Yaskawa Electric America Training Café

Similar documents
SAFETY RELAY APPLICATION

FUNCTIONAL SAFETY OF ELECTRICAL INSTALLATIONS IN INDUSTRIAL PLANTS BY OTTO WALCH

Operating Guide Safe Torque Off

Functional Safety & Power Drive Systems

Functional Safety of Machinery: EN ISO Stewart Robinson. Overview of the presentation. References. TÜV SÜD Product Service

ISIS SAFETY SYSTEM Installation guide

SIL Safety Guide Series MS Single-Acting Spring-Return Hydraulic Linear Actuators

Measurement of Safety Integrity of E/E/PES according to IEC61508


Functional Safety of Machinery Presented by Greg Richards Manufacturing in America 02/22-23/2017

Operating Guide Safe Torque Off

PPA Michaël GROSSI - FSCE PR electronics

Safety. Detection. Control. SAFETY INTERFACES. Safety Interfaces and Relays. Product catalogue. Issue 1

Original operating instructions Safety switch with guard locking AC901S AC902S

Original instructions Sense7-series Non-contact coded safety switch

SensaGuard TM Integrated Latch Installation Instructions

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express

Operating Manual MS220DA

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK

For Complete Fire and Gas Solutions

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

Where Process Safety meets Machine Safety

Installation Instructions CS3 Three Phase Solid State Relay

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

DTA04. Motor thermistor relay. Benefits. Description

Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018

Digital EPIC 2 Safety manual

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

INTERNATIONAL STANDARD

United Electric Controls One Series Safety Transmitter Safety Manual

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

First of all, what is a safety-related

Operating Manual MS220KA and MSR220KA

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Overfill Prevention Control Unit with Ground Verification & Vehicle Identification Options. TÜVRheinland

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

SAFETY INTERFACES SAFETY INTERFACES AND RELAYS

Easy Implementation of the European Machinery Directive

FAQs Radio Equipment Directive (RE-D)

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update

Basics of Safety Applications

User s Manual. YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters. Manual Change No

The Machinery Directive 2006/42/EC

Operating Instructions VLT PTC Thermistor Card MCB 112

INTERNATIONAL STANDARD

New Developments in the IEC61511 Edition 2

Overview of Standards for CO Detection Products

100 & 120 Series Pressure and Temperature Switches Safety Manual

Basics of Safety Applications

/ / 2018

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

Proof Testing Level Instruments

FMEDA Report. Failure Modes, Effects and Diagnostic Analysis. KFD0-CS-Ex*.54* and KFD0-CS-Ex*.56* Project: X7300

Functional Safety of Machines and Systems Convenient Implementation of the European Machinery Directive

Automation, Software und Informationstechnologie

Functional Safety SIL Safety Integrity Level

RE-PR3-E-27 3-Phase Panel Mount 27kW

Latch key safety limit switches Technical data

Magnetically Coded Non-contact Switch (MC2)

Module Features are-configurable, no module jumpers to set

Safety Speed Monitoring

INTERNATIONAL STANDARD

SCHMIDT LED Measured Value Display MD Instructions for Use

DTA. Motor thermistor relay. Benefits. Description

Functional Safety: What It Is, Why It s Important And How to Comply

Understanding NFPA, NEC 2005 Article 409 a White Paper by Paul A. Terry, P.E.

Reference Manual. Safety Integrated. Introduction and Terminology for Functional Safety of Machines and Systems. Edition 03/2018. siemens.

M2500 Engine Controller Installation Manual

The Impact of Marking Requirements. on Design and Performance of Power Converters and Electrical Drives

Public Safety DAS Annunciator Panel

Project planning (original) EN. Functional safety. Inverter i550-cabinet kw

The agri-motive safety performance integrity level Or how do you call it?

