Warming the workplace

Similar documents
HEC - High Efficiency Condensing Heaters. Warming the workplace. 12kw to 1000kw Efficiency of up to 109% Nett High/Low or Fully Modulating Heater

CP+ Gas & Oil Cabinet Heater Range

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

Cast Iron Boilers. G Series ( kW)

Exhaust Duct Design Page 1 of (C)

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Technical information. Remeha P200. Pressurized boiler. Heat output: kw

Installation and Operating Manual Drying Cabinet

PREEVA air handling unit

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

VPC Gas Cabinet Heater Range

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

Technical information. Remeha P 500. Pressurized boiler. Heat output: kw

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

Ca 6s and BCa 6s kw INSTALLATION AND OPERATING INSTRUCTIONS. Page 1 31/07/00

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

Design Specifications for Panda 900A Car Spray Booth

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

Pressure Jet Boilers. Pressure Jet Range. Commercial Heating Solutions.

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

BMM Heaters Limited. Compact HM Range. Installation, Service and User Manual

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

pressurejetrange Buccaneer GTE, Falcon GTS, Harrier GTS, Viceroy GTS, Viscount GTS, Vanguard L Pressure jet boilers kW

BENSON HEATING INSTALLATION OPERATION AND SERVICING MANUAL

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

User's Instructions. Alpha CB50

1. GENERAL SAFETY RULES

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Synergy Grill User & Engineer Installation & Conversion Guide

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity

OPERATING AND MAINTENANCE MANUAL

TE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity

AIR CURTAIN GUIDE WHAT IS AN AIR CURTAIN?

LED (CLASSIC) DECK OVEN

R e m e h a P Technical Information. Remeha P 300. Pressurized boiler. Heat output: kw

pressurejetrange Buccaneer GTE, Falcon GTE, Harrier GTE, Viceroy GT, Viscount GTE, Vanguard L Pressure jet boilers kW

BENSON.... Variante3 Fired Unit Heaters...

Biomass. Biomass solid fuel boiler range

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

Sirius WH. Working towards a cleaner future

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Burner Comparisons. Typical Competitor s Burner

INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

This appliance must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations.

OUH Suspended Oil Unit Heater

DOMINATORPLUS ELECTRIC RANGE APPLIANCES INSTALLATION and SERVICING INSTRUCTIONS

Installation, start-up use and maintenance manual

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC Directives for the voltages stated on the data plate.

RAYPAK HOT WATER & HEATING

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

Baxi Maxflow Combi FS

Bx OVEN SET UP AND OPERATION OF OVEN AND CONDENSER UNIT (IF FITTED) CLASSIC

Brivis Inverter Icebox

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

Sirius FS. Working towards a cleaner future

P R O F E S S I O N A L C O O K I N G

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

SKYPAK II Heating & Cooling Self Contained Packages

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

HYBRID SERIES FURNACES. napoleonheatingandcooling.com

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

N 700 BOILING PANS ZANUSSI RANGE COMPOSITION FUNCTIONAL AND CONSTRUCTION FEATURES

Xpelair Simply Silent DX150

Series 4. Rotary rack oven. For pastry chefs and bakers, Series 4 rotary rack ovens concentrate a range of technology to ensure real benefits:

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

AquaNova. Water heater. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Cooker Hood CHIM60 CHIM70 CHIM90 CHIM101 CHIM110. Installation & User s instructions

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A

Firebird Enviromax Condensing Range

OPERATING AND MAINTENANCE MANUAL

INSTRUCTION MANUAL FOR OIL BURNER MODELS

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

SUBMITTAL SCHEDULE & DATA

Condensing Units CUS 15-60

SKG Advantages. Typical Applications. Typical Installation

FEATURES AND BENEFITS

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

Hoval SR-plus heating boilers Outputs from 350 to 4000kW Working pressures to 8 bar

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

Transcription:

