NEW RANGE OF WARM AIR CURTAINS

Similar documents
XLA-C SERIES BASIC AIR CURTAINS OVERVIEW CHARACTERISTICS

CASSETTE UNIT. Comfort Circle

Energy-efficient heat source provides comfort in large rooms

8/S1 AIR CURTAINS SONATA, SONATA-V. v 1.0 (en)

42AM. Air heaters PRODUCT SELECTION DATA

Comfort Air Curtains with in-built dynamic advertising

COR Series AIR CURTAINS. Air curtains. Dimensions (mm) Accessories. Technical characteristics

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

GAS AIR HEATER RANGE

Recessed. Air Curtain. Fig 1. Recessed air curtain

CLEVER CONTROL Version: V3

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

Instruction Manual WARNINGS

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

KPSW CONSOLE TERMINAL UNIT

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

CAW Ceiling-mounted fan heaters for hot water

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

AIR CURTAINS. Air curtains with integrated control panel and remote control. Air curtains without heating, with electric heating or water heating

FINESSE. Full manual INSTALLATION. VCF-B-xxx-... VCF-C-xxx-... B

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

CLIMATE SEPARATION SOLUTION. SensAir

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Thermozone ADR 200/300 E/W

Thermozone AC 300/WAC 300

Fan Coil Range HYDRONIC TERMINALS

Air curtains. 114 MRX condensing gas air curtain. 118 MRA-H gas air curtain. 121 MRA-A ventilation only air curtain

System architecture. Air treatment Index

CLIMATE SEPARATION SOLUTION. SensAir

DOORS P -SERIES. Shop & Business MADE OFAIR. The smart way for Shop & Business TEDDINGTON AIR CURTAIN SYSTEMS FILTERLESS OPERATION

UniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

Blower-YEFB-020-3R-1maxVel

SIMPLICITY FULL MODULARITY?

NEW INTELLIGENT AIR TECHNOLOGY

energy efficient air curtains technical data and controllers

Bi2 4tubes * SLR 4T Fan coil radiator for heating and cooling at the same time. FEATURES. Cools, Dehumidifies, Heats and Filters

AIR CURTAIN T SURFACE MOUNTED RANGE

Fan Coil Unit CULTRA

GreenCon On/Off Room Thermostat

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

HEAT RECOVERY VENTILATION UNIT DESCRIPTION. FANS s Plug fans. s Direct drive continuous current motors with electronic switching

GreenCon On/Off Room Thermostat

Wall Mounted Split Systems

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

KOMFORT EC DB Suspended heat recovery air handling units

Energy-saving operation

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Fan coil unit KL. Wall unit Ceiling unit

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

The green and friendly entrance. Comfort air curtains Model CA 2

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

SILVERTOP RANGE ENERGY RECOVERY

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

Technical documentation Fan coil unit

MRXBOXAB-ECO3 MRXBOX-ECO3

The CAB & DAB Air Curtains

MRXBOXAB-ECO2 MRXBOX-ECO2

SIMPLICITY OR FULL MODULARITY?

Comfortline L Series The appreciated, flexible Design Air curtain for mounting up to 4 metres

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Air curtains. For a comfortable indoor climate

Centrifugal air heaters hot water or electrical supply

42GWC Hydronic Cassette Fan Coil Units

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Air Curtains. For a better working environment. Tel:

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

WOLF VENTILATION SYSTEM PRICE LIST

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

WOLF WARM AIR CURTAIN

KaDeck. Fan Coils. KaDeck. Versatile air conditioning for offices and commercial buildings. Technical Catalogue

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS

Water-cooled chillers with High Speed Centrifugal Compressors

UniTrane Ductable Units D-line and B-Line

Thermozone AD Corinte

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION

Brochure EX

F series close control air conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings.

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

ATC Heating Devices. P. 1 ATC Heating Devices

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

SkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board

PRODUCT GUIDE

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

Fan heater SWT Ceiling mounted fan heater with water heat

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Transcription:

NEW RANGE OF WARM AIR CURTAINS stay connected and informed in real time www.france-air.com

CONTENTS SELECTION GUIDE 3 HARMONY ONE EVO Compact single-phase warm air curtain 4 REGULATION 5 HARMONY Visible warm air curtain 6 HARMONY FINESSE Warm air curtain that can be flush-mounted onto suspended ceiling 8 HARMONY VERTICAL Tertiary vertical warm air curtain 10 PRICES 12 2 Created by France Air 2017 - All reproduction rights reserved.