Pilz Safety Lockout System (PSLS)

The European Standardization System. Diana Dus Programme Manager International Cooperation

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

PTE0705 Electric Fence Monitor

UV Flame Supervision System

WIO200 Water In Oil measuring instrument

Protection Chain IQ-Sensor + Relaiy device T420

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

Certification Report of the ST 3000 Pressure Transmitter with HART 6

Standards and Trends in Machine Safety -A changing World -

Improved productivity Two-stage detection

Introduction to machine safety

Instruction Manual December 2001 ENACOCU02

Guidelines. Safety Integrity Level - SIL - Valves and valve actuators. February Valves

Instructions for the fan motor control system, SILVER C

Technical Data. Dimensions

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

INTERNATIONAL STANDARD

SIL725 Safety Annunciator

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

CU-02 with Senaco Plus

Process Safety - Market Requirements. V.P.Raman Mott MacDonald Pvt. Ltd.

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

The Process of making European Standards. Frank Moore Chairman CEN TC/248 Textiles

Analog Annunciator Unit SACO 16 A3. Product Guide

Session Ten Achieving Compliance in Hardware Fault Tolerance

Transcription:

Functional Safety Yaskawa Electric America Training Café Today s topic is Functional Safety Standards & Safe Disable Presenter is Joe Pottebaum Senior Applications Engineer To make this Café enjoyable for all, please follow these tips on web class etiquette. Please do not put us on hold. Others will hear the hold music. Do not use a speaker phone. Background noise can be heard. Don t be shy, we welcome comments and questions. (Press *6* to mute or unmute your phone) Questions not answered during the Café can be emailed to training@yaskawa.com or can be entered into the survey at the end of the class. 1

English Definition - Safety Safety 1. the state of being safe; freedom from the occurrence or risk of injury, danger, or loss. 2. the quality of averting or not causing injury, danger, or loss. 3. a contrivance or device to prevent injury or avert danger. safety. Dictionary.com. Dictionary.com Unabridged (v 1.1). Random House, Inc. http://dictionary.reference.com/browse/safety (accessed: April 21, 2009). 2

Safety Standard s Definition of Safety Safety = Freedom from Unacceptable Risk What makes risk acceptable? Who determines? 3

Determination of Risk Acceptability Individuals and Society determine what risk is acceptable. Standards, Codes and Laws reflect those expectations. 4

Traditional Approach Make each piece of equipment safe by constructing it according to appropriate standards (UL, CSA, etc.). Slather it with warning labels. Install it according to code (NEC). Train operators in its proper safe use. Assume operators will always follow safe practice. 5

History: IEC 61800-5-1 6

History: NFPA 70 = NEC 7

Traditional Equipment Safety Standards Historical Equipment Safety Concerns: Don t Start Fires Don t Electrocute Anybody 8

Safe is Safe, Right? A system comprising all safe components can still function in an unsafe manner. 9

Equipment Safety vs. Functional Safety Yaskawa Training Cafe Equipment Safety z z z z z z Is the individual piece of equipment safe? Is electrical insulation adequate? Is the ground wire fat enough? Is the door interlocked with the circuit disconnect? Etc. etc. etc. Meet UL, CSA, CE, etc. 4/22/2010 Functional Safety z Will the machine as a whole always function safely? z Can this be guaranteed to within an acceptable level of risk? Functional Safety & Safe Disable 10

Drive is Only a Component No matter how big they are, Yaskawa Drives are only Components in the Safety System. 11

Equipment Safety vs. Functional Safety We must distinguish between safety functions integrated into equipment the safety of a facility or enforcing safe practices. 12

Functional Safety Definition Functional Safety is part of overall safety that depends on a system of equipment operating correctly in response to its inputs. 13

Directives, Standards & Laws in EU EU formulates general safety objectives via directives. Directives are not binding until set into law by individual countries. Standards are legal when published in Official Journal of the EU and referenced by domestic laws, ie. harmonized. Adherence to harmonized standards confers Presumption of Conformity. 14

Presumption of Conformity 'Presumption of conformity' means that if a manufacturer has complied with the standard, then it can assume it has met the requirements of the directive. Legal effect is reversal of the burden of proof. 15

Reversal of the Burden of Proof When there is a problem: Where the manufacturer applies a standard, misconduct must be proved. Where the manufacturer has not applied a standard, the manufacturer must prove it has acted in compliance with the directive. 16

The CE Mark CE = Communauté Européenne The CE mark documents that the manufacturer has considered all the EU directives relevant to the product and applied the appropriate conformity assessment procedures, ie. tested to the relevant standards. 17