Air Heater Manufacturers Warming the workplace

BMM Heaters Limited design and manufacture industrial and commercial warm air heating systems. Our heaters are suitable as standard for Natural Gas, LPG, Oil and also Dual Fuel.These heaters are designed to give high efficiency, reliability and manufactured to give good access for ease of maintenance. Standard heaters are designed to give output from 12kw to 952kw, larger outputs available on request. These Units are available in all firing orientations, discharge can be horizontal, downward or upward, depending on the application. They can be purchased for very high air pressures and very high gas pressures and their range of uses include make up air, air handling, general heating and high temperature process heating. Major Companies we have experience working with: Alcan AMC Cinemas Automobile Association Asda Stores BBC British Gas B.I.C.C Blackpool Airport British Leyland British Steel Butlins British Bakeries British Rail British Aerospace British Telecom British Army British Waterways British Caledonian Airways Black & Decker Boots Chemists Burger King Burnley Football Club Buxted Chicken Company Cambridge Airport Cannon Co-Operative Superstores Crompton Eternacell Curry's Stores Dept. of the Environment Docklands Arena Dixon's Stores Earls Court Electricity Boards English Industrial Estates French Aerospace Gatwick Airport GKN Glasgow University Government Research Stations (poultry) Heathrow Airport Honda H.M Customs & Excise H.M Prisons ICI Jaguar Cars Jersey Gas KP Food Group Littlewoods Stores Lords Cricket Ground Lucas MFI McDonalds Restaurants Metro Centre Marks & Spencer Mercedes Ministry of Agriculture National Exhibition Centre National Poultry Tests Ltd Nissan NSK Peugeot Talbot Rolls Royce Rover Royal Air Force Royal British Legion Russian Federation Sharps Spillers Foods Texas Home Care Stores TGI Friday Restaurants UCI Cinemas United Biscuits Walkers Crisps Walls Sausages West Mercia Police HQ 2

Heat UNITS Indirect MODELS 12/BMG to 952/BMG 12KW to 952 KW BMG Standard Horizontal, Units suitable for Natural Gas GAS / LPG / OIL INTERNAL/EXTERNAL Can be ordered Horizontal discharge or Downward discharge. BMPG Standard Horizontal, Unit suitable for LPG BMO Standard Horizontal, Unit suitable for Oil I n t e r n a l E x t e r n a l What is a Heat Unit A Heat Unit is a source of Heat only to a supply of air provided by others. It should not be confused with a complete Heater incorporating its own fan to supply air. Purpose of Heat Unit A source of Heat to existing ventilation supply. An alternative form of heating for use with air handling equipment where electric, steam or hot water coils are not practical. Indirect Fired The term 'Indirect Fired' indicates that the products of combustion are kept isolated from the main supply airstream. The burner fires a flame into a combustion chamber, the heated products of combustion are directed into a heat exchanger and from there into an external flue which is then discharged into the atmosphere. type Gas burners are available for ON/OFF HIGH/LOW or FULLY MODULATING CONTROL. Oil burners are available for ON/OFF or HIGH/LOW Control. Unit type Units are available in a very wide range of heat outputs, designed for high efficiency and built to the latest Regulations and Directives. All Modules are constructed from a pentapost framework and consist of a Stainless Steel Combustion Chamber, Mild Steel Heat Exchanger with Double Skinned and Insulated front panel to protect the burner and ancillary controls from heat. All other external panels are of single skin construction. External Cabinets All have double skin panels. s and Fuel Units are available with forced induced draught gas burners, suitable for propane or natural gas; pressure jet oil burners or dual fuel burners capable of fully automatic operation. 3

