International Journal of Advancements in Research & Technology, Volume 2, Issue 8, August ISSN

Similar documents
Failure Mode Effect Analysis in a Frying Pan Manufacturing Industry

Trouble Shooting Guide FAA, 3-phase (D3631)

Trouble Shooting Guide RAA, 1-phase (D3627)

Trouble Shooting Guide PAA, 1-phase (D3731)

Trouble Shooting Guide PWA, 3-phase (D10571)

REFRIGERANT ON-VEHICLE INSPECTION AC 14

CENTRAL, SPLIT SYSTEM REFRIGERATED AIR-CONDITIONING INSPECTION INTERIOR

Preventative Maintenance Tables

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

Guide To Troubleshooting INEFFICIENT COOLING FANS

T-Series Air Conditioner T20 Model

OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

T-Series Air Conditioner T53 Model

T-Series Air Conditioner T15 Model

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Fabrication of Hot and Cold Water Dispenser

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Beverage Air IMPORTANT

- 1 - Updated on 18 March, 2010

- 1 - Updated on 18 March, 2010

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Quest Dry 105, 155, and 205 Dual

TROUBLESHOOTING VANGUARD

Quest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

38ASB/CCARS240~600 (036~060) AIR-COOLED CONDENSING UNIT

A/C-HEATER SYSTEM - MANUAL

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

SUBJECT Model ASH218SV-C8LU SPECIFICATION ASH218SV-C8LU. 1. SCOPE This specification is applied to SHANGHAI HITACHI rotary compressor.

CC Series VACUUM PUMPS

DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931)

REFRIGERANT RECOVERY Log Book

TABLE OF CONTENTS FOR YOUR SAFETY

RSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs

Product Information and Technical Guide

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

RPI Industries, Inc.

TROUBLESHOOTING TROUBLESHOOTING. Indoor unit EEPROM parameter error. Indoor / outdoor units communication error. Zero-crossing signal detection error

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location

Commercial Maintenance Agreement (CMA) Benefits

SERVICE MANUAL FOR ROOF TOP AIR CONDITIONERS

SXY MAINTENANCE SECTION M-1

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

OPERATION AND MAINTENANCE INSTRUCTIONS FOR SERIES ROOF TOP HEAT PUMPS AND CEILING PLENUMS

SYLLABUS. DIVISION: Business & Engineering Technologies REVISED: Spring CURRICULA IN WHICH COURSE IS TAUGHT: Automotive Analysis and Repair

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Room Air Conditioner Service and Parts Manual

PART-A, ANNUAL MAINTENANCE CONTRACT FOR PLANT 1 PACKAGE AIR CONDITIONER UNITS. SOR No Description of Services Qty UOM

The breaker trips at once when it is set to ON. The breaker trips in few minutes when it is set to ON.

NUMBER: ISSUED: JULY 13, /336 73/23 STACKABLE CRESCENT CUBER KM-1300SWH-E SERVICE MANUAL FOR QUALIFIED SERVICE PERSON HOSHIZAKI

Troubleshooting & Reference

EXPERIMENTAL VERIFICATION OF PERFORMANCE OF CAPILLARY TUBE USING VAPOUR COMPRESSION REFRIGERATION SYSTEM

442 Chapter 16. Figure 16-5 Gas leak detection

Quest 105, Dry155, and 205 Dual

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

The Saturation process

ERROR CODES R22 & R407C Units Black = All Units Red = 4, 5, 6 & 7 Series Blue = 8 Series Green = KX / KX2 / KXR

Important Facts You Should Know About Your Heat Pump (602) or (520)

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

BMG-HGP & BMG-SLP Model Bottom Mounted Full-Length Glass Door Refrigerator Merchandisers

TROUBLESHOOTING GENERAL TROUBLESHOOTING PROBLEM PROBABLE CAUSE CORRECTIVE ACTION

A Review of Hydronic Balancing of Cooling Water Circuit

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

PHOENIX 200 MAX. 1 Specifications. 2 Operation. Therma-Stor Products. Phoenix 200 Max Operation & Service Instructions

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

KM-630MAF KM-630MWF KM-630MRF

USER'S MANUAL PGE Single Package Rooftop

Installation & Operations Manual for. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers. 4/17 Rev.

