film flow, ultrasonic, and microwave. The engineering development effort builds upon the

Similar documents
Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Fred Rodgers Magnet Academy 501 College Avenue Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For:

Performance Optimization of the Evaporative Condenser Design

Radon Measurement Survey Report. Waldo Middle School 56 Jackson Street Aurora, Illinois Prepared For:

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

ABSTRACT FOR AARST CONFERENCE OCTOBER 1990 INSTRUMENTATION FOR RADON MEASUREMENT AND DIAGNOSIS

OPTIMISE VACUUM TO IMPROVE PLANT PERFORMNCE

MODEL AND SIMULATION OF DEEP-BED CLOVE DRYING: EFFECT OF FERMENTED TREATMENT

Metal hydride storage system for MICE experiment at Rutherford Appleton Laboratory. Technical specification.

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

Radon Reference Facility at Bowser-Morner, Inc. AMUG Meeting Las Vegas May 4, 2010 Phillip H. Jenkins, PhD, CHP

COMPACT ADSORPTION CHILLERS WITH COATED ADSORBER HEAT EXCHANGERS

HOW TO SELECT AN INDIRECT THERMAL TECHNOLOGY FOR INDUSTRIAL MATERIALS PROCESSING

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Eliminating Condensation and Resulting Corrosion. Sulphur Tail Gas and De-Gas Lines

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Adsorption Chillers Energysmart Green Cooling

Prepared by Technical Team

ecodry Figure 1 - Process Diagram ecodry B General Process Description

Brine Generation Study

Adsorption refrigeration system using waste heat

Understanding Process Vacuum for Process Improvement

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager

Meteorology 432. Hygrometry Spring 2013

EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER

Drying principles and general considerations

Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

Fike set out to develop a better understanding of the power density trends in data centers around the world.

Optimization of Hybrid Noncondensable Gas Removal System for a Flash Steam Geothermal Power Plant

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Quality and Technology - Made in Germany -

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

HEAT EXCHANGERS. Heat exchangers are broadly classified based on the following considerations.

POWER TRANSFORMER OIL PROCESSING SPX TRANSFORMER SOLUTIONS, INC.

DROP-IN EVALUATION OF REFRIGERANT 1234YF IN A RESIDENTIAL INTEGRAL HEAT PUMP WATER HEATER

Experimental Study on Waste Heat Recovery from the Pyrolysis Stack using Heat Pipe

HYBRID GAS HEAT PUMP WATER HEATER WITH THERMAL EFFICIENCY 120% 23rd World Gas Conference, Amsterdam Main Author. Atsuya Tajima Japan

6 th Pipeline Technology Conference 2011

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA

Modelling the Performance of a Diffusion Absorption Refrigeration System

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

High Performance Diesel Fueled Cabin Heater. Abstract

Heat Transfer in Evacuated Tubular Solar Collectors

Techniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

THERMAL ENGINEERING LABORATORY II. To train the students with principles and operation of thermal Engineering equipments.

Guide for Radon Measurements in Residential Dwellings (Homes)

A STUDY ON THE BEHAVIOR OF STEAM CONDENSATION IN U-SHAPED HEAT TUBE

Specialized in the design and the tailor-made production of dryers, coolers and thermal processing equipment for industrial use.

Thermal Performance of a Loop Thermosyphon

SBS5311 HVACR II Experiment 2: Analysis of the Combined Rankine and Vapour Compression Cycle

Liquid Ring Vacuum Pumps, Compressors and Systems

THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

Radon Detection Specialists, Inc. Love the Lungs You re With

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

Regenerator Design for Open Cycle Liquid Desiccant Systems Theoretical and Experimental Investigations

Vacuum Booster for Distillation Process

MASS. MARITIME ACADEMY

Efficiency of Application the Condensing Heat Utilizers in the Existing Boiler's Unit in Heat Power Station

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

COOLING SYSTEMS FOR CONTINOUS GALVANIZING LINE Miroslav Raudensky a, Milan Hnizdil a, Jaroslav Horsky a, FrédéricMarmonier b

Study and Design Considerations of HRSG Evaporators in Fast Start Combined Cycle Plants. Govind Rengarajan, P.E.CEM, Dan Taylor

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

Effect of operating conditions on performance of silica gel-water air-fluidised desiccant cooler

HEAT PIPES

A Liquid Desiccant System for Solar Cooling and Dehumidification

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Improving Productivity, Quality and Security

