FUNCTIONAL SAFETY MANUAL

Similar documents
FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

FUNCTIONAL SAFETY MANUAL

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

SAFETY MANUAL. UltraSonic IS-5 Ultrasonic Gas Leak Detector

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

SAFETY MANUAL. FlameGard 5 MSIR Multi-Spectral Infrared Flame Detectors

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

U L T R A S O N I C G A S L E A K D E T E C T O R

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

FlameGard 5 UV/IR HART

Proservo NMS5- / NMS7-

FlameGard 5 MSIR HART

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Certificate of Compliance

ULTIMA X5000. MSAX5000.com

S5000 Gas Monitor. GMS5000.com

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Dependable Solutions for Gas Detection

Functional safety manual Liquiphant M/S with FEL57 and Nivotester FTL325P

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Dräger Flame 2500 Flame Detection

Safe Operation Manual. Honeywell IQ Force Gas Detector

GAS DETECTORS. When every second counts

Controllers. Instruction Manual WARNING

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Instruction Manual WARNING

User s Manual. YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters. Manual Change No

Model D12-IR. Digital Gas Transmitter...

GASSONIC Ultrasonic Gas Leak Detection. How fast does your Gas Detection System detect leaks? Because every life has a purpose...

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

Danfoss gas detection unit Type GD Heavy Duty

Ultrasonic Pressurized Gas Leak Detector User Operation Manual

Certificate of Compliance

Functional Safety Manual Oil Leak Detector NAR300 System

Operating Manual MS220KA and MSR220KA

Dräger Polytron 7000 Fixed gas detector

Dräger Flame 2100 Flame Detection

Ultrasonic Gas Leak Detection

GasGard 100 Control System

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions!

SUPREMATouch Modular Fire & Gas Detection System

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Autronica Fire and Security AS ID:

Operating Manual MS220DA

Incus Ultrasonic Gas Leak Detector Wide Area Coverage for Pressurized Gas Leaks

FUNCTIONAL SAFETY CERTIFICATE

Remote Relay Module (RRM)

GM Ultrasonic Gas Leak Detection Gas Detection at the Speed of Sound. How fast does your Gas Detection System detect leaks?

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Sintrol Snifter A2 EX. Manual. Version 1.2.3

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

AUR300C. Advanced Ultraviolet Burner Controller

The SharpEye 40/40I (IR3) Flame Detection

Multi-Gas-Controller MGC2

PPA Michaël GROSSI - FSCE PR electronics

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

United Electric Controls One Series Safety Transmitter Safety Manual

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Dräger Polytron 5100 EC Detection of toxic gases and vapors

SUPREMATouch. Modular Fire & Gas Detection System

Certificate of Compliance

Dräger Polytron Pulsar 2 Open Path Gas Detector

GAS PLUS ALARM SYSTEM

Design Manual Installation Operation Maintenance

Dräger Flame 2500 (IR3) Flame Detection

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Failure Modes, Effects and Diagnostic Analysis

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Model IR4000M. Multi-Point Monitor. Instruction Manual 12-10

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Operations Manual GMA 313 CO 2. Gas Monitor for one detection point

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700S

MSA Fixed Gas & Flame Detection for the Automotive Industry

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

QD6310. Fixed Gas Detector Operation Manual

GasAlertMicroClip X3 Specifications

Dräger Flame 2700 (Multi-IR) Flame Detection

STEAMPAK Series BurnerPAK BMS Burner Management Systems

Failure Modes, Effects and Diagnostic Analysis

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Soliphant M with electronic insert FEM52

Dräger Polytron 8000 Stationary gas detector (EC)

SIL Safety Guide Series MS Single-Acting Spring-Return Hydraulic Linear Actuators

Deltapilot S FMB70. Functional Safety Manual. Level and Pressure Measurement with Output Signal ma

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Session Ten Achieving Compliance in Hardware Fault Tolerance