SELECTION GUIDE In order to select the correct warm air curtain, four key criteria must be taken into account: choosing between a visible model or a flush-mounted model, height of the installation, width of the door, type of regulation. Discover our Harmony range which meets all your requirements. VISIBLE MODELS (CEILING OR WALL-MOUNTED) APPLICATIONS Small-sized premises (boutiques, counters, cloakrooms, kiosks, petrol stations ) Harmony One Evo Door width (mm) Maximum height of installation (m) Maximum flow rate (m 3 /h) REQUIREMENTS Compact, discreet and simple Minimum sound level (db(a) at 3 m) Type of heating 600 2 310 46,5 Regulation Wireless remote control 900 2 475 48,5 APPLICATIONS Medium- and large-sized premises (shopping centres, superstores and public buildings) Door width (mm) Maximum height of installation (m) Maximum flow rate (m 3 /h) REQUIREMENTS Performance, aesthetics and energy savings Minimum sound level (db(a) at 3 m) Harmony 1 000 4 2 300 43,3 Type of heating Regulation Basic 1 500 4 3 200 44,3 Easy 2 000 4 4 500 41,9 2 500 4 5 700 46,3 Super Harmony Vertical 2 457 7,5 5 400 55,5 FLUSH-MOUNTED MODEL (SUSPENDED CEILING) Harmony Finesse APPLICATIONS Medium- and large-sized premises (boutiques, chain retailers, banks) Door width (mm) Maximum height of installation (m) Maximum flow rate (m 3 /h) REQUIREMENTS Integration, discretion and energy savings Minimum sound level (db(a) at 3 m) 1 000 5 3 020 41,5 Type of heating Regulation Basic 1 500 5 4 160 42,3 Easy 2 000 5 5 270 44,1 2 500 5 6 100 45,3 Super Created by France Air 2017 - All reproduction rights reserved. 3

HARMONY ONE EVO Compact single-phase warm air curtain Harmony One Evo warm air CURTAIN Wireless key remote control CASING IP20 Prices p. 12 ENERGY POWER SUPPLY REGULATION INSTALLATION Single-phase Control 2 m ACCESS THE PRODUCT ONLINE > Heating > Tertiary buildings -heating systems > Warm air curtains ADVANTAGES For heights up to 2 metres. Equipped with tangential fans (2 speeds). New design: intake grille with filter, simplified maintenance. heater with zig-zag technology: reduced heating time. RANGE 2 lengths: 600, and 900 mm. Flow rates: 315 and 475 m 3 /h. : 2.5 and 3.2 kw (1 power stage). DESIGNATION Harmony One Evo 600 length (mm) 900 APPLICATION/USE Elimination of cold air inlets. Primarily adapted for small openings such as those on windows or narrow doors. Also heats small premises such as counters, cloakrooms, drive-thru kiosks, kiosks at petrol stations TECHNICAL DESCRIPTION Dimensions, clearance, and weight Harmony One Evo 600 Harmony One Evo 900 CONSTRUCTION/COMPOSITION Casing: Galvanised steel structure (0.80 mm thick) RAL 9010. Protection rating IP 20. supply: 230 V - 50 Hz. Delivered with 3 m long power supply line. Fan: Tangential type, 60 mm diameter. Remote control: 30 m max. radio frequency/remote control signal. Fan: LS/HS switching. heater: On/off position. Wall mounting bracket. heater: Zig-zag technology for rapid heating: 40 seconds to obtain 100% output. Integrated thermostat with manual reset: Post-ventilation: Once the air curtain is stopped, safety post-ventilation is activated for 30 seconds. This function is indicated by a flashing LED on the remote control. Operating limits Installation indoors. Ambient temperature range: +5 C at +40 C, RH < 80%. Specifications LS/HS flow rate (m 3 /h) Dimensions in mm. Max. range (m) Motor output (W) Heating capacity Total current (A) Sound level (db(a)) Weight (kg) One Evo 600 285-315 2 57 2,4 11 46,5 6 One Evo 900 410-475 2 87 3,1 14 48,5 8 Sound pressure level measured at 5 m at high speed. ASSEMBLY AND CONNECTION SPECIFICATION TEXT Available on www.france-air.com, Espace Pro area. We recommend using a Harmony One Evo model slightly wider than the opening over which it will blow the warm air. 4 Created by France Air 2017 - All reproduction rights reserved.