Sensitivity to Thoron on Passive Radon Detectors

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

Active Dry Air Venting for Water Contamination Control

CRAWL SPACE MOISTURE CONTROL - A Fundamental Misunderstanding By Peter Carpenter, member ASHRAE, SBCCI

Measurement Devices. Topic 5 - Audio 56

A study on performance improvement of corrugated type total heat exchanger considering the structure of flow passage on surface

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

EVALUATION OF A LIQUID DESICCANT AIR CONDITIONING SYSTEM WITH SOLAR THERMAL REGENERATION

Drying Parawood with Superheated Steam

Safety by Design. Phone: Fax: Box 2398, RR2, Collingwood, ON L9Y 3Z1

Figure 1-1 Furnace Front Elevation

15. Heat Pipes in Electronics (1)

Vacuum Packages and Central Systems

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

Environmentally safe techniques in the recycling of mercury-containing materials

LABORATORY STUDY ON THE CONSOLIDATION SETTLEMENT OF CLAY-FILLED GEOTEXTILE TUBE AND BAGS

THERMAL PROCESSING THEORY

Transcription:

9. e,.-..- n FLUID-BASED RADON MITIGATION TECHNOLOGY DEVELOPMENT FOR INDUSTRIAL APPLICATIONS K. V. tiu, J. D. Gabor, R. E. Hoitz, and K. C. Gross Argonne National Laboratory 9700 S. Cass Ave. Argonne, Illinois 60439 ABSTRACT The objective of the radon mitigation technology development effort is to develop an efficient and economical radon gas removal technology based on a fluid absorption process. The technology must be capable of cleaning up a wide range of radon gas stream concentrations to a level that meets EPA gas emission standards for residential and industrial applications. Argonne has recently identified a phenomenon that offers the possibility of radon recovery from the atmosphere with high efficiency at room temperature, and radon release at slightly elevated temperatures (50-6OOC). Such a device would offer numerous substantial advantages over conventional cryogenic charcoal systems for the removal of radon. Controlled sources of radon in Argonne s radon research facility are being used to quantitatively assess the perfonnance of a selected class of absorbing fluids over a range of radon concentrations. This paper will discuss the design of laboratory- and engineering-scale radon absorption units and present some preliminary experiential test results. INTRODUCTION Radon gas (Rn-222) is a major contributor to the natural radiation exposure of the average individual in the U.S. and is considered the most serious health threat of all the known indoor air contaminants. Past EPA studies [ 19933 have indicated that up to 14,000 deaths occurring annually in the U.S. may be attributed to indoor radon exposure. The removal of radon gas from nuclear facilities, uranium mines, and industrial sites has received increased attention. An early goal of this work was to establish process feasibility, and then determine optimal performance parameters such as flooding characteristics, saturation capacities, Henry s Law coefficients, fluid aging stability, packing material physical characteristics, absorption and desorption rates, etc., for a fluid-based system for removal and isolation of radon. The approach was to use controlled sources of radon in Argonne s radon research facility to quantitatively assess the above performance parameters for a selected class of absorbing fluids over a range of radon concentrations. Degassing methods cornsidered were thermal (already proven m Argonne experiments), mechanical agitation, thin film flow, ultrasonic, and microwave. The engineering development effort builds upon the promising laboratory equilibrium radon removal results obtained using an oil-based liquid absorbent. Initial absorber tests focused on confirming the proof-of-concept in a laboratory-scale packed absorption tower (Sin. diameter bed). Later tests will be conducted with 3-in. dia. absorption/ desorption system and an engineering pilot scale unit (12-in. diameter bed) which will provide information for the commercial-scale radon removal systems. This paper describes results obtained from static laboratory experiments, dynamic flow tests with a laboratory-scale apparatus, the design of engineering-scale, and commercial-scale radon removal unirs. LABORATORY STATIC EXPERIMENTS Static experiments were conducted for both absorption and desorption of radon in oil. The main emphasis during the initial study has been on the absorption of radon in oil. The results for degassification of radon in oil are preliminary. Although a variety of oils have been examined, most work has been conducted with Mazolaa corn oil. Concentration Factor Measurement The concentration factor, defined as the radon concentration attained in oil divided by the radon T