Machinery Directive Machinery Directive covers Yaskawa Drives. Revised Machinery Directive 2006/42/EC took effect December 29, 2009. EU domestic laws require that machines meet the Essential Health and Safety Requirements (EHSR) defined in the Machinery Directive. 18

CE Mark Comply with the Standards Meets the Directive Fulfill Essential Health and Safety Requirements (EHSR) 19

Functional Safety Systems Safety is integrated into machine's functionality not just warning labels added to meet regulations So what standards apply to meet Essential Health and Safety Requirements (EHSR)? 20

What is a Machine? Article 2 of Machinery Directive: An assembly of linked parts or components, at least one of which moves, and which are joined together for a specific application. 21

Functional Safety Standards Was EN 954-1 Now Either EN (IEC) 62061 Or EN (ISO) 13849-1 Take your pick! 22

What Changed Old EN 954-1 defined safety categories meet them and you are done. New standards based on probability. Manufacturer must ensure safety by performing assessment calculations. 23

Alphabet Soup 24

Take Your Pick EN ISO 13849-1:2008 (Safety of Machinery -Safety-related Parts of Control Systems - General Principles for Design) EN (IEC) 62061:2005 (Safety of Machinery - Functional Safety of Safety-related Electrical, Electronic and Programmable Electronic Control Systems). 25

International Yaskawa Training Cafe IEC = International Electrotechnical Commission ISO = International Organization for Standardization 4/22/2010 Functional Safety & Safe Disable 26

ISO vs. IEC ISO: standardization in all fields except electrical and electronic engineering IEC: electrical and electronic engineering standards Both ISO and the IEC operate according to similar rules. Members are national standards organizations like ANSI, DIN, etc. The adoption of ISO and/or IEC standards into the national collections is voluntary. Adoption may be complete or partial. 27

IEC 61508, ISO 13849-1, IEC 62061 IEC 61508 = Functional Safety of Electrical / Electronic / Programmable Electronic (E/E/PE) Safety Related Systems. Seven parts of IEC 61508 were published by CENELEC in December 2001 as EN 61508 Principles in IEC 61508 carried into both ISO 13849-1:2008 and IEC 62061:2005 28

Differences ISO 13849-1 Any type of control Uses Performance Levels PL PL a, b, c, d, or e PL a is lowest IEC 62061 Electrical Control Use Safety Integrity Levels SIL SIL 1, 2, or 3 SIL 1 is lowest, 29

Safety Related System & IEC 61508 What is a safety-related system in the context of IEC 61508? A safety-related system comprises everything (hardware, software and human elements) necessary to carry out one or more safety functions, where failure of the safety function would give rise to a significant increase in the risk to the safety of persons and/or the environment. A safety-related system can comprise stand-alone equipment dedicated to perform a particular safety function (such as a fire detection system) or can be integrated into other plant or equipment (such as motor speed control in a machine tool). 3.4.1 of IEC 61508-4 gives a formal definition. 30

What is Functional Safety in 61508 What is functional safety? Functional safety is part of the overall safety that depends on a system or equipment operating correctly in response to its inputs. Functional safety is achieved when every specified safety function is carried out and the level of performance required of each safety function is met. For example, an overtemperature protection device, using a thermal sensor in the windings of an electric motor to de-energise the motor before they can overheat, is an instance of functional safety. But providing specialised insulation to withstand high temperatures is not an instance of functional safety (although it is still an instance of safety and could protect against exactly the same hazard). See the document Functional safety and IEC 61508 for further details. 31

ISO 13849-1 Performance Levels Similar to EN954-1 Levels B, 1, 2, 3 and 4 32

IEC 62061 SIL What is a safety integrity level (SIL)? A safety integrity level is one of four levels, each corresponding to a range of target likelihood of failures of a safety function. Note that a safety integrity level is a property of a safety function rather than of a system or any part of a system. 33