3 CONTROL LEVELS FOR HARMONY AND HARMONY FINESSE WARM AIR CURTAINS With the brand new control designed for France Air warm air curtains, an optimal level of comfort is guaranteed in the protected area whilst making energy savings. The control analyses the environment and adjusts its settings in real time. TFT LCD touch screen with colour interface for optimal navigation. Calibrated curtains learn independently when doors open. Temperature and speed are adjust automatically according to requirements. Integrated calendar for monitoring and planning. Night/summer/winter modes for greater comfort and savings. Plug & Play installation to control up to 11 curtains in master/slave mode. BASIC EASY SUPER General information Control type Manual Touchscreen Touchscreen On/Off at the front Air flow rate regulation Operating mode Manual Manual/Auto* Manual/Auto Manages when doors open/close (constant speed, speed adaptation) Temperature regulation Temperature setpoint adjustment coil regulation Off/Level 1/Level 2 Off/Level 1/Level 2 coil regulation On/Off On/Off 0-10 V Temperature measurement NTC Room thermostat Summer/winter mode Heating boost Maintenance and safety Filter replacement alarm Other functions Hourly programming Optional (timer) Master/slave control (up to 11 units) (1+10) Error contact CMS communication Modbus RTU PWM (1+10) RTU/TCP Modbus Self-learning mode * Only turns on/off with door contact. Created by France Air 2017 - All reproduction rights reserved. 5

HARMONY Visible warm air curtain MC1 technology Prices p. 12 CAP design ENERGY COMMUNICATION RANGE Modbus RTU 4 m ACCESS THE PRODUCT ONLINE > Heating > Tertiary buildings -heating systems > Warm air curtains ADVANTAGES Compact model: Height of 231 mm. Low sound level. Installation height up to 4 metres. New length available: 2.5 metres. Up to 11 master/slave curtains. RANGE 2 versions: Standard: 3800 m 3 /h - 3.2 m range. Optimised: 5700 m 3 /h - 4 m range. 4 lengths: 1000, 1500, 2000, 2500 mm. 3 energy sources: SC :. EL : electrical heating. EC: hot water heating. 3 control levels: -Basic - : Simple manual control. Easy:Touch-sensitive control means the device is easy to control, faults are displayed or daily programming/cms communication can be managed. Super: Smart touch-sensitive control means that the heating is controlled automatically via the "self-learning"/cms communication function. DESIGNATION Harmony 1000 EL Basic Lengths (mm) ENERGY SOURCES Adjustments Standard 1000 EL: Basic +: Optimised 1500 EC: hot water Easy 2000 SC: no heating Super 2500 Easy (slave version) Super (slave version) APPLICATION/USE The Harmony air curtain positioned above an entrance creates a barrier which considerably reduces exchanges between indoor and outdoor environments. Used in heating mode, it creates a thermal barrier and prevents cold air from entering. Used without heating, it prevents odours, insects and outdoor pollution from entering and limits the entry of warm air in the summer. Harmony is particularly suited to entrances in tertiary premises (shops, shopping centres and offices). SUPER CONTROL The Super control guarantees an optimal level of comfort in the area protected by the air curtain whilst saving energy. The control analyses the environment and adjusts its settings in real time. Changes in air flow rates based on temperatures measured and when doors open. Planned operation thanks to integrated calendar. Energy savings thanks to calibration of maximum temperatures (summer mode). CONSTRUCTION/COMPOSITION Casing: Protection rating IP 20. Galvanised steel structure in RAL 9010 (other colours available on request). "Straw system" supply air grille for laminar air flow. Fan motor assembly: Tangential fan, 230 V/50 Hz power supply. Heating: heater with MCI technology, 3-ph 400 V +N/50 Hz power supply: instant heating, highly responsive warm air curtain = energy savings, shock-resistant, easy to maintain. coil with CAP technology: anti-dust design for longer service life, prevents dust accumulation, reduced maintenance cycles. Control system: See p. 5. Master/slave assembly: The Harmony air curtain allows a maximum of 11 master/slave air curtains to be simultaneously installed, all controlled using one single control panel (Easy or Super control). SPECIFICATION TEXT Available on www.france-air.com, Espace Pro area. TECHNICAL DESCRIPTION Dimensions, clearance, and weight A B C Harmony Harmony + A B C Weight (kg) (mm) (mm) (mm) EL EC SC 1000 360 231 1192 28 28 27 1500 360 231 1600 35 35 33 2000 360 231 2100 42 42 40 2500 360 231 2511 49 50 47 1000 360 231 1192 29 30 28 1500 360 231 1600 39 39 38 2000 360 231 2100 49 50 48 2500 360 231 2511 58 57 55 6 Created by France Air 2017 - All reproduction rights reserved.