concentration of the input air stream, has been used as the first criterion to examine the radon absorption capability. During absorption testing, small volumes of oil (50-100 me) were saturated with 17 1 of air containing a known concentration of radon.?he uptake of radon by the oil was then measured. Radorr-Eree air was bubbled through the oil at a rate of 1 e/min. The air was passed through a dry icechilled charcoal trap to remove the radon. The radon from the charcoal was transferred to a Lucus cell scintillation chamber and counted. Mazola@corn oil and different vegetable and hydrocarbowbased oils were tested. Results from these tests are summarized in Fig. 1. It is clearly shown that 3-in-1 oil has the highest concentrationfactor (9.69) of all oils tested. Concentration factors between 8.1 and 8.69 were obtained in the Mazola corn oils tests. Degassing Test Results Earlier tests have shown that all radon can be removed from oil using a thermal degassification method with air purging. Degassing tests were also conducted on ultrasonic radon removal. The ultrasonic degassing results were assessed in terms of a radon removal factor defined as the radon removed divided by radon initially present. For sonication alone, the best removal factor achieved was 0.45. With air purging, the removal factor increased to 0.6. The highest radon removal factor, 0.77, was obtained when the ultrasonic degassing procedure was conducted in conjunction with air purging and partial vacuum conditions. LABORATORY-SCALE EXPERIMENTS A laboratory-scale absorption tower was constructed to obtain data on mass transfer rates and flow characteristics. The tower, which was constructed of Plexiglas@,has a 3-in. I.D. and either a short 1641-1. high or tall 42-in. high packed-bed test section plus flow meters, a differential pressure gauge, and aidoil pumps. The absorbingliquid (corn oil in the initial tests) was circulated by a peristaltic pump. Raschig rings with 1/4-in. and 3/8-in. diameter were used for tower packing. Measurements of radon removal were made with this apparatus in the Argonne Radon Research Facility. A summary of tests with the 1/4-in. Raschig rings is given in Table 1. It is clearly shown that the oil-based absorption column can remove the majority of radon gas in the air stream, up to 98.7%, with a 42-in. packing column under certain flow conditions. The laboratory-scale radon absorption tower has been modified to include a radon desorber (Fig. 2). The desorber is made of a long 2-in. diameter copper pipe with l/li-in. diameter copper Raschig rings.?he desorber is electrically heated with clamp heaters. A portion of the copper tubing leading to the desorber is also heated electrically. This arrangement will pre heat the oil as it is flowing into the desorber. The radon wiu be absorbed in oil at room temperature in the absorption tower and be stripped in the desorber at a higher temperature as shown in Fig. 2. The oil is returned to the absorption tower after it is cooled down to the room temperature. ENGINEERING-SCALE EXP ER 1MENTS The design and construction of an engineeringscale absorption tower has been completed. This tower is 12-in. in diameter and 80-in.high. Testing of an engineering-scale unit is needed to advance toward the commercial-scale design required for industrial radon mitigation. The engineering-scale absorption tower assembly is shown in Fig. 3. The tower consists of four 19.7411. long glass sections. The packing will be supported on a Norton Model 809 support plate. Six different sizes of spray nozzles with flowing ranges from 0.74 to 76 gpm will also be tested. Four types of Norton metal packing No. 1 and No. 1-W HyPak,and No. 25 and No. 40 UlTP (1- to 1-1/2- in.) will be tested. The pressure drop measurement across the packing bed as a function of the air flow rate withoul. oil present is shown in Fig. 4. The pressure drop increases from 0.2 in. water to 0.9 in. water at an air rate about 100 CFM when oil, -23 gpm,is flowing down in the packed column. This unit will be used for Radon 220 removal in the fan loft at Argonne National Laboratory,Building 200. Radon 220 is in the stack release from cell A-3. Because Radon 220 decays rapidly (t 1/2 = 55.6 s) and will decay within the absorbent oil as it circulates through the system, no provision will be made to desorb (strip) the radon from the absorbent. During the course of testing, the exhaust air and oil flow rates will be vaned and each of the packings will be tested. The theoretical radon removal efficiency from this absorption tower is presented in Fig. 5. The analytical results will be verified with the measurements in ANL-Building 200. SCOPING STUDY OF A COMMERCIAL FACILITY A parametric study based on the principles described above was conducted in order to scope the size and operating conditions to be expected in tfie full-scale design of a radon absorption tower based on the needs of the Department of Energy (DOE) Femald facility. The computer program, ISGA by Sherwood, IPigford, and Wilke [ 19751, was modified