Refrigeration System with a Capillary Tube and a Thermostat

CWS AIR-CONDITIONERS

Service Manual. Commercial Series Refrigerated Kitchen Equipment Models Undercounter Worktop Prep Table. hoshizakiamerica.com

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Air-Conditioning Buying Guide

Transcription:

International Journal of Advancements in Research & Technology, Volume 2, Issue 8, August-2013 235 Application of Reliability Analysis for Validating the Results obtained by Failure Mode and Effects Analysis for Air Conditioner Mrs.Reena Pant 1, Dr. V. Venkatraj 2 1 (Mrs.Reena Pant) Mechanical Engineering, Bharati Vidyapeeth College of Engineering, Navi Mumbai, India.,; 2 (Dr.V.Venkatraj), Former Professor, Bharati Vidyapeeth College of Engineering, Navi Mumbai, India. Email: reenapant7@gmail.com ABSTRACT Failure Mode and Effects Analysis (FMEA) is a means of identifying the probable threats a product may phase and how to prevent them so that the product can be made reliable for the customers. Reliability Analysis gives the confidence to the manufacturer about the success of the product in the market. Giving a reliable product in the market establishes the reputation of the company. In this paper an effort has been made to calculate Risk Priority Number (RPN) for conducting the FMEA for Air Conditioners used for domestic purposes. The Reliability Analysis, which follows the FMEA, is performed to establish the recommendations of FMEA. Keywords: Failure Mode and Effects Analysis, Reliability, Risk Priority Number. Product reliability is an indicator that the product will per- 1 INTRODUCTION Introduction: form satisfactorily over its intended useful life when operated Failure Mode and Effects Analysis (FMEA), is a group of activities intended to recognize and evaluate, the potential failure turers. From a customer perspective, poor product reliability normally. It is of great interest to both customers and manufac- of a product or process and its effects, and to identify actions increases the frequency of failures and implies higher maintenance costs over the life of the product. From a manufacturer that could eliminate or reduce the chance of the potential failure occurring. perspective, poor reliability affects sales through customer FMEA is an analytical technique (a paper test) that combines dissatisfaction, results in higher warranty costs, and affects the the technology and experience of people in identifying foreseeable failure modes of a product or process and planning for uct to perform satisfactorily can have safety implications reputation and the bottom line. Often, the inability of a prod- its elimination. FMEA is designed to assist the engineers to (Murtey D.N..P.). Sometimes equipment failure can have a improve the quality and reliability of design. FMEA provides major impact on human safety and/or health. Automobiles, the following benefits. They are: planes, life support equipment, power generating plants are a few examples (Engineering Statistics Handbook). Improve product/process reliability and quality 2 METHODOLOGY Increase customer satisfaction 2.1 For the development of FMEA Early identification and elimination of potential product/process failure modes Prioritize product/process deficiencies and their elimination Emphasizing problem prevention Documenting the risk and the actions taken to reduce risk Minimizing changes at later stages and associated cost [Besterfield D.H. et al.] Air conditioners work on the simple principle of refrigeration that is Liquids absorb heat when changed from liquid to gas Gases give off heat when changed from gas to liquid. The air conditioners use the cycle of compression, condensation, expansion, and evaporation in a closed circuit. The same refrigerant is used to move the heat from one area, to cool this area, and to expel this heat in another area. 2.2 Possible Failure Categories in Air Conditioner: The possible failures in an Air Conditioner are grouped into