Heat Units Indirect Examples shown for design of flue installation Examples shown for installation design for minimum working distances Width of Unit Width of Unit Plan Wall Ideally minimum clearance required is width of unit as per data sheets for servicing front and rear of module Width of Unit Min. Height 1000mm Ceiling Optional flanged flue system section flanged to provide easy removal for servicing Floor Access doors both upstream and downstream of module to be provided for service personnel. A Top flue configuration utilising 45 o condensation trap to transpose to vertical flue. B Extra support required for stack in excess of 23Kg ( lbs) C 90 o condensation trap to horizontal flue spigot. Consideration for Design When designing a System, allowance must be made so equipment can be serviced after installation and for the fitting of any spares which may be needed. Also consideration for the flue arrangement so that they can be dismantled for servicing to take place (examples only). The Standard Unit The Standard Unit as described above is designed to be installed within an air handling unit or ductwork. Units with all external panels double skinned and insulated are available for self contained internal use with optional single skinned burner extension housing and weatherproofed for external installation. All external units are supplied with combustion air intake grille, hinged access door with lock and support stays and internal inspection lamp. All units are supplied with a fully automatic start burner with sequence controls in accordance with CE approval and to the latest British Standards and Directives etc. When a unit is required to be installed within a larger cabinet, perhaps to accommodate a higher volume air supply, adjustable air balancing plates can be installed to correct the balance of air between the unit and the by-pass area of the cabinet. Units are available for horizontal, upwards or downwards discharge. The Standard finish is in galvanised mild steel but can be supplied in an oven baked epoxy paint finish if required. Process Heat Units Process Heat Units are also available for normal space heating, low temperature air handling, or high temperature process heating. As high temperature process units are very specialised we would suggest contacting our Technical Sales Department before designing your system. Overheat Protection An overheat lockout manual reset thermostat will provide overheat safety protection against supply air fan failure or drastic reduction in air flow, resulting in the burner going to a hold-off condition and will not function again until the manual reset button has been pressed. The combined overheat and fan control thermostat has the ability to allow the burner to give pre warm up to prevent cold air being dispersed when the unit is first started. After a preset temperature has been reached it operates the supply air fan, thus discharging the warm air produced. When the heat is no longer required the burner is switched off but the supply air fan is allowed to continue to dissipate heat from the combustion chamber until the residual heat is removed. If this overheat facility is not required provision must be made to install a fan over-run timer to provide the same function. Overheat protection must be fitted. Pipe All indirect fired heat units must have a flue. It is important to have a well designed flue system which should be a minimum of two metres in height and clear the apex of a roof by at least one metre. Whenever possible, horizontal runs of flue should be avoided. Supports should be provided for the flue and not rely on the unit for support. If the flue is more than fifty pounds in weight it should be self supporting. A condensation trap with a clean-out door should always be fitted at the base of the flue. Down Draught On external units it may be preferred for aesthetic reasons to fit a flue system which is as short as possible, however a minimum of one metre length should be fitted above the cabinet to reduce down draught problems. If a down draught problem is anticipated, possibly due to the location of the flue terminal in relation to adjacent buildings or to prevelant site and landscape turbulence, an anti down draught cowl is recommended or in extreme cases the fitting of an l.d. Fan dilution system. The fitting of a burner fan over-run timer is particularly recommended to prevent heat damage to the burner internals after shut-down. Combustion Chamber / Heat Exchanger The standard combustion chamber/heat exchanger consists of a stainless steel combustion chamber with a mild steel heat exchanger of multi-tube construction with a condensation trap and clean out door at either end. If by location the heat unit is to utilise part or full fresh air and is situated near the coast, in salt air, high humidity or areas of chemical process, corrosion could affect the heat exchanger and internals of the unit when shut down. To avoid this, consideration should be made to install an inlet damper to prevent air being introduced into the module when shut down or fit a stainless heat exchanger at an extra cost. 4