TECHNICAL DESCRIPTION Technical characteristics Harmony Harmony + Range max. (m) Air flow rate (m 3 /h) Heating capacity Sound level db(a) at 3 metres* General power supply 1-speed 2-speed 3-speed 1 st level 2 nd level 1-speed 2-speed 3-speed current intensity (A) 1000 EL 3,2 650 1000 1500 3,16 6,32 43,3 48,9 53,8 6,4 14,2 400 1500 EL 3,2 1200 1650 2250 5 10 44,3 50,5 55,1 10,2 21,1 400 2000 EL 3,2 1900 2500 3300 6,32 12,64 41,9 48,6 56,8 12,9 27,7 400 2500 EL 3,2 2200 3000 3800 8,16 16,32 46,3 51,2 58,6 16,7 24,5 400 1000 EC 3,2 650 1000 1500 16.9** 16.9** 43,3 48,9 53,8 0,1 0,6 230 1500 EC 3,2 1200 1650 2250 24.7** 24.7** 44,3 50,5 55,1 0,2 0,9 230 2000 EC 3,2 1900 2500 3300 35.7** 35.7** 41,9 48,6 56,8 0,3 1,4 230 2500 EC 3,2 2200 3000 3800 43.3** 43.3** 46,3 51,2 58,6 0,4 2 230 1000 SC 3,2 650 1000 1500 - - 43,3 48,9 53,8 0,1 0,6 230 1500 SC 3,2 1200 1650 2250 - - 44,3 50,5 55,1 0,2 0,9 230 2000 SC 3,2 1900 2500 3300 - - 41,9 48,6 56,8 0,3 1,4 230 2500 SC 3,2 2200 3000 3800 - - 46,3 51,2 58,6 0,4 2 230 1000 EL 4 1300 1750 2300 4,74 9,48 43,3 48,9 53,8 9,8 14,9 400 1500 EL 4 1600 2400 3200 7,5 15 44,3 50,5 55,1 15,4 23,4 400 2000 EL 4 2500 3500 4500 9,48 18,96 41,9 48,6 56,8 19,6 30,6 400 2500 EL 4 3500 4600 5700 12,24 24,48 46,3 51,2 58,6 25,4 38,8 400 1000 EC 4 1300 1750 2300 22.4** 22.4** 43,3 48,9 53,8 0,2 1,5 230 1500 EC 4 1600 2400 3200 31.8** 31.8** 44,3 50,5 55,1 0,3 1,9 230 2000 EC 4 2500 3500 4500 44.4** 44.4** 41,9 48,6 56,8 0,4 3,3 230 2500 EC 4 3500 4600 5700 53.7** 53.7** 46,3 51,2 58,6 0,5 4,4 230 1000 SC 4 1300 1750 2300 - - 43,3 48,9 53,8 0,2 0,9 230 1500 SC 4 1600 2400 3200 - - 44,3 50,5 55,1 0,3 1,4 230 2000 SC 4 2500 3500 4500 - - 41,9 48,6 56,8 0,4 1,9 230 2500 SC 4 3500 4600 5700 - - 46,3 51,2 58,6 0,5 2,2 230 * Sound pressure level in db(a) at 3 metres in accordance with EN ISO 3743-1 and 3744. ** Water temperature of 90/70 C speed 3. Harmony hot water Harmony Harmony + Air inlet temperature: 18 C. Harmony electrical Harmony Harmony + Air inlet temperature: 18 C. Water temperature 1-speed 2-speed 3-speed Outlet temp. Outlet temp. Outlet temp. Water flow rate (l/s) Voltage (V) Water pressure drop (kpa) 1000 EC 80/60 C 7,68 57,30 10,60 53,00 14,10 48,70 0,62 10,30 1500 EC 80/60 C 13,20 54,50 16,60 51,10 20,58 47,80 0,90 7,26 2000 EC 80/60 C 20,30 53,30 24,60 50,40 29,79 47,40 1,31 10,59 2500 EC 80/60 C 24,10 54,50 30,20 51,20 36,22 48,60 1,59 16,68 1000 EC 60/40 C 12,80 50,20 15,60 47,00 18,59 44,10 0,82 16,97 1500 EC 60/40 C 16,30 51,50 21,50 47,20 26,36 44,10 1,16 11,48 2000 EC 60/40 C 24,60 50,40 31,00 46,80 36,40 44,10 1,62 15,79 2500 EC 60/40 C 33,70 49,50 40,50 46,60 46,40 44,30 1,97 24,72 1000 EC 80/60 C 4,65 40,70 6,32 37,90 8,27 35,20 0,36 4,12 1500 EC 80/60 C 7,81 38,50 9,71 36,50 11,86 24,50 0,52 2,75 2000 EC 80/60 C 12,00 37,90 14,40 36,10 17,26 34,30 0,75 4,02 2500 EC 80/60 C 14,50 38,90 18,00 36,90 21,33 35,30 0,93 6,47 1000 EC 60/40 C 7,53 36,10 9,09 34,20 10,71 32,50 0,47 6,57 1500 EC 60/40 C 9,51 36,70 12,40 34,10 14,97 32,30 0,65 4,22 2000 EC 60/40 C 14,40 36,10 17,90 34,00 21,06 32,40 0,92 5,79 2500 EC 60/40 C 19,90 35,90 23,70 34,10 26,90 32,70 1,14 9,42 1-speed 2-speed 3-speed Stage 1 Stage 2 Stage 1 Stage 2 Stage 1 Stage 2 T supply air T supply air T supply air T supply air T supply air T supply air 1000 EL 3,16 27,48 6,32 47,17 3,16 27,48 6,32 36,96 3,16 24,32 6,32 30,64 1500 EL 5,00 30,50 10,00 43,00 5,00 27,10 10,00 36,20 5,00 24,70 10,00 31,30 2000 EL 6,32 28,00 12,64 38,00 6,32 25,60 12,64 33,20 6,32 23,70 12,64 29,50 2500 EL 8,16 29,10 16,32 40,30 8,16 26,20 16,32 34,30 8,16 24,40 16,32 30,90 1000 EL 4,74 28,90 9,48 39,90 4,74 26,10 9,48 34,30 4,74 24,20 9,48 30,40 1500 EL 7,50 32,10 15,00 46,10 7,50 27,40 15,00 36,80 7,50 25,00 15,00 32,10 2000 EL 9,48 29,40 18,96 40,80 9,48 26,10 18,96 34,30 9,48 24,30 18,96 30,60 2500 EL 12,24 28,50 24,48 39,00 12,24 26,00 24,48 34,00 12,24 24,40 24,48 30,90 Created by France Air 2017 - All reproduction rights reserved. 7