International Journal of Advancements in Research & Technology, Volume 2, Issue 8, August-2013 236 the following categories: Refrigeration System Condensed Air Evaporator General Electrical Systems The possible failures in each of the above categories are listed below. Possible failures in Refrigeration System Refrigerant Shortage Refrigerant Overcharge Presence of non condensables Restrictions Capillary Tubes Strainers Inefficient Compressor Frosted inside coil Frosted outside coil Possible failures in Condensed Air Low ambient temperature High ambient temperature Obstructed coil Inoperative fan Motor Slow fan Motor Fan motor reversed Poor location Faulty Installation Possible failures in Evaporator Obstructed air filter Room too large Obstructed coil Grills mis-directed Poor location Air leak Possible General Failures: setting Switch setting Sound level Possible general Installation Failures Improper Mounting Improper location Possible failures in Electrical Systems Switch Overload relay Compressor capacitor Compressor motor Fan motor capacitor Fan motor The probable defects which may cause the failures in the system or subsystem of AC are broadly classified, for the study purpose, into seven categories: 1. Compressor and fan motor defects 2. Condenser defects Claims 3. Choked Capillary 4. Starting Capacitor failure 5. Starting Relay failure 6. Strainer choking 7. failure The next step in the study was the field visit, to collect the data of failure of ACs for the above mentioned seven categories of failures. The service centers in Mumbai and Navi Mumbai are visited for the purpose. The record book of the service station is referred and the maintenance works of last fifteen days were observed. During this period, if the report of failure was available for the selected seven subsystems then details of the record were observed by finding the answers of the following questions. What is the problem? (Not working/not cooling properly/ Noisy operation/ Other) Which component failed? (Compressor/Condenser defects/capillary/starting Capacitor/Starting Relay /Strainer /) Why it has failed? Is it being repaired or replaced? All the observations were based on the possible failure categories and the components used in the study. The same process is repeated at every service station and total 1720 observations were made. This work is carried out in the months of April and June 2010. The data is summarized in the following table. Table 1: Data collection from service stations- categorization for FMEA Components No. of Per- Ran cent Compressor and Fan Motor Defects 289 16.80 2 Condenser Defects 829 48.19 1 Capillary Choked 101 5.87 6 Starting Capacitor failure 136 7.91 4 Starting Relay failure 111 6.45 5 Strainer Choking 197 11.45 3 Failure 55 3.19 7 Total 1720 100 king The data shows that the highest number of defects occur in the Condenser, followed by the Compressor. The failures of strainer are ranked third and likewise other defects have been allotted the ranking based on the collected data. This ranking is further used for the calculation of Risk Priority Number in Failure Modes and Effects Analysis charts.

International Journal of Advancements in Research & Technology, Volume 2, Issue 8, August-2013 237 2.3 Development of Failure Modes and Effects Analysis chart The next step in the study is the development of FMEA Chart. For each defect classified earlier, the causes of potential failure modes and their effects are recognized. For every cause, the possibility of Detection at the design stage is recognized. Similarly for every effect the Severity of its happening is found out. The data collected through service station is used as Occurrence of the failure mode. The Risk Priority Number (RPN) is obtained by multiplying the values of Severity, Detection and Occurrence. For example, for the component strainer, the chances of detection of the potential cause of failure, worn out particles is very remote during the design stage, therefore a value of 9 is given to detection. The effect of this cause is choked capillary and it has very high ranking when potential failure mode affects safe operation and failure occurs with warning. The value of 9 is assigned for such severity. The value of occurrence of failure is 9 for the strainer as per the data collected from the service station. Therefore RPN comes out to be equal to 9*9*9=729. Table No. 2 shows the FMEA for strainer and RPN calculations for reference. In the similar manner FMEA has been carried out for all the seven components. The Table No.3shows the various possible causes of failure and their RPN is shown in descending order. 2.4 Conclusion drawn from FMEA: The Risk Priority Numbers obtained in the FMEA shows that the particular causes of failure should be taken care of during the design stage. For this certain recommendations are sug- gested. These recommendations are to be validated by the people working in the field for reliability analysis. 3. Reliability Analysis To perform the reliability analysis the opinions of experts are collected for the recommendations suggested during FMEA, with the help of a questionnaire. Following questionnaire shows the recommendations made by FMEA and the response of experts. 3.1 Calculation for Reliability Improvement Factor: The data obtained in the survey is utilized for calculating the reliability Improvement Factor. For the calculation first of all the failure rate for each component is calculated. It is taken as number of times the component has failed by the average life of the component (Obtained from the survey results). Then it is multiplied by Yes value. Now the summation of Failure rates of all the components is obtained. The improvement factor is calculated as the ratio of difference of total Failure Rate and component failure rate and total failure rate. Theoretically the improvement value should be more than one and in the study also the improvement factor for all the recommendations made for various causes of failure results to be more than one. 4. Conclusion: To increase the reliability of the product the rate of failure is to be minimized, so that the working life hours can be increases. In this study also the reliability improvement factor for the recommendations for various causes of failure recognized by the Failure Mode and Effects Analysis, is obtained more than one. Hence, it can be concluded that recommendation will definitely help in reducing the Risk Priority Number. REFERENCES [1] Besterfield D.H. et al., Total Quality Management, Seventh Indian Reprint,2005,Pearson Education. [2] Murtey D.N.P. Reliability of Product, http://www.ntnu.no/ross/books/prodrel [3] Engineering Statistics Handbook, Safety and Health Considerations