SUPREMATouch. Modular Fire & Gas Detection System

Fisher LCP100 Local Control Panel

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

Digital EPIC 2 Safety manual

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

OPTIBAR DP 7060 Supplementary Instructions

Dräger Polytron 8200 Stationary gas detector (CatEx)

Transcription:

FUNCTIONAL SAFETY MANUAL UltraSonic EX-5 Ultrasonic Gas Leak Detector The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by MSA. Instruction Manual MSA reserves the right to change published specifications and designs without prior notice. Part No. MANEX5SAFETY Revision 0

The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by MSA. MSA reserves the right to change published specifications and designs without prior notice. This manual describes the functional safety related information for the installation, operation, configuration, and maintenance of the UltraSonic EX-5 ultrasonic gas leak detector. This manual does not describe installation requirements in hazardous locations. For complete information regarding performance, installation, operation, maintenance, and specifications of the UltraSonic EX-5, please refer to the product instruction manual. It is MSA s mission to benefit society by providing safety solutions through industryleading products, services, and systems that save lives and protect capital resources from the dangers of hazardous flames, gases, and vapors. The safety product you have purchased should be handled carefully, and installed and maintained in accordance with the associated product instruction manual. Remember, this product is for your safety. WARNING: TOXIC, COMBUSTIBLE, AND FLAMMABLE GASES AND VAPORS ARE VERY DANGEROUS. USE EXTREME CAUTION WHEN THESE HAZARDS ARE PRESENT. 2

INTRODUCTION General Description The UltraSonic EX-5 is a microphone based ultrasonic gas leak detector that detects gas leaks by sensing the airborne ultrasound emitted from leaking gas at high pressure and responds with a 4-20 ma analog output, proportional to the acoustic sound pressure level (SPL) in db, or optional relay output. Ultrasound emitted from a gas leak is not affected by wind direction or diluted as is a gas cloud. This makes the UltraSonic EX-5 the optimal choice for instant and reliable fixed gas leak detection in outdoor applications. The UltraSonic EX-5 is regarded as a Type B field device per IEC 61508. The safety function of the UltraSonic EX-5 does not include: RS-485 or Modbus digital communication HART communication RS-485, Modbus, and HART communication are typically used for field device setup, diagnostics, and troubleshooting. Carefully observe requirements for interfacing in hazardous locations. RS-485, Modbus, and HART communication are non-interfering functions and do not interrupt the safety critical function of the detector. 3

INSTALLATION NOTE: Power should remain disconnected until all other wiring connections are made. For complete information on the installation of the UltraSonic EX-5 acoustic detector refer to the product instruction manual. Installation and Maintenance must be carried out by suitably skilled and competent personnel only. Before opening and working on the UltraSonic EX-5 in hazardous locations, be sure that power is off. Install and maintain all hazardous area equipment in accordance with the relevant regulations and practices of the country concerned. Detector Location Considerations The UltraSonic EX-5 Detector does not have to be in contact with the leaking gas itself. It will detect the gas leak instantly even if the gas is carried away by wind or diluted in the air. However, factors that should be considered when locating an acoustic detector are Background noise levels Correct mounting Physical obstructions Additionally, the unit should be mounted free from shock and vibration and convenient for visual inspection and cleaning. Though the detectors are RFI resistant, they should not be located near radio transmitters, high magnetic or electrical fields, or in areas with similar interference. No special or additional detector mounting, wiring, power, or tool requirements exist beyond the standard installation practices documented in the product instruction manual for the UltraSonic EX-5. WARNING: The inner six screws for the UltraSonic EX-5 should not be unscrewed and the bottom compartments should not be opened. The warranty will be void if the bottom part is opened. 4

