (74 C) Approved Finishes 1 - Brass, Chrome-Enloy, White Polyester, Black Polyester, and Black Teflon Approved Escutcheons X - Standard surface-mounted escutcheons or the Microfast Model F-1 Adjustable Escutcheon Y - Standard surface-mounted escutcheons or the Microfast Model F-1 Adjustable Escutcheon, or recessed with the Micromatic Model E-1 or E-2 Recessed Escutcheon Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This chart shows listings and approvals available at time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 For areas of coverage smaller than shown, use the Minimum Water Supply Requirement for the next larger area listed. Flows and pressures listed are per sprinkler. 5 culus Listed for use in the U.S. and Canada for Light Hazard occupancies with smooth, flat, horizontal ceilings only. 6 Meets New York City requirements, effective July 1, 2008. 7 Listings are limited to Light Hazard Occupancies where allowed by the installation standards being applied. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) culus Listing Requirements: Standard/QREC Light Hazard ELO Fusible Element Pendent Sprinkler VK617 is culus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for extended coverage pendent spray sprinklers: Limited to Light Hazard occupancies, where allowed by the installation standards being applied, with smooth, flat, horizontal ceilings only. Minimum spacing allowed is 8 ft. (2.4 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for extended coverage pendent spray sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to pages EC1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable.

May 14, 2010 Sprinkler 85l Sprinkler Base NPT Thread Size Nominal K-Factor Maximum Water Overall Length SIN Part Number 1 Inches mm U.S. metric 2 Working Pressure Inches mm 14141 VK617 3/4 20 11.2 161.3 175 psi (12 Bar) 2-5/16 59 Maximum Sprinkler Spacing 4 (Length x Width) Approval Chart 2 (FM) Quick Response Extended Coverage ELO Pendent Sprinkler VK617 Maximum Area per Sprinkler Minimum Water Supply Requirements 4 FM Approvals 3 (Refer also to Design Criteria below.) 16 ft. x 16 ft. (4.9 m x 4.9 m) 256 ft 2 (23.8 m 2 ) 30 gpm @ 7.2 psi (113.6 L/min @.50 Bar) A1X 18 ft. x 18 ft. (5.5 m x 5.5 m) 324 ft 2 (30.1 m 2 ) 33 gpm @ 8.7 psi (124.9 L/min @.60 Bar) A1X Approved Temperature Rating A - 165 F (74 C) Approved Finishes 1 - Brass, Chrome-Enloy, White Polyester, and Black Polyester Approved Escutcheons X - Standard surface-mounted escutcheons or the Microfast Model F-1 Adjustable Escutcheon, or recessed with the Micromatic Model E-1 or E-2 Recessed Escutcheon Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This chart shows listings and approvals available at time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 For areas of coverage smaller than shown, use the Minimum Water Supply Requirement for the next larger area listed. Flows and pressures listed are per sprinkler. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: Sprinkler VK617 is FM Approved as a quick response Non-Storage extended coverage pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from culus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to pages EC1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable.

Sprinkler 85m May 14, 2010 Figure 3: Sprinkler VK617 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Figure 4: Sprinkler VK617 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_021207 Replaces page 85h-m, dated June 1, 2007. (Updated FM Approvals and split the Approval Charts to separate culus Listings from FM Approvals.)