SIL for Component What is meant by a SILn system, subsystem or component? A safety integrity level (SIL) is not a property of a system, subsystem or component. The correct interpretation of this phrase is that the system, subsystem or component is capable of supporting safety functions with a safety integrity level up to n. This in itself is not sufficient to achieve a safety function of the required safety integrity level. The safety integrity level capability of a subsystem determines the highest safety integrity level that can be claimed for any safety function that uses the subsystem. For this reason, the term safety integrity level claim limit is sometimes used instead. A SILn capability or claim limit (where n is 1,2,3 or 4) is determined for each subsystem by achieving a or b below. The design requirements for SILn to prevent and control systematic faults in accordance with IEC 61508-2 and IEC 61508-3; or The proven in use requirements for SILn in accordance with 7.4.7.6 to 7.4.7.10 of IEC 61508-2. Other information about the system, subsystem or component is also necessary to facilitate a demonstration that the required safety integrity level of the safety function in the E/E/PE safety-related system will be achieved. 34

Functional Safety Requirement NOT ONLY -- Equipment must have reliable safe construction UL, CE, CSA, etc. BUT ALSO -- Equipment must function correctly in response to safety related inputs Functional Safety 35

Freedom from Risk of Injury Total freedom from risk is not achievable Need a measurement of risk Need an operational definition of safety 36

Risk Assessment How safe is safe enough? To find out do a Risk Assessment. 37

ISO13849-1 (Successor to EN954-1) Safety-related parts of control systems Part1: General principles for design ISO13849-1, JIS B 9705 Covers the design procedures for components related to safety in a system. Determines the danger level by looking at the severity of potential injury and the probability of an accident causing those injuries. Specifies what types of safety measures are needed for control to cover each of the five levels of danger. 38

Category Assessment Table Results from Risk Analysis Preferred categories Additional measures possible Measures may be excessive Safety Measures Evaluation Category B 1 2 3 4 Safety Categories Based on ISO13849-1 Determines the danger level by looking at the severity of potential injury (serious injuries vs. light injuries) and the probability of an accident causing those injuries. S1: Slight injury (bruising, etc.) S2: Serious injury (amputation, death ) F1: Low frequency, short-term only F2: Frequent high risk for long periods P1: Avoidable P2: Inescapable P1: Avoidable P2: Inescapable S: Severity of injury F: Frequency and/or duration of exposure to the hazard P: Possibility of avoiding the hazard The higher the values are for B,1,2,3, and 4, the more safety measures are required. When there is a high possibility of severe injuries, then the safety category will indicate that more comprehensive steps be taken (parts, system design) to ensure safety. 39

EN954-1: the five categories for safetyrelated parts of control systems Category B The basic category --The occurrence of a fault can lead to loss of safety function; Category 1 Improved resistance to faults is achieved predominantly by selection and application of components. This is achieved by using well-tried components and well-tried safety principles. Category 2 Category 1 requirements plus control system is designed so safety-related functions are checked at suitable intervals by the machine control system. After detection of a fault, a safe state will be maintained until the fault has been cleared. Category 3 Improved so that a single fault will not lead to loss of a safety function. Common mode faults need to be taken into account when the probability of such a fault occurring is significant. Whenever reasonably practical, the single fault should be detected at or before the next demand for the safety function. All faults are not required to be detected, thus an accumulation of undetected faults could lead to hazardous situation. Category 4 All faults will be detected and there will the protection against an accumulation of faults which needs to be specified. The safety-related parts of the control need to be designed so the a single fault does not lead to a loss of safety function and the single fault will be detected at or before the next demand for the safety function. This category of safety requires that when faults occur the safety function is always performed and the faults will be detected in time to prevent the loss of the safety function. 40

Reality for Yaskawa The Drive is only a Component in the overall safety system The drive s only responsibility is to respond predictably to its safety inputs Safe Disable For Yaskawa V1000, A1000 drives: Opening Safe Disable input => Motor Coasts 41

EN 60204-1 This part of IEC 60204 is applicable to the electrical equipment or parts of the electrical equipment that operate with nominal supply voltages not exceeding 1000 V for alternating current and not exceeding 1500 V for direct current, and with nominal supply frequencies not exceeding 200 Hz. Covers all aspects of electrical equipment and machinery in regards to control circuits, functions, devices, and safety measures, as well as documentation explaining installation, operation, and maintenance. 42