HARMONY FINESSE Warm air curtain that can be flush-mounted onto suspended ceiling MC1 technology Prices p. 14 CAP design ENERGY COMMUNICATION RANGE Modbus RTU 5 m ACCESS THE PRODUCT ONLINE > Heating > Tertiary buildings-heating systems > Warm air curtains ADVANTAGES Compact model: Height of 301 mm. Low sound level. Installation height up to 5 metres. New length available: 2.5 metres. Up to 11 master/slave curtains. RANGE 2 versions: Standard: 5460 m 3 /h - 4 m range. Optimised: 6100 m 3 /h - 5 m range. 4 lengths: 1000, 1500, 2000, 2500 mm. 3 energy sources: SC :. EL : electrical heating. EC: hot water heating. 3 control levels: -Basic - : Simple manual control. Easy:Touch-sensitive control means the device is easy to control, faults are displayed or daily programming/ CMS communication can be managed. Super: Smart touch-sensitive control means that the heating is controlled automatically via the "self-learning"/cms communication function. DESIGNATION Harmony F 1000 EL Basic Lengths (mm) ENERGY SOURCES Adjustments F: Standard 1000 EL: Basic F+: Optimised 1500 EC: hot water Easy 2000 SC: no heating Super 2500 Easy (slave version) Super (slave version) APPLICATION/USE The Harmony Finesse air curtain positioned above an entrance creates a barrier which considerably reduces exchanges between indoor and outdoor environments. Used in heating mode, it creates a thermal barrier and prevents cold air from entering. Used without heating, it prevents odours, insects and outdoor pollution from entering and limits the entry of warm air in the summer. Harmony Finesse is particularly suited to entrances in tertiary premises: shops, offices, public buildings). SUPER CONTROL The Super control guarantees an optimal level of comfort in the area protected by the air curtain whilst saving energy. The control analyses the environment and adjusts its settings in real time. Changes in air flow rates based on temperatures measured and when doors open. Planned operation thanks to integrated calendar. Energy savings thanks to calibration of maximum temperatures (summer mode). CONSTRUCTION/COMPOSITION Casing: Protection rating: IP 20. Structure made of steel. Steel supply/return grille painted in RAL 9010 (other colours available on request). Fan motor assembly: Centrifugal fan, 230 V 50 Hz supply. Heating: heater with MCI technology, 3-ph 400 V +N/50 Hz power supply: instant heating, highly responsive warm air curtain = energy savings, shock-resistant, easy to maintain. coil with CAP technology: anti-dust design for longer service life, prevents dust accumulation, reduced maintenance cycles. Control system: See p. 5. Master/slave assembly: The Harmony Finesse air curtain allows a maximum of 11 master/slave air curtains to be simultaneously installed, all controlled using one single control panel (Easy or Super control). SPECIFICATION TEXT Available on www.france-air.com, Espace Pro area. TECHNICAL DESCRIPTION Dimensions, clearance, and weight A B C 250 596 640 301 27 595 Harmony F Harmony F+ A B C Weight (kg) (mm) (mm) (mm) EL EC SC 1000 1085 1124 1166 42 43 40 1500 1585 1624 1666 57 58 53 2000 2085 2124 2166 73 75 68 2500 2465 2504 2546 80 82 75 1000 1085 1124 1166 46 48 44 1500 1585 1624 1666 62 63 59 2000 2085 2124 2166 84 75 69 2500 2465 2504 2546 85 92 79 8 Created by France Air 2017 - All reproduction rights reserved.