TABLE 1 RADON ABSORPTION IN A LABORATORY-SCALE TOWER Conditions: 3411. I. D. Plexi las@ tower 3.5 ft depth of 174411. RascElig Rin s Inlet radon concentrationin ar: 28.25 pcit Inlet radon concentration in corn oil: 0 pci/.. d Test No. 38 39 40 41 42 43 44 45 46 48 Rn in Air Out, W E 65.55 53.74 40.04 53.14 3 1.43 16.41 3.70 8.81 117.06 116.60 *Based on gas phase controlling. Air Flow, thin 1.0 1.0 1.o 1.o 2.0 2.0 Oil Flow, E min and employed in this study. The off-gas flow was assumed to be 250 CFM at 88 F containing 38,550 pci/e radon in air. A radon decontamination of the gas stream to a level of 1100 pci/e (97% removal) as required for EPA compliance, was assumed in the calculation In these initial scoping calculations, the effect of the following parameters was assessed: 1. Packing size, 2. Transfer unit height, 3. Radon gas solubility, and 4. Flooding and absorption design calculational factors. The tower was considered to be filled with Raschig rings. Packing size varied from 114 in. to 3 in. The height-of-transfer units for both gas phase and liquid phase transfer were varied over an arbitrary range of 0.25 to 1.75 from a reference value. The tower diameters were established by the flooding rates dependent on the packing size. The tower diameters have a range from 3.25 to 8.92 ft. The predicted packing height varied from 3.5 ft for the 0.25 factor to 24.6 ft for the 1.75 factor. CONCLUSIONS Significantprogress has been made, as summarized below: Static test results showed that the radon concentration factor for refined Mazola corn oil was in a range between 8.1 and 8.9. The Transfe:r Unit Number 1.84 2.l3 2.28 1.93 2.38 3.11 5.14 4.07 1.27 1.28 Transfer Unit Height * ft 1.90 1.65 1.54 1.82 1.47 1.13 0.68 0.86 2.76 2.74 Radon Removal, % 77.3 81.4 86.2 81.8 89.1 94.3 98.7 97.0 59.5 59.7 results of degassing tests conducted using heat, agitation, and ultrasonic sonication have shown that heat and agitation can remove essentially all radon from the oil, whereas the highest radon removal factor using sonication with evacuation was found to be 0.77. The labscale test apparatus having a 3-in. diameter and 16- and 42-in. high packed beds has been designed, constructed, and tested successfully. A series of dynamic radon absorption flow tests were conducted using a 1/4-in. size Raschig ring packing material in the 341-1. diameter and 42-in. packed tower. The prelimimary test results showed that the radon absorption rate of 97-98.7% range was achieved for an oil rate of 259 rnt/min and air rate of E/min. The design of a pilot engineering-scale radon removal test unit is complete. A 12-in. diameter, 80-in. high absorption column with 1in. diameter commercial packing rings has been assembled and will be tested for Radon 220 removal. A computer program was modified and employed to conduct a parametric study to scope the size: and operating conditions to be expected in the full commercial-scale design of a radon absorption tower for a DOE Femald facility. The plresent analysis has resulted in an absorption tower with a diameter of 3.3 ft and a

tower packing height of 14 ft for >in. Raschig ring packing. The oil flow rate would be 268 gpm,and the gas flow rate would be 250 CFM. ACKNOWLEDGMENTS This work was supported by the U. S. Department of Energy, under Contract Number W-31-1WEng38. The authors would like to express their appreciation to F. Markum,M. T. Zawadzki, W. A. Bezella, J. Wu, and E. W. O'Hare for their contribution during the course of the study. REFERENCES Home Buyer's and Seller's Guide to Radon, EPA Report 402-R-93-003, March 1993. T. K. Sherwood, R. L. Pigford, and C. E. Wilke, Mass T r a q e r, Me-Graw-Hill, New York, 1975. M. Steinberg and B. Manowitz, Recovery of Fisswn Product Noble Gases, Ind. and Eng. Chem. 5L, pp. 47-50, 1959. Conanearion Fowr (AborpUon Cop.eity I Input Concmaallon) FIG. 2. THDREE-IN. DIAMETER ABSORPTION / DESORF'TION SYSTEM. I -1 3h 1 0 1 2 3 4 5 6 7 8 S 10 FIG. 1. HIGHEST MEASURED CONCENTRATION FACTORS OF RADON IN VARIOUS OILS AT 2OOC. FIG. 3. TWELVE-IN. DIAMETER ENGINEERING ABSORPTION TOWER ASSEMBLY.

0 so 100 150 200 2s 0 FIG.4. PRESSURE DROP ACROSS THE 6-FT PACKED COLUMN WITH FOUR TYPES OF PACKINGMATERIALSANDWITHOUTOIL FLOW E IP I FIG.^. EFFECT OF THE FLOW 'RATES ON THORON REMOVAL IN THE 12-IN. DIA. ABSORPTION TOWER WITH 1-IN.HY-PAK PACKINGS.