5 4 Heat Units Indirect MODEL KW Output 12 15 18 23 30 12 15 18 23 30 I n t e r n a l U n i t s Standard sizes shown in mm 470 790 Mains input and overheat thermostat, with plug in burner lead. 7 6 Standard E x t e r n a l U n i t s 790 1105 470 6 295 15 3 7 360 1 230 1 Removable front and rear access panels Front Option 345 1 1105 1 1 Combustion Air Intake Grille External Standard units will have burner and flue positioned as shown above. can be positioned on opposite side providing we are notified. can be catered for on the same side as burner at extra cost. The installer should familiarise himself with any Planning Regulations, Building Regulations, Fire Regulations or Insurance Requirements and undertake whatever is necessary to satisfy these regulations. Whichever fuel is used great care should be taken to ensure that the Installation is safe and complies with all the above Regulations. Model 12 15 18 23 30 Heat Output BTU x 1000 40 60 80 100 Heat Output K w 12 15 18 23 30 Gas flow rate M3/hr 1.5 1.8 2.2 2.9 3.9 Electrical Requirements 240V/1ph/Hz 240V/1ph/Hz 240V/1ph/Hz 240V/1ph/Hz 240V/1ph/Hz Running Current 0.3A 0.3A 0.3A 0.3A 0.3A Gas Inlet Size Weight (Internal) Kg 66 66 66 66 66 Weight (External) Kg Min. Air Volume c.f.m. 800 800 800 1000 1600 Min. Air Volume M3/Sec.37.37.37.47. Pressure Drop at Minimum Air Volume accross Standard Chamber at Ambient Temperature (Nominal) 1Pa 1Pa 5

800 700 355 Heat Units Indirect MODEL KW Output 44 59 88 44 59 88 I n t e r n a l U n i t s Standard sizes shown in mm 805 1090 Mains input and overheat thermostat, with plug in burner lead. 990 890 Standard 990 610 1 330 Removable front and rear access panels 44/59/88 E x t e r n a l U n i t s Front Option 400 1090 1390 805 890 295 1 610 1 1390 330 1 Combustion Air Intake Grille External 44/59/88 Standard units will have burner and flue positioned as shown above. can be positioned on opposite side providing we are notified. can be catered for on the same side as burner at extra cost. The installer should familiarise himself with any Planning Regulations, Building Regulations, Fire Regulations or Insurance Requirements and undertake whatever is necessary to satisfy these regulations. Whichever fuel is used great care should be taken to ensure that the Installation is safe and complies with all the above Regulations. Model 44 59 88 Heat Output BTU x 1000 1 200 300 Heat Output K w 44 59 88 Gas flow rate M3/hr 5.4 7.3 10.9 Electrical Requirements Running Current Gas Inlet Size Weight (Internal) Kg Weight (External) Kg 240V/1ph/Hz 1.3A 190 204 240V/1ph/Hz 1.7A 192 207 240V/1ph/Hz 1.7A 3/4 B.S.P. 192 207 Specialised Models Manufactured to customers individual requirements. Sizes, outputs etc. can be catered for on application. Min. Air Volume c.f.m. 17 2400 3300 Min. Air Volume M3/Sec.82 1.13 1.55 Pressure Drop at Minimum Air Volume accross Standard Chamber at Ambient Temperature (Nominal) 1Pa 1Pa 6

800 700 355 Heat Units Indirect Standard sizes shown in mm I n t e r n a l U n i t s MODEL KW Output 117 147 117 147 965 1240 Mains input and overheat thermostat, with plug in burner lead. 1260 1160 Standard 610 24 200 1260 365 Removable front and rear access panels E x t e r n a l U n i t s Front Option 400 610 117 147 965 1240 345 117-1660 147-1870 1160 355 600 200 117-1660 147-1870 365 1 Combustion Air Intake Grille External Standard units will have burner and flue positioned as shown above. can be positioned on opposite side providing we are notified. can be catered for on the same side as burner at extra cost. The installer should familiarise himself with any Planning Regulations, Building Regulations, Fire Regulations or Insurance Requirements and undertake whatever is necessary to satisfy these regulations. Whichever fuel is used great care should be taken to ensure that the Installation is safe and complies with all the above Regulations. Model 117 147 Heat Output BTU x 1000 400 0 Heat Output K w Gas flow rate M3/hr Electrical Requirements Running Current 117 14.5 240V/1ph/Hz 1.7A 147 17.4 240V/1ph/Hz Specialised Models Manufactured to customers individual requirements. Sizes, outputs etc. can be catered for on application. Gas Inlet Size Weight (Internal) Kg Weight (External) Kg Min. Air Volume c.f.m. Min. Air Volume M3/Sec 1 B.S.P. 228 246 40 2.11 1 B.S.P. 232 2 50 2.58 Your Choice We can supply the Heat Units for you to install in your cabinets or alternatively you supply your cabinet to us and we will install. Pressure Drop at Minimum Air Volume accross Standard Chamber at Ambient Temperature (Nominal) 1Pa 7