TECHNICAL DESCRIPTION Technical characteristics Harmony F Range max. (m) Air flow rate (m 3 /h) Heating Sound level db(a) at 3 metres* 1-speed 2-speed 3-speed capacity 1-speed 2-speed 3-speed General power supply current intensity (A) 1000 EL 4 1030 1540 2250 9,4 41,5 49,6 57,9 9,9 17,7 400 1500 EL 4 1430 2200 3230 15 42,6 52,1 60,2 15,8 28,5 400 2000 EL 4 1880 2920 4360 19 44,3 53,3 61,2 20,0 35,7 400 2500 EL 4 2380 3600 5300 24,5 45,3 54,5 62,8 25,7 46,5 400 1000 EC 4 960 1450 2140 22.4** 41,2 49,6 57,5 0,5 2,2 230 1500 EC 4 1370 2080 3100 34** 42,3 51,6 59,6 0,8 3,3 230 2000 EC 4 1800 2870 4280 46.3** 44,1 53,3 61 1,0 4,3 230 2500 EC 4 2310 3500 5140 55.2** 45,3 54,4 62,5 1,2 5,4 230 1000 SC 4 1040 1550 2270-42,3 50,3 58,3 0,5 2,2 230 1500 SC 4 1510 2240 3280-42,8 52,1 60,2 0,8 3,4 230 2000 SC 4 2100 3040 4400-44,6 53,7 61,5 1,0 4,2 230 2500 SC 4 2480 3670 5460-45,3 54,4 62,7 1,2 5,4 230 1000 EL 5 1410 2090 2960 9,4 44,6 53,5 61,2 10,3 21,9 400 1500 EL 5 1880 2810 4080 15 46 55,2 62,7 16,2 32,4 400 2000 EL 5 2450 3660 5180 19 47,3 56,3 64 20,6 41,1 400 2500 EL 5 2910 4350 6020 24,5 49,1 58,2 65,8 26,3 50,7 400 1000 EC 5 1360 2020 2800 26.6** 45,3 54 61,2 0,9 3,8 230 1500 EC 5 1880 2810 3900 39.7** 46,4 55,4 62,5 1,2 5,2 230 Harmony F+ 2000 EC 5 2440 3700 5070 51.9** 47,5 56,4 63,7 1,5 6,5 230 2500 EC 5 2800 4230 5860 60.3** 49,6 58,7 65,6 1,8 7,6 230 1000 SC 5 1460 2120 3020-45,2 54,2 61,9 0,9 3,9 230 1500 SC 5 1950 2830 4160-46,2 55,4 63 1,2 5,2 230 2000 SC 5 2500 3780 5270-47,4 56,5 64,2 1,5 6,7 230 2500 SC 5 3000 4440 6100-49,2 58,3 65,7 1,8 7,9 230 * Sound pressure level in db(a) at 3 metres in accordance with EN ISO 3743-1 and 3744. ** Water temperature of 90/70 C speed 3. Harmony Finesse hot water Harmony Harmony + Air inlet temperature: 18 C. Water temperature 1-speed 2-speed 3-speed Outlet temp. Outlet temp. Outlet temp. Water flow rate (l/s) Voltage (V) Water pressure drop (kpa) 1000 EC 80/60 C 10,6 54,5 14,3 50,2 18,6 46,1 0,2 8,8 1500 EC 80/60 C 15,9 56,7 21,6 52,3 28,5 48,0 0,3 20,8 2000 EC 80/60 C 20,8 56,7 29,4 51,8 38,7 47,5 0,5 17,7 2500 EC 80/60 C 26,1 55,7 35,4 51,3 46,0 47,2 0,6 13,4 1000 EC 60/40 C 13,6 50,9 17,9 46,7 22,0 43,3 0,2 10,9 1500 EC 60/40 C 20,1 53,4 26,6 49,0 33,1 45,5 0,4 25,3 2000 EC 60/40 C 26,1 53,5 35,1 49,0 43,2 45,7 0,5 19,8 2500 EC 60/40 C 30,1 53,7 40,4 49,3 50,2 45,8 0,6 13,4 1000 EC 80/60 C 6,2 38,3 8,2 35,7 10,5 33,2 0,1 4,1 1500 EC 80/60 C 9,6 40,3 12,9 37,6 16,7 34,9 0,2 8,8 2000 EC 80/60 C 12,6 40,2 17,4 37,1 22,5 34,5 0,3 8,1 2500 EC 80/60 C 15,6 39,4 20,8 36,7 26,6 34,2 0,3 6,6 1000 EC 60/40 C 7,9 36,1 10,1 33,6 12,3 31,6 0,1 5,4 1500 EC 60/40 C 12,0 38,2 15,7 35,5 19,3 33,4 0,2 10,8 2000 EC 60/40 C 15,6 38,2 20,6 35,4 25,0 33,4 0,3 8,9 2500 EC 60/40 C 17,9 38,2 23,5 35,5 28,8 33,3 0,3 6,6 Harmony Finesse electrical 1-speed 2-speed 3-speed Supply air temp. Supply air temp. Supply air temp. 1000 EL 9,4 45,38 9,4 36,31 9,4 30,53 Harmony F 1500 EL 15 49,47 15 38,45 15 31,93 2000 EL 19 48,32 19 37,52 19 31,07 2500 EL 24,5 48,88 24,5 38,42 24,5 31,87 1000 EL 9,4 38,00 9,4 31,49 9,4 27,53 Harmony F+ 1500 EL 15 41,94 15 34,01 15 29,03 2000 EL 19 41,27 19 33,57 19 29,00 2500 EL 24,5 43,26 24,5 34,90 24,5 30,21 Air inlet temperature: 18 C. Created by France Air 2017 - All reproduction rights reserved. 9