International Journal of Advancements in Research & Technology, Volume 2, Issue 8, August-2013 238 Strainer Item/Function Potential Failure Mode Potential Effects of Failure Severity (S) Potential Cause/Mechanism of Failure Occurrence (O) Detection (D) Risk Priority Number (RPN) =S*O*D To absorb moisture To Collect dust particles Fails to absorb moisture Choke up No cooling effect 8 Presence of impurity prevents flow of refrigerant 9 Too much moisture in refrigerant 5 360 Dust particles in 9 refrigerant 9 729 Worn out particles from the compressor parts 9 729 Table No.2

International Journal of Advancements in Research & Technology, Volume 2, Issue 8, August-2013 239 Sr.No. Potential Failure Mode Part in which occurs RPN 1 Dust particles in refrigerant Strainer 729 2 Worn out particles from the compressor parts Strainer 729 3 Poor Installation Condenser 720 4 Dirty fan blades Condenser 560 5 Dirt on coil Condenser 480 6 Reduced air quantity Condenser 480 7 Electrical Problems Starting Capacitor 448 8 Restricted air inlet and outlet Condenser 400 9 Too much moisture in refrigerant Strainer 360 10 Motor windings are weak Starting Capacitor 336 11 Fails to provide starting torque Starting Capacitor 280 12 Motor does not start at all Starting Capacitor 280 13 Internal springs get stuck 252 14 not kept in proper position 252 15 Arcing results in contact getting welded 224 16 Carbon deposits on contact surface 216 17 Continuous Running Compressor and Motor Defects 216 18 Corrosion Starting Relay 192 19 No Servicing of Motor Compressor and Motor Defects 192 20 Circuit Problem 160 21 Incorrect rotation of fan Condenser Defect 160 22 Oil in the refrigerant Capillary Tube 160 23 Loose Connection Compressor and fan motor defects 144 24 Frequent Starting and Stopping Compressor and fan motor defects 128 25 Fan Capacitor Weak Compressor and fan motor defects 112 26 Excess load on relay Starting Relay 108 27 Pitting of contact surfaces 108 28 Winding of relay gets overheated. Starting Relay 96 29 No Varnishing of Motor Compressor and Motor defects 72 30 Shaft Balance and Bearing Problem Compressor and Motor defects 72 31 Insulation Defects Compressor and Motor defects 56 32 Incorrect selection of Capillary bore and length Capillary Tube 40 33 Design Problem 28 Table 3: Risk Priority Number in descending order