1110 1010 Heat Units Indirect MODEL KW Output 176 205 235 264 293 176 205 235 264 293 I n t e r n a l U n i t s Standard sizes shown in mm 1120 1410 Mains input and overheat thermostat, with plug in burner lead. 1490 1390 420 510 Removable front and rear access panels 910 2 176 BMG only- 200 1490 600 E x t e r n a l U n i t s 1410 2100 1120 1390 498 356 910 2 176 BMG only- 200 2100 420 1 Combustion Air Intake Grille External Standard units will have burner and flue positioned as shown above. can be positioned on opposite side providing we are notified. can be catered for on the same side as burner at extra cost. The installer should familiarise himself with any Planning Regulations, Building Regulations, Fire Regulations or Insurance Requirements and undertake whatever is necessary to satisfy these regulations. Whichever fuel is used great care should be taken to ensure that the Installation is safe and complies with all the above Regulations. Model 176 205 235 264 293 Heat Output BTU x 1000 600 700 800 900 1000 Heat Output K w 176 205 235 264 293 Gas flow rate M3/hr 21.8 25.4 29.1 32.7 36.3 Electrical Requirements 240V/1ph/Hz 240V/1ph/Hz 240V/1ph/Hz 240V/1ph/Hz 240V/1ph/Hz Running Current Gas Inlet Size 1 1 1 1 1 Weight (Internal) Kg 384 384 384 384 384 Weight (External) Kg 420 420 420 420 420 Min. Air Volume c.f.m. 6800 7900 9000 10,000 11,000 Min. Air Volume M3/Sec 3.19 3. 4.23 4. 5.17 Pressure Drop at Minimum Air Volume accross Standard Chamber at Ambient Temperature (Nominal) 1Pa 1Pa 1Pa 8

1110 (1110-352BMG) 1010 (1010-352BMG) 510 Heat Units Indirect MODEL KW Output 352 440 513 586 352 440 513 586 Standard sizes shown in mm. Model 352 measurements in (brackets). I n t e r n a l U n i t s 2190 (2090-352BMG) 1700 (1700-352BMG) Mains input and overheat thermostat, with plug in burner lead. 2555 (2200-352BMG) 2455 (2100-352BMG) Standard 320 (380-352BMG) Removable front and rear access panels 910 E x t e r n a l U n i t s 352, 440 & 513 BMG - 300 586 BMG - 355 Front Option 2555 (2200-352BMG) 790 (610-352BMG) F RONT S IDE TOP 2190 (2090-352BMG) 3355 (2820-352BMG) 1700 (1700-352BMG) 2455 (2100-352BMG) 610 24 320 (380-352BMG) Combustion Air Intake Grille 1 8 910 External 352, 440 & 513 BMG - 300 586 BMG - 355 3355 (2810-352BMG) Standard Units will have burner and flue positioned as shown above. can be positioned on opposite side providing we are notified. can be catered for on the same side as burner at extra cost. The installer should familiarise himself with any Planning Regulations, Building Regulations, Fire Regulations or Insurance Requirements and undertake whatever is necessary to satisfy these regulations. Whichever fuel is used great care should be taken to ensure that the Installation is safe and complies with all the above Regulations. Model 352 440 513 586 Heat Output BTU x 1000 1200 10 17 2000 Heat Output K w 352 440 513 586 Gas flow rate M3/hr 43 54.5 63.5 72.6 Electrical Requirements 240V/1ph/Hz 240V/1ph/Hz 240V/1ph/Hz 240V/1ph/Hz Running Current 5.3A 5.3A 5.9A 5.9A Gas Inlet Size 1 2 B.S.P. 2 B.S.P. Weight (Internal) Kg 1100 1146 1299 1364 Weight (External) Kg 1400 1432 1623 1704 Min. Air Volume c.f.m. 14,000 18,000 20,000 22,000 Min. Air Volume M3/Sec 6.3 8.46 9.40 10.34 Pressure Drop at Minimum Air Volume accross Standard Chamber at Ambient Temperature (Nominal) 1Pa 1Pa 9