Stop Categories & Safe Disable Input Electrical equipment of machines Part1: Specification for general requirements IEC standards: IEC60204-1 JIS standards: JIS B 9960-1 Yaskawa s Safe Disable feature satisfies both Category 0 defined in EN60204-1 (STO defined in IEC 61800-5-2) for an uncontrolled stop and Category 3 of EN954-1. Safe Disable can be integrated into any sequences or circuits the user has set up for machine safety. Stop Categories 0 or STO: Stopping by immediate removal of power to the machine actuators (i.e., an uncontrolled stop or coast to stop or Safe Torque Off) 1 or SS1: Stopping in a controlled manner, with power made available so that the machine actuators can achieve the stop, the power removal when the stop is achieved (ramp to stop followed by STO) 2 or SS2: Stopping in a controlled manner, with power left available to the machine actuators (Zero Servo or SOS Safe Operating Stop) 43

STOP Categories / IEC61800-5-2 Stop Categories Illustration V1000, A1000, F7(option) Servo + Options Servo + Options EN 60204-1 (VDE 0113): Stop Category 0 IEC 61800-5-2: Safe Torque Off (STO) Remove Energy EN 60204-1 (VDE 0113): Stop Category 1 IEC 61800-5-2: Safe Stop 1 (SS1) Controlled ramp down, followed by STO EN 60204-1 (VDE 0113): Stop Category 2 IEC 61800-5-2: Safe Stop 2 (SS2) Controlled ramp down, followed by SOS (Safe Operating Stop) 44

On Board Safety Function 45

Base Block Why doesn t the standard baseblock multi-function input satisfy Stop 0 or STO? 46

Evolution of the Base Block Originally base block was hardware that blocked current to the base of bipolar transistor to turn it off during a fault. Control Signal Baseblock is physical hardware AND Control Signal AND Base block 47

Software Base Block Baseblock implemented in software. Baseblock process executed (software) Previous models IGBTs Controller Baseblock signal S4 CPU Output shuts off SC Multi-function (programmable) digital signal input circuit U V W 48

Issues with Software Baseblock Safety Issues with Software Baseblock command. Safety can t be guaranteed for every step in the program. Someone may re-program the baseblock input after all, it is programmable Input scan time can cause delayed response. The controller could malfunction Software bug. 49

EN954-1: the five categories for safetyrelated parts of control systems Category B The basic category --The occurrence of a fault can lead to loss of safety function; Category 1 Improved resistance to faults is achieved predominantly by selection and application of components. This is achieved by using well-tried components and well-tried safety principles. Category 2 Category 1 requirements plus control system is designed so safety-related functions are checked at suitable intervals by the machine control system. After detection of a fault, a safe state will be maintained until the fault has been cleared. Category 3 Improved so that a single fault will not lead to loss of a safety function. Common mode faults need to be taken into account when the probability of such a fault occurring is significant. Whenever reasonably practical, the single fault should be detected at or before the next demand for the safety function. All faults are not required to be detected, thus an accumulation of undetected faults could lead to hazardous situation. Category 4 All faults will be detected and there will the protection against an accumulation of faults which needs to be specified. The safety-related parts of the control need to be designed so the a single fault does not lead to a loss of safety function and the single fault will be detected at or before the next demand for the safety function. This category of safety requires that when faults occur the safety function is always performed and the faults will be detected in time to prevent the loss of the safety function. 50

Safe Disable (Safe Torque off) Back to hardware base block. Safe Disable IGBTs Safety signal input H1 H2 Safety signal input circuit Gate circuit interrupt Output shuts off HC Redundancy 2 inputs ensure that the drive stops, even if one of the inputs is damaged Hardware Implementation Disconnects IGBTs from control circuit directly! No software involved. U V W *Example from A1000 51