International Journal of Advancements in Research & Technology, Volume 2, Issue 8, August-2013 240 Table No.4 Questionnaire for Survey of Reliability Analysis, with Opinion Sr.No. Particular Description I Type Window Split 100 100 II Brand Brand 1 8 38 Brand 2 10 36 Brand 3 4 6 Brand 4 6 10 Brand 5 6 4 Brand 6 6 4 Brand 7 8 2 Brand 8 52 0 III Approximate less then 1yr 2 12 date of installation of the AC: less than 2 yr 14 14 less then 3 yr 52 40 less then 4 yr 22 22 less then 5 yr 4 4 less then 6 yr 4 4 less then 7yr 2 4 Annual Maintenance Contract is there Yes 17 36 No 83 64 IV First indication of failure as reported by the customer Inoperative 6 14 Overheating 16 4 Burning Smell 18 6 No Cooling 18 40 Noisy Operation 28 8 Other 14 28

International Journal of Advancements in Research & Technology, Volume 2, Issue 8, August-2013 241 V Name of the part which failed Compressor and fan motor 26 28 Condenser 30 34 Choked Capillary 4 3 Starting Capacitor 14 10 Starting Relay 10 8 Strainer 14 16 2 1 VI Status of the part New 92 82 Repaired 6 14 Replaced 2 4 VII Reason of Failure 1 Dust particles in refrigerant (Strainer) 3 6 2 Worn out particles from the compressor parts (Strainer) 4 2 3 Too much moisture in refrigerant (Strainer) 7 8 4 Poor Installation (Condenser) 7 9 5 Dirty fan blades/ (Condenser) 9 10 6 Dirt on coil (Condenser) 9 10 7 Reduced air quantity (Condenser) 5 5 8 Electrical Problems (Starting Capacitor) 6 5 9 Motor windings are weak (Starting Capacitor) 2 2 10 Fails to provide starting torque (Starting Capacitor) 1 1 11 Motor does not start at all (Starting Capacitor) 5 2 12 Continuous Running (Compressor) 5 8 Loose Connection (Compressor) 13 9 10 14 Frequent Starting and Stopping (Compressor) 7 6 15 No Varnishing of Motor (Compressor) 3 1 Insulation Defects (Compressor) 16 2 3 Excess load on relay (Starting Relay) 17 5 4 18 Winding of relay gets overheated (Starting Relay) 5 4 19 Oil in the refrigerant (Capillary Tube) 4 3 20 Other 2 1 100 100

International Journal of Advancements in Research & Technology, Volume 2, Issue 8, August-2013 242 Table 4 B: Expert Elicitation Sr. No. Particular Probable Action Comment Yes No 1 Dust particles in refrigerant In house cleaning before installation; Changing the refrigerant 100 if required during maintenance 2 Worn out particles from the compressor parts Electromagnet at the outlet of compressor 88 12 3 Too much moisture in refrigerant Evacuating the system before filling the refrigerant and performing 65 35 chemical analysis to check the level of moisture. 4 Poor Installation Self locking lever system to maintain straight upright position. 78 22 5 Dirty fan blades Dual operating fan to 6 Dirt on coil operate the fan as 81 19 blower also. 7 Reduced air quantity Condenser leakage is to be rectified 88 12 8 Electrical Problems Reducing the back 9 Motor windings are weak pressure by delay switch will help in effective functioning. 10 Fails to provide starting torque 11 Motor does not start at all 82 18

International Journal of Advancements in Research & Technology, Volume 2, Issue 8, August-2013 243 12 Continuous Running Leakage problem of condenser leads to continuous running of the compressor. If leakage is rectified the condenser problem will be solved automatically 13 Loose Connection When unit is maintained at straight upright position the vibrations will be reduced without affecting the connections 14 Frequent Starting and Stopping Delay start switch to regularize the pressure of the compressor so that back pressure is reduced in the system. 63 37 68 32 73 27 15 No Varnishing of Motor New varnishing materials are available with more affinity to material 80 20 and to make the sur- face smoother. 16 Insulation Defects Secondary and tertiary coatings are recommended 62 38 17 Excess load on relay Delay start switch 18 Winding of relay gets overheated. Delay start switch will reduce the back pressure therefore overheating of the windings 19 Oil in the refrigerant Evacuation and chemical analysis 74 72 26 28