HARMONY VERTICAL Tertiary vertical warm air curtain MC1 technology Prices p. 15 CAP design ENERGY al ACCESS THE PRODUCT ONLINE > Heating > Tertiary buildings -heating systems > Warm air curtains ADVANTAGES For vertical installation. Orientable supply air grille. Silent. Range up to 7.5 m. : al/hot water/no heating. RANGE Height: 2457 mm. 3 energy sources: SC : no heating. E: electrical heating. supply: 24 kw and 36 kw. Air flow rate: 5400 m 3 /h. EC: hot water heating. supply: 41.1 kw. Air flow rate: 5100 m 3 /h. DESIGNATION Harmony V E 24 Energy E: al 24: 24 kw EC: hot water 36: 36 kw SC: no heating 41: 41.1 kw APPLICATION/USE The Harmony Vertical air curtain positioned above an entrance creates a barrier which considerably reduces exchanges between indoor and outdoor environments. Used in heating mode, it creates a thermal barrier and prevents cold air from entering. Used without heating, it prevents odours, insects and outdoor pollution from entering and limits the entry of warm air in the summer. Particularly suited to tertiary premises: shops, offices, public buildings Possibility of controlling up to 6 units in master/slave configuration. CONSTRUCTION/COMPOSITION Casing: Protection rating IP 20. Structure in RAL 9010 painted steel. Fan motor assembly: Centrifugal fan, 230 V 50 Hz supply. Heating: heater with MCI technology (instant heating): highly responsive warm air curtain = energy savings, low inertia, high shock resistance, easy to maintain. coil with CAP design (anti-dust design): increased warm air curtain service life, prevents dust accumulation, optimises air flow, 3/4" connection, 3-way valve + servomotor included. Control system: Control panel with cables included for manual control. 3 blowing speeds. 2 electrical heating levels. -Post-ventilation - function: 30 sec, on electrical version. Possibility of controlling up to 6 units in master/slave configuration. 3-way valve with servomotor actuated by the control panel (EC version). RJ12 connector. OPTIONS Door strip. Programmable timer. Room thermostat. Harmony Vertical stainless steel version. SPECIFICATION TEXT Available on www.france-air.com, Espace Pro area. Representation showing digital simulation of an air jet on a Harmony Vertical air curtain (seen from above). 10 Created by France Air 2017 - All reproduction rights reserved.

TECHNICAL DESCRIPTION Dimensions Installation 1. Porte Entrance d entrée door Anchoring frame 130 Min. 200 mm Min. 50 mm 2457 300 75 45 2. 606 51 521 Min. 50 mm Min. 100 mm Entrance Porte d entrée door Min. 200 mm Dimensions in mm. Harmony Vertical - Technical characteristics Type Max. range (m) Flow rate (m 3 /h) Sound level db (A) at 3 m supply voltage/ current (V/A) Weight (kg) E 24 7,5 5400 55,5 24 400 + N/33.5 103 E 36 7,5 5400 55,5 36 400 + N/50 103 EC 41 7,5 5100 55 41,1 230/6.5 104 SC 7,5 5500 56-230/6.5 95 Harmony Vertical hot water - Technical characteristics Thermal characteristics* 60/40 C 70/50 C 80/60 C 90/70 C Flow rate (m 3 /h) 5100 5100 5100 5100 19 26,4 33,8 41,1 Outlet temp. 29 33,4 37,6 41,9 Water flow rate (l/s) 0,23 0,32 0,41 0,50 * Air inlet temperature: 18 C. CONTROL ACCESSORIES Door strip Used to start up or stop the air curtain based on when doors open and close. Dry contact. Room thermostat Used to start up or stop the air curtain based on a temperature set by the user, between 5 and 30 C. Dry contact. Programmable timer Used to start up or stop the air curtain based on time slots saved by the user. The warm air curtain can be used manually outside of these time slots. Dry contact. Created by France Air 2017 - All reproduction rights reserved. 11

Rue des Barronnières Beynost 01708 Miribel Cedex www.traitdunion-com.fr