Safe Disable in V1000 Safe Disable is triggered as soon as the current between terminals H1 and HC is interrupted. Triggering Safe Disable blocks signals to the output transistors in accordance with safety standards. Power to the motor is cut off, and the motor coasts. The operator display reads Hbb to indicate that Safe Disable has been activated. Safe Disable can be used with both induction motors and synchronous PM motors. Wiring example EN954-1 Cat.3 device H1 HC V1000 Controller V1000 splits this input into 2 separate circuits internally, thus meets the standard under the necessary requirements described in Note1. Power supply Motor *Note that output is shut off within 1 ms. To use the Safe Disable input function, remove the short between H1 and HC (a temporary jumper is placed between the two terminals for shipping). A safety switch or other components for safety that ranks above Cat. 3 in EN954-1 can be added to terminals HC and H1. Note 1 Any enclosures must at least satisfy protective levels defined in IP54. Remove the jumper from terminals used for Safe Disable. 52

Safe Disable in A1000 A1000 has two Safe Disable input terminals and a single monitor output terminal. Safe Disable is triggered by interrupting current to terminal H1 or H2 from HC. Output DM notifies external devices that the Safe Disable feature has been triggered. The user can therefore expand drive capability by adding a device with an External Device Monitor (EDM) input. Wiring example EN954-1 Cat.3 device Safety Controller EDM HC H1 H2 A1000 Controller Power supply To use the Safe Disable input function, remove the short between H1/H2 and HC (a temporary jumper is placed between these terminals for shipping). A safety switch or safety components that rank above Cat. 3 in EN954-1 can be added to terminals HC and H1 & H2. DM+ Never short the terminals used for Safe Disable. DM- Feedback Loop Mtr 53

Category 1 Safe Disable Run/stop with use of well tried components and safety principles Interlock (door,gate) stop Drive Controller Power Power supply supply run K1 H1 motor 54

Category 3 Safe Disable Single fault must not lead to the loss of the safety function Category 3 by Two Safety inputs of Drive 55

Lift Example The benefits of the Safe Disable feature differ by the type of application, as safety requirements vary by the type of machinery. No longer needed The two contactors on the output side can be reduced to a single switch. EN954-1 Cat.3 device AC Drive Motor Lift application Note that a safety switch in compliance with EN954-1 Cat. 3 is required. EN81-3: Safety regulations for lift applications (Part 3: Industrial hydraulic lifts) EN115: Safety standards for escalator and moving walkway installations EN201: Engineering safety requirements for the design and construction of plastic and rubber injections molding applications. 56

F7 Option For the customer who just can t wait for the A1000 Special F7 with Safe Disable Requires special Control Board & special I/O Board 57

F7 Option Run Fwd Run Rev H1-01 = 24 (Ext Flt) H1-02 = 14 (Clr Flt) H1-03 = 03 (Ref Sel 1) H1-04 = 04 (Ref Sel 2) H1-05 = 06 (Jog Ref Sel) H1-06 = 08 (Ext Base Blk) BB = Hardware Base Block BB1 = Hardware Base Block 3.3KΩ Fault Relay (Running) 0 = H2-01 (at Zero Spd) 01= H2-02 (at Set Spd) 02= H2-03 Safe-Off Terminals N.C. N.O. N.O. N.O. N.O. + - 24VDC (Isolated) +15VDC @ 20mA max F7 Safe-Off Control Board S1-2 250Ω Auto Ref (Output Freq) 02 = H4-01 H3-05 = 02 (Manual Ref) (Output Current) 03= H4-04 H3-09 = 0 (Freq Cmd A1 Bias) 3KΩ H6-01 = 0 (Freq Ref) 2KΩ +15VDC (Output Freq) 02= H6-06 47Ω -15VDC @ 20mA max Chassis (Heatsink) Ground AC = 0V Analog Common Iso + - + RS485 /422 - S1-1 110Ω 58

F7 Wiring EN954-1 Category 3 Safety Device W 4 W 3 W 2 Run Fwd Run Rev H1-01 = 24 (Ext Flt) H1-02 = 14 (Clr Flt) H1-03 = 03 (Ref Sel 1) H1-04 = 04 (Ref Sel 2) H1-05 = 06 (Jog Ref Sel) H1-06 = 08 (Ext Base Blk) BB = Hardware Base Block BB1 = Hardware Base Block 3.3KΩ W 1 + - 24VDC (Isolated) 59

F7 Physical Terminals 60

The End Any Questions? Functional Safety Remember A Drive is only a Component in the Safety System. Its only responsibility is to turn off the motor when a Safe-Disable input is opened. 61