2805 2630 Heat Units Indirect MODEL KW Output 733 880 952 733 880 952 I n t e r n a l U n i t s Standard sizes shown in mm 2022 Mains input and overheat thermostat, with plug in burner lead. 2733 2583 2480 2733 E x t e r n a l U n i t s 2022 3608 406 610 1840 865 Removable front and rear access panels 2 2490 3608 Combustion Air Intake Grille External Standard units will have burner and flue positioned as shown above. can be positioned on opposite side providing we are notified. can be catered for on the same side as burner at extra cost. The installer should familiarise himself with any Planning Regulations, Building Regulations, Fire Regulations or Insurance Requirements and undertake whatever is necessary to satisfy these regulations. Whichever fuel is used great care should be taken to ensure that the Installation is safe and complies with all the above Regulations. Model 733 880 952 Heat Output BTU x 1000 20 3000 32 Heat Output K w 733 880 952 Gas flow rate M3/hr 80.6 108.9 118 Electrical Requirements 415V/3ph/Hz 415V/3ph/Hz 415V/3ph/Hz Running Current Gas Inlet Size 2 B.S.P. 2 B.S.P. 2 B.S.P. Weight (Internal) Kg 2160 2160 2160 Weight (External) Kg 2304 2304 2304 Min. Air Volume c.f.m. 27,0 32,0 35,000 Min. Air Volume M3/Sec 13 15.35 16.53 Pressure Drop at Minimum Air Volume accross Standard Chamber at Ambient Temperature (Nominal) 1Pa 1Pa 17 5Pa 10

Heat Units Indirect Showing example of Internal / External Heat Units being fitted into larger cabinets Showing Units installed in alternatively sized cabinets,where the optional by-pass Damper Facility is required and optional flue configuration available. Unit fitted in oversize cabinet showing optional position of air balancing plates F LUE LA YOUTS A External Unit showing optional short flue set with standard or anti-downdraught cowl A. Short horizontal offset to higher vertical flue rise acceptable Avoid long horizontal runs of flue pipe. As we have explained a Heat Unit is only part of another Manufacturers Unit (Air Supply, Filters, Electric Supply, etc., are all part of your system). BMM test all their appliances before they leave the factory. One should realise that our Equipment is not made in large production batches. Every system is individual and we recommend that you build and assemble all your equipment with the Ancillary (Our Heater) to make your unit complete and undertake a Simulated Test to iron out any problems and ensure that everything is to your satisfaction before delivery to site. Servicing Adequate room must be available for a service engineer to gain access to all sides of the module. Particular consideration should be given by the installer to provide sufficient space for the removal of the combustion chamber and burner for maintenance and servicing. Access doors for personnel both up and down stream of the module should be made available in adjacent cabinet chambers or ductwork. Design If you are unsure about any aspect of the heat module design please do not hesitate to contact our Technical Sales Department. Commissioning On site commissioning of Units is available on request. Commissioning by a BMM Engineer is recommended, not only for correct settings of burner combustion but also to advise on items such as correct air volume, by-pass settings, the linking up of external controls and supply air fan motor control equipment. The use of this service could prevent the possibility of unnecessary post commissioning down time of expensive air handling equipment. Controls Our Technical Sales Department can give advice on linking into other manufacturersʼ control systems. Air Required The minimum amount of air required should be of even distribution when entering the Unit. All pressure calculations/ resistances for air are at ambient with the Heater in the Off position. Specialised Units manufactured to customers individual requirements, sizes, outputs etc. can be catered for on application. Your Choice We can supply the Heat Units for you to install in your cabinets or alternatively you supply your cabinet to us and we will install. Due to our policy of innovation and development we reserve the right to alter the specification without prior notice. 11

1 Copeland Court, Forest Grove, Riverside Park, Middlesbrough, TS2 1RN. Tel: 01642 240700 Fax: 01642 240708 Email: sales@bmmheaters.co.uk www.bmm heaters.co.uk