OPERATION AND MAINTENANCE For complete operation, configuration, and maintenance information for the UltraSonic EX-5 acoustic detector refer to the product instruction manual. Before connecting a unit, check to make sure power is turned off. Before power up check all wiring connections. The UltraSonic EX-5 performs internal diagnostics on critical faults every two seconds, an acoustic self-test every 15 minutes, and a memory check every 24 hours. Upon detection of a fault the unit will respond with tripping the fault relay and outputting fault level analog output current per Table 2, below. Upon the detection of an acoustic fault the detector trips the fault relay and outputs an analog output pulse for 5 seconds per Table 2. After the pulse the unit returns to normal detection mode and is able to detect gas however, the detection capability may be reduced due to the acoustic fault. Refer to the product instruction manual for suggestions to clear the fault. NOTE: During the acoustic self-test the unit is off-line for 8 seconds. In the unlikely event that an acoustic fault occurs immediately after the acoustic test, indication of this fault will occur 16.5 minutes later, at the completion of the next acoustic test. High readings of ultrasonic sound level may indicate an explosive concentration of gas at the sensor. A subsequent fall in the ultrasonic sound level does not imply that safe working conditions have been restored. The UltraSonic EX-5 is tested and calibrated as part of the manufacturing process. However, prior to use, it is good practice to establish and follow a regular maintenance schedule. This can be done using the UltraSonic test and calibration unit. Carefully follow test and calibration procedures described in this section of the product instruction manual. Refer to the Troubleshooting Section in the product instruction manual in the event of a fault condition. In addition, spare parts should be on-hand to maintain the four hour repair time. Refer to the Replacement Parts section of the instruction manual for more information. 5

SPECIFICATIONS Table 1 and Table 2 list specifications for the UltraSonic EX-5. For a complete list of specifications refer to the UltraSonic EX-5 product instruction manual. UltraSonic EX-5 Instruction Manual P/N Operating Temp Range: Humidity Range: Input Power: MANEX-5-40 C to 60 C 0 to 100% RH 15 VDC 36 VDC Vibration sensitivity: 0.13 m/s² perpendicular to the membrane will trigger the unit in the most sensitive range (44dB SPL) Table 1 Environmental/Electrical Specifications Analog Output Level UltraSonic EX-5 Mode 0 ma Start Up 0, 1.25 ma, or 3.5 ma Fault 1 ma, 1.25 ma, or 3.5 ma pulse for 5 seconds Acoustic Error 3.0 ma or 3.5 ma Set Up 4 20 ma 58 104 db > 20 ma Over range Table 2 Analog Output Specifications for the UltraSonic EX-5 (600Ω Max) 6

CERTIFICATIONS AND FAILURE RATE DATA The UltraSonic EX-5 has gone through rigorous reliability and functional safety assessments, which have resulted in the acoustic detector being certified to IEC 61508 Parts 1, 2, and 3, by FM Approvals. The reliability assessment is a failure rate prediction that assumes an average temperature of 40ºC and an environmental factor equivalent to Ground Fixed. It is assumed that the detectors will be installed in a Safety Instrumented System operating in a Low Demand environment per IEC 61508. Table 3 lists the SIL parameters for the UltraSonic EX-5. Parameter UltraSonic EX-5 Analog Output (Source) UltraSonic EX-5 Analog Output (Sink) UltraSonic EX-5 Relay Output FM Certificate 3044405 3044405 3044405 Mean Time Between Failure (MTBF) 13 years 13 years 13 years λ DD (Fails per hour) 4.07E-6 4.17E-6 4.03E-6 λ DU (Fails per hour) 6.12E-8 6.16E-8 2.88E-7 SFF >99% >99% 97% SIL* 3 3 2 Diagnostic Test Interval Typical Response Time 2 seconds (critical faults) 15 minutes (acoustic self-test) 24 hours (memory check) <1 second** PFDavg1oo1*** 2.85E-4 2.86E-4 1.28E-3 Table 3 SIL Parameters for UltraSonic EX-5 * Hardware Fault Tolerance = 0 ** Does not include user-selectable delays *** PFDavg1oo1 assumes a 4 hour repair time and 1 year proof test interval. Agency Approvals The UltraSonic EX-5 is certified by ATEX, IECEx, FM, CSA and IEC 61508 (per FM Approvals) 7

MINE SAFETY APPLIANCES COMPANY CRANBERRY TOWNSHIP, PENNSYLVANIA, USA 16066 1-800-MSA-INST www